1. General Information
The Myoslim EMS Body Sculpt series utilizes advanced HI-EMT (High-Intensity Focused Electromagnetic) technology, employing high-energy focused electromagnetic waves to induce powerful muscle contractions. This promotes muscle growth and reshapes the internal structure of muscles. Additionally, it triggers significant fat breakdown by releasing fatty acids from triglycerides, which are then metabolized by the body over several weeks.
1.1 Indications for Use
- Improvement of abdominal tone, strengthening of the abdominal muscles, development of a fitter abdomen.
- Strengthening, toning, and firming of buttocks, thighs, and calves.
- Improvement of muscle tone and firmness, for strengthening muscles in arms.
1.2 Operating Environment
The operating environment of the EMS Body Sculpt instrument series is crucial to ensuring the effectiveness and safety of the device.
- Clean and Hygienic Environment: The environment should be clean and hygienic to prevent external contamination or bacterial infections. Regular cleaning and disinfection of the equipment and its accessories are essential.
- Appropriate Temperature and Humidity: Ensure the operating environment's temperature and humidity are within the appropriate range specified by the device manufacturer. Extreme temperatures or excessive dryness/humidity may impact the device's performance.
- Adequate Lighting: Provide sufficient lighting to ensure operators can clearly see and operate the equipment correctly. This is especially important for conducting precise beauty procedures.
- Good Ventilation: The area where the equipment is operated should have adequate ventilation to ensure air circulation and prevent the accumulation of any harmful gases.
- Safety Measures: The operating environment should have appropriate safety measures, including fire extinguishers and first aid equipment, to address emergencies. Operators should be familiar with the equipment's safety procedures and know how to handle emergency situations.
- Avoidance of Interference Sources: The operating environment for beauty equipment should be kept away from any electromagnetic fields or other devices that could potentially cause interference, ensuring the normal operation of the equipment.
- Operator Training: All operators using beauty equipment should undergo proper training to understand the correct usage and safety procedures of the equipment.
1.3 Patient Profile
This machine is suitable for patients who are seeking healthy weight loss, who have no physical diseases, and who do not have metal substances in their bodies. Please note that this machine is only suitable for adults.
1.4 Description of the Device
The EMS Body Sculpt enables a simple and effective treatment process. You can easily perform by adjusting the digital energy selection treatment plan or diagnostic procedure. Any treatment parameter can be manually adjusted by simply touching the screen. You can also create precise and effective treatment plans by configuring the age group and gender of the person being treated within the machine.
2. Important Safety Instructions
DANGER
Risk of electric shock. Do not open the device casing. No user-serviceable parts inside. Refer servicing to qualified personnel only.
CAUTION
- This device is for adult use only. Do not use on minors or individuals without a health clearance certificate.
- Do not use if you have metal implants, heart disease, cancer, diabetes, or are pregnant/lactating/menstruating.
- Remove all metal jewelry before operation. Avoid contact with open wounds.
- Do not use on a full stomach. Allow at least 1 hour after meals and refrain from eating/drinking during and 1 hour post-treatment.
- Never replace the treatment handle while the device is powered on. Always turn off the power and calibrate the handle before replacement.
- Keep away from strong electromagnetic sources. Do not daisy-chain multiple devices on a single power outlet.
- This product is intended to be used in dry areas only.
1.5 Contraindications
- Wounds on the skin (or avoiding wounds when using).
- Patients with heart disease (such as those with arrhythmias), especially those with pacemakers.
- Cancer patients.
- Patients with infectious diseases.
- Pregnant women, lactating women, menstrual period.
- Major surgery patients, diabetic patients.
- Having any metal in the body.
- People with cerebrovascular disease (stroke patients).
1.6 Possible Side Effects
These effects may include but are not limited to:
- Muscle soreness.
- Reduction in muscle fat.
- Temporary muscle spasms.
- Transient joint or muscle tendon pain.
- Localized redness or skin flushing.
CE Certification
The CE symbol stands for "European Conformity", which declares conformity with all relevant EU health, safety, and environmental protection regulations.
3. Setup
3.1 Handle Exchange
The handle must be calibrated every time it is installed or replaced.
Important: When replacing the handle, you must turn off the power of the machine. The handle cannot be replaced when the machine is powered on.
3.2 Device Start Up/Shut Down
- Connect one end of the power cord to the machine and plug the other end into the socket. Plug the power cord directly into the main socket. Do not connect multiple machines to the socket.
- Move the manual switch on the rear panel to the "O" position.
- Press the button on the front panel.
- When the treatment is finished, press and hold the power button to turn off the machine.
4. Operation
4.1 Navigation Controls
4.1.1 Setting the Therapy by Controls
Pre-treatment regimen can be modified via on-screen controls. The treatment interface displays the following items and functions:
- Navigation controls
- Channels selector
- Stop therapy
- Start/pause therapy
- Setting up therapy parameters
The touch-controlled display allows for clear visibility and adjustment of treatment parameters, including time, energy levels, and patterns. The interface supports multiple languages.
4.2 Unit Settings
The device offers various settings accessible through the touchscreen interface:
- Mode 1: The operation interface for Mode 1 (frequency 5-60Hz) requires you to take out the handle from the handle frame before operation and use the belt to fix the handle to the operating part required by the customer.
- Mode 2: The operation interface for Mode 2 (frequency 30-100Hz) also requires you to take out the handle from the handle frame and use the belt to fix it to the operating part.
- Time Adjustment: Adjust the duration of the treatment.
- RF Settings: Adjust the Radio Frequency (RF) levels for both A and B handles.
- Frequency: 3 different periods of frequency with free adjustment.
- Start/Pause Work Button: To start, pause, or stop the treatment.
Note: Adjust the corresponding intensity according to different customer needs to start the operation. If the customer requests to pause, you can click start/pause. The work button suspends the work, and you can directly click the back button to return after the work is completed.
4.3 Placing the Handle
Please operate according to the controller model you purchased and follow the manufacturer's official documentation to ensure the best experience. If you have any questions, please contact customer service for support.
5. Maintenance
5.1 Daily Inspection
Managers must regularly inspect instruments and components. Check whether the power socket has a reliable connection to the ground. Check whether the power cord of the instrument is damaged before use, and stop using the instrument if it is damaged.
5.2 Cleaning
5.2.1 Cleaning of the Surface of the Device
Instrument cleaning is performed on a regular basis to ensure sanitation and proper functioning. The device housing can be wiped with a damp cloth, soapy water, or a neutral detergent while the instrument is powered off. The logo is silk-screen printed, and other parts are spray-painted. Do not use alcohol-based detergents.
5.2.2 Cleaning of Accessories that Come into Contact with Patient
The parts that come into contact with the skin should be cleaned and disinfected with 75% alcohol before and after use. Do not soak directly in alcohol-based detergent as a whole; wipe with pure cotton material.
5.3 Replacing the Fuse
When replacing the fuse, in order to prevent electric shock, please turn off the power and unplug the power plug. The fuse is set below the handle junction on the back of the machine. An additional spare fuse is included.
5.4 Storage and Transportation
- Storage: The instrument should be stored in the original packaging box, placed in a well-ventilated room. The packaging box should be padded. The ambient temperature should be -10°C ~ 40°C, and the relative humidity should not be greater than 93%. It is not allowed to be placed around flammable, explosive substances, and corrosive gases.
- Transportation: The instrument under the packaging condition is suitable for road, railway, air, and water transportation. During loading, unloading, and transportation, it should prevent severe vibration and shock, and should not be affected by moisture. It should not be mixed with flammable and corrosive substances, and the specific requirements are specified in the order contract.
6. Troubleshooting
| Fault Phenomenon | Causes | Exclusions and Workarounds |
|---|---|---|
| Device not working |
|
|
| Handle not working | Check the handle for loose connection | Reseat the handle |
7. Specifications
| Attribute | Value |
|---|---|
| Brand Name | MYOSLIM |
| Item Type | Massage & Relaxation |
| Power Supply | Alternating Current (AC220V/50Hz AC110V/60Hz) |
| Voltage | 50-1000V AC |
| Application | BODY (Body, Legs/Arms, Hands, Abdomen, Hips) |
| Material | ABS |
| Origin | Mainland China |
| Certification | CE, RoHS |
| Technology | High Intensity Pulsed Electromagnetic Body Sculpting |
| Technology Advantage | No-invasive non-exercise healthy slimming |
| Functions | body contouring, body slimming, body sculpt, muscle build, fat removal, skin tight, butt lift, muscle build, muscle stimulation |
| Handle Options | 4/5 handles Optional |
| High Quality Assurance | CE, ROHS certificates |
| Package Length | 58 cm |
| Package Width | 63 cm |
| Package Height | 54 cm |
| Package Weight | 55.0 kg |
7.1 Electromagnetic Compatibility (EMC) Test Setup
The device has undergone Radiated Electromagnetic Field Immunity Testing according to IEC 61000-4-3:2020 standards.
Test Parameters:
- Port: Enclosure
- Test Level: 30V/m with 80% AM, 1kHz Modulation
- Temperature: 25°C
- Humidity: 54%
EC-Certification of Conformity for the EMS Slimming Instrument.
Alibaba.com Assessed Supplier Quality Assurance Certificate.
8. Warranty & Support
8.1 Warranty Card
- The machine can be replaced with a new one within 7 days from the date of purchase (with the receipt) with the intact appearance.
- The main machine is guaranteed for one year (note: man-made damage is excluded).
- The warranty period for accessories is 3 months (note: man-made damage is excluded).
- The continued use of the instrument beyond the service period shall be subject to the approval of the engineer, and the engineer shall conduct a performance test of the instrument periodically in the subsequent use.
- Scrap instruments and accessories beyond their useful life should be disposed of according to local regulations.
8.2 Warranty Exclusions
Free warranty service is not provided for the following user's failures caused by personal reasons:
- Faults caused by unauthorized disassembly and modification of this product.
- Faults caused by accidental fall.
- Failure caused by lack of reasonable maintenance.
- Failure to operate according to the correct instructions in the instruction manual.
8.3 After-sales Service
- Video technical support
- Online support
- 24 hours online service
- Instructions and operation video training
After the warranty period has expired, please contact the manufacturer directly to provide paid after-sales service. To repair the machine, you must contact the company's business department or dealer, and do not repair it without authorization. Any unpacking without consent will not be guaranteed by our company.
8.4 Manufacturer
Guangzhou Xinwei Electronic Technology Co., Ltd.
9. User Tips
- For best results, consistency is key. Clients often notice a firmer and tighter look on areas like the abdomen and thighs after several sessions.
- Understand that fat loss and muscle toning are progressive and natural processes; immediate drastic changes are not typical.
- Always ensure the handles are securely attached and calibrated before starting a session to prevent interruptions and ensure effective treatment.
10. Additional Resources
For a detailed user manual in PDF format, please refer to the official document: Myoslim EMS Body Sculpt User Manual (PDF).
Product overview video demonstrating the Myoslim EMS Body Sculpt device and its user interface.