MYOSLIM Soprano Titanium Ice 4 IN1 Platinum RF Diode Laser Machine

Contents

Soprano Titanium Ice 4 IN1 Platinum RF Diode Laser Machine User Manual

Model: Soprano Titanium Ice 4 IN1 Platinum RF Diode Laser Machine

Brand: MYOSLIM

1. Introduction

The Soprano Titanium Ice 4 IN1 Platinum RF Diode Laser Machine is a versatile beauty device integrating four core functions: hair removal, picosecond laser for tattoo and pigment removal, RF radio frequency for anti-aging and skin tightening, and IPL for hair removal and skin rejuvenation. This advanced system is designed to provide safe, effective, and comfortable treatments for a wide range of aesthetic concerns.

It utilizes selective photothermodynamics for hair removal, targeting hair follicles with precise laser wavelengths (755nm, 808nm, 940nm, 1064nm) while protecting the epidermis with advanced cooling technology. The device features a unique pre-ignition function to ensure stable energy output and extended lifespan of the laser bar. With its multifunctional capabilities and user-friendly interface, it offers a comprehensive solution for professional beauty treatments.

Soprano Titanium Ice 4 IN1 Platinum RF Diode Laser Machine
Front view of the Soprano Titanium Ice 4 IN1 Platinum RF Diode Laser Machine.
Multifunctional 4-in-1 device with before/after results
The multifunctional capabilities of the device, showing before and after results for hair removal, skin tightening, and acne treatment.
Demonstration video of the Soprano Titanium Ice 4 IN1 Platinum RF Diode Laser Machine's interface and operation.

2. Specifications

2.1 Technical Parameters

AttributeValue
Voltage20V-50V
Efficacy Principle of EpilatorLaser/IPL/Radio Frequency
Number of Lamp Heads1 (or 5 or more pieces for some configurations)
Power TypeElectric
Power SourceElectric
Use AreasBODY, Underarm, Bikini, Whole Face
Item TypeEpilator
CertificationRoHs, CE, RoHS
Product FunctionsHair Removal, Skin Rejuvenation 4 in 1, Anti-Puffiness, Pigment Removal, Skin Tightening, Dark Circles, Face Lift, Pigmentation Correctors
Epilator TypeLaser, Diode Laser
Screen Size15.6-inch color touch 4K display
Power5000W
Skin Color SuitabilitySuitable for all skin tones
Diode Laser Wavelengths808nm/755nm/940nm/1064nm
Cooling SystemAir Cooling, Water
Frequency1-10hzs
Replacement Heads (Pico Laser)1320nm/1064nm/532nm/No scars 532nm/No scars 1064nm
Laser TypePico Laser
Pulse Width1-500 ms (adjustable)
Filter AlexSapphire Filter
Shot Count60 Million

2.2 System Principle

System Principle Diagram
Diagram illustrating the internal components and control flow of the 808 Ice Hair Removal System, including the LCD control panel, air switch, solid state relay, system control panel, handle (laser, optical mode, TEC), Q-Switch, water pump, fan, flow sensor, banner, and external protection.

3. Setup Instructions

3.1 Adding Water

First, add water to the machine. For the 808nm freezing point hair removal instrument, it is recommended to use steamed water and pure water. Do NOT use tap water or mineral water. Deionized water is preferred if available.

3.2 Connecting Power

Connect the power cord. Ensure you check the input part; the machine is designed for 220V and 110V. Do not connect incorrectly. Once the power supply is connected, rotate the key. The machine will enter the power-on interface after three seconds. Tap and press to proceed.

Hair Removal Process Diagram
Diagram illustrating the hair removal process: laser light exposure, melanin absorption and heating, leading to hair root loss and inhibited growth.

4. Operating the Device

4.1 User Interface Overview

The device features a 15.6-inch color touch 4K display for easy operation. The main interface allows selection of different treatment modes and adjustment of parameters.

Device front view with screen
Front view of the device highlighting the touch screen interface.

4.2 Mode Selection and Parameter Adjustment

From the main screen, you can select various functions such as Sweep Mode, Point-to-Point, Pico Laser, and RF Radio Frequency. For hair removal, you can choose between SHR (Super Hair Removal) Stack, SHR, and HR (Hair Removal) modes.

The interface allows selection of skin type (I-VI) and body parts (S, M, L, XL) to be treated. Parameters like Fluence (J/cm²), Pulse (ms), Frequency (Hz), and Energy (J) can be adjusted. The system also displays cooling status and treatment count.

Function selection screen
The function selection screen showing options for Sweep Mode, Point-to-Point, Pico Laser, and RF Radio Frequency.

4.3 Hair Removal Process

  1. Application of Cold Gel: Clean the treatment area and apply a cold gel containing hair inhibiting ingredients.
  2. Irradiation: Customers should wear goggles. Complete the hair removal session with 3 minutes of painless irradiation.
  3. Cool Off: Wipe off the cold gel and use a cooling pack to apply cold to the skin. Apply a calming, moisturizing lotion after treatment.

The hair removal operation is performed by pressing the handle button or foot pedal to emit light. To pause, press the button to stop working and enter standby mode.

4.4 808 Diode Laser Hair Removal - Pre-Ignition Function

The device incorporates a pre-ignition function. Before delivering high-energy output, it performs a low-power pre-activation to stabilize the laser system. This improves laser output stability, protects the laser bar, enhances continuous emission performance, and reduces failure rates, ensuring a more stable and effective treatment.

808 Diode Laser Hair Removal - Pre-Ignition Function Diagram
Detailed workflow diagram of the 808 Diode Laser's pre-ignition function, showing the transition from standby to low-power pre-activation to stabilize the laser, and then to normal emission for high-power output. It highlights benefits like improved laser output stability, protection of the laser bar, enhanced continuous emission performance, and reduced failure rate.

4.5 Picosecond Laser Operation

The picosecond laser utilizes a light blasting effect where high-intensity laser penetrates the epidermis to reach pigment clusters in the dermis. The short-duration, high-energy pulses cause pigment clusters to expand and explode instantly, which are then metabolized naturally by the body. This function is effective for removing freckles, washing eyebrows, tattoo removal, and fading acne scars and birthmarks without scarring.

Picosecond Laser Working Principle
Diagram illustrating the working principle of the Picosecond Laser, showing melanin granules absorbing laser energy and being instantaneously blasted into smaller fragments.
Picosecond Laser Applications
Image showing various applications of the Picosecond Laser, including freckle removal, hair removal, tattoo removal, skin rejuvenation, whitening, and mole washing.

4.6 RF Radio Frequency Anti-Aging

RF radio frequency uses epidermal cooling technology to allow radio wave heat energy to diffuse from the inside out, precisely heating the dermis to 45-60°C. This temperature range is optimal for collagen regeneration, causing instant collagen contraction and stimulating deep collagen regeneration. The device comes with three probes (10mm for eyes, 20mm for face, 30mm for body) for comprehensive anti-aging treatment.

RF Working Principle
Diagram illustrating the working principle of RF radio frequency, showing electric wave heat energy diffusing into the leather layer and stimulating collagen regeneration with different probe sizes.
RF Applications
Image showing the various applications of RF, including skin tightening, pigment removal, anti-hair removal, and anti-puffiness.

4.7 IPL Precise Phototherapy

DPL precise phototherapy combines hair removal and skin care. With the synergy of 480nm, 530nm, and 640nm wavelengths, light energy is absorbed by melanin in hair shafts and converted into heat to destroy follicles for hair removal. Specifically, 640nm focuses on hair removal, 530nm on skin rejuvenation, and 480nm on spot lightening, offering a combined effect of hair removal and skin improvement.

IPL Principle of Hair Removal
Diagram illustrating the IPL principle of hair removal, showing light energy converted to heat in the hair shaft, destroying blood vessels at the dermal papilla and shrinking hair follicles.
IPL Applications
Image showing various applications of IPL, including hair removal, freckle removal, reduction of fine lines, and vascular treatment.

4.8 FAC Lens Technology

The new FAC Lens technology optimizes energy utilization by reducing light energy consumption by 30%, improving light collection by 40%, and achieving a 60% energy increase. Combining laser with FAC can focus light sources with large divergence angles, making energy act more concentratedly on target areas. This enhances the immediacy of results and avoids ineffective energy dispersion, making each operation more precise and efficient.

5. Safety Guidelines

5.1 Eye Protection

  • All personnel in the treatment room, including patients and operators, must wear protective eyewear.
  • Eyes should be optically dense at 5 (OD>5).
  • Patients should close their eyes during treatment, even with glasses.
  • If patients cannot wear eyeglasses, use eye patches to completely block light.
  • For areas very close to the eye (e.g., eyelid), a corneal plate should be used.

5.2 Visual Safety

  • Avoid bright light in the eyes.
  • Never look directly into the laser beam or reflective surface of the handheld, even when wearing eye protection.
  • Set the system to standby mode during pauses in operation to prevent accidental laser firing.
  • Trigger the footswitch and handpiece only when the beam is aimed at the skin treatment area.

5.3 Fire Safety

  • Remove hair from the treatment area.
  • Place only sterilized water-soaked gauze near the treatment area if needed.
  • Ensure fire extinguishers are always available.
  • Avoid flammable paper products or ensure they have evaporated before laser/light exposure.
  • Do not use the system in the presence of flammable materials or anesthetics.
  • Oxygen tubing must be laser-safe.

5.4 Contraindications

Do not use the device if any of the following conditions apply:

  • Cancer, especially skin cancer
  • Pregnancy (including IVF)
  • Use of photosensitizing drugs and herbs
  • Active inflammation or herpes simplex infection in the treatment area
  • History of scarring tumors
  • Diabetes (insulin-dependent)
  • Dry and Sensitive Skin
  • Endocrine disruption (bright light can cause irritation)
  • Use of anticoagulants
  • Epilepsy
  • History of blood coagulation
  • Conditions susceptible to irritation at 808 nanometer wavelengths of sun exposure or artificial tanning 3 to 4 weeks prior to treatment

5.5 Potential Side Effects

While generally safe, some side effects may occur:

  • Discomfort: Patients may experience a sensation similar to a rubber band snap or burning, usually tolerable.
  • Damage to skin texture: Rarely, hard nodules or blisters may appear, requiring wound care.
  • Pigmentation changes: Hyperpigmentation or hypopigmentation can occur, especially in darker skin types or sun-exposed skin. This usually fades within 3-6 months, but can be permanent in rare cases.
  • Scarring: Rare, but can be minimized by following pre- and post-operative guidelines.
  • Excessive edema: Temporary swelling may occur, usually subsiding within a few hours to days.
  • Fragile skin: Skin in the treated area may become fragile; avoid makeup and rubbing.
  • Bruising: A purple bruise may appear, fading over 1-3 months.

6. Treatment Parameters

The 808 Ice Spot Hair Removal System comes with preset parameters based on experienced users, but operators can also customize settings. Parameters include skin color type, laser energy density, and repetition frequency.

Frequency and pulse width are adjusted based on the client's sensitivity and skin color. For lighter skin, use higher frequency and lower pulse width. For darker skin, use lower frequency and higher pulse width.

6.2 Energy Requirement Per Part (Cumulative Energy in J)

Body diagram for energy requirements
Diagram showing different body parts and their corresponding therapeutic areas for energy accumulation.
Body PartTherapeutic Area (Compartments)Cumulative Energy (J)
Upper Arm8-1050,000-8,000
Forearms6-840,000-6,000
Lap11-13650,000-100,000
Calf (of the leg)0-1260,000-9,000
Front part of the chest and abdomen12-1475,000-110,000
Bikini Line16,000-8,000
Armpits16,000-8,000
Backpack12-1475,000-110,000

7. Post-Treatment Care

7.1 Immediate Aftercare

  • Immediately after the procedure, use cold (but not frozen) ice packs or cooled 10x10cm soaked gauze to minimize edema and discomfort.
  • For 4-5 days post-operation, prevent trauma by avoiding hot water baths, exercise, and massages.

7.2 Sun Exposure and Makeup

  • Wear high-index sunscreen (SPF>30) and avoid direct sunlight on the treated area for at least one month. Sun exposure can cause melanin regeneration and pigmentation.
  • Makeup can be worn during the day unless blisters or hard nodules appear. Remove makeup carefully due to skin sensitivity.

7.3 Other Recommendations

  • Apply a topical dressing for 10 days if the treated area comes into contact with dirt.
  • Avoid strenuous exercise or similar activities for a few days until returning to normal.

7.4 Follow-up Visits

Patients can expect to be re-examined and receive additional treatments within 6-8 weeks after surgery, depending on treatment outcome and hair growth cycle.

  • If no further treatment is needed, re-examine after 3-4 months or if hair regrowth occurs.
  • If partial hair removal occurs, re-examine in 6-8 weeks if necessary.
  • If no change is observed, adjust treatment parameters. Multiple treatments with increased intervals allow new hair growth.
  • Patients should protect themselves from the sun throughout the course of treatment.

7.5 End of Treatment

Treatment ends based on professional judgment or patient satisfaction with treatment goals.

8. User Tips

  • For Optimal Results: This machine is highly effective for both hair and tattoo removal, with visible results. Its advanced cooling technology ensures a comfortable, painless experience.
  • Professional Guidance: The seller provides excellent support, including precautions and usage instructions for different probes, especially for personal use.
  • Efficiency: The 10-bar handle configuration offers higher output and more stable energy, leading to faster treatment speeds and better coverage compared to 5-bar handles.
  • Skin Protection: Always ensure proper skin preparation and aftercare, including applying cold gel and moisturizing lotion, to maximize comfort and results.

9. Troubleshooting

Error#SafeguardPossible Causes and Troubleshooting
Tempi errorControl board temperature alarmThere is a 60-degree temperature alarm under the control board heatsink. Causes: 1. The temperature is too high; 2. The control board fan does not work; 3. The temperature sensor is bad or broken wire (note that the control board fan only turns when the light).
Temp2 errorRoom temperature alarmThere is a temperature sensor inserted in the control board, macro channel 35 degrees alarm, no channel 55 degrees alarm. Causes: 1. Room temperature is too high, need to control the room temperature below 28°; 2. The machine is not good heat dissipation, the internal temperature of the machine is too high; 3. Temperature sensor damage (soaked in water is easy to bad). (If the temperature sensor into the water tank, that is the water temperature alarm).
Flow errorWater flow alarmThere is a flow sensor connected to the water circuit. Causes: 1. The water flow is not enough, mainly and the pump pressure is small, the water pipe is too thin, the connector water resistance, the water circuit is not reasonable, etc.; 2. There is a leakage of air in the water circuit; 3. The flow sensor is damaged; 4. Check the wiring.
Level errorTank water level alarmThe water level switch is connected to the middle of the tank. Causes: 1. The water is not added enough; 2. The water level is stuck without floating up; 3. Check whether there is a false welding; 4. Control board problems.
The handle doesn't light upMacro channel Non channel1 (a) handle does not light visual inspection of the laser appearance, there is a buckle broken phenomenon, send back to the original factory maintenance (b) If there are no alarms on the machine interface and the READY changes color normally, either the hitch bar in the handle is loose or the power cord supplying power to the handle is loose. 2. Weak light out of the handle, laser or control board problems.
Blue screenMonitor1. The handle button did not pop up; 2. The terminal wires on the control board are stuck together; 3. If there is a foot pedal, test whether the foot pedal wire connection is twisted together, or directly cut the wire; 4. The foot pedal dripped into the water, wait for the water to dry out.
Black screenMonitor1. The screen into the water; 2. Heavy objects to the screen crushed; 3. Control board problems; 4. Control board and screen wires loose.
TEC does not coolTEC1. TEC refrigerator is bad; 2. Test the relay in the chassis whether all bright, may be one of the relay is bad.

10. Warranty and Support

10.1 Warranty

All machines come with a one-year warranty for the machine host and three months for accessories. This includes lifetime technical support.

10.2 Technical Support

Our professional technical support team is available to assist with after-sales issues. You can contact us via telephone, online chat (WhatsApp, Facebook, Instagram, Skype, email), and more. We are committed to providing the best service possible.

10.3 Training

We provide comprehensive user manuals and instructional videos. Additionally, our 24/7 online consultant service ensures you can resolve any issues quickly. Operating instructions are straightforward, making it accessible to anyone with the provided guidance.

10.4 Certifications

All our machines are CE certified, ensuring quality and safety. They undergo strict quality management to maintain high standards suitable for international operations.

For further details, you can refer to the User Manual (PDF).

11. Frequently Asked Questions (FAQ)

Q1: Is there a warranty for the machine?
--All machines come with a one-year warranty for the machine host and three months for accessories, plus lifetime technical support and online after-sales services.
Q2: Can we customize our logo on the products?
--Certainly. We offer OEM services with a minimum order quantity.
Q3: Are you a manufacturer or a trading company?
--We are the factory and will deliver goods directly from our facilities.
Q4: What are your accepted payment terms?
--We accept Western Union, Money Gram, T/T, and Trade Assurance via AliExpress.
Q5: What transportation modes do you offer?
--We support delivery via DHL, TNT, FedEx, UPS, special lines, sea, and air freight based on customer requirements.
Q6: How are products packaged?
--We offer packaging options including wooden cases, cartons, aluminum cases, and standard export packing.
Q7: Do you provide technical support?
--Our professional technical support team is available to assist with after-sales issues. You can contact us via telephone, online chat (WhatsApp, Facebook, Instagram, Skype, email), and more.
Q8: What is your after-sales service like?
--We have a dedicated technical support team available for timely assistance. Contact us immediately if your machine experiences any issues. We are committed to providing the best service possible.
Q9: What certifications do your machines have?
--All our machines are CE certified, ensuring quality and safety. They undergo strict quality management to maintain high standards suitable for international operations.
Q10: Do you provide training on machine usage?
--Yes, we provide comprehensive user manuals and instructional videos. Additionally, our 24/7 online consultant service ensures you can resolve any issues quickly. Operating instructions are straightforward, making it accessible to anyone with the provided guidance.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.