1. Introduction
Thank you for choosing the ANENJI 60A MPPT Solar Charge Controller. This device is designed to efficiently manage power from your solar panels to charge your batteries, ensuring optimal performance and longevity of your solar power system. This manual provides essential information for the safe installation, operation, and maintenance of your controller.
For a complete reference, you may also consult the official user manual PDF: ANENJI MPPT Solar Charging Controller Product Manual (PDF).
2. Safety Information, Warnings, and Cautions
Please read all instructions carefully before installation and operation to prevent damage to the controller, batteries, or other components, and to ensure personal safety.
- Professional Installation: Only qualified professionals should install these controllers.
- Water Exposure: Keep the controller away from water. Do not use wet towels to wipe the controller.
- Wiring: Ensure all wiring is correct and pay close attention to terminal wiring sequence. Do not reverse wiring.
- Environmental Temperature: Operate the controller within an environmental temperature range of -20°C to +55°C. Avoid direct sunlight exposure.
- Heat Dissipation: Maintain good heat dissipation around the controller. Ensure adequate airflow.
- Wiring Material: Use pure copper wires for all connections and ensure all polarities are connected correctly.
- Load Output: The load output terminal is designed for DC loads less than 5A current. Specifically, for lamps only (12V system less than 60W, 24V/36V/48V system less than 100W). Connecting to other loads or exceeding these limits will damage the controller.
- Battery Output Polarity: The output for the battery does not have polarity reverse protection. Ensure correct polarity when connecting batteries.
- Parameter Settings: Do not adjust any parameters if you are not a professional, as the controller operates effectively in its default condition, except for lithium batteries which may require specific configuration.
- Screw Usage: Use only the provided screws for mounting. Using other screws or applying excessive torque can damage the internal PCB.
3. Product Features
- 60A MPPT Solar Charge Controller
- Intelligent Maximum Power Point Tracking (MPPT) technology for optimal energy harvest
- Built-in DSP controller with high performance
- Automatic battery voltage detection for 12V/24V/36V/48V systems
- Three-stage charging (constant current, constant voltage, floating) optimizes battery performance and extends battery life
- Multi-function LCD display for system status monitoring
- Overcharge protection and over-temperature protection
- Reverse polarity protection for solar panels
- Suitable for various battery types: sealed lead acid, vented, gel, NiCd, and lithium batteries
- Easy to mount and install
Image: Key product characteristics including MPPT technology, various protections, and battery compatibility.
4. Setup and Installation
4.1. Air Circuit Breaker and Wires Requirement
| Item | Requirement |
|---|---|
| Models | Icharger MPPT |
| Copper Wires | 6mm² x 2PCS |
| Air Circuit Breakers | 100A |
4.2. Wire Connection Sequences
For the ICharger MPPT, it is recommended to connect two wires to each PV+ terminal and two wires to each PV- terminal. The same method applies to BAT+ and BAT- connections.
Image: General wiring diagram showing PV Array connected to the controller, which then connects to the battery and an inverter/load.
Image: Detailed terminal block diagram showing connections for PV+, PV-, BAT+, BAT-, LOAD+, and LOAD-.
4.3. Installation Steps
- Ensure the battery voltage is above 12V for the controller to boot up. Install an air circuit breaker between the controller and the batteries. Turn off this circuit breaker. Connect the batteries to the controller, ensuring correct polarity.
- Install an air circuit breaker between the controller and the PV modules. Turn off this circuit breaker. Ensure the PV polarity is correct. Connect the wires between the PV modules and the controller.
- Turn on the air circuit breaker connected between the controller and the batteries.
- Turn on the air circuit breaker connected between the controller and the PV modules.
5. Operating Instructions
5.1. LCD Display Introduction
The multi-function LCD display provides real-time information about your solar system. Navigate through the menus using the control buttons.
- Menu 1: BAT Volt & Charge Curr (Battery Voltage and Charging Current)
- Menu 2: BAT SOC & Charge KW (Battery State of Charge and Charging Kilowatts)
- Menu 3: PV Volt & Temp (PV Voltage and Controller Temperature)
- Menu 4: BAT Type & SYS Volt (Battery Type and System Voltage)
- Menu 5: Load Mode (Load Operating Mode)
- Menu 6: ERROR & Charge State (Error Codes and Charging Status)
5.2. Press Key Operation
The controller features three buttons: ENTER, UP (▲), and DOWN (▼), and ESC. Their functions vary depending on the mode.
Image: Table detailing button functions in View Mode and Setting Mode.
| Function Key | System Mode | Operation | Operation Indication |
|---|---|---|---|
| ENTER | View Mode | Long Press | Enter SET mode |
| Short Press (▲) | Screen page up | ||
| Short Press (▼) | Screen page down | ||
| Setting Mode | Long Press | Exit from setting & saving the present settings data | |
| Short Press (ENTER) | Enter the next setting page | ||
| Short Press (▲/▼) | Adjust the parameter by increase/decrease the value | ||
| ESC | View/Setting Mode | Short Press | Exit SET Mode without saving data (or no function in View Mode) |
5.3. Battery Type Setting
The controller supports various battery types. You can select from LI (Lithium), USE (User-defined), FLd (Flooded), SEL (Sealed), and GEL. Navigate to the battery type setting menu and select the appropriate type for your system.
Image: Visual representation of compatible battery types: Sealed lead-acid, Exhaust gel, and Lithium battery.
5.4. System Voltage Setting
The controller automatically detects system voltage (12V/24V/36V/48V). However, you can manually set it to AUTO, 12V, 24V, 36V, or 48V if needed, especially when using the 'USE' battery type.
5.5. Parameter Setting
Advanced users can adjust various charging parameters for specific battery types (USE, LI, SEL/GEL/FLD). These parameters include Equalization Charge Voltage (EQU), Boost Charge Voltage (BST), Float Charge Voltage (FLD), Boost-Return Voltage (BST_R), Low Voltage Reconnect (LRV), and Low Voltage Disconnect (LDV).
Caution: All steps for manual setting must be carried out when the PV modules are disconnected from the controller.
| Battery Type | System Volt | EQU | BST | FLD | BST_R | LRV | LDV |
|---|---|---|---|---|---|---|---|
| GEL | Auto | --- | 14.2V | 13.8V | 13.2V | 12.6V | 11.1V |
| SEL | Auto | 14.6V | 14.4V | 13.8V | 13.2V | 12.6V | 11.1V |
| FLD | Auto | 14.8V | 14.6V | 13.8V | 13.2V | 12.6V | 11.1V |
| USE | Auto/12/24/36/48 | Defined by GEL (user-configurable) | --- | ||||
| LI | 12/24/36/48 | Defined by GEL (user-configurable) | --- | ||||
5.6. Working Modes
| Code | Working Mode |
|---|---|
| 3.0 | Night mode, no charging |
| 4.0 | MPPT mode |
| 7.0 | Absorption mode |
| 8.0 | Floating mode |
6. Maintenance
- Cleaning: Periodically clean the controller's exterior with a dry cloth. Do not use wet cloths or solvents.
- Connections: Regularly check all wiring connections to ensure they are tight and free from corrosion.
- Heat Dissipation: Ensure the controller's ventilation openings are clear of dust and debris to maintain proper heat dissipation. The fan will activate when the internal temperature exceeds 45°C and turn off below 40°C.
- Environment: Keep the controller in a dry, well-ventilated area, away from direct sunlight and corrosive gases.
7. Troubleshooting
The controller's LCD display will show error codes if a fault occurs. Refer to the table below for common error codes and their meanings.
| Code | Error |
|---|---|
| E00 | No Error |
| E01 | Battery over voltage |
| E02 | PV over voltage |
| E08 | Over-discharge |
| E20 | Device over heating |
8. Specifications
| Item | Parameter |
|---|---|
| Models | Icharger MPPT |
| Charging Mode | 3-stage: constant current (MPPT), constant voltage, floating |
| System Voltage | 12V/24V/36V/48V Auto |
| Max PV Input Power | 720W/12V; 1440W/24V; 2160W/36V; 2880W/48V |
| Max PV Input Voltage | 180 Voc |
| Battery Voltage Automatic Recognition | 12V system (DC8.7V-DC15.5V); 24V system (DC16V-DC31V); 36V system (DC33V-DC41V); 48V system (DC42V-DC64V) |
| Overcharging Protection Voltage | 12V system (16V); 24V system (32V); 36V system (48V); 48V system (64V) |
| Limited Current Protection | 61A |
| Max Efficiency | ≥98.1% |
| PV Utilization | ≥99% |
| Auto Temperature Compensation | -3mV/2V/°C |
| Temperature Protection | 80°C |
| Fan-on Temperature | >45°C |
| Fan-off Temperature | <40°C |
| Size (mm) | 214 x 115 x 50 |
| Net Weight (Kg) | 1.1 |
| Gross Weight (Kg) | 1.2 |
| Electromagnetic Compatibility | Accord to EN61000, EN55022, EN55024 |
| Enclosure | IP21 |
| Environmental Temperature | -20°C ~ +55°C |
| Storage Temperature | -40°C ~ +75°C |
Image: Dimensional diagram showing the controller's width (115mm), height (214mm), and depth (50mm).
9. User Tips
- Inspect Upon Arrival: Carefully inspect the product and its packaging immediately upon receipt for any signs of damage, missing parts, or water exposure. Report any issues to the seller promptly.
- Verify Connections: Double-check all wiring connections before powering on the system to prevent damage from incorrect polarity or loose terminals.
10. Warranty and Support
ANENJI products are manufactured to high-quality standards. For any technical support or warranty inquiries, please contact your point of purchase or the official ANENJI support channels. Please retain your proof of purchase for warranty claims.