The Veinasa VWS007L Micro Weather Station is an advanced, integrated multifunctional intelligent weather sensor designed for comprehensive environmental monitoring. It is capable of accurately measuring ambient temperature, relative humidity, atmospheric pressure, wind direction, wind speed, rainfall, and solar radiation (pyranometer).

This robust device is suitable for a wide range of applications, including:

  • Wind turbine and solar power station monitoring
  • Transmission lines and substations
  • Unmanned aerial vehicles (UAVs) and vehicle-shipborne weather stations
  • Grid smart cities and water conservancy projects
  • Environmental protection, agriculture, forestry, and tourism
  • Meteorological observation stations
  • Intelligent building and building automation systems
  • Meteorological, airport, and traffic control

Its advanced technology ensures accurate measurements even in challenging conditions, meeting the standards of the World Meteorological Organization and domestic/international regulations. The VWS007L features a working voltage of DC9~30V and digital RS485 output for easy integration.

Veinasa VWS007L Micro Weather Station front view
Figure 1: Front view of the Veinasa VWS007L Micro Weather Station, showing its multi-sensor design and key specifications.
Veinasa VWS007L Micro Weather Station angled view
Figure 2: Angled view of the Veinasa VWS007L, highlighting the pyranometer and stacked sensor housing.

2. Safety Information

  • Electrical Safety: Ensure the power supply (DC9~30V) matches the device requirements. Incorrect voltage can damage the unit. All wiring should be performed by qualified personnel following local electrical codes.
  • Mounting: Mount the weather station securely to prevent it from falling, especially in high wind conditions. Choose a location free from obstructions that could interfere with wind, rain, or solar radiation measurements.
  • Environmental Conditions: While the device is rated IP66 for dust and water resistance, avoid direct exposure to corrosive substances or extreme physical impact.
  • Maintenance: Disconnect power before performing any maintenance or cleaning.

3. Product Overview

The Veinasa VWS007L integrates multiple sensors into a single compact unit. Key components include:

  • Pyranometer: Located at the top for solar radiation measurement.
  • Wind Speed & Direction Sensors: Utilize ultrasonic measurement principles, typically located within the upper housing.
  • Temperature & Humidity Sensors: Integrated within the shielded housing to protect from direct sunlight and precipitation.
  • Barometric Pressure Sensor: Measures atmospheric pressure.
  • Rainfall Sensor: Employs Doppler radar technology for accurate precipitation measurement.
  • Electronic Compass: For accurate orientation.
  • Main Control Unit: High-performance ARM processor + FPGA integrated architecture for data processing and communication.
Product Features of Veinasa VWS007L
Figure 3: Key product features, including advanced wind speed technology and CE certification.
Internal view of wind speed, direction, and pressure sensors
Figure 4: Internal view showing the circuit board and components for wind speed, direction, and pressure sensors.
Rainfall sensor and application examples
Figure 5: Illustration of the Doppler radar rainfall sensor and its application in a photovoltaic power station and substation.

4. Setup

4.1 Mounting

  1. Choose a Location: Select an outdoor location that provides unobstructed exposure to wind, rain, and sunlight. Avoid mounting near large buildings, trees, or other structures that could create turbulence or block sensors.
  2. Secure Mounting: Use appropriate mounting hardware (not included) to securely attach the weather station to a pole or mast. Ensure the mounting is stable and can withstand local weather conditions, including strong winds.
  3. Orientation: The integrated electronic compass assists with orientation. Ensure the device is mounted as vertically as possible.

4.2 Wiring

The VWS007L uses an RS485 digital output for communication and requires a DC9~30V power supply.

  1. Power Connection: Connect the DC9~30V power supply to the designated power input terminals. Observe correct polarity.
  2. RS485 Communication: Connect the RS485 A and B data lines to your data acquisition system or controller.
  3. Grounding: Ensure proper grounding to protect against electrical surges.
Close-up of the weather station base and connector
Figure 6: Close-up view of the weather station's base, showing the connector for power and data.

4.3 Initial Power-Up

Once mounted and wired, apply power to the device. The weather station will begin collecting data immediately. Refer to your data acquisition system's manual for instructions on how to read and interpret the RS485 output.

5. Operating Instructions

The Veinasa VWS007L operates continuously once powered, collecting data from its various sensors. Data is transmitted via the RS485 interface.

  • Data Acquisition: Connect the RS485 output to a compatible data logger, PLC, or computer system. The communication protocol and data format will be detailed in the technical specifications provided with the product.
  • Sensor Operation:
    • Wind Speed & Direction: Ultrasonic sensors provide real-time wind data without moving parts, ensuring durability.
    • Rainfall: The Doppler radar technology accurately detects and measures liquid precipitation.
    • Ice Melting Function: The device includes an anti-freezing function. When ambient temperature drops to -10℃ and water temperature is between 0℃~3℃ with a precipitation rate of 25mm/h, the ice melting function activates to prevent sensor freezing. The output signal remains normal during this operation.

6. Maintenance

  • Regular Cleaning: Periodically inspect and clean the sensor surfaces, especially the pyranometer dome and the rainfall sensor area, to remove dust, dirt, bird droppings, or other debris that could affect measurement accuracy. Use a soft cloth and mild cleaning solution if necessary.
  • Physical Inspection: Check for any physical damage to the housing, mounting hardware, or cables. Ensure all connections are secure.
  • Software/Firmware Updates: Consult the manufacturer's website or support for any available firmware updates that may improve performance or add features.
  • Calibration: The sensors are factory-calibrated. If you suspect a calibration issue, contact technical support for guidance.

7. Troubleshooting

  • No Data Output:
    • Check power supply: Ensure the device is receiving stable DC9~30V power.
    • Verify wiring: Confirm RS485 A and B lines are correctly connected and not swapped.
    • Check communication settings: Ensure your data acquisition system's RS485 settings (baud rate, parity, stop bits) match the weather station's configuration.
  • Inaccurate Readings:
    • Wind: Check for obstructions near the sensor that could block airflow.
    • Rainfall: Ensure the rainfall sensor area is clean and free of debris.
    • Solar Radiation: Clean the pyranometer dome.
    • Temperature/Humidity: Ensure the sensor housing is not directly exposed to external heat sources or excessive moisture buildup.
  • Device Not Responding:
    • Perform a power cycle: Disconnect power for a few seconds, then reconnect.
    • Inspect for physical damage: Check for any visible damage to the unit or cables.

8. Specifications

Parameter Specification
ModelVWS007L
Size (L*W*H)168.31mm * 119.8mm * 283.9mm
Weight1.4 kg
IP ClassIP66
Body MaterialAnodized aluminium alloy or engineering plastics
Operating Temperature-40 ~ 85℃
Working VoltageDC9 ~ 30V
Working Current (DC12V)0.043A
Power (DC24V)120W
Air Temperature Sensor
Range-40 to 105℃
Resolution0.01℃
Accuracy±0.2℃ @20-50℃
Response Time2s (customizable)
Relative Humidity Sensor
Range0-100%
Accuracy±3%RH@≤80%RH, ±5%RH@>80%RH
Resolution0.01%
Response Time4s (customizable)
Wind Speed Sensor
Range0 ~ 65m/s
Resolution0.1m/s
Accuracy±0.2m/s @0-10m/s, ±2% @>10m/s
TypeUltrasonic measurement principle
Wind Direction Sensor
Sensor Range0 ~ 360°
Accuracy±1°
Resolution1°
TypeUltrasonic measurement principle
Barometric Pressure Sensor
Range450 ~ 1100 hPa (Extended: 10-1200hPa)
Accuracy±1hPa, ±0.5hPa
Resolution0.012hPa
Long Term Stability±1 (hpar/yr)
Rainfall
Liquid Precipitation Resolution0.1 / 0.2 / 0.5 / 1.0 mm
Droplet Diameter0.3-5.0 mm
TypeDoppler radar measurement principle
Rain Intensity
Range0.1 ~ 200mm/h
Falling Speed of Particulate Matter1.5 ~ 10m/s
Accuracy±10% (typical value of simulating 0.5mm diameter raindrop)
Solar Radiation (Pyranometer)
Spectrum Range305 ~ 2800nm (50%)
Sensitivity≥10μV/(W/m²)
Response Time5S
Range0 ~ 2000W/m²
Resolution1W/m²; 0.1MJ/M²
Nonlinear+/-2%
Unstability<+/- 1.5% Change every year
Output ContentInstantaneous value (W/m²), Cumulative value of minutes (MJ/M²), Daily cumulative value (MJ/M²)
Adjustable Angle0-90°
TypeThermoelectric measurement principle
PM1.0
Range0.3 ~ 1.0 μm
Resolution1 μg/m³
PM2.5
Range1.0 ~ 2.5 μm
Resolution1 μg/m³
PM10
Range2.5 ~ 10 μm
Resolution1 μg/m³
Noise
Range30 ~ 120dB
Resolution0.1dB
Analog Input Options
Temperature (PT100)18-330Ω
Digital InputRS485
Ice Melting and Freezing Rain Function
Ice Melting Activation ConditionsAmbient Temp: -10℃, Water Temp: 0℃~3℃, Precipitation Rate: 25mm/h
Ice Thickness Measurement13mm or 37mm (Sensors measure surface of air components)
Ice Melting Time15min or 35min (-10℃)
Output Signal (during activation)Normal
Electronic Compass
Precision1° (RMS)
Resolution0.1°
CalibrationHard/soft Magnetism Calibration, Magnetic declination Calibration
Compliance
EMCIEC61000-4-2, 3, 4, 5, 6, 8, 9, 10, 11 Class A level
Environmental CertificationGB/T2423.1, 2, 4, 7, 17, 22 Severity level 2 and 3
Selection Guide for Veinasa Micro Weather Stations
Figure 7: Selection guide table showing meteorological elements available for different Veinasa models (VWS002L, VWS005L, VWS006L, VWS007L).

9. User Tips

  • Optimal Placement: For the most accurate readings, ensure the weather station is mounted away from heat sources, reflective surfaces, and any structures that could create wind shadows or block sunlight.
  • Data Logging: Regularly back up your collected data to prevent loss. Consider using a robust data logger with sufficient storage capacity for long-term monitoring.
  • Power Stability: Use a stable power source within the specified voltage range (DC9~30V) to ensure consistent operation and prevent data corruption.

10. Warranty and Support

Veinasa products are designed for reliability and performance. For technical support, warranty claims, or service inquiries, please contact the manufacturer or your authorized distributor. When contacting support, please have your product model (VWS007L) and any relevant purchase information ready.

Support is available in English and Chinese.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.