FUZRR FR15B+, FR17B+, FR890C MAX, FR890D MAX

Contents

FUZRR Digital Multimeter User Manual

Models: FR15B+, FR17B+, FR890C MAX, FR890D MAX

1. Introduction

This new digital multimeter features a two-color protective casing, anti-slip ergonomic design, and a large LCD screen. It offers multi-functionality, high precision, high performance, drop resistance, safety, and stability. It can accurately measure AC/DC voltage, high voltage alarm, AC/DC current, frequency, continuity, diode, resistance, capacitance, battery load, NCV, and live wire detection. It also includes error operation circuit protection, making it suitable for professional electricians, electronic maintenance, DIY enthusiasts, and a necessary multimeter tool for homes and factories.

For a detailed user manual in PDF format, please refer to the official document: FUZRR Digital Multimeter User Manual (PDF)

2. Safety Rules and Precautions

  • This product strictly adheres to European electrical safety standard EN61010-1 and Chinese national standard GBT13978 technical design standards.
  • Before using the instrument, please read the "Safety Precautions" and operate according to the specified safety regulations.
  • Please measure according to the specified range of the product. Do not switch gears during measurement to avoid instrument damage due to improper operation.
  • Do not touch live conductors exceeding 30V AC or 60V DC during measurement. Be careful to avoid electric shock.
  • When measuring AC and DC voltages exceeding 599V, a high voltage lightning symbol and buzzer alarm will be displayed. Please pay attention to measurement safety.
  • Do not use in flammable, explosive, or other special environments to avoid danger.
  • When the [Battery Low] symbol is displayed, replace the battery promptly to avoid measurement errors.
  • Before measuring, check the test leads for damage or leakage. If any are found, discontinue use.
  • Please comply with national regulations and safety measurement standards. When measuring voltages higher than dangerous levels, wear protective insulated gloves or flame-retardant equipment.

2.1. International Electrical Symbols

No.SymbolDescription
1⚠"Caution" indicates dangerous operation
2⚠"High Voltage" indicates dangerous high voltage warning
3CEEU unified directive, EU CE certification
4☉Grounding
5☒Double insulation or reinforced insulation protection
6♻Complies with WEEE recycling directive

3. Instrument Structure

FUZRR Digital Multimeter main components diagram with numbered callouts.
Figure 3.1: Multimeter Components Overview
No.ComponentDescription
1LCD DisplayDisplays measurement readings and symbols.
2Function ButtonsMODE/VFD, MAX/MIN, RANGE, HOLD, Backlight.
3Range Rotary SwitchSelects measurement function and range.
4VΩmA Input JackRed test lead input for Voltage, Resistance, small Current.
5COM Input JackBlack test lead input (common ground).
610A Input JackRed test lead input for high current (up to 10A).

3.1. Display Symbols Description

No.SymbolDescription
1OFFPower off
2␣Auto power off
3⚡Low battery indicator
4⎯mVDC millivolts
5⎯VDC voltage
6TRUE RMSTrue RMS measurement
7~VAC voltage
8HzFrequency
9⎯uA, mA, ADC current (microampere, milliampere, ampere)
10~uA, mA, AAC current (microampere, milliampere, ampere)
11Ω KΩ MΩResistance (Ohm, Kiloohm, Megaohm)
12♫Continuity buzzer, Diode
13nF uF mFCapacitance (nanofarad, microfarad, millifarad)
14RELRelative value clearing
15⚡Battery 1.5V/9V
16NCV EFNon-contact induced signal
17LIVEAC live wire L
18°C/°FTemperature
19☉Current clamp
20VFDAC variable frequency measurement

3.2. Button Function Description

No.Function SymbolDescription
1MODE/VFDMode switching (short press); VFD (long press 3S)
2MAX/MINMeasures maximum/minimum value
3RANGEManual range
4HOLDData hold (short press)
5✴Backlight

4. Specifications

4.1. General Specifications

  • Safety Rating: CAT II 1000V CAT III 600V
  • Product Range: Auto
  • Maximum Display: FR15B+ FR17B+ displays 6000 counts
  • Sampling Rate: 3 times/S; Over-range display OL
  • Auto Power Off: Approximately 15 minutes
  • Operating Temperature: 0-40°C
  • Accuracy: 23°C ±5°C (18-28°C; Humidity <75%); 1 year
  • Storage Temperature: -10-60°C; Humidity ≤80%
  • Altitude: 0-2000 meters
  • Pollution Degree: 2

4.2. Measurement Ranges and Accuracy

DC Voltage

RangeFR15B+FR17B+ResolutionAccuracy
60.00mV60.00mV60.00mV0.01mV±(0.5%+3)
600.0mV600.0mV600.0mV0.1mV
6.000V6.000V6.000V0.001V
60.00V60.00V60.00V0.01V
600.0V600.0V600.0V0.1V±(0.8%+5)
1000V1000V1500V1V

Input Protection: 10MΩ impedance; DC1500V; 1000Vrms

AC Voltage

RangeFR15B+FR17B+ResolutionAccuracy
6.000V6.000V6.000V0.001V±(0.8%+5) 400Hz;
±(1.2%+5) 1KHz
60.00V60.00V60.00V0.01V
600.0V600.0V600.0V0.1V
1000V1000V1000V1V
VFD (100-600V / 400Hz)True RMSTrue RMS0.1V±(4%+5)

Input Protection: 10MΩ impedance; 1000Vrms

AC Voltage Frequency

RangeFR15B+FR17B+ResolutionAccuracy
10.00Hz10.00Hz10.00Hz0.01Hz±(0.5%+5)
100.0Hz100.0Hz100.0Hz0.1Hz
1.000KHz1.000KHz1.000KHz0.001KHz
60KHz60KHz60KHz0.01KHz

Input Protection: 1000Vrms

Resistance

RangeFR15B+FR17B+ResolutionAccuracy
600.0Ω600.0Ω600.0Ω0.1Ω±(1%+5)
6.000KΩ (AUTO)6.000KΩ (AUTO)6.000KΩ (AUTO)0.001KΩ
60.00KΩ (AUTO)60.00KΩ (AUTO)60.00KΩ (AUTO)0.01KΩ
600.0KΩ (AUTO)600.0KΩ (AUTO)600.0KΩ (AUTO)0.1KΩ
6.000MΩ6.000MΩ6.000MΩ0.001MΩ±(2.5%+5)
60.00MΩ60.00MΩ60.00MΩ0.01MΩ

Input Protection: 1000Vrms

Continuity / Diode / NCV / LIVE

FunctionFR15B+FR17B+ResolutionAccuracy
Continuity0.1-30Ω0.1-30Ω0.1Ω
Diode0.500V-0.800V0.500V-0.800V0.001V
NCV50V-1000V50V-1000V0-5cm non-contact sensing
LIVE50V-1000V50V-1000VMeasures live circuits

Input Protection: 1000Vrms

DC Current

RangeFR15B+FR17B+ResolutionAccuracy
600.0uA600.0uA600.0uA0.1uA±(0.8%+5)
6.000mA (AUTO)6.000mA (AUTO)6.000mA (AUTO)0.001mA
60.00mA (AUTO)60.00mA (AUTO)60.00mA (AUTO)0.01mA
600.0mA (AUTO)600.0mA (AUTO)600.0mA (AUTO)0.1mA±(2%+5)
6.000A6.000A6.000A0.001A
10.00A10.00A10.00A0.01A

Input Protection: Fuse: 500mA/1000V; 10A/1000V; ⌀6.3x31.5mm; 10A test time max: 10S

AC Current

RangeFR15B+FR17B+ResolutionAccuracy
600.0uA600.0uA600.0uA0.1uA±(1%+5) 400Hz;
±(1.5%+5) 1KHz
6.000mA (AUTO)6.000mA (AUTO)6.000mA (AUTO)0.001mA
60.00mA (AUTO)60.00mA (AUTO)60.00mA (AUTO)0.01mA
600.0mA (AUTO)600.0mA (AUTO)600.0mA (AUTO)0.1mA±(2%+5)
6.000A6.000A6.000A0.001A
10.00A10.00A10.00A0.01A

Input Protection: Fuse: 500mA/1000V; 10A/1000V; ⌀6.3x31.5mm; 10A test time max: 10S

Temperature (FR17B+ only)

RangeFR15B+FR17B+ResolutionAccuracy
-50°C - 0°C--50°C - 0°C1°C4°C
0°C - 100°C-0°C - 100°C1°C±(1.5%+4)
100°C - 1000°C-100°C - 1000°C1°C
-58°F - 32°F--58°F - 32°F1°F5°F
32°F - 212°F-32°F - 212°F1°F±(2%+5)
212°F - 1832°F-212°F - 1832°F1°F

Input Protection: 1000Vrms

Capacitance

RangeFR15B+FR17B+ResolutionAccuracy
6.000nF6.000nF6.000nF0.001nF±(4%+5)
60.00nF60.00nF60.00nF0.01nF
600.0nF600.0nF600.0nF0.01nF
6.000uF6.000uF6.000uF0.001uF
60.00uF60.00uF60.00uF0.01uF
600.0uF600.0uF600.0uF0.1uF
6000uF6000uF6000uF0.001mF±(8%+5)
60000uF60000uF60000uF0.1mF

Input Protection: 1000Vrms

Current Clamp (AC/DC 600A)

RangeFR15B+FR17B+ResolutionAccuracy
6.0A (AD/DC)6.0A (AD/DC)6.0A (AD/DC)0.1A±(3%+5)
60.0A (AD/DC)60.0A (AD/DC)60.0A (AD/DC)0.1A
600.0A (AD/DC)600.0A (AD/DC)600.0A (AD/DC)0.1A

Input Protection: 1000Vrms; Current Clamp Output: 1A/1mV AC

Frequency

RangeFR15B+FR17B+ResolutionAccuracy
10.00Hz10.00Hz10.00Hz0.01Hz±(0.5%+5)
100.0Hz100.0Hz100.0Hz0.1Hz
1.000KHz1.000KHz1.000KHz0.001KHz
10.00KHz10.00KHz10.00KHz0.01KHz
100.0KHz100.0KHz100.0KHz0.1KHz
1.000MHz1.000MHz1.000MHz0.001MHz±(1%+5)
20.00MHz20.00MHz20.00MHz0.01MHz

Duty Cycle

RangeFR15B+FR17B+ResolutionAccuracy
10-90%10-90%10-90%0.1%±(1%+5)

Input Protection: 1000Vrms; 10Hz-100KHz/≤200mVrms; 100KHz-10MHz/≤500mVrms

5. Quick Application Guide

This section provides examples of common measurements. Always refer to the full specifications for detailed ranges and accuracy.

Measurement FunctionTest Lead ConnectionExample Application
AC Voltage/HzBlack to COM, Red to VΩAC voltage 220V, 380V/50HZ
DC VoltageBlack to COM, Red to VΩElectric vehicle lithium battery 36V, 48V, vehicle charging system
Continuity/DiodeBlack to COM, Red to VΩShort circuit buzzer, diode forward bias
ResistanceBlack to COM, Red to VΩSMD resistors, plug-in resistors, circuit impedance
CapacitanceBlack to COM, Red to VΩSMD capacitors, electrolytic capacitors
NCV/LIVERed to VΩMeasures AC voltage, live wire alarm
DC Current A uAmABlack to COM, Red to uAmAVΩ
DC Current 10ABlack to COM, Red to ASeries circuit measurement with test leads. Do not connect to AC220V.
AC Current uA mABlack to COM, Red to uAmAVΩ
AC Current 10ABlack to COM, Red to A
Current Clamp 600A (AC/DC)Black to COM, Red to VΩSelect current clamp to measure AC/DC 600A
Temperature °C/°FBlack to COM, Red to VΩAir conditioning systems, refrigeration system testing
KHzBlack to COM, Red to VΩFrequency signal measurement

6. General Maintenance

6.1. Fuse Replacement ⚠⚠

Before replacing the fuse, disconnect the test leads from the circuit to avoid electric shock.

Fuse Specifications:

  • FR15B+ FR17B+: F1: 500mA/1000V ⌀6.3x31.5mm
  • FR15B+ FR17B+: F2: 10A/1000V ⌀6.3x31.5mm

6.2. Battery Replacement ⚠⚠

Before replacing the battery, disconnect the test leads from the circuit to avoid electric shock.

Battery Specifications: LR06 • AA 1.5V × 3

To replace the battery, unscrew the battery cover as shown in the diagram below, replace the batteries, and then tighten the battery cover screws to ensure proper instrument operation.

Diagram showing how to open the battery compartment for replacement.
Figure 6.1: Battery Replacement Diagram

6.3. Repair ⚠⚠

Only qualified and experienced technical personnel should open the casing for repairs. If the product malfunction cannot be resolved, please contact official after-sales service promptly. Non-professional personnel are prohibited from operating to avoid improper repairs causing damage or electric shock.

7. Troubleshooting

If you encounter issues with your FUZRR Digital Multimeter, please refer to the following common troubleshooting steps:

  • No Display or Faint Display: Check if the batteries are installed correctly and have sufficient charge. Replace batteries if necessary.
  • Incorrect Readings: Ensure the correct measurement function and range are selected. Verify that test leads are properly connected and not damaged. Clean the test lead tips if they appear dirty.
  • No Continuity Beep: Check if the continuity function is selected and if the circuit being tested is actually closed.
  • Overload Indication (OL): This indicates that the measured value exceeds the selected range. Switch to a higher range or a different function if appropriate.
  • Instrument Not Responding: Try turning the multimeter off and on again. If the issue persists, remove the batteries for a few minutes and then reinsert them.

For persistent problems, refer to the detailed user manual (PDF) or contact customer support.

8. User Tips

  • Always start with the highest range when measuring an unknown voltage or current to prevent damage to the multimeter.
  • Utilize the 'HOLD' function to freeze the display reading, which is useful when taking measurements in hard-to-see areas.
  • The 'Auto Range' feature simplifies operation, but for very precise measurements or specific troubleshooting, manually selecting a range can sometimes provide quicker or more stable readings.
  • Keep the multimeter and test leads clean and dry to ensure accurate readings and prolong the life of the device.

9. Warranty and Support

This user manual content cannot be used as a reason for using the product for special purposes. The company is not responsible for other losses caused by use. The company reserves the right to modify the content of the user manual. If there are any modifications, no further notice will be given.

For technical support or warranty inquiries, please contact:

Guangzhou Zhengneng Electronic Technology Co., Ltd.
Address: 4th Floor, Building 6, Hongjie Industrial Park, Xingshan Middle Road, Zhongluotan Town, Baiyun District, Guangzhou
Phone: 020-37319325
Fax: 020-37319075
Zip Code: 510540
Website: www.znele.com

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.