1. Product Overview
The JIKONG JK BMS V19 is an intelligent Battery Management System designed for large-capacity series lithium battery packs. It features voltage acquisition, high-current active balancing, overcharge, over-discharge, over-temperature protection, a coulomb meter, Bluetooth communication, and optional GPS and other functions. This BMS is suitable for Li-ion, LiFePo4, and LTO battery types.
It utilizes energy transfer active balancing technology with a continuous balance current of 1A/2A, ensuring battery consistency, improving battery range, and delaying battery aging. The system is controlled via a mobile APP (Android and iOS) connected via Bluetooth, allowing users to monitor battery status, modify parameters, and control charge/discharge switches.
The protection board is compact, easy to operate, and versatile, making it ideal for battery packs in small sightseeing vehicles, mobility scooters, shared cars, high-power energy storage systems, base station backup power supplies, and solar power stations.
2. Key Features
- LED Bluetooth status indicator
- APP remote operation (Android/iOS/Harmony OS support)
- Battery capacity calculation
- High precision voltage and current acquisition
- Support information screen display
- Accurate time logging
- Active Balanced BMS (1A/2A active current)
- Overcharge Protection, Over Discharge Protection, Overcurrent Protection, Short Circuit Protection
- Over Temperature Protection, Low Temperature Protection
- Optional features: RS485, CAN, ACC detection, Heating function, Parallel function, Alarm function, GPS communication
3. Setup & Installation
3.1. Package Contents
Before installation, please verify all components are present:

Image: Package contents for the JIKONG BMS, showing the main board, instruction manual, four screws, a switch (50cm), an NTC temperature sensor (40cm), a CAN cable (25cm), and two sets of wires (70cm).
3.2. Physical Dimensions
The dimensions of the JK-BxA8S-20P series protection board are 152.25mm × 127.26mm × 15.6mm.

Image: Technical drawing showing the precise dimensions of the JIKONG JK-BxA8S-20P BMS, including length, width, and thickness, along with mounting hole positions.
3.3. Interface Definition
The BMS features various ports for connection to the battery, external modules, and communication interfaces. Refer to the diagram below for port identification.

Image: Close-up view of the JK-B2A8S20P-HC BMS showing labeled ports for Heating Cable, NTC, UART/GPS, RS485/CAN, ACC, Display/Switch, and Sampling Port.
3.4. Wiring Diagram
The JK-BxA8S-20P series protection board is suitable for 3-8 series lithium battery packs. The specific wiring method depends on the number of cells in the battery pack. Ensure all connections are secure and correct before powering on the BMS.

Image: Detailed wiring diagram illustrating how to connect the BMS to a battery pack, load, and charger. It shows connections for total positive pole (B+), sampling cables for each string (B1 to B8), total negative electrode (B-), and connections to the load and charger.
3.5. Device Activation
Before starting the protection board, ensure the balance cable is properly connected and that P- and B- are correctly connected. Verify the protection board is securely fixed to the battery core. Incorrect connections can lead to abnormal operation or damage.
The BMS does not have a power-on control switch. It is designed for charging activation mode, meaning the charger voltage must be 2V higher than the battery voltage. After battery assembly, connect the charger to activate the protection board.
Alternatively, the BMS supports key activation and display activation. If you have a display screen and button, insert the cable into the display interface and press the button to activate.
4. Operating Instructions
4.1. APP Installation & Connection
The JIKONG BMS can be controlled via a mobile application. For iOS devices, search for "JIKONG BMS" in the APP Store. For Android devices, search for "JK BMS" in the Google Store.
After installation, turn on GPS and Bluetooth on your mobile phone. Ensure Bluetooth is active, then open the APP. Click the top-left corner to search for devices. Select your device from the list and connect using the default password: 1234.

Image: Screenshot of the JIKONG Smart BT APP displaying real-time battery data, including charge/discharge status, voltage, current, and individual cell voltages, along with control options.
4.2. Parameter Settings
For the first startup, parameters need to be set. The default password for parameter settings is 123456. You will need to set the number of units (battery strings) and the battery type (Li-ion, LiFePo4, or LTO).
After setting the parameters, return to the real-time status page to check the battery status. Ensure no error messages are prompted and the system operates normally. In the display, blue indicates the highest voltage, and red indicates the lowest voltage.
4.3. Active Balancing
The BMS uses active balancing to transfer energy from high-voltage cells to low-voltage cells. Users can set the balance trigger pressure difference (in mV) in the APP. When the voltage difference between any two battery strings exceeds the set value, balancing automatically activates. It deactivates when the difference falls below the set value. The default balance current is 1A/2A. It is recommended that the balance current does not exceed 0.2C of the battery capacity. If balancing is not required, it can be switched off in the BMS control page of the APP.
4.4. Heating Function
The optional heating function allows the BMS to heat the battery at low temperatures using a resistance heater or heating film. This prevents charging and discharging failures due to reduced battery activity in cold conditions. The designed heating current is 20A. Users can switch this function on/off via the APP. It is recommended to use a normally closed temperature switch (45°C to 65°C) in series with the heating circuit for secondary protection.
4.5. Alarm Function
The optional alarm function provides external alerts when the BMS detects safety risks such as overtemperature, overcharge, or overdischarge.
4.6. Battery Parallel Function
The optional parallel function supports connecting multiple battery packs for energy storage applications. This function requires a parallel module and the "disable charging current limiting" function to be turned off in the APP.
4.7. ACC Detection Function
The optional ACC detection function enables discharge. It can be activated by applying a voltage between ACC+ and ACC- (20V-100V) or by directly short-circuiting ACC+ and ACC-. A charger detection function (C_detect+ and C_detect-) is also available for enabling charging.
5. Protection Features
The JIKONG BMS provides comprehensive protection for your battery pack:
5.1. Charge Overvoltage Protection
The BMS includes standard charge overvoltage protection. Users can set the single overcharge protection voltage and recovery voltage in the APP. If any cell exceeds the set voltage during charging, the BMS will stop charging. Charging resumes when all cells fall below the recovery voltage.
5.2. Discharge Undervoltage Protection
Standard discharge undervoltage protection is provided. Users can set the undervoltage protection voltage, recovery voltage, and automatic shutdown voltage in the APP. If any cell drops below the protection voltage during discharge, the BMS will stop discharging. Discharge resumes when all cells are above the recovery voltage. If any cell drops below the automatic shutdown voltage, the BMS will shut down to protect the battery.
5.3. Charge Overcurrent Protection
Standard charge overcurrent protection is included. Users can set the continuous charging current, overcurrent delay, and recovery time in the APP. If the charging current exceeds the set value for the specified delay, charging will stop. It resumes after the recovery time.
5.4. Discharge Overcurrent Protection
Standard discharge overcurrent protection is included. Users can set the continuous discharge current, overcurrent delay, and recovery time in the APP. If the discharge current exceeds the set value for the specified delay, discharging will stop. It resumes after the recovery time. Note: The maximum continuous discharge current should not exceed 200A.
5.5. Over Temperature Protection
The BMS features standard charge and discharge overtemperature protection. Users can set the protection and recovery temperatures in the APP. If the temperature exceeds the set value, the corresponding operation (charge/discharge) will stop and resume when the temperature falls below the recovery value.
5.6. Low Temperature Protection
Standard charge low temperature protection is included. Users can set the protection and recovery temperatures in the APP. If the temperature falls below the set value, charging will stop and resume when the temperature rises above the recovery value. For extremely cold environments, using the optional heating function is recommended.
5.7. Short Circuit Protection
Standard short circuit protection is provided. Users can set the short circuit protection delay and recovery time in the APP. The current that triggers short circuit protection does not need to be set manually. If a short circuit occurs during initial connection or operation, increasing the delay time can help prevent false triggers due to peak currents from chargers or capacitive loads.
5.8. Emergency Switch
The BMS includes a standard emergency switch function. If issues like overtemperature, overdischarge, overcharge, or cell string drops occur, activating the emergency switch in the APP will enable charge and discharge for 30 minutes, providing emergency use time. The BMS will continue to operate until the 30-minute cycle ends, even if a single cell reaches the automatic shutdown voltage.
5.9. Intelligent Sleep
The BMS is equipped with an intelligent sleep function. Users can enable or disable it in the APP. This function closes the protection board when it's in standby (charging/discharging current less than 1A for 26 consecutive hours) to reduce self-consumption. It can be reactivated via a button or by connecting the charger.
6. Specifications
6.1. Basic Parameters
| Parameter | Value | Unit |
|---|---|---|
| Supply Voltage | 7.5-36 | V |
| Operating Power Consumption | <900 | mW |
| Operating Temperature | -30-70 | °C |
| Max Number of Collection Strings | 8 | String |
| Max Balancing Current | 1A / 2A | A |
| Max Charging Current | 200 | A |
| Max Discharge Current | 200 | A |
| Max Instantaneous Current | 400 | A |
| Max Internal Loop Resistance | 0.35 | mΩ |
| Protective Plate Size | 152.25*127.26*15.6 | mm |
| Finished Weight | 424 | g |
6.2. Default Parameters (Example for LiFePo4)
| Parameter | LiFePo4 Default | Unit |
|---|---|---|
| Balancing Initial Voltage | 3 | V |
| Max Balancing Current | 1A / 2A | A |
| Unit Overcharge Voltage | 3.6 | V |
| Single Overcharge Protection Recovery | 3.55 | V |
| Monomer Undervoltage Protection | 2.6 | V |
| Single Undervoltage Protection Recovery | 2.65 | V |
| Automatic Shutdown Voltage | 2.5 | V |
| Trigger Balancing Differential Pressure | 0.01 | V |
| Charging Overcurrent Protection Delay | 30 | S |
| Charging Overcurrent Protection Release Time | 60 | S |
| Discharge Overcurrent Protection Delay | 300 | S |
| Discharge Overcurrent Protection Release Time | 60 | S |
| Short-circuit Protection Delay | 5 | uS |
| Charging Overtemperature Protection | 70 | °C |
| Charging Overtemperature Restore Temperature | 60 | °C |
| Discharge Overtemperature Protection | 70 | °C |
| Discharge Overtemperature Recovery | 60 | °C |
| Charging Low Temperature Protection | -20 | °C |
| Charging Low Temperature Restore Temperature | -10 | °C |
| MOS Overtemperature Protection | 100 | °C |
| MOS Overtemperature Recovery | 80 | °C |
7. Troubleshooting
If you encounter issues with your JIKONG BMS, consider the following:
- Connection Check: Ensure all balance cables, P-, and B- connections are secure and correctly wired according to the diagram. Loose connections are a common cause of errors.
- Activation: Verify the BMS has been properly activated (either by charger voltage or emergency switch/button).
- APP Connectivity: Confirm your mobile device's Bluetooth is on and the APP is successfully connected to the BMS. Try restarting the APP or your phone's Bluetooth.
- Parameter Settings: Double-check that the correct number of strings and battery type are set in the APP parameters. Incorrect settings can lead to protection triggers or inaccurate readings.
- Protection Triggers: If the BMS enters a protection state (e.g., overvoltage, undervoltage, overcurrent), check the battery cells for anomalies. The APP will display the specific protection activated.
- Temperature Issues: If operating in extreme temperatures, ensure the heating function (if installed) is working correctly or that the battery is within its safe operating temperature range.
- Short Circuit: If short circuit protection is triggered, first ensure there is no actual short circuit in your wiring or load. Adjusting the short circuit delay in the APP might help with high inrush current loads.
For complex issues, refer to the full PDF user manual for detailed troubleshooting steps or contact JIKONG customer support.
8. User Tips
- Initial Setup: Always perform a thorough check of all wiring before applying power to the BMS. Incorrect wiring can cause damage.
- APP Monitoring: Regularly use the JIKONG APP to monitor your battery's health, especially individual cell voltages, to catch potential issues early.
- Parameter Customization: Take advantage of the APP's parameter settings to fine-tune the BMS to your specific battery pack and usage scenario for optimal performance and longevity.
- Firmware Updates: Check the official JIKONG website or APP for any available firmware updates to ensure your BMS has the latest features and bug fixes.
- Temperature Management: Pay attention to battery temperature, especially in cold climates. Utilize the heating function if your battery pack is exposed to low temperatures to maintain performance and prevent damage.
9. Certifications
The JIKONG BMS has obtained the following product certifications, ensuring quality and compliance with international standards:
- RoHS: Restriction of Hazardous Substances
- FCC: Federal Communications Commission
- CE: Conformité Européenne

Image: Display of JIKONG BMS product certifications, including RoHS, FCC, and CE certificates, indicating compliance with relevant safety and environmental standards.
10. Product Video
Watch this video for a visual demonstration of the JIKONG Active Balance BMS features, including 24-hour detection, real-time automatic balancing, smart management via APP, compatibility with various battery string numbers, and its 6 major protection functions.
Video: JIKONG Active Balance BMS demonstration, highlighting its balancing capabilities, smart control, compatibility with different battery configurations, and comprehensive protection features.
11. Further Information
A detailed PDF user manual is available for download. This document contains comprehensive information on product specifications, interface definitions, and advanced parameter settings. You can access it via the following link: JIKONG BMS User Manual (PDF).
12. Support
For any technical assistance, questions, or support regarding your JIKONG BMS, please contact the seller or refer to the official JIKONG documentation. Ensure you provide your product model and any relevant details for efficient support.