1. Introduction
The WinAPEX HY118A and HY118B are compact, pen-type digital multimeters designed for electrical testing and troubleshooting. These devices offer a range of functions including AC/DC voltage measurement, resistance, capacitance, frequency, diode, continuity, Non-Contact Voltage (NCV) detection, live wire detection, and phase sequence detection. The HY118A features a black and white display, while the HY118B boasts a VA color reverse display for enhanced readability. Both models include a flashlight for working in dimly lit areas and an auto-ranging function for ease of use.

2. Safety Information
Please read and understand all safety warnings and operating instructions before using this multimeter. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Always ensure the multimeter is in the correct function mode before making measurements.
- Do not exceed the maximum input values specified for each range.
- Exercise extreme caution when working with voltages above 30V AC RMS, 42V peak, or 60V DC. These voltages pose a shock hazard.
- Inspect the test leads for damage before each use. Do not use if insulation is damaged or bare metal is exposed.
- Do not operate the multimeter if it appears damaged or if it is not operating properly.
- Replace batteries immediately when the low battery indicator appears to ensure accurate readings.
- Do not attempt to repair or modify the multimeter. Refer servicing to qualified personnel.
- Keep hands and fingers behind the probe barriers during testing.
3. Product Overview
3.1 Components
- Pen-type Multimeter Body: Main unit housing the display, buttons, and internal circuitry.
- Test Probe: Integrated or detachable probe for making contact with circuits.
- External Test Lead (for HY118B): Additional lead for certain measurements.
- Battery Compartment: Located at the rear, for AAA batteries.

3.2 Display and Controls
- LCD Display: Shows measurement readings, function indicators, and battery status. HY118A has a black and white display, HY118B has a VA color reverse display.
- SELECT Button: Used to cycle through different measurement functions within a mode (e.g., AC/DC voltage, resistance/capacitance).
- HOLD Button: Freezes the current reading on the display. Press again to release.
- N/P Button: Activates NCV (Non-Contact Voltage) or Phase Sequence detection mode.
- Flashlight: Integrated LED light for illuminating the test area.


4. Setup
4.1 Battery Installation
- Locate the battery compartment cover on the back of the multimeter.
- Use a screwdriver to open the cover.
- Insert two AAA batteries, observing the correct polarity (+/-).
- Replace the battery compartment cover and secure it with the screw.
Note: Batteries are not included with the device.
4.2 Connecting Test Leads (if applicable)
For models with external test leads (e.g., HY118B), insert the red test lead into the 'VΩmA' input jack and the black test lead into the 'COM' input jack. Ensure connections are firm.
5. Operating Instructions
The multimeter features auto-ranging for most functions, simplifying operation. Use the 'SELECT' button to switch between different measurement types within a mode.
5.1 AC/DC Voltage Measurement
- Turn on the multimeter.
- Select the voltage measurement mode (usually indicated by 'V' or 'ACV/DCV'). Use 'SELECT' to toggle between AC and DC if needed.
- Connect the test probes across the circuit or component to be measured.
- Read the voltage value on the display.
5.2 Resistance Measurement
- Turn on the multimeter.
- Select the resistance measurement mode (usually indicated by 'Ω').
- Ensure the circuit is de-energized before measuring resistance.
- Connect the test probes across the component.
- Read the resistance value on the display.
5.3 Continuity Test
- Turn on the multimeter.
- Select the continuity test mode (usually indicated by a buzzer icon).
- Ensure the circuit is de-energized.
- Connect the test probes across the circuit path. A continuous beep indicates continuity (low resistance).
5.4 Diode Test
- Turn on the multimeter.
- Select the diode test mode (usually indicated by a diode symbol).
- Ensure the diode is disconnected from the circuit.
- Connect the red probe to the anode and the black probe to the cathode. The display will show the forward voltage drop. Reverse the probes; the display should show 'OL' (Open Line) for a good diode.
5.5 Capacitance Measurement
- Turn on the multimeter.
- Select the capacitance measurement mode (usually indicated by 'F').
- Ensure the capacitor is fully discharged before measurement to prevent damage to the meter.
- Connect the test probes across the capacitor terminals.
- Read the capacitance value on the display.
5.6 NCV (Non-Contact Voltage) Detection
- Press the 'N/P' button to enter NCV mode.
- Move the tip of the multimeter close to the wire or outlet you suspect has AC voltage.
- If AC voltage is detected, the screen will display '----', the alarm buzzer will sound, and the LED alarm light will turn red.

5.7 Zero Line / Firewire Recognition
- Ensure the multimeter is in the appropriate mode for live wire detection (often integrated with NCV or a dedicated 'Live' mode).
- Carefully bring the pen tip close to the power test point (e.g., inside an outlet).
- Zero Line Detection: If the indicator light is green, the screen displays '-', and the buzzer sounds slower, it indicates a zero line.
- Firewire Detection: If the indicator light is red, the screen displays '+', and the buzzer sounds faster, it indicates a live wire (firewire).

5.8 Phase Sequence Detection
- Switch the multimeter to the 'P' function (phase sequence function).
- Measuring Point A: Place the induction pen on the first root phase wire. The LCD will show 'PA' and 'A' (not blinking). Wait for a beep.
- Measuring Point B: Place the induction pen on the second root phase wire. The LCD will show 'PB' and 'B' (not blinking). Wait for a beep.
- Measuring Point C: Place the induction pen on the third root phase wire. The LCD will show 'PC' and 'C' (not blinking). Wait for a beep.
- After measuring all three points, the phase sequence result will be displayed on the screen.

6. Maintenance
6.1 Cleaning
Wipe the case with a damp cloth and mild detergent. Do not use abrasives or solvents. Keep the display clean and free from dust.
6.2 Battery Replacement
When the low battery indicator appears on the display, replace the batteries promptly to ensure accurate measurements. Refer to Section 4.1 for battery installation instructions.
6.3 Storage
If the multimeter is not used for an extended period, remove the batteries to prevent leakage. Store the device in a cool, dry place, away from direct sunlight and extreme temperatures.
7. Troubleshooting
- No Display/Power On: Check battery installation and ensure batteries are not depleted. Replace if necessary.
- Inaccurate Readings: Ensure the correct function mode is selected. Check test lead connections. Replace batteries if low.
- 'OL' on Display: Indicates an open circuit (resistance/continuity) or out-of-range measurement.
- No NCV Detection: Ensure NCV mode is active. The voltage source might be too weak or too far from the sensor.
- Auto Power Off: The multimeter has an automatic shutdown feature to conserve battery life. Press any button to reactivate.
8. Specifications
| Feature | Specification |
|---|---|
| Model | HY118A / HY118B |
| Brand | WinAPEX |
| Display Type | Digital Display |
| Display Counts | 6000 Counts |
| Operating Mode | Auto Range |
| DIY Supplies | Electrical |
| Certification | CE |
| Origin | Mainland China |
| Dimensions | 182 x 27 x 20 mm |
| Weight | 65g |
| Operating Temperature | 0 - 40 ℃ |
| DC Voltage Range | 0 - 600V |
| DC Voltage Accuracy | ±(0.8% + 3) |
| AC Voltage Range | 0 - 600V |
| AC Voltage Accuracy | ±(1.2% + 5) |
| Resistance Range | 0 - 60 MΩ |
| Resistance Resolution | 0.1Ω (low range) |
| Resistance Accuracy | ±(1.2% + 3) |
| Capacitance Range | 0 - 60 mF |
| Capacitance Accuracy | ±(4.5% + 5) |
| Frequency Range | 0 - 10 MHz |
| Frequency Accuracy | ±(2.0% + 5) |
| Diode Test | Yes |
| Continuity Test | Yes |
| NCV Detection | Yes |
| Live Wire Detection | Yes |
| Phase Sequence Detection | Yes |
| True RMS | Yes |
| Data Hold | Yes |
| Backlight | Yes |
| Flashlight | Yes |
| Auto Power Off | Yes |
| Low Battery Indication | Yes |
| Power Supply | 2 x AAA Batteries (not included) |
9. User Tips
- For best accuracy, ensure the test probes are clean and free of corrosion.
- When measuring resistance or continuity, always ensure the circuit is de-energized to prevent damage to the multimeter and ensure safety.
- The flashlight feature is useful for illuminating dark work areas, improving visibility and safety.
- Take advantage of the auto-ranging feature to quickly get readings without manually selecting ranges.
10. Warranty and Support
For warranty information and technical support, please refer to the seller's policies or contact the manufacturer directly. Keep your purchase receipt as proof of purchase.