1. Introduction
This new digital multimeter features a two-color protective casing, anti-slip ergonomic design, and a large LCD screen. It offers multi-functionality, high precision, high performance, drop resistance, safety, and stability. It can accurately measure AC/DC voltage, high voltage alarm, AC/DC current, frequency, continuity, diode, resistance, capacitance, battery load, NCV, and live wire detection. It also includes error operation circuit protection, making it suitable for professional electricians, electronic maintenance, DIY enthusiasts, and a necessary multimeter tool for homes and factories.
For a detailed user manual in PDF format, please refer to the official document: FUZRR Digital Multimeter User Manual (PDF)
2. Safety Rules and Precautions
- This product strictly adheres to European electrical safety standard EN61010-1 and Chinese national standard GBT13978 technical design standards.
- Before using the instrument, please read the "Safety Precautions" and operate according to the specified safety regulations.
- Please measure according to the specified range of the product. Do not switch gears during measurement to avoid instrument damage due to improper operation.
- Do not touch live conductors exceeding 30V AC or 60V DC during measurement. Be careful to avoid electric shock.
- When measuring AC and DC voltages exceeding 599V, a high voltage lightning symbol and buzzer alarm will be displayed. Please pay attention to measurement safety.
- Do not use in flammable, explosive, or other special environments to avoid danger.
- When the [Battery Low] symbol is displayed, replace the battery promptly to avoid measurement errors.
- Before measuring, check the test leads for damage or leakage. If any are found, discontinue use.
- Please comply with national regulations and safety measurement standards. When measuring voltages higher than dangerous levels, wear protective insulated gloves or flame-retardant equipment.
2.1. International Electrical Symbols
| No. | Symbol | Description |
|---|---|---|
| 1 | ⚠ | "Caution" indicates dangerous operation |
| 2 | ⚠ | "High Voltage" indicates dangerous high voltage warning |
| 3 | CE | EU unified directive, EU CE certification |
| 4 | ☉ | Grounding |
| 5 | ☒ | Double insulation or reinforced insulation protection |
| 6 | ♻ | Complies with WEEE recycling directive |
3. Instrument Structure

| No. | Component | Description |
|---|---|---|
| 1 | LCD Display | Displays measurement readings and symbols. |
| 2 | Function Buttons | MODE/VFD, MAX/MIN, RANGE, HOLD, Backlight. |
| 3 | Range Rotary Switch | Selects measurement function and range. |
| 4 | VΩmA Input Jack | Red test lead input for Voltage, Resistance, small Current. |
| 5 | COM Input Jack | Black test lead input (common ground). |
| 6 | 10A Input Jack | Red test lead input for high current (up to 10A). |
3.1. Display Symbols Description
| No. | Symbol | Description |
|---|---|---|
| 1 | OFF | Power off |
| 2 | ␣ | Auto power off |
| 3 | ⚡ | Low battery indicator |
| 4 | ⎯mV | DC millivolts |
| 5 | ⎯V | DC voltage |
| 6 | TRUE RMS | True RMS measurement |
| 7 | ~V | AC voltage |
| 8 | Hz | Frequency |
| 9 | ⎯uA, mA, A | DC current (microampere, milliampere, ampere) |
| 10 | ~uA, mA, A | AC current (microampere, milliampere, ampere) |
| 11 | Ω KΩ MΩ | Resistance (Ohm, Kiloohm, Megaohm) |
| 12 | ♫ | Continuity buzzer, Diode |
| 13 | nF uF mF | Capacitance (nanofarad, microfarad, millifarad) |
| 14 | REL | Relative value clearing |
| 15 | ⚡ | Battery 1.5V/9V |
| 16 | NCV EF | Non-contact induced signal |
| 17 | LIVE | AC live wire L |
| 18 | °C/°F | Temperature |
| 19 | ☉ | Current clamp |
| 20 | VFD | AC variable frequency measurement |
3.2. Button Function Description
| No. | Function Symbol | Description |
|---|---|---|
| 1 | MODE/VFD | Mode switching (short press); VFD (long press 3S) |
| 2 | MAX/MIN | Measures maximum/minimum value |
| 3 | RANGE | Manual range |
| 4 | HOLD | Data hold (short press) |
| 5 | ✴ | Backlight |
4. Specifications
4.1. General Specifications
- Safety Rating: CAT II 1000V CAT III 600V
- Product Range: Auto
- Maximum Display: FR15B+ FR17B+ displays 6000 counts
- Sampling Rate: 3 times/S; Over-range display OL
- Auto Power Off: Approximately 15 minutes
- Operating Temperature: 0-40°C
- Accuracy: 23°C ±5°C (18-28°C; Humidity <75%); 1 year
- Storage Temperature: -10-60°C; Humidity ≤80%
- Altitude: 0-2000 meters
- Pollution Degree: 2
4.2. Measurement Ranges and Accuracy
DC Voltage
| Range | FR15B+ | FR17B+ | Resolution | Accuracy |
|---|---|---|---|---|
| 60.00mV | 60.00mV | 60.00mV | 0.01mV | ±(0.5%+3) |
| 600.0mV | 600.0mV | 600.0mV | 0.1mV | |
| 6.000V | 6.000V | 6.000V | 0.001V | |
| 60.00V | 60.00V | 60.00V | 0.01V | |
| 600.0V | 600.0V | 600.0V | 0.1V | ±(0.8%+5) |
| 1000V | 1000V | 1500V | 1V |
Input Protection: 10MΩ impedance; DC1500V; 1000Vrms
AC Voltage
| Range | FR15B+ | FR17B+ | Resolution | Accuracy |
|---|---|---|---|---|
| 6.000V | 6.000V | 6.000V | 0.001V | ±(0.8%+5) 400Hz; ±(1.2%+5) 1KHz |
| 60.00V | 60.00V | 60.00V | 0.01V | |
| 600.0V | 600.0V | 600.0V | 0.1V | |
| 1000V | 1000V | 1000V | 1V | |
| VFD (100-600V / 400Hz) | True RMS | True RMS | 0.1V | ±(4%+5) |
Input Protection: 10MΩ impedance; 1000Vrms
AC Voltage Frequency
| Range | FR15B+ | FR17B+ | Resolution | Accuracy |
|---|---|---|---|---|
| 10.00Hz | 10.00Hz | 10.00Hz | 0.01Hz | ±(0.5%+5) |
| 100.0Hz | 100.0Hz | 100.0Hz | 0.1Hz | |
| 1.000KHz | 1.000KHz | 1.000KHz | 0.001KHz | |
| 60KHz | 60KHz | 60KHz | 0.01KHz |
Input Protection: 1000Vrms
Resistance
| Range | FR15B+ | FR17B+ | Resolution | Accuracy |
|---|---|---|---|---|
| 600.0Ω | 600.0Ω | 600.0Ω | 0.1Ω | ±(1%+5) |
| 6.000KΩ (AUTO) | 6.000KΩ (AUTO) | 6.000KΩ (AUTO) | 0.001KΩ | |
| 60.00KΩ (AUTO) | 60.00KΩ (AUTO) | 60.00KΩ (AUTO) | 0.01KΩ | |
| 600.0KΩ (AUTO) | 600.0KΩ (AUTO) | 600.0KΩ (AUTO) | 0.1KΩ | |
| 6.000MΩ | 6.000MΩ | 6.000MΩ | 0.001MΩ | ±(2.5%+5) |
| 60.00MΩ | 60.00MΩ | 60.00MΩ | 0.01MΩ |
Input Protection: 1000Vrms
Continuity / Diode / NCV / LIVE
| Function | FR15B+ | FR17B+ | Resolution | Accuracy |
|---|---|---|---|---|
| Continuity | 0.1-30Ω | 0.1-30Ω | 0.1Ω | |
| Diode | 0.500V-0.800V | 0.500V-0.800V | 0.001V | |
| NCV | 50V-1000V | 50V-1000V | 0-5cm non-contact sensing | |
| LIVE | 50V-1000V | 50V-1000V | Measures live circuits |
Input Protection: 1000Vrms
DC Current
| Range | FR15B+ | FR17B+ | Resolution | Accuracy |
|---|---|---|---|---|
| 600.0uA | 600.0uA | 600.0uA | 0.1uA | ±(0.8%+5) |
| 6.000mA (AUTO) | 6.000mA (AUTO) | 6.000mA (AUTO) | 0.001mA | |
| 60.00mA (AUTO) | 60.00mA (AUTO) | 60.00mA (AUTO) | 0.01mA | |
| 600.0mA (AUTO) | 600.0mA (AUTO) | 600.0mA (AUTO) | 0.1mA | ±(2%+5) |
| 6.000A | 6.000A | 6.000A | 0.001A | |
| 10.00A | 10.00A | 10.00A | 0.01A |
Input Protection: Fuse: 500mA/1000V; 10A/1000V; ⌀6.3x31.5mm; 10A test time max: 10S
AC Current
| Range | FR15B+ | FR17B+ | Resolution | Accuracy |
|---|---|---|---|---|
| 600.0uA | 600.0uA | 600.0uA | 0.1uA | ±(1%+5) 400Hz; ±(1.5%+5) 1KHz |
| 6.000mA (AUTO) | 6.000mA (AUTO) | 6.000mA (AUTO) | 0.001mA | |
| 60.00mA (AUTO) | 60.00mA (AUTO) | 60.00mA (AUTO) | 0.01mA | |
| 600.0mA (AUTO) | 600.0mA (AUTO) | 600.0mA (AUTO) | 0.1mA | ±(2%+5) |
| 6.000A | 6.000A | 6.000A | 0.001A | |
| 10.00A | 10.00A | 10.00A | 0.01A |
Input Protection: Fuse: 500mA/1000V; 10A/1000V; ⌀6.3x31.5mm; 10A test time max: 10S
Temperature (FR17B+ only)
| Range | FR15B+ | FR17B+ | Resolution | Accuracy |
|---|---|---|---|---|
| -50°C - 0°C | - | -50°C - 0°C | 1°C | 4°C |
| 0°C - 100°C | - | 0°C - 100°C | 1°C | ±(1.5%+4) |
| 100°C - 1000°C | - | 100°C - 1000°C | 1°C | |
| -58°F - 32°F | - | -58°F - 32°F | 1°F | 5°F |
| 32°F - 212°F | - | 32°F - 212°F | 1°F | ±(2%+5) |
| 212°F - 1832°F | - | 212°F - 1832°F | 1°F |
Input Protection: 1000Vrms
Capacitance
| Range | FR15B+ | FR17B+ | Resolution | Accuracy |
|---|---|---|---|---|
| 6.000nF | 6.000nF | 6.000nF | 0.001nF | ±(4%+5) |
| 60.00nF | 60.00nF | 60.00nF | 0.01nF | |
| 600.0nF | 600.0nF | 600.0nF | 0.01nF | |
| 6.000uF | 6.000uF | 6.000uF | 0.001uF | |
| 60.00uF | 60.00uF | 60.00uF | 0.01uF | |
| 600.0uF | 600.0uF | 600.0uF | 0.1uF | |
| 6000uF | 6000uF | 6000uF | 0.001mF | ±(8%+5) |
| 60000uF | 60000uF | 60000uF | 0.1mF |
Input Protection: 1000Vrms
Current Clamp (AC/DC 600A)
| Range | FR15B+ | FR17B+ | Resolution | Accuracy |
|---|---|---|---|---|
| 6.0A (AD/DC) | 6.0A (AD/DC) | 6.0A (AD/DC) | 0.1A | ±(3%+5) |
| 60.0A (AD/DC) | 60.0A (AD/DC) | 60.0A (AD/DC) | 0.1A | |
| 600.0A (AD/DC) | 600.0A (AD/DC) | 600.0A (AD/DC) | 0.1A |
Input Protection: 1000Vrms; Current Clamp Output: 1A/1mV AC
Frequency
| Range | FR15B+ | FR17B+ | Resolution | Accuracy |
|---|---|---|---|---|
| 10.00Hz | 10.00Hz | 10.00Hz | 0.01Hz | ±(0.5%+5) |
| 100.0Hz | 100.0Hz | 100.0Hz | 0.1Hz | |
| 1.000KHz | 1.000KHz | 1.000KHz | 0.001KHz | |
| 10.00KHz | 10.00KHz | 10.00KHz | 0.01KHz | |
| 100.0KHz | 100.0KHz | 100.0KHz | 0.1KHz | |
| 1.000MHz | 1.000MHz | 1.000MHz | 0.001MHz | ±(1%+5) |
| 20.00MHz | 20.00MHz | 20.00MHz | 0.01MHz |
Duty Cycle
| Range | FR15B+ | FR17B+ | Resolution | Accuracy |
|---|---|---|---|---|
| 10-90% | 10-90% | 10-90% | 0.1% | ±(1%+5) |
Input Protection: 1000Vrms; 10Hz-100KHz/≤200mVrms; 100KHz-10MHz/≤500mVrms
5. Quick Application Guide
This section provides examples of common measurements. Always refer to the full specifications for detailed ranges and accuracy.
| Measurement Function | Test Lead Connection | Example Application |
|---|---|---|
| AC Voltage/Hz | Black to COM, Red to VΩ | AC voltage 220V, 380V/50HZ |
| DC Voltage | Black to COM, Red to VΩ | Electric vehicle lithium battery 36V, 48V, vehicle charging system |
| Continuity/Diode | Black to COM, Red to VΩ | Short circuit buzzer, diode forward bias |
| Resistance | Black to COM, Red to VΩ | SMD resistors, plug-in resistors, circuit impedance |
| Capacitance | Black to COM, Red to VΩ | SMD capacitors, electrolytic capacitors |
| NCV/LIVE | Red to VΩ | Measures AC voltage, live wire alarm |
| DC Current A uAmA | Black to COM, Red to uAmAVΩ | |
| DC Current 10A | Black to COM, Red to A | Series circuit measurement with test leads. Do not connect to AC220V. |
| AC Current uA mA | Black to COM, Red to uAmAVΩ | |
| AC Current 10A | Black to COM, Red to A | |
| Current Clamp 600A (AC/DC) | Black to COM, Red to VΩ | Select current clamp to measure AC/DC 600A |
| Temperature °C/°F | Black to COM, Red to VΩ | Air conditioning systems, refrigeration system testing |
| KHz | Black to COM, Red to VΩ | Frequency signal measurement |
6. General Maintenance
6.1. Fuse Replacement ⚠⚠
Before replacing the fuse, disconnect the test leads from the circuit to avoid electric shock.
Fuse Specifications:
- FR15B+ FR17B+: F1: 500mA/1000V ⌀6.3x31.5mm
- FR15B+ FR17B+: F2: 10A/1000V ⌀6.3x31.5mm
6.2. Battery Replacement ⚠⚠
Before replacing the battery, disconnect the test leads from the circuit to avoid electric shock.
Battery Specifications: LR06 • AA 1.5V × 3
To replace the battery, unscrew the battery cover as shown in the diagram below, replace the batteries, and then tighten the battery cover screws to ensure proper instrument operation.

6.3. Repair ⚠⚠
Only qualified and experienced technical personnel should open the casing for repairs. If the product malfunction cannot be resolved, please contact official after-sales service promptly. Non-professional personnel are prohibited from operating to avoid improper repairs causing damage or electric shock.
7. Troubleshooting
If you encounter issues with your FUZRR Digital Multimeter, please refer to the following common troubleshooting steps:
- No Display or Faint Display: Check if the batteries are installed correctly and have sufficient charge. Replace batteries if necessary.
- Incorrect Readings: Ensure the correct measurement function and range are selected. Verify that test leads are properly connected and not damaged. Clean the test lead tips if they appear dirty.
- No Continuity Beep: Check if the continuity function is selected and if the circuit being tested is actually closed.
- Overload Indication (OL): This indicates that the measured value exceeds the selected range. Switch to a higher range or a different function if appropriate.
- Instrument Not Responding: Try turning the multimeter off and on again. If the issue persists, remove the batteries for a few minutes and then reinsert them.
For persistent problems, refer to the detailed user manual (PDF) or contact customer support.
8. User Tips
- Always start with the highest range when measuring an unknown voltage or current to prevent damage to the multimeter.
- Utilize the 'HOLD' function to freeze the display reading, which is useful when taking measurements in hard-to-see areas.
- The 'Auto Range' feature simplifies operation, but for very precise measurements or specific troubleshooting, manually selecting a range can sometimes provide quicker or more stable readings.
- Keep the multimeter and test leads clean and dry to ensure accurate readings and prolong the life of the device.
9. Warranty and Support
This user manual content cannot be used as a reason for using the product for special purposes. The company is not responsible for other losses caused by use. The company reserves the right to modify the content of the user manual. If there are any modifications, no further notice will be given.
For technical support or warranty inquiries, please contact:
Guangzhou Zhengneng Electronic Technology Co., Ltd.Address: 4th Floor, Building 6, Hongjie Industrial Park, Xingshan Middle Road, Zhongluotan Town, Baiyun District, Guangzhou
Phone: 020-37319325
Fax: 020-37319075
Zip Code: 510540
Website: www.znele.com