1. Introduction
The JIKONG Smart BMS (Battery Management System) is an intelligent protection board designed for large-capacity series lithium battery packs. It features voltage acquisition, high-current active balancing, overcharge, over-discharge, overcurrent, and over-temperature protection, a coulomb meter, Bluetooth communication, and optional GPS remote functions. This BMS is compatible with Lithium Iron Phosphate (LiFePO4), Ternary Lithium, and Lithium Titanate (LTO) battery types.
The protection board utilizes energy transfer active balancing technology, capable of achieving a continuous 1A/2A balance current. This technology ensures battery consistency, extends battery range, and delays battery aging. A mobile application (APP) is available for Android and iOS, allowing users to monitor battery status, modify parameters, and control charge/discharge switches via Bluetooth.
The JIKONG Smart BMS is compact, easy to operate, and versatile, making it suitable for various applications including small sightseeing vehicles, mobility scooters, shared cars, high-power energy storage systems, base station backup power supplies, and solar power stations.
Figure 1: JIKONG Smart BMS with included accessories.
Video 1: JIKONG Smart BMS Unboxing and Overview.
2. Setup
2.1. Packing List
The standard package includes the following items:
- BMS x 1
- Sampling line x 1 (70cm)
- NTC (Temperature Sensor) x 1 (40cm)
- Switch x 1 (50cm)
Figure 2: Packing List for the JIKONG Smart BMS.
2.2. Installation Method
The JK-BxA8S-20PS series protection board is suitable for 3-8 series lithium battery packs. Wiring methods vary depending on the number of cells in the battery pack. Always ensure all connections are correct and secure before powering on the BMS to prevent malfunction or damage.
Before starting the protection board, verify that the balance cable is properly connected and that the P- and B- terminals are correctly wired. Ensure the protection board is securely fixed to the battery core. Incorrect connections can lead to abnormal operation or even burning.
Figure 3: JK-BxA8S-20PS Wiring Diagram.
2.3. APP Installation
To download the mobile APP for your JIKONG Smart BMS, scan the QR code below. An Android device running Android 7 or higher is required.
Figure 4: Mobile APP Link QR Code.
2.4. Interface Definition
The BMS features various interfaces for connectivity and functionality:
- P1 (XH-10AW-2.54): Balance and Acquisition Interface (B-, B1-B8, B+).
- P2 (A1254WF-2A): Buzzer Interface (Optional).
- P3 (A1254WF-4A): Communication Interface (Optional RS485/CAN).
- P4 (1.25T-4PWT): UART Interface.
- P5 (HY2.0-4P): Temperature Interface (for 4 external NTCs, optional).
- P6 (HY2.0-4P): Temperature Interface (for 2 internal NTCs).
- P7 (A1254WF-6A): Display Interface.
- P8 (A1254WF-3A): Parallel Interface.
- P9 (A1254WF-5A): ACC Interface.
- Heating Wire (16AWG): For optional heating function.
- D1: Bluetooth connection indicator.
- P-: Connects to external load or negative terminal of charger (M6 screws).
- B-: Connects to the negative battery terminal (M6 screws).
Figure 5: JK-BxA8S-20PS Connector Diagram.
3. Operating Instructions
3.1. Device Activation
The BMS does not have a physical power-on switch. It is designed for charging activation. After completing the battery assembly, connect a charger (with a voltage 2V higher than the battery voltage) to activate the protection board. Alternatively, if an optional display screen and button are used, the BMS can be activated by pressing the button after connecting the display cable.
3.2. Active Equalization
The active equalization function transfers energy from higher-voltage cells to lower-voltage cells to maintain battery consistency. Before using this function, set the battery type on the APP's parameter setting page. Then, in the common settings, configure parameters such as the number of cells, battery capacity, and the trigger equalization differential pressure (default value can be retained). Voltage and current calibration can also be performed.
The balance current is typically 1A/2A and can be adjusted via the APP based on your battery capacity. The equalization automatically starts when the voltage difference between any two battery strings exceeds the set trigger value and stops when it falls below the set value. If not needed, the equalization switch can be turned off in the APP's BMS control page.
3.3. Heating Function (Optional)
The optional heating function uses a resistance heater or heating film to warm the battery at low temperatures, preventing reduced battery activity and ensuring proper charging/discharging. The designed heating current is 20A. This function can be controlled via the APP. For extreme cold conditions, it is recommended to install a normally closed temperature switch (45°C to 65°C) in series with the heating circuit as a secondary protection to prevent thermal runaway.
3.4. Battery Parallel Function
The BMS supports battery pack parallel functionality, which is useful for energy storage applications. This feature requires the use of parallel modules and disabling the “disable charging current limiting” function within the APP.
3.5. ACC Detection Function (Optional)
The optional ACC detection function enables discharge. There are two methods: applying a voltage between 20V-100V across ACC+ and ACC-, or directly short-circuiting ACC+ and ACC-. Additionally, the C_detect+ and C_detect- interfaces are reserved for charger detection, connecting to the 12V voltage signal output of the charger to enable charging.
3.6. Communication Function (Optional)
The BMS supports optional CAN and RS485 communication. Users can select either CAN or RS485 for multiplexed ports on the APP's BMS control page. When using communication, you can set the address and communication protocol according to your specific requirements and scenarios. Refer to the Jikong Protection Board communication protocol document for detailed information.
4. Maintenance and Protection Features
4.1. Overcharge Protection and Recovery
The BMS includes standard charge overvoltage protection. Users can set the single overcharge protection voltage and recovery voltage via the APP. If any cell's voltage exceeds the protection threshold during charging, the BMS will stop charging. Charging resumes once all cell voltages drop below the recovery voltage, preventing overcharging and cell damage.
4.2. Discharge Undervoltage Protection and Recovery
Standard discharge undervoltage protection is provided. Users can set the battery undervoltage protection voltage, recovery voltage, and automatic shutdown voltage via the APP. If any cell's voltage falls below the undervoltage protection threshold during discharge, the BMS will stop discharging. Discharge resumes when all cell voltages rise above the recovery voltage. If any cell's voltage drops below the automatic shutdown voltage, the BMS will automatically shut down to protect the battery.
4.3. Charge Overcurrent Protection and Recovery
The BMS features standard charge overcurrent protection. Users can set the continuous charging current, overcurrent delay, and overcurrent release time via the APP. If the charging current exceeds the set limit for the specified delay, the BMS will stop charging. Charging resumes after the overcurrent release time.
4.4. Discharge Overcurrent Protection and Recovery
Standard discharge overcurrent protection is included. Users can set the continuous discharge current, overcurrent delay, and overcurrent release time via the APP. If the discharge current exceeds the set limit for the specified delay, the BMS will stop discharging. Discharge resumes after the overcurrent release time. Note: The maximum continuous discharge current should not exceed 200A.
4.5. Overtemperature Protection and Recovery
The BMS provides standard charge and discharge overtemperature protection. Users can set the overtemperature protection and recovery thresholds for both charging and discharging via the APP. If the temperature exceeds the set protection value, the BMS will stop the respective operation (charging or discharging). Operation resumes when the temperature falls below the recovery value.
4.6. Low Temperature Protection and Recovery
Standard charging low temperature protection is included. Users can set the low temperature protection and recovery thresholds for charging via the APP. If the temperature falls below the set protection value, the BMS will stop charging. Charging resumes when the temperature rises above the recovery value. For extremely cold environments, using the optional heating function is recommended for better cell protection.
4.7. Intelligent Sleep
The BMS is equipped with an intelligent sleep function, which can be enabled or disabled via the APP. This function puts the BMS into a low-power state when it detects a standby condition (charging/discharging current less than 1A for 26 consecutive hours), reducing energy consumption. The BMS can be reactivated by pressing a button (if available) or by connecting a charger.
5. Troubleshooting
5.1. Alarm Function (Optional)
The optional alarm function provides external alerts when the BMS detects safety risks such as overtemperature, overcharge, or overdischarge. Consult the APP for specific alarm details and diagnostic information.
5.2. Short Circuit Protection and Recovery
The BMS has built-in short circuit protection. While the trigger current is not user-adjustable, the short circuit protection delay (in microseconds) and recovery time (in seconds) can be set via the APP.
- Charging Short Circuit: If a charging short circuit is triggered upon initial charger connection, it might be due to a high peak current from the charger. Increasing the short circuit protection delay in the APP can help. The protection will clear after the set recovery time.
- Discharge Short Circuit: If a discharge short circuit occurs upon initial load connection, especially with loads having large internal capacitance, an instantaneous high current might trigger the protection. Ensure external wiring has no actual short circuits, then try increasing the short circuit protection delay in the APP. The protection will clear after the set recovery time.
5.3. Emergency Switch
The emergency switch function, accessible via the APP, provides a temporary override in critical situations like over-temperature, over-discharge, over-charge, or a dropped cell string. Activating it will enable charge and discharge for 30 minutes, providing an emergency usage window. Even if a single cell reaches the automatic shutdown voltage during this period, the BMS will continue to operate until the 30-minute cycle ends, helping to prevent dangerous situations like being stranded.
6. Specifications
6.1. Basic Parameters
| Parameter | Value | Unit |
|---|---|---|
| Supply voltage | 7.5-36 | V |
| Series withstand voltage | 100 | V |
| Operating power consumption | <1300 | mW |
| Operating temperature | -30-70 | °C |
| Maximum number of collection strings | 8 | String |
| Maximum balancing current | 1 or 2 | A |
| Maximum charging current | 200 | A |
| Maximum discharge current | 200 | A |
| Maximum instantaneous current | 400 | A |
| Maximum internal loop resistance | 0.35 | mΩ |
| Protective plate size | 152.25*127.26*15.6 | mm |
| Finished weight | 424 | g |
| Supported maximum series battery pack | 12V (6 pack), 24V (3 pack) |
6.2. Default Parameters
The default parameters vary based on battery type (Li-Ion, LiFePO4, LTO). Users can adjust these settings via the APP.
| Parameter | Li-Ion Default | LiFePO4 Default | LTO Default | Unit |
|---|---|---|---|---|
| Balancing initial voltage | 3 | 3 | 2 | V |
| Maximum balancing current | 1 or 2 | 1 or 2 | 1 or 2 | A |
| Unit overcharge voltage | 4.2 | 3.6 | 2.7 | V |
| Unit overcharge protection recovery | 4.18 | 3.55 | 2.65 | V |
| Monomer undervoltage protection | 2.82 | 2.6 | 1.8 | V |
| Single undervoltage protection recovery | 2.85 | 2.65 | 1.85 | V |
| Automatic shutdown voltage | 2.8 | 2.5 | 1.7 | V |
| SOC-0% voltage | 2.9 | 2.6 | 1.85 | V |
| SOC-100% voltage | 4.18 | 3.5 | 2.65 | V |
| Trigger balancing differential pressure | 0.01 | 0.01 | 0.01 | V |
| Charging overcurrent protection delay | 30 | 30 | 30 | S |
| Charging overcurrent protection release time | 60 | 60 | 60 | S |
| Discharge overcurrent protection delay | 300 | 300 | 300 | S |
| Discharge overcurrent protection release time | 60 | 60 | 60 | S |
| Short-circuit protection delay | 5 | 5 | 5 | µS |
| Charging overtemperature protection | 70 | 70 | 70 | °C |
| Charging overtemperature recovery | 60 | 60 | 60 | °C |
| Discharge overtemperature protection | 70 | 70 | 70 | °C |
| Discharge overtemperature recovery | 60 | 60 | 60 | °C |
| Charging low temperature protection | -20 | -20 | -20 | °C |
| Charging low temperature recovery | -10 | -10 | -10 | °C |
| MOS Overtemperature protection | 100 | 100 | 100 | °C |
| MOS Overtemperature protection recovery | 80 | 80 | 80 | °C |
| Device address | 0 | 0 | 0 | / |
7. User Tips
- The JIKONG BMS is highly regarded for its automatic balancing function, especially with 20S battery configurations.
- The accompanying mobile application is intuitive and offers convenient settings for monitoring and control.
- Be aware of the physical dimensions of the BMS, as its size might be a limiting factor for installation in smaller enclosures, such as those found in some electric scooters.
- The charge and discharge current values are adjustable via the APP, but only within the maximum current rating of the specific BMS model (e.g., a 40A BMS can be adjusted to 35A, but not above 40A).
- Many users find JIKONG BMS products to be trustworthy and reliable, often preferring them over other brands for their performance and value.
8. Warranty and Support
For detailed parameter settings and advanced configurations, please refer to the comprehensive PDF user manual provided by JIKONG. For any technical support or warranty inquiries, please contact JIKONG customer service or visit their official website.
The PDF manual can be accessed here: JIKONG Smart BMS User Manual (PDF)