Universal ZH25G/ZH35G

Contents

DC 12V 24V Refrigerator Compressor User Manual

Models: ZH15G, ZH25G, ZH35G, ZH45G

1. Introduction

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your DC 12V/24V refrigerator compressor. Designed for versatility, these compressors are ideal for automotive, marine, and portable mini fridge/freezer applications. Please read this manual thoroughly before installation and use.

Front view of ZH25G compressor with R134a label
Figure 1: Front view of the ZH25G compressor, indicating R134a refrigerant and 12/24V DC compatibility.

2. Specifications

The following table details the specifications for various models of the DC 12V/24V compressor series. Please refer to your specific model for accurate data.

Detailed specification table for ZH series compressors
Figure 2: Comprehensive specification table for ZH series compressors (ZH15G to ZH75G).
Table 1: Compressor Specifications
Property Value
Compressor Models ZH15G, ZH25G, ZH35G, ZH45G (and others as per table)
Rated Voltage 12-24V DC
Working Voltage Range 9.6~17V / 21.3~31.5V
Refrigerant R134a
Cooling Method Natural cooling / Air cooling
Throttling Device Capillary
Maximum Exhaust Pressure 1.86 MPa (absolute)
Oil Type Ester Oil
Compressor Noise 40dB(A)
Vibration 0.6m/s2
Origin Mainland China

3. Setup and Installation

Proper installation is crucial for the performance and longevity of your compressor. It is recommended that installation be performed by a qualified technician.

3.1 Safety Precautions

  • Always disconnect power before attempting any installation or maintenance.
  • Ensure adequate ventilation around the compressor to prevent overheating.
  • Handle refrigerant (R134a) with care and in accordance with local regulations.
  • Wear appropriate personal protective equipment (PPE) such as gloves and eye protection.

3.2 Mounting the Compressor

The compressor should be mounted on a stable, level surface, ideally with vibration-dampening mounts. Ensure there is sufficient space for air circulation, especially if using air cooling.

Compressor with attached control box
Figure 3: Compressor showing the attached control box, which houses electrical connections.

3.3 Electrical Connections

Connect the compressor to a stable 12V or 24V DC power source, depending on your model and system requirements. Ensure correct polarity and use appropriate gauge wiring to prevent voltage drop and overheating. The control box typically includes terminals for power input and control signals.

Two compressors side-by-side, highlighting control boxes
Figure 4: View of multiple compressors, emphasizing the integrated control boxes for electrical connections.

3.4 Refrigerant System Connection

This compressor uses R134a refrigerant. Connect the compressor to the refrigeration system (evaporator, condenser, filter drier, capillary tube) following standard refrigeration practices. Ensure all connections are leak-free and the system is properly evacuated before charging with refrigerant.

4. Operating Instructions

Once installed and connected, the compressor operates automatically based on the thermostat settings of your refrigeration unit. Ensure the power supply is stable and within the specified voltage range (9.6~17V for 12V systems, 21.3~31.5V for 24V systems).

4.1 Initial Startup

  1. Verify all electrical and refrigerant connections are secure.
  2. Ensure the system has been properly evacuated and charged with R134a refrigerant.
  3. Apply power to the refrigeration unit.
  4. The compressor should start and begin cooling. Monitor for unusual noises or vibrations.

4.2 Normal Operation

The compressor will cycle on and off to maintain the desired temperature set by the thermostat. It is designed for continuous operation within its specified parameters. The low noise level of 40dB(A) ensures quiet performance.

5. Maintenance

Regular maintenance helps ensure optimal performance and extends the lifespan of your compressor.

5.1 Cleaning

  • Keep the compressor and its surroundings clean and free of dust and debris.
  • For air-cooled systems, regularly clean the condenser coils to ensure efficient heat dissipation.

5.2 Inspections

  • Periodically check electrical connections for tightness and signs of corrosion.
  • Inspect refrigerant lines for leaks or damage.
  • Listen for any unusual noises or vibrations during operation.

5.3 Refrigerant and Oil

The compressor uses Ester Oil. Refrigerant levels should only be checked and adjusted by a qualified technician. Do not attempt to add or remove refrigerant without proper training and equipment.

6. Troubleshooting

This section provides solutions to common issues you might encounter. For complex problems, contact technical support.

Table 2: Common Troubleshooting Steps
Problem Possible Cause Solution
Compressor does not start
  • No power supply
  • Incorrect wiring
  • Voltage outside operating range
  • Faulty thermostat or control unit
  • Check power connection and fuse.
  • Verify wiring against diagram.
  • Ensure stable 12V/24V DC supply.
  • Test thermostat/control unit.
Compressor runs continuously
  • Low refrigerant charge
  • Poor ventilation/overheating
  • Thermostat set too low or faulty
  • Excessive heat load
  • Check for leaks and recharge by technician.
  • Ensure adequate airflow around compressor.
  • Adjust thermostat or replace if faulty.
  • Reduce items in fridge/freezer, ensure door seals properly.
Insufficient cooling
  • Low refrigerant charge
  • Blocked condenser/evaporator
  • Faulty fan (if air-cooled)
  • System leak
  • Check for leaks and recharge by technician.
  • Clean coils.
  • Check fan operation.
  • Inspect all connections for leaks.
Unusual noise or vibration
  • Loose mounting
  • Internal compressor issue
  • Refrigerant line vibration
  • Tighten mounting bolts, add vibration dampeners.
  • Contact support for diagnosis.
  • Secure refrigerant lines to prevent contact with other components.

7. User Tips

  • Ventilation is Key: Always ensure your compressor has ample airflow, especially in enclosed spaces like car trunks or marine compartments. Good ventilation prevents overheating and improves efficiency.
  • Stable Power: Use a stable power source within the specified voltage range. Fluctuations can impact performance and lifespan. Consider a voltage stabilizer if your power source is inconsistent.
  • Proper Refrigerant Charge: While professional help is recommended, ensure your system is charged with the correct amount of R134a. Over or undercharging can lead to poor cooling and compressor strain.
  • Check for Leaks: Periodically inspect all refrigerant connections for any signs of leaks. Early detection can prevent significant performance loss.

8. Product Overview Video

Watch this video for a visual overview of the compressor and its features.

Video 1: Product overview of the DC 12V/24V Refrigerator Compressor.

9. Support

For technical assistance or inquiries, please contact us:

  • Email: hnyztt1009@126.com
  • WhatsApp: +86 19974807773

© 2024 Universal Compressor. All rights reserved.