1. Introduction
The Soprano Titanium Ice 4 IN1 Platinum RF Diode Laser Machine is a versatile beauty device integrating four core functions: hair removal, picosecond laser for tattoo and pigment removal, RF radio frequency for anti-aging and skin tightening, and IPL for hair removal and skin rejuvenation. This advanced system is designed to provide safe, effective, and comfortable treatments for a wide range of aesthetic concerns.
It utilizes selective photothermodynamics for hair removal, targeting hair follicles with precise laser wavelengths (755nm, 808nm, 940nm, 1064nm) while protecting the epidermis with advanced cooling technology. The device features a unique pre-ignition function to ensure stable energy output and extended lifespan of the laser bar. With its multifunctional capabilities and user-friendly interface, it offers a comprehensive solution for professional beauty treatments.


2. Specifications
2.1 Technical Parameters
| Attribute | Value |
|---|---|
| Voltage | 20V-50V |
| Efficacy Principle of Epilator | Laser/IPL/Radio Frequency |
| Number of Lamp Heads | 1 (or 5 or more pieces for some configurations) |
| Power Type | Electric |
| Power Source | Electric |
| Use Areas | BODY, Underarm, Bikini, Whole Face |
| Item Type | Epilator |
| Certification | RoHs, CE, RoHS |
| Product Functions | Hair Removal, Skin Rejuvenation 4 in 1, Anti-Puffiness, Pigment Removal, Skin Tightening, Dark Circles, Face Lift, Pigmentation Correctors |
| Epilator Type | Laser, Diode Laser |
| Screen Size | 15.6-inch color touch 4K display |
| Power | 5000W |
| Skin Color Suitability | Suitable for all skin tones |
| Diode Laser Wavelengths | 808nm/755nm/940nm/1064nm |
| Cooling System | Air Cooling, Water |
| Frequency | 1-10hzs |
| Replacement Heads (Pico Laser) | 1320nm/1064nm/532nm/No scars 532nm/No scars 1064nm |
| Laser Type | Pico Laser |
| Pulse Width | 1-500 ms (adjustable) |
| Filter Alex | Sapphire Filter |
| Shot Count | 60 Million |
2.2 System Principle

3. Setup Instructions
3.1 Adding Water
First, add water to the machine. For the 808nm freezing point hair removal instrument, it is recommended to use steamed water and pure water. Do NOT use tap water or mineral water. Deionized water is preferred if available.
3.2 Connecting Power
Connect the power cord. Ensure you check the input part; the machine is designed for 220V and 110V. Do not connect incorrectly. Once the power supply is connected, rotate the key. The machine will enter the power-on interface after three seconds. Tap and press to proceed.

4. Operating the Device
4.1 User Interface Overview
The device features a 15.6-inch color touch 4K display for easy operation. The main interface allows selection of different treatment modes and adjustment of parameters.

4.2 Mode Selection and Parameter Adjustment
From the main screen, you can select various functions such as Sweep Mode, Point-to-Point, Pico Laser, and RF Radio Frequency. For hair removal, you can choose between SHR (Super Hair Removal) Stack, SHR, and HR (Hair Removal) modes.
The interface allows selection of skin type (I-VI) and body parts (S, M, L, XL) to be treated. Parameters like Fluence (J/cm²), Pulse (ms), Frequency (Hz), and Energy (J) can be adjusted. The system also displays cooling status and treatment count.

4.3 Hair Removal Process
- Application of Cold Gel: Clean the treatment area and apply a cold gel containing hair inhibiting ingredients.
- Irradiation: Customers should wear goggles. Complete the hair removal session with 3 minutes of painless irradiation.
- Cool Off: Wipe off the cold gel and use a cooling pack to apply cold to the skin. Apply a calming, moisturizing lotion after treatment.
The hair removal operation is performed by pressing the handle button or foot pedal to emit light. To pause, press the button to stop working and enter standby mode.
4.4 808 Diode Laser Hair Removal - Pre-Ignition Function
The device incorporates a pre-ignition function. Before delivering high-energy output, it performs a low-power pre-activation to stabilize the laser system. This improves laser output stability, protects the laser bar, enhances continuous emission performance, and reduces failure rates, ensuring a more stable and effective treatment.

4.5 Picosecond Laser Operation
The picosecond laser utilizes a light blasting effect where high-intensity laser penetrates the epidermis to reach pigment clusters in the dermis. The short-duration, high-energy pulses cause pigment clusters to expand and explode instantly, which are then metabolized naturally by the body. This function is effective for removing freckles, washing eyebrows, tattoo removal, and fading acne scars and birthmarks without scarring.


4.6 RF Radio Frequency Anti-Aging
RF radio frequency uses epidermal cooling technology to allow radio wave heat energy to diffuse from the inside out, precisely heating the dermis to 45-60°C. This temperature range is optimal for collagen regeneration, causing instant collagen contraction and stimulating deep collagen regeneration. The device comes with three probes (10mm for eyes, 20mm for face, 30mm for body) for comprehensive anti-aging treatment.


4.7 IPL Precise Phototherapy
DPL precise phototherapy combines hair removal and skin care. With the synergy of 480nm, 530nm, and 640nm wavelengths, light energy is absorbed by melanin in hair shafts and converted into heat to destroy follicles for hair removal. Specifically, 640nm focuses on hair removal, 530nm on skin rejuvenation, and 480nm on spot lightening, offering a combined effect of hair removal and skin improvement.


4.8 FAC Lens Technology
The new FAC Lens technology optimizes energy utilization by reducing light energy consumption by 30%, improving light collection by 40%, and achieving a 60% energy increase. Combining laser with FAC can focus light sources with large divergence angles, making energy act more concentratedly on target areas. This enhances the immediacy of results and avoids ineffective energy dispersion, making each operation more precise and efficient.
5. Safety Guidelines
5.1 Eye Protection
- All personnel in the treatment room, including patients and operators, must wear protective eyewear.
- Eyes should be optically dense at 5 (OD>5).
- Patients should close their eyes during treatment, even with glasses.
- If patients cannot wear eyeglasses, use eye patches to completely block light.
- For areas very close to the eye (e.g., eyelid), a corneal plate should be used.
5.2 Visual Safety
- Avoid bright light in the eyes.
- Never look directly into the laser beam or reflective surface of the handheld, even when wearing eye protection.
- Set the system to standby mode during pauses in operation to prevent accidental laser firing.
- Trigger the footswitch and handpiece only when the beam is aimed at the skin treatment area.
5.3 Fire Safety
- Remove hair from the treatment area.
- Place only sterilized water-soaked gauze near the treatment area if needed.
- Ensure fire extinguishers are always available.
- Avoid flammable paper products or ensure they have evaporated before laser/light exposure.
- Do not use the system in the presence of flammable materials or anesthetics.
- Oxygen tubing must be laser-safe.
5.4 Contraindications
Do not use the device if any of the following conditions apply:
- Cancer, especially skin cancer
- Pregnancy (including IVF)
- Use of photosensitizing drugs and herbs
- Active inflammation or herpes simplex infection in the treatment area
- History of scarring tumors
- Diabetes (insulin-dependent)
- Dry and Sensitive Skin
- Endocrine disruption (bright light can cause irritation)
- Use of anticoagulants
- Epilepsy
- History of blood coagulation
- Conditions susceptible to irritation at 808 nanometer wavelengths of sun exposure or artificial tanning 3 to 4 weeks prior to treatment
5.5 Potential Side Effects
While generally safe, some side effects may occur:
- Discomfort: Patients may experience a sensation similar to a rubber band snap or burning, usually tolerable.
- Damage to skin texture: Rarely, hard nodules or blisters may appear, requiring wound care.
- Pigmentation changes: Hyperpigmentation or hypopigmentation can occur, especially in darker skin types or sun-exposed skin. This usually fades within 3-6 months, but can be permanent in rare cases.
- Scarring: Rare, but can be minimized by following pre- and post-operative guidelines.
- Excessive edema: Temporary swelling may occur, usually subsiding within a few hours to days.
- Fragile skin: Skin in the treated area may become fragile; avoid makeup and rubbing.
- Bruising: A purple bruise may appear, fading over 1-3 months.
6. Treatment Parameters
The 808 Ice Spot Hair Removal System comes with preset parameters based on experienced users, but operators can also customize settings. Parameters include skin color type, laser energy density, and repetition frequency.
6.1 Recommended Parameters (Spot Area 15mm*15mm)
Frequency and pulse width are adjusted based on the client's sensitivity and skin color. For lighter skin, use higher frequency and lower pulse width. For darker skin, use lower frequency and higher pulse width.
6.2 Energy Requirement Per Part (Cumulative Energy in J)

| Body Part | Therapeutic Area (Compartments) | Cumulative Energy (J) |
|---|---|---|
| Upper Arm | 8-10 | 50,000-8,000 |
| Forearms | 6-8 | 40,000-6,000 |
| Lap | 11-13 | 650,000-100,000 |
| Calf (of the leg) | 0-12 | 60,000-9,000 |
| Front part of the chest and abdomen | 12-14 | 75,000-110,000 |
| Bikini Line | 1 | 6,000-8,000 |
| Armpits | 1 | 6,000-8,000 |
| Backpack | 12-14 | 75,000-110,000 |
7. Post-Treatment Care
7.1 Immediate Aftercare
- Immediately after the procedure, use cold (but not frozen) ice packs or cooled 10x10cm soaked gauze to minimize edema and discomfort.
- For 4-5 days post-operation, prevent trauma by avoiding hot water baths, exercise, and massages.
7.2 Sun Exposure and Makeup
- Wear high-index sunscreen (SPF>30) and avoid direct sunlight on the treated area for at least one month. Sun exposure can cause melanin regeneration and pigmentation.
- Makeup can be worn during the day unless blisters or hard nodules appear. Remove makeup carefully due to skin sensitivity.
7.3 Other Recommendations
- Apply a topical dressing for 10 days if the treated area comes into contact with dirt.
- Avoid strenuous exercise or similar activities for a few days until returning to normal.
7.4 Follow-up Visits
Patients can expect to be re-examined and receive additional treatments within 6-8 weeks after surgery, depending on treatment outcome and hair growth cycle.
- If no further treatment is needed, re-examine after 3-4 months or if hair regrowth occurs.
- If partial hair removal occurs, re-examine in 6-8 weeks if necessary.
- If no change is observed, adjust treatment parameters. Multiple treatments with increased intervals allow new hair growth.
- Patients should protect themselves from the sun throughout the course of treatment.
7.5 End of Treatment
Treatment ends based on professional judgment or patient satisfaction with treatment goals.
8. User Tips
- For Optimal Results: This machine is highly effective for both hair and tattoo removal, with visible results. Its advanced cooling technology ensures a comfortable, painless experience.
- Professional Guidance: The seller provides excellent support, including precautions and usage instructions for different probes, especially for personal use.
- Efficiency: The 10-bar handle configuration offers higher output and more stable energy, leading to faster treatment speeds and better coverage compared to 5-bar handles.
- Skin Protection: Always ensure proper skin preparation and aftercare, including applying cold gel and moisturizing lotion, to maximize comfort and results.
9. Troubleshooting
| Error# | Safeguard | Possible Causes and Troubleshooting |
|---|---|---|
| Tempi error | Control board temperature alarm | There is a 60-degree temperature alarm under the control board heatsink. Causes: 1. The temperature is too high; 2. The control board fan does not work; 3. The temperature sensor is bad or broken wire (note that the control board fan only turns when the light). |
| Temp2 error | Room temperature alarm | There is a temperature sensor inserted in the control board, macro channel 35 degrees alarm, no channel 55 degrees alarm. Causes: 1. Room temperature is too high, need to control the room temperature below 28°; 2. The machine is not good heat dissipation, the internal temperature of the machine is too high; 3. Temperature sensor damage (soaked in water is easy to bad). (If the temperature sensor into the water tank, that is the water temperature alarm). |
| Flow error | Water flow alarm | There is a flow sensor connected to the water circuit. Causes: 1. The water flow is not enough, mainly and the pump pressure is small, the water pipe is too thin, the connector water resistance, the water circuit is not reasonable, etc.; 2. There is a leakage of air in the water circuit; 3. The flow sensor is damaged; 4. Check the wiring. |
| Level error | Tank water level alarm | The water level switch is connected to the middle of the tank. Causes: 1. The water is not added enough; 2. The water level is stuck without floating up; 3. Check whether there is a false welding; 4. Control board problems. |
| The handle doesn't light up | Macro channel Non channel | 1 (a) handle does not light visual inspection of the laser appearance, there is a buckle broken phenomenon, send back to the original factory maintenance (b) If there are no alarms on the machine interface and the READY changes color normally, either the hitch bar in the handle is loose or the power cord supplying power to the handle is loose. 2. Weak light out of the handle, laser or control board problems. |
| Blue screen | Monitor | 1. The handle button did not pop up; 2. The terminal wires on the control board are stuck together; 3. If there is a foot pedal, test whether the foot pedal wire connection is twisted together, or directly cut the wire; 4. The foot pedal dripped into the water, wait for the water to dry out. |
| Black screen | Monitor | 1. The screen into the water; 2. Heavy objects to the screen crushed; 3. Control board problems; 4. Control board and screen wires loose. |
| TEC does not cool | TEC | 1. TEC refrigerator is bad; 2. Test the relay in the chassis whether all bright, may be one of the relay is bad. |
10. Warranty and Support
10.1 Warranty
All machines come with a one-year warranty for the machine host and three months for accessories. This includes lifetime technical support.
10.2 Technical Support
Our professional technical support team is available to assist with after-sales issues. You can contact us via telephone, online chat (WhatsApp, Facebook, Instagram, Skype, email), and more. We are committed to providing the best service possible.
10.3 Training
We provide comprehensive user manuals and instructional videos. Additionally, our 24/7 online consultant service ensures you can resolve any issues quickly. Operating instructions are straightforward, making it accessible to anyone with the provided guidance.
10.4 Certifications
All our machines are CE certified, ensuring quality and safety. They undergo strict quality management to maintain high standards suitable for international operations.
For further details, you can refer to the User Manual (PDF).
11. Frequently Asked Questions (FAQ)
- Q1: Is there a warranty for the machine?
- --All machines come with a one-year warranty for the machine host and three months for accessories, plus lifetime technical support and online after-sales services.
- Q2: Can we customize our logo on the products?
- --Certainly. We offer OEM services with a minimum order quantity.
- Q3: Are you a manufacturer or a trading company?
- --We are the factory and will deliver goods directly from our facilities.
- Q4: What are your accepted payment terms?
- --We accept Western Union, Money Gram, T/T, and Trade Assurance via AliExpress.
- Q5: What transportation modes do you offer?
- --We support delivery via DHL, TNT, FedEx, UPS, special lines, sea, and air freight based on customer requirements.
- Q6: How are products packaged?
- --We offer packaging options including wooden cases, cartons, aluminum cases, and standard export packing.
- Q7: Do you provide technical support?
- --Our professional technical support team is available to assist with after-sales issues. You can contact us via telephone, online chat (WhatsApp, Facebook, Instagram, Skype, email), and more.
- Q8: What is your after-sales service like?
- --We have a dedicated technical support team available for timely assistance. Contact us immediately if your machine experiences any issues. We are committed to providing the best service possible.
- Q9: What certifications do your machines have?
- --All our machines are CE certified, ensuring quality and safety. They undergo strict quality management to maintain high standards suitable for international operations.
- Q10: Do you provide training on machine usage?
- --Yes, we provide comprehensive user manuals and instructional videos. Additionally, our 24/7 online consultant service ensures you can resolve any issues quickly. Operating instructions are straightforward, making it accessible to anyone with the provided guidance.