Aninerel ANL-MPPT-48V-60A/80A/100A

Contents

Aninerel MPPT Solar Charge Controller User Manual

Models: ANL-MPPT-48V-60A, ANL-MPPT-48V-80A, ANL-MPPT-48V-100A

This manual provides detailed instructions for the safe and efficient operation of your Aninerel MPPT Solar Charge Controller.

1. Product Overview

Thank you for choosing the Aninerel GD series MPPT controller. This new generation MPPT controller is developed with the latest technology, representing advanced photovoltaic technology. It offers excellent performance, including efficient heat dissipation and intelligent control.

The controller features innovative Maximum Power Point Tracking (MPPT) technology, significantly improving the energy utilization efficiency of solar energy systems with a conversion efficiency of up to 97%. It can quickly scan the entire I-V curve and track the maximum power point within seconds. It supports three types of lead-acid batteries (sealed, colloidal, open type) and lithium battery series charging programs. The controller also includes automatic protection functions for overcharging, over-discharging, overload, and short circuit. An RS485 communication interface allows for multi-machine communication up to 1km, facilitating convenient monitoring of operating parameters via a computer.

2. Product Characteristics

  • MPPT Technology: Utilizes Maximum Power Point Tracking to extract maximum power from the solar array for battery charging, automatically adjusting to environmental changes without user intervention.
  • Automatic Battery Voltage Detection: Supports 12V, 24V, 36V, and 48V systems.
  • 3-Stage Charging: Optimizes battery performance, saves electricity, and extends battery life.
  • Comprehensive Protection: Includes overcharge protection, over-temperature protection, and short circuit protection.
  • Battery Compatibility: Suitable for various battery types such as sealed lead-acid, vented gel, and lithium batteries.
  • Easy Mounting: Designed for straightforward installation.
Product Characteristics
Key product characteristics of the Aninerel MPPT Solar Charge Controller.
Feature Icons
Visual representation of the controller's features including MPPT technology, overcharge protection, current ratings, overtemperature protection, and heat dissipation.

3. Safety Instructions

Please read and understand all safety precautions before installation and operation to prevent personal injury or damage to the equipment.

3.1 General Precautions

  • The input voltage range of this controller is large; operate with caution to avoid personal injury.
  • All work on the charging controller must be carried out by technical personnel.
  • This device is not intended for operation by children or individuals lacking physical, sensory, or psychological abilities, or experience and knowledge.
  • Keep away from children and ensure they do not come into contact with high-temperature shell components.
  • Do not disassemble or attempt to repair the solar charging controller yourself, as this may result in further damage, accidents, and void the warranty.
  • Keep away from flammable and explosive materials to avoid fires.
  • The installation location should be away from damp or corrosive substances.
  • To avoid short circuits, technicians must use insulated tools when operating the equipment.

3.2 Electrical Safety

  • High Voltage Warning: Photovoltaic modules can generate high voltage. Be careful to prevent electric shock during wiring.
  • Ensure the input DC voltage does not exceed the specified maximum voltage. Exceeding this limit may cause permanent damage and void the warranty.
  • To disconnect the solar panel array, use a circuit breaker and prevent accidental re-activation. Disconnect the circuit breaker and ensure it cannot be reconnected.
  • Ensure no voltage is present in the system before working on it.
  • Overvoltage can damage the system. Thunderstorms and lightning can increase the risk of damage; consider external overvoltage protection systems.
Safety Icons
Important safety warnings: professional installation required, keep away from water, operate within specified temperature, ensure good heat dissipation, use pure copper wires, applicable for currents less than 5A, do not set parameters randomly, short circuit protection, overcharge protection, overtemperature protection, MPPT technology, optimize battery performance.

4. Installation

Installation must be completed by professional technicians.

4.1 Selection of Installation Location

  • Install on a solid surface.
  • The installation location must be accessible at all times.
  • Install in a position that allows for removal if needed.
  • The ambient temperature should be between -20°C and 50°C to ensure optimal working environment.
  • Do not install the charging controller in direct sunlight to avoid power loss due to overheating.
  • The controller chassis will become hot during operation. Do not install on flammable building materials or near highly flammable materials.
  • Do not install in areas with potential explosion hazards.

4.2 Safety Distances

Observe the following safety clearances to ensure adequate heat dissipation space around the controller:

DescriptionSafe Distance
Side20 CM
Top30 CM
Bottom30 CM
Installation Safety Distances Diagram
Diagram illustrating the recommended safety distances for installation to ensure proper heat dissipation.

5. MPPT Controller Connection (Wiring)

5.1 System Composition

Solar Charging System Diagram
Diagram showing the typical composition of a solar charging system, including solar panel, MPPT controller, battery, and DC load.

5.2 Wiring Steps

  1. Ensure all DC connection wires have their positive and negative poles correctly connected.
  2. Measure the open circuit voltage of the photovoltaic module to ensure it is within the controller's working range.
  3. Connect the battery first: Turn on the circuit breaker connecting the controller to the battery.
  4. Connect the solar panel: Open the circuit breaker connecting the controller to the solar panel.
  5. The controller will then enter self-test mode. If system conditions are correct, it will automatically enter working mode. If incorrect, a fault prompt will be displayed.
  6. The battery type controller defaults to maintenance-free lead-acid batteries at the factory. Refer to battery type settings for adjustments.

Warning: Short circuits between the positive and negative terminals of the battery and connected wires can pose a risk of fire or explosion. Handle with extreme caution. Connecting the battery pack must be done with the circuit breaker disconnected.

5.3 Cable and Circuit Breaker Specifications

The following table outlines the recommended copper cable sizes and miniature circuit breaker ratings for different controller models:

ModelGD-50AGD-60AGD-80AGD-100AGD-120A
Cable (copper)10mm²16mm²16mm²25mm²25mm²
Circuit breaker63A80A100A125A125A

5.4 Temperature Sensor and PC Connection

An RS485 communication cable is an optional component. If needed, install the upper computer software (purchased separately). The accessories come with detailed usage and installation instructions.

Temperature Sensor and PC Connection Diagram
Diagram showing the connection points for the temperature sensor and PC via USB/RS485.

6. Operation Instructions

6.1 Panel Component Description

Controller Panel Components
Overview of the controller's front panel components.
NumberNameNumberName
1LCD display screen5Junction box cover plate
2Charging indicator light6Flip up button
3Function menu button7Confirm button
4Flip down button8DC output indicator light

6.2 Indicator Light Status Description

NameStateStatus Description
Charge indicatorFlash mobCharging in maximum power tracking mode
Slow flashingFloating charging mode charging
ExtinguishStop charging
BrightNormal output
DC output indicator lightDodgeBattery undervoltage prompt
ExtinguishTurn off output

6.3 LCD Display Screen Description

The LCD display provides real-time information about the controller's status and parameters. Navigation is done using the MENU/ESC, UP, DOWN, and ENTER buttons.

6.3.1 Main Interface Description

LCD Main Interface
Example of the main interface displaying charging status, voltage, and current.

6.3.2 Viewing the Main Interface

In the default main interface, use the DOWN or UP keys to scroll through different screens, displaying various parameters like current curve and power curve.

6.3.3 Main Menu Navigation

Press the MENU key from the default main interface to enter the main menu. Use the DOWN or UP keys to navigate through submenus. Press ENTER to select an option.

6.3.4 Operating Parameter Settings

Attention: Setting operating parameters must be done by professional technicians. Incorrect operation may cause malfunction or damage to the battery.

From the main menu, select 'Run parameter settings' and press ENTER. Enter the password, then proceed to adjust settings such as:

  • Battery Type Settings: Select from lead-acid (maintenance-free, gel, liquid) or lithium battery series. The factory default is maintenance-free lead-acid.
  • Rated Battery Voltage Setting: Set the rated voltage level (e.g., 12V, 24V, 36V, 48V). Automatic recognition is available for lead-acid batteries.
  • Charging Current Setting: Adjust the charging current, ensuring it does not exceed the maximum value.
  • Discharge Limit Setting: Set the cut-off voltage and resumption voltage for DC output.
  • Factory Reset: Restore all operating parameters to factory defaults if the controller is not functioning normally due to incorrect settings.
  • Password: To enter running parameter settings, press DOWN key 3 times, then UP key 3 times, and then ENTER.
Parameter Setting Menu
LCD display showing the parameter setting menu, allowing adjustment of various operational values.

6.3.5 Time and Date Settings

From the main menu, select 'Time and date settings'. Use UP/DOWN to adjust values and ENTER to confirm.

6.3.6 Contrast and Brightness Settings

These settings are adjusted similarly from the main menu, allowing you to optimize the LCD display's visibility.

6.3.7 Record Query and Clearing

Access 'Record query' from the main menu to view curve records or fault records. 'Clear Records' allows you to erase stored data.

6.3.8 DC Output Settings

Configure DC output to 'off', 'automatic', 'time control', or 'light control'. For time control, set specific on/off periods.

6.3.9 Communication Settings

Adjust baud rate and local address settings for RS485 communication.

6.3.10 Language Settings

Select the desired language for the display from the main menu.

7. Technical Parameters

The following tables provide detailed technical specifications for the Aninerel MPPT Solar Charge Controller.

7.1 General Specifications

ModelGD-50AGD-60AGD-80AGD-100AGD-120A
Charge ModeMPPT automatic maximum power point tracking
Charging MethodThree stages: constant current (MPPT), balanced charging, and float charging
System TypeAutomatic recognition/manual setting (12V-24V/12V-48V)
System Identification Voltage Range12V system: DC9V-DC15V
24V system: DC18V-DC30V
48V system: DC36V-DC60V
Soft Start Time≤10s
Dynamic Response Recovery Time<500µs
Static Power Consumption≤2W
Efficiency≥ 96.5%
Utilization Rate of Photovoltaic Modules<99.97%

7.2 Input Characteristics

ParameterValue
MPPT Operating Voltage Range12V system: DC18V-DC 100V
24V system: DC34V-DC 100V
48V system: DC65V-DC150V
Input Low Voltage Protection Point12V system: DC16V
24V system: DC30V
48V system: DC60V
Input Low Voltage Recovery Point12V system: DC18V
24V system: DC34V
48V system: DC65V
Extreme Input VoltageDC170V (40A:95V)
Input Overvoltage Protection PointDC175V (40A:100V)
Input Overvoltage Recovery PointDC170V (40A:95V)

7.3 Maximum Solar Panel Input Power

SystemGD-50AGD-60AGD-80AGD-100AGD-120A
12V system600W720W960W1200W1440W
24V system1200W1440W1920W2400W2880W
48V system2400W2880W3840W4800W5760W
96V system4800W5760W7680W9600W11520W

7.4 Output Characteristics

ParameterValue
Optional Battery Types (Default: maintenance-free lead-acid battery)Lead acid maintenance-free batteries, colloidal batteries, liquid batteries, lithium batteries (customizable)
Floating Voltage (lead-acid battery)12V system: 13.8V
24V system: 27.60V
48V system: 55.20V
Uniform Charging Voltage (lead-acid battery)12V system: 14.5V
24V system: 29V
48V system: 58V
Rated Current50A: 50A
60A: 60A
80A: 80A
100A: 100A
120A: 120A
Current Limiting Protection50A: 52A
60A: 62A
80A: 82A
100A: 102A
120A: 122A
Temperature Coefficient±0.02%/°C
Automatic Temperature Compensation14.2V - (maximum temperature - 25°C) * 0.3
Output Voltage Stabilization Accuracy≤ ±1.5%

7.5 Display and Communication

ParameterValue
LCD DisplayRefer to LCD display instructions for details
LED DisplayCharging indicator, DC output switch status indicator
PC Upper Computer (Communication Port)RS485 (optional)

7.6 Protection Features

ProtectionDescription
Input Low Voltage ProtectionRefer to input characteristics
Input High Voltage ProtectionRefer to input characteristics
Input Polarity Reversal ProtectionCapable of polarity reversal protection
Output Polarity Reverse ProtectionCapable of polarity reversal protection
Short Circuit ProtectionAfter 5 trial starts, it enters the protection state and recovers from the start
Temperature ProtectionAutomatic shutdown/reduction of power
Temperature Rise ProtectionAutomatic shutdown/reduction of power

7.7 Environmental and Physical Characteristics

ParameterValue
Mechanical Protection TypeIP21
Humidity0~90% RH (no condensation)
Altitude0~3000m
Ambient Temperature-20°C ~ +40°C
Storage Temperature-40°C ~ +70°C
Atmospheric Pressure70~106kPa
Audio Noise<50dB
Heat Dissipation MethodForced air cooling; fan speed adjusted by temperature. Fan runs slowly or stops when internal temperature is low. Fan stops when controller is off.
Element QualityImported materials complying with EU standards; electrolytic capacitors rated for temperature not less than 105°C.
OdorNo odor or harmful to health
Environmental RequirementsMeets 2002/95/EC; No cadmium, hydrides, and fluorides.

7.8 Photovoltaic Module Configuration

System Voltage (Battery Voltage)Photovoltaic Module Load Voltage (Recommended Value)
12V system18V-60V (30V component * 1 string, 36V component * 1 string)
24V system36V-72V (2 strings of 30V components, 2 strings of 36V components)
48V system72V~144V (5 strings of 30V components, 4 strings of 36V components)
60V system72V~144V (5 strings of 30V components, 4 strings of 36V components)
72V system144V~180V (5 strings of 30V components, 4 strings of 36V components)
96V system144V~180V (6 strings of 30V components, 5 strings of 36V components)

8. Troubleshooting

If the controller encounters an abnormality, refer to the table below for potential solutions before contacting customer service.

Abnormal Phenomenon of MalfunctionRelieve the Malfunction
MPPT controller powers on for the first time, and the fault prompt is: battery voltage exceeds the normal recognition range.1. Check if the battery voltage is within the system voltage recognition range (refer to technical parameters).
2. Manually set the rated battery voltage level (refer to operating parameter settings).
Fault prompt: Over temperature protection1. Check if the cooling fan is damaged and if ventilation holes are blocked by debris. Ensure the MPPT controller is installed in a well-ventilated environment.
2. Ensure reasonable configuration of photovoltaic modules to improve conversion efficiency and reduce temperature rise.
Fault prompt: Battery overdischarge protectionThe battery has run out of energy.
Fault prompt: No external temperature sensor detectedEnsure the temperature sensor is correctly connected.
The charging indicator light is not on and there is no charging current or charging power display.1. Is the voltage of the photovoltaic module within the MPPT operating voltage range?
2. Check if the charging voltage parameters displayed in the system information are correct.
3. Correct the charging voltage parameters or restore factory settings and restart the MPPT controller.
4. Check if the fuse is blown and if the circuit breaker is disconnected.
The charging indicator light lights up briefly and then goes out quickly, and the charging current is sometimes intermittent.This situation usually occurs on cloudy days or in the evening when there is insufficient sunlight, which is a normal phenomenon.
No power curve and current curve display.Check if the time and date displayed on the MPPT controller are correct (refer to time and date settings).

If the problem persists after following the above table, please contact customer service personnel. Provide equipment information (model, order number, serial number from the back panel) and a detailed description of the problem (system type, frequency, indicator lights, display status, etc.).

9. Maintenance and Cleaning

9.1 Replacing Fuses

If a fuse burns out due to high temperature or other malfunctions, it must be replaced correctly. Remove the broken fuse from the interface, install a new fuse, ensure it is connected correctly, and then reinstall the device. The fuse is located near the wiring junction.

9.2 Cleaning Ventilation Vents and Heat Sinks

Regularly clean the fan vents and internal heat sinks by wiping them with a dry or slightly damp cloth. Do not use detergent or corrosive solvents for cleaning. Prevent liquid from flowing into the machine and ensure that the ventilation holes are not blocked.

10. Quality Assurance

Products that malfunction during the quality assurance period will be repaired or replaced free of charge by our company.

10.1 Evidence for Warranty Claims

During the warranty period, customers must provide invoices and dates of purchase. The product's trademark must be clearly visible; otherwise, the right to quality assurance may be denied.

10.2 Conditions for Replacement

  • The replacement of non-conforming products will be handled by our company.
  • Customers should allow reasonable maintenance time for our company to repair malfunctioning equipment.

10.3 Warranty Exclusions

Our company reserves the right not to provide quality assurance in the following situations:

  • The entire machine and components have exceeded the free warranty period.
  • Damage caused during transport.
  • Incorrect installation or modification for use.
  • Operating in extremely harsh environments beyond those described in this manual.
  • Machine malfunctions or damages caused by non-company service agencies, repairs, modifications, or dismantling.
  • Damage caused by abnormal natural environment.

If a product malfunction is caused by any of the above situations, and the customer requests repair services, we can provide paid maintenance services after assessment by our service agency.

11. User Tips

  • The controller features a very accurate display, which is useful for monitoring system performance.
  • Be aware that the inrush current can be high (e.g., 10A) when connecting the battery. Always connect the battery to the controller first, ensuring the circuit breaker is disconnected, to manage this safely.

12. Additional Resources

For a detailed PDF version of this manual, please refer to the official document: Aninerel MPPT Solar Charge Controller User Manual (PDF).

© 2023 Aninerel. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.