1. Safety Warnings and Cautions
Please read all manuals before installing. Only qualified professionals should install these controllers.
- Keep the controller away from water. Do not use a wet towel to wipe the controller.
- Ensure correct wiring; do not reverse wiring. Pay close attention to the terminal wiring sequence.
- Operate the controller in an environmental temperature range of -20°C to +55°C. Avoid direct sunlight.
- Ensure good heat dissipation around the controller.
- Use pure copper wires and connect all polarities correctly.
- The load output is only for DC loads less than 5A current.
- Do not set any parameters if you are not a professional, as the controller works fine in default conditions (except for lithium batteries).
- Important Note: The output terminal is for lamps only (12V system less than 60W, 24V/36V/48V system less than 100W). Connecting to other loads will cause damage. The battery output does not have reverse polarity protection.

2. Main Features
- 60A MPPT solar charge controller
- Intelligent Maximum Power Point Tracking (MPPT) technology
- Built-in DSP controller with high performance
- Automatic battery voltage detection for 12V/24V/36V/48V systems
- Three-stage charging optimizes battery performance
- Multi-function LCD display for easy monitoring
- Overcharge protection and over-temperature protection
- Reverse polarity protection for solar panels
- Suitable for various battery types: sealed lead acid, vented gel, and lithium batteries
- Easy to mount and install

3. Package Contents
Please check the package contents upon receipt:
- 1 x ANENJI MPPT Solar Charge Controller (60A)
- 1 x User Manual (English)
4. Setup and Installation
4.1. Air Circuit Breaker and Wires Requirement
| Item | Requirement |
|---|---|
| Models | Icharger MPPT |
| Copper Wires | 6mm² x 2PCS |
| Air Circuit Breakers | 100A |
4.2. Wire Connection Sequences
For the ICharger MPPT, it is recommended to connect two wires to two PV+ terminals and another two wires to two PV- terminals. The same method applies to BAT+ and BAT- connections.
4.3. Installation Steps
- Ensure the battery voltage is above 12V for the controller to boot up. Install an air circuit breaker between the controller and batteries. Turn off this circuit breaker, then connect the batteries to the controller with correct polarity.
- Install an air circuit breaker between the controller and PV modules. Turn off this circuit breaker, ensure the PV polarity is correct, then connect wires between the PV modules and the controller.
- Turn on the air circuit breaker between the controller and batteries.
- Turn on the air circuit breaker between the controller and PV modules.


5. Operation
5.1. LCD Display Indication
The multi-function LCD provides real-time system status. Use the navigation buttons to cycle through different display menus.

Display Introduction:
- Menu1: Battery Voltage & Charge Current
- Menu2: Battery SOC & Charge KW
- Menu3: PV Voltage & Temperature
- Menu4: Battery Type & System Voltage
- Menu5: Load Mode (e.g., 7H for 7 hours)
- Menu6: Error & Charge State
5.2. Press Key Operation
The controller features three buttons: ENTER, Up Arrow (▲), and Down Arrow (▼), and ESC.
| Function Key | System Mode | Operation | Operation Indication |
|---|---|---|---|
| ENTER | View Mode | Long Press | Enter SET mode |
| Short Press (▲) | Screen page up | ||
| Short Press (▼) | Screen page down | ||
| Short Press (ESC) | - | ||
| ENTER | Setting Mode | Long Press | Exit from setting & saving the present settings data |
| Short Press | Enter the next setting page | ||
| Short Press (▲) | Adjust the parameter by increase the value | ||
| Short Press (▼) | Adjust the parameter by decrease the value | ||
| Short Press (ESC) | Exit SET Mode without saving data |

5.3. Battery Type Setting
Navigate to the battery type setting menu to select the appropriate battery chemistry. Options include LI (Lithium), USE (User-defined), FLd (Flooded), GEL, and SEL (Sealed).

5.4. System Voltage Setting
Set the system voltage (12V, 24V, 36V, 48V) or select AUTO for automatic detection. This setting is crucial for proper operation.
5.5. Parameter Setting
Advanced parameters can be adjusted for specific battery types (USE, LI, SEL/GEL/FLD). These include EQU Charge Volt, BST Charge Volt, FLD Charge Volt, BST-R Charge Volt, LRV Charge Volt, and LDV Charge Volt. Refer to the detailed manual pages for specific values and adjustment procedures.
| Battery Type | System Volt | EQU | BST | FLD | BST_R | LRV | LDV |
|---|---|---|---|---|---|---|---|
| GEL | Auto | --- | 14.2V | 13.8V | 13.2V | 12.6V | 11.1V |
| SEL | Auto | 14.6V | 14.4V | 13.8V | 13.2V | 12.6V | 11.1V |
| FLD | Auto | 14.8V | 14.6V | 13.8V | 13.2V | 12.6V | 11.1V |
| USE | Auto/12/24/36/48 | Defined by GEL | |||||
| LI | 12/24/36/48 | Defined by GEL | |||||

5.6. Working Mode
The controller operates in different modes depending on the solar input and battery state.
| Code | Working Mode |
|---|---|
| 3.0 | Night mode, no charging |
| 4.0 | MPPT mode |
| 7.0 | Absorption mode |
| 8.0 | Floating mode |
6. Maintenance
- Regularly inspect all wiring connections for tightness and corrosion.
- Keep the controller clean and free from dust and debris. Use a dry cloth for cleaning.
- Ensure adequate ventilation around the controller to prevent overheating. Check that the cooling fan (if present) is operating correctly.
- Monitor the LCD display for any error codes or unusual readings.
7. Troubleshooting
7.1. Error Codes
If an error occurs, an error code will be displayed on the LCD. Refer to the table below for common error codes and their meanings.
| Code | Error |
|---|---|
| E00 | No Error |
| E01 | Battery over voltage |
| E02 | PV over voltage |
| E08 | Over-discharge |
| E20 | Device over heating |

8. Specifications
| Item | Parameter |
|---|---|
| Models | Icharger MPPT |
| Charging mode | 3-stage: constant current (MPPT), constant voltage, floating |
| System voltage | 12/24/36/48V Auto |
| Max PV input power | 720W/12V; 1440W/24V; 2160W/36V; 2880W/48V |
| Max PV input voltage | 180 Voc |
| Battery voltage automatic recognition | 12V system (DC8.7V-DC15.5V); 24V system (DC16V-DC31V); 36V system (DC33V-DC41V); 48V system (DC42V-DC64V) |
| Overcharging protection voltage | 12V system (16V); 24V system (32V); 36V system (48V); 48V system (64V) |
| Limited current protection | 61A |
| Max efficiency | ≥98.1% |
| PV utilization | ≥99% |
| Auto Temperature Compensation | -3mV/2V/°C |
| Protection Function | |
| Temperature protection | 80°C |
| Fan-on temperature | >45°C |
| Fan-off temperature | <40°C |
| Properties | |
| Size (mm) | 214 x 115 x 50 |
| Net weight (Kg) | 1.1 |
| Gross weight (Kg) | 1.2 |
| Electromagnetic compatibility | Accord to EN61000, EN55022, EN55024 |
| Enclosure | IP21 |
| Environmental temperature | -20°C ~ +55°C |
| Storage temperature | -40°C ~ +75°C |


9. User Tips
- Immediate Testing: It is highly recommended to test the controller immediately upon receipt to ensure it is fully functional.
- Mode Monitoring: If using Lithium batteries, pay close attention to the working mode transitions (e.g., from 'Floating mode' 8.0 to 'MPPT mode' 4.0) in the morning. If the mode does not change automatically and charging does not start, manual intervention or further investigation into settings may be required.
10. Warranty and Support
For warranty claims or technical support, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase.