SUPNOVA Battery Capacity Voltage Monitor

Contents

SUPNOVA Battery Capacity Voltage Monitor

User Manual

Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of your SUPNOVA Battery Capacity Voltage Monitor. This device is designed to accurately measure and display battery voltage and capacity for a wide range of applications, including electric motorcycles, cars, golf carts, marine vehicles, RVs, and boats.

The monitor supports various battery types, including Ternary Lithium, Lead-Acid, and Lithium Iron Phosphate batteries, with a voltage range of 8-100V. It features a clear LCD display, power-off memory, and input reverse connection protection.

Front view of the SUPNOVA Battery Capacity Voltage Monitor displaying 18.0V and 100% battery.

Figure 1: SUPNOVA Battery Capacity Voltage Monitor

Specifications

Detailed view of the monitor with labels for Voltage, Battery Percentage, Set key, Mode key, LCD Color Screen, Power Icon, and a table of specifications.

Figure 2: Monitor Features and Specifications Overview

FeatureSpecification
Voltage Measurement RangeDC8-100V
Working Current≤15mA
Display ModeLCD display (Color screen)
Measurement Accuracy±1% (1 word)
Measurement SpeedAbout twice per second
Operating Temperature-10°C to +70°C
Working Humidity10-80%
Working Pressure80-106kPa
Installation Size5.8 x 2.8 cm (2.3 x 1.1 in)
Overall Size6.1 x 3.33 x 1.35 cm (2.4 x 1.31 x 0.53 in)
Hole Size5.85 x 2.85 cm (2.31 x 1.11 in)
Refresh Rate500ms/time
Supported Battery TypesTernary Lithium, Lead-Acid, Lithium Iron Phosphate
Protection FeaturesProtective shell, Dustproof surface, Input reverse connection protection
Additional FeaturesVoltage display, Power display, Low pressure alarm, High voltage alarm, Automatic calibration, Power off memory
Electricity Detector image highlighting supported battery types and features.

Figure 3: Supported Battery Types and Key Features

Image showing the dimensions of the monitor: 6.1cm (2.4in) length, 3.33cm (1.31in) height, 1.35cm (0.53in) depth.

Figure 4: Product Dimensions

Setup and Installation

Follow these steps to properly install your Battery Capacity Voltage Monitor:

  1. Physical Installation:

    The monitor is designed for panel mounting. Ensure you have a cutout of approximately 5.85 x 2.85 cm (2.31 x 1.11 in) for a secure fit. The overall size of the unit is 6.1 x 3.33 x 1.35 cm (2.4 x 1.31 x 0.53 in).

  2. Wiring Connection:

    Connect the monitor to your battery using the provided connection wire. Observe the polarity carefully:

    • Red Wire: Connect to the positive terminal (B+) of your battery.
    • Black Wire: Connect to the negative terminal (B-) of your battery.

    The product features input reverse connection protection, but correct wiring is always recommended.

    Wiring diagram showing the monitor connected to a battery with red (B+) and black (B-) wires.

    Figure 5: Wiring Diagram

    Rear view of the monitor showing the wiring connector and ventilation slots.

    Figure 6: Rear View with Wiring Connector

  3. Initial Power-On:

    Once wired, the monitor will power on and display the current voltage and battery percentage. It will retain settings even after power is removed (power-off memory function).

Operating Instructions

The monitor features two buttons: a 'SET' key (upper right) and a 'Mode' key (lower right, often depicted as a power icon). These are used for navigating and adjusting settings.

Detailed view of the monitor with labels for Set key and Mode key.

Figure 7: Set and Mode Keys

Entering/Exiting Settings

  • To enter the mode setting page from the main display, press and hold the SET key (upper right button) for 2 seconds.
  • To exit the setting page and return to the main display, press and hold the SET key (upper right button) for 2 seconds again.
  • Alternatively, you can short press the SET key (upper right button) to cycle through different setting modes.

Mode Descriptions and Settings

While in the setting page, use the Mode key (lower right button) for short presses to select options or change values, and the SET key (upper right button) for short presses to confirm and save, or long presses to return to the main page.

  1. Mode 1 - Lead Acid Battery (P) Setting:

    On the lead-acid battery settings page (e.g., "1-P 12"), the voltage value flashes. Short press the Mode key (lower right button) to select the desired battery voltage (e.g., 12V, 24V, 36V, etc.). After selecting, short press the SET key (upper right button) to confirm and save the value. The voltage value will remain displayed. Press and hold the SET key for 2 seconds to return to the main page, or short press the SET key to set other modes.

    Lead-acid battery setting screen (1-P 12) with instructions for selecting the battery voltage.

    Figure 8: Lead-Acid Battery Setting

  2. Mode 2 - Ternary Lithium Battery (L) Setting:

    On the ternary lithium battery settings page (e.g., "2-L 03"), the battery string number value flashes. Short press the Mode key (lower right button) to select the number of battery strings to use. After selecting, short press the SET key (upper right button) to confirm and save the value. The battery string value will remain displayed. Press and hold the SET key for 2 seconds to return to the main page, or short press the SET key to set other modes.

    Note: A fully charged ternary lithium battery string has a saturation voltage of DC4.2V.

    Ternary lithium battery setting screen (2-L 03) with instructions for selecting the number of battery strings.

    Figure 9: Ternary Lithium Battery Setting

  3. Mode 3 - Lithium Iron Phosphate Battery (F) Setting:

    Similar to Ternary Lithium, on the Fe Lithium settings page (e.g., "3-F 03"), the battery string number value flashes. Short press the Mode key (lower right button) to select the number of battery strings. After selecting, short press the SET key (upper right button) to confirm and save. Press and hold the SET key for 2 seconds to return to the main page, or short press the SET key to set other modes.

    Note: A fully charged ferrous lithium battery string has a saturation voltage of DC3.6V.

  4. Mode 4 - Custom High and Low Voltage Settings:

    On this page (e.g., "00.0 000"), the left number represents the low voltage parameter, and the right number represents the saturation voltage parameter. Short press the Mode key (lower right button) to set the bit value. After the bit value is set, long press the Mode key (lower right button) for 2 seconds to shift to the next digit. Once both low voltage and saturation voltage are set, short press the SET key (upper right button) to confirm and save. Press and hold the SET key for 2 seconds to return to the main page, or short press the SET key to set other modes.

    Tip: "000" on the right is actually 00.0. For example, 255 is displayed as 25.5.

    Customize high and low voltage settings screen (00.0 000) with instructions for setting low and saturation voltages.

    Figure 10: Custom Voltage Settings

  5. Mode 5 - Backlight Setting:

    On the backlight settings page (e.g., "5-b 00"), short press the Mode key (lower right button) to toggle between ON and OFF. "ON" means the backlight automatically turns off after 10 seconds. "OFF" means the backlight is always on. Short press the SET key (upper right button) to confirm and save. Press and hold the SET key for 2 seconds to return to the main page, or short press the SET key to set other modes.

    Display backlight settings screen (5-b 00) with instructions for setting backlight behavior.

    Figure 11: Backlight Setting

  6. Mode 6 - Low Voltage Alarm Setting:

    On the low voltage alarm setting page (e.g., "00.0 Lo"), the left number is the alarm voltage parameter. Short press the Mode key (lower right button) to set the bit value. After the bit value is set, long press the Mode key (lower right button) for 2 seconds to shift to the next digit. Once the alarm voltage is set, short press the SET key (upper right button) to confirm and save. Press and hold the SET key for 2 seconds to return to the main page, or short press the SET key to set other modes.

    Note: If you do not customize the low voltage alarm parameters, the product will automatically trigger an alarm when the battery level drops below 10%.

    Low voltage alarm setting screen (00.0 Lo) with instructions on how to set the alarm voltage.

    Figure 12: Low Voltage Alarm Setting

  7. Mode 7 - Alarm Sound Setting:

    On the alarm sound settings page (e.g., "7-A 00"), short press the Mode key (lower right button) to select ON or OFF. "ON" turns on the audible alarm feature. "OFF" turns off the audible alarm feature. Short press the SET key (upper right button) to confirm and save. Press and hold the SET key for 2 seconds to return to the main page, or short press the SET key to set other modes.

    Alarm sound setting screen (7-A 00) with instructions for turning alarm sound ON/OFF.

    Figure 13: Alarm Sound Setting

Maintenance

The SUPNOVA Battery Capacity Voltage Monitor is designed for low maintenance. Keep the display clean and free from dust. Avoid exposing the device to extreme temperatures or direct moisture beyond its specified operating conditions.

No user-serviceable parts are inside. Do not attempt to open or repair the device yourself, as this will void any potential warranty.

Troubleshooting

  • No Display/Power:

    Check the wiring connections. Ensure the red wire is connected to the positive terminal and the black wire to the negative terminal of the battery. Verify that the battery itself has sufficient voltage within the 8-100V operating range.

  • Inaccurate Readings:

    Ensure the correct battery type (Lead-Acid, Ternary Lithium, or Lithium Iron Phosphate) and corresponding voltage/string settings are configured in the monitor's settings (Modes 1, 2, or 3). Incorrect settings will lead to inaccurate capacity and voltage displays.

  • Alarm Sounding Unexpectedly:

    Check the Low Voltage Alarm Setting (Mode 6) to see if the current battery voltage has dropped below the set threshold. If the alarm sound is undesired, it can be turned OFF in the Alarm Sound Setting (Mode 7).

  • Backlight Issues:

    If the backlight turns off too quickly or stays on constantly, adjust the Backlight Setting (Mode 5) to your preference.

User Tips

  • Always ensure the monitor is set to the correct battery type and voltage/string count for accurate readings.
  • The power-off memory function means your settings will be saved even if the device loses power, so you typically only need to configure it once.
  • Consider using the low voltage alarm feature to prevent deep discharge of your battery, which can extend its lifespan.

Warranty and Support

For warranty information or technical support, please contact the seller or manufacturer directly. Keep your purchase receipt as proof of purchase.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.