Veinasa XS-JQZ

Contents

Veinasa XS-JQZ Outdoor Pole Meteorological Station

Professional Automatic Wind Speed Rainfall Temperature Humidity Sensors

Model: XS-JQZ

1. Product Overview

The Veinasa XS-JQZ is an advanced outdoor pole meteorological station designed for professional environmental monitoring. It integrates multiple high-precision sensors to automatically measure and display various weather parameters, including wind speed, rainfall, temperature, and humidity. Featuring an LED large screen display and IoT Lora capabilities, it provides real-time data monitoring and is suitable for a wide range of applications.

Veinasa XS-JQZ Outdoor Pole Meteorological Station with LED display in an outdoor setting.
Figure 1: Veinasa XS-JQZ Meteorological Station in an outdoor environment.

Key Features:

  • Multi-sensor integration for comprehensive environmental data.
  • High-precision probes for accurate measurements.
  • Built-in LED screen for real-time data display.
  • High protection level, suitable for harsh outdoor environments.
  • IoT Lora technology for remote data transmission.
  • Solar power capability for autonomous operation.

2. Installation and Setup

2.1 Components Overview

Diagram illustrating various high-precision sensors including wind speed, wind direction, louver box, soil temperature and humidity, rainfall, total solar radiation, rain and snow, noise, and photosynthetically active radiation.
Figure 2: High-precision sensors integrated into the station.

2.2 Mounting Instructions

  1. Pole Assembly: The station is designed for mounting on a 2.5m pole. Ensure the pole is securely anchored to the ground.
  2. Sensor Attachment: Attach the various sensors (wind speed, wind direction, louver box, etc.) to the designated points on the mounting body. Refer to the specific sensor diagrams for correct orientation.
  3. LED Screen Installation: Mount the LED screen (192x96cm) using the provided cross arm and windproof zipper.
  4. Wiring: Connect the sensors and LED screen to the main control unit. The system uses RS485 communication. Standard cable length is 1.5 meters; for extended lengths, additional cable can be added (5 yuan per meter).
  5. Power Connection: Connect the station to a 220V AC power source using the provided 220V to 12V power adapter.
Assembled meteorological station with LED display showing real-time data.
Figure 3: Assembled station ready for operation.

3. Operating Instructions

3.1 Real-time Data Display

The integrated LED display provides real-time environmental monitoring data. The display is high-brightness and waterproof, ensuring visibility and durability in outdoor conditions.

LED display showing environmental monitoring data including wind speed, temperature, humidity, pressure, PM2.5, PM10, noise, rainfall, negative ions, and total radiation.
Figure 4: Real-time data on the LED display.

3.2 Environmental Monitoring Cloud Platform

The station connects to a free environmental monitoring cloud platform, allowing you to monitor data anytime, anywhere. Key functionalities include:

  • Real-time monitoring: View live data streams from all connected sensors.
  • Curve Viewing: Analyze historical data trends through graphical representations.
  • Over-limit alarm: Receive alerts when parameters exceed predefined thresholds.
  • Data Export: Export collected data for further analysis (e.g., to Excel spreadsheets).
Screenshot of the Free Environmental Monitoring Cloud Platform interface on desktop and mobile, showing various monitoring features.
Figure 5: Environmental Monitoring Cloud Platform interface.

3.3 Data Collection and Software

The data collection unit supports 11-16 channels and features a Chinese LCD screen with backlight. It can store data internally or via a communication module/battery storage. Historical data can be viewed directly on the screen or exported to an Excel spreadsheet using the standalone software.

4. Maintenance

To ensure optimal performance and longevity of your Veinasa XS-JQZ Meteorological Station, regular maintenance is recommended:

  • Sensor Cleaning: Periodically inspect and clean all sensors, especially the rainfall collector, wind speed/direction sensors, and louver box, to remove dust, debris, or insect nests that may affect accuracy.
  • Pole Stability: Check the mounting pole for stability and ensure all fasteners are tight.
  • Cable Inspection: Examine all cables for signs of wear, damage, or loose connections.
  • Power Supply: Verify the power adapter and connections are secure and free from corrosion.
  • Software Updates: Check for any available software or firmware updates for the data collection unit and cloud platform to ensure compatibility and access to new features.
High-end waterproof LED display for real-time data, shown in a rainy outdoor environment.
Figure 6: The station's waterproof design ensures durability in various weather conditions.

5. Troubleshooting

If you encounter issues with your meteorological station, consider the following common troubleshooting steps:

  • No Power/Display Off:
    • Check the 220V AC power connection and ensure the power adapter is functioning.
    • Verify all power cables are securely connected.
  • Inaccurate Readings:
    • Ensure sensors are clean and free from obstructions (e.g., leaves, dirt, spiderwebs).
    • Check sensor connections for looseness or damage.
    • Confirm the station is mounted correctly and not influenced by nearby structures or heat sources.
  • No Data on Cloud Platform:
    • Verify the station has a stable internet connection (if applicable for Lora gateway).
    • Check the communication cables (RS485) between the sensors and the data collector.
    • Ensure the cloud platform account is correctly configured and linked to your device.
  • LED Display Issues:
    • If the display is dim or flickering, check the power supply.
    • If segments are missing, there might be a connection issue to the LED module.

If problems persist after attempting these steps, please contact customer support for further assistance.

6. Specifications

General Specifications:

  • Brand Name: Veinasa
  • Model Number: XS-JQZ
  • Place of Origin: China
  • Mounting Type: Mounting body
  • Pole Height: 2.5m
  • Communication: RS485 wind communication
  • LED Screen: 192x96cm, includes cross arm and windproof zipper.
  • Power Supply: 220V AC, with 220V to 12V Power Adapter
  • Manufacturing Date Code: 2025

Technical Parameters:

Category Sub-unit Technical Parameters
100 Leaf Box Many Fax Feel Device Louvered Box Integrated Mainboard For integrating multi-in-one sensors
Atmospheric temperature and humidity sensor Temperature: Measurement range: -40 - 80 °C; Resolution: 0.1 °C; Accuracy: ±0.3 °C
Humidity: Measurement range: 0-100%RH; Resolution: 0.1; Accuracy: ±1.5%
Atmospheric pressure sensor Measurement Range: 300 - 1100 hPa; Resolution: 0.1 hPa; Accuracy: ±1 hPa
Light intensity sensor (Outdoor Type) Measurement Range: 0-200000LUX; Wavelength Range: 380nm-780nm;
Maximum allowable error: ±1%; Fs: Temperature characteristic: ±0.5%/°C; Accuracy: ±4%
Noise sensor (Louvered Box Type) Measurement Range: 30-130dB; Resolution: 0.1dB
Measurement error: ±3dB (calibrated under 94dB (31.5Hz-8kHz) condition)
PM2.5/PM10 particulate matter monitoring sensor Measurement range: 0-500ug/m3; Resolution: 1ug/m3;
Precision: ≤100ug/m3: ±10ug/m3; >100ug/m3: 10% reading (calibrated with TS-030, 25 ±2 °C, 50 ±10%RH)
Wind Speed Sensor Measurement range: 0-70m/s; Resolution: 0.1m/s
Accuracy: ±(0.3 ±0.03V)/m/s
Wind direction sensor Measurement range: 0-360°; Resolution: 1°; Accuracy: ±3°
Rainfall Sensor Measurement range: 0-4mm/min; Resolution: 0.2mm; Accuracy: ±4%
(Indoor static test, rainfall intensity 2mm/min)
Negative ion sensor Measurement range: 0-50000 ions/cm³; Accuracy: ±10%; Resolution: 10 ions
Data collection instrument 11-16 Channels Up to 16 sensor channels. Chinese LCD screen with backlight for data logger, communication module, or battery storage.
Software Standalone Software View and store historical data, export to Excel spreadsheet.
Table of Product Parameters detailing technical specifications for various sub-units and components.
Figure 7: Detailed Product Parameters.

7. User Tips

  • Optimal Placement: For the most accurate wind readings, ensure the station is mounted in an open area, away from tall buildings, trees, or other obstructions that could interfere with airflow.
  • Regular Data Review: Utilize the cloud platform's curve viewing and data export features to regularly analyze environmental trends and identify any anomalies.
  • Alarm Configuration: Configure over-limit alarms on the cloud platform for critical parameters to receive timely notifications about significant environmental changes.
  • Customization: For specific customization needs or additional sensor integrations, contact Veinasa customer service directly.

8. Warranty and Support

Veinasa is committed to providing professional after-sales service. If you encounter any issues with your product, please contact our customer service team. We aim to respond within 1-10 hours.

Contacting Support:

If you have any questions or are not completely satisfied with your package, please do not hesitate to contact us before leaving feedback. We are dedicated to solving any problems to your satisfaction.

After-sales Service information, including contact details and feedback encouragement.
Figure 8: After-sales Service commitment.

© 2025 Veinasa. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.