1. Introduction
1.1 Purpose
This manual describes the assembly, installation, operation, and troubleshooting of this unit. Please read this manual carefully before installations and operations. Keep manual for future reference.
1.2 Scope
This manual provides safety and installation guidelines as well as information on tools and wiring.
2. Safety Instructions
WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.
- Before using the unit, read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual.
- CAUTION: To reduce risk of injury, charge only deep-cycle lead acid type rechargeable batteries. Other types of batteries may burst, causing personal injury and damage.
- Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
- To reduce risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
- CAUTION: Only qualified personnel can install this device with battery.
- NEVER charge a frozen battery.
- For optimum operation of this inverter/charger, please follow required specs to select appropriate cable size. It's very important to correctly operate this inverter/charger.
- Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts and could cause an explosion.
- Please strictly follow installation procedure when you want to disconnect AC or DC terminals. Please refer to the INSTALLATION section of this manual for the details.
- One piece of 150A fuse is provided as over-current protection for the battery supply.
- GROUNDING INSTRUCTIONS: This inverter/charger should be connected to a permanent grounded wiring system. Be sure to comply with local requirements and regulations to install this inverter.
- NEVER cause AC output and DC input short circuited. Do NOT connect to the mains when DC input short circuits.
- Warning!! Only qualified service persons are able to service this device. If errors still persist after following troubleshooting table, please send this inverter/charger back to local dealer or service center for maintenance.
3. Setup
3.1 Unpacking and Inspection
Before installation, please inspect the unit. Be sure that nothing inside the package is damaged. You should have received the following items inside the package:
- The unit x 1
- User manual x 1
Video: Product Unboxing and Initial Overview
This video demonstrates the unboxing of the DATOUBOSS inverter, showing the packaging, included user manual, and the inverter itself from various angles, highlighting the display, control buttons, and connection ports.
3.2 Preparation
Before connecting anything, please remove the bottom cover by unscrewing two screws.
3.3 Mounting the Unit
Consider the following points before selecting where to install:
- Do not mount the inverter on flammable construction materials.
- Mount on a solid surface.
- Install this inverter at eye level in order to allow the LCD display to be read at all times.
- For proper air circulation to dissipate heat, allow a clearance of approximately 20 cm to the side and approximately 50 cm above and below the unit.
- The ambient temperature should be between -10°C and 50°C to ensure optimal operation.
- The recommended installation position is to be adhered to the wall vertically.
- Be sure to keep other objects and surfaces as shown in the diagram to guarantee sufficient heat dissipation and to have enough space for removing wires.
SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.
Install the unit by screwing two screws. Use M6*80mm expansion bolts.

Diagram illustrating the recommended clearances and mounting points for the inverter.
3.4 Battery Connection
CAUTION: For safety operation and regulation compliance, it's requested to install a separate DC over-current protector or disconnect device between battery and inverter. It may not be requested to have a disconnect device in some applications, however, it's still requested to have over-current protection installed. Please refer to typical amperage in the table below as required fuse or breaker size.
WARNING! All wiring must be performed by qualified personnel.
WARNING! It's very important for system safety and efficient operation to use appropriate cable for battery connection. To reduce risk of injury, please use the proper recommended cable and terminal size as below.
Recommended Battery Cable and Terminal Size:
| Model | Typical Amperage | Battery capacity | Ring Terminal | Torque value | |
|---|---|---|---|---|---|
| Wire Size Cable(mm²) | Dimensions D(mm) L(mm) | ||||
| 1KVA/2KVA | 44A/88A | 100AH | 1*6AWG 14 | 6.4 33.2 | 2~3 Nm |
| 2*10AWG 6 | 6.4 23.8 | ||||
| 3KVA | 132A | 100AH | 1*4AWG 22 | 6.4 33.2 | 2~3 Nm |
| 200AH | 2*8AWG 9 | 6.4 29.2 | |||
| 5KVA | 109A | 200AH | 1*2AWG 38 | 6.4 39.2 | 2~3 Nm |
| 2*6AWG 28 | 6.4 33.2 | ||||
Please follow below steps to implement battery connection:
- Assemble battery ring terminal based on recommended battery cable and terminal size.
- Insert the battery wires flatly into battery connectors of inverter and make sure the bolts are tightened with torque of 2 Nm in clockwise direction. Make sure polarity at both the battery and the inverter/charger is correctly connected and conductors are tightly screwed into the battery terminals. Recommended tool: #2 Pozi Screwdriver.

Rear view of the inverter showing the DC input terminals for battery connection.
3.5 AC Input/Output Connection
CAUTION: Before connecting to AC input power source, please install a separate AC breaker between inverter and AC input power source. This will ensure the Inverter can be disconnected during maintenance and fully protected from over current of AC input. The recommended spec of breaker is 32A for 3KW and 50A for 5KW.
CAUTION: There are two terminal blocks with "IN" and "OUT" markings. Please do NOT mis-connect input and output connectors.
WARNING! All wiring must be performed by qualified personnel.
WARNING! It's very important for system safety and efficient operation to use appropriate cable for AC input connection. To reduce risk of injury, please use the proper recommended cable size as below.
Suggested Cable Requirement for AC Wires:
| Model | Gauge | Torque value |
|---|---|---|
| 1KVA | 16AWG | 0.5~0.6Nm |
| 2KVA | 14AWG | 0.8~1.0Nm |
| 3KVA | 12AWG | 1.2~1.6Nm |
| 5KVA | 8AWG | 1.4~1.6Nm |
Please follow below steps to implement AC input/output connection:
- Before making AC input/output connection, be sure to open DC protector or disconnector first.
- Remove insulation sleeve 10mm for six conductors. And shorten phase L and neutral conductor N 3 mm.
- Insert AC input wires according to polarities indicated on terminal block and tighten the terminal screws. Be sure to connect PE protective conductor (ground) first.

Rear view of the inverter showing AC input and output terminals.
3.6 PV Connection (Only applies for models with solar charger)
CAUTION: Before connecting to PV modules, please install separately a DC circuit breaker between inverter and PV modules.
WARNING! All wiring must be performed by qualified personnel.
WARNING! It's very important for system safety and efficient operation to use appropriate cable for PV module connection. To reduce risk of injury, please use the proper recommended cable size as below.
Suggested Cable Requirement for PV Wires:
| Typical Amperage | Gauge | Torque Value |
|---|---|---|
| 10A | 12AWG | 1.4~1.6Nm |
PV Module Selection:
When choosing the right PV module, be sure to first consider the following requirements:
The open circuit voltage (Voc) of the PV modules does not exceed the maximum PV array open circuit voltage of the inverter. The maximum supply voltage of the PV modules should be close to the optimal PV access voltage range of the inverter for best performance. If one PV module cannot meet this requirement, it is necessary to connect multiple PV modules in series.
PV Module Wire Connection:
Please follow below steps to implement PV module connection:
- Remove insulation sleeve 10 mm for positive and negative conductors.
- Suggest to put bootlace ferrules on the end of positive and negative wires with a proper crimping tool.
- Fix wire cover to the inverter with supplied screws as shown in below chart.
- Check correct polarity of wire from PV modules and PV input connectors. Then, connect positive pole (+) of connection wire to positive pole (+) of PV input connector. Connect negative pole (-) of connection wire to negative pole (-) of PV input connector. Screw two wires tightly in clockwise direction. Recommended tool: 4mm blade screwdriver.

Rear view of the inverter showing PV input terminals.
3.7 Final Assembly
After connecting all wirings, please put the bottom cover back by screwing the two screws.
3.8 Communication Connection
The inverter supports various communication methods:
- PC Connection: Use the supplied communication cable to connect to the inverter and PC. Insert the bundled CD into a computer and follow on-screen instructions to install the monitoring software. For detailed software operation, check the user manual of the software inside the CD.
- Wi-Fi Cloud Communication (Option): Use the supplied communication cable to connect to the inverter and Wi-Fi module. Download the APP and install it from the APP store. Refer to the "Wi-Fi Plug Quick Installation Guideline" to set up the network and register. The inverter status will be shown by mobile phone APP or webpage of computer.
- GPRS Cloud Communication (Option): Use the supplied communication cable to connect to the inverter and GPRS module, and then apply external to the GPRS module. Download the APP and install it from the APP store. Refer to the "GPRS RTU Quick Installation Guideline" to set up the network and register. The inverter status will be shown by mobile phone APP or webpage of computer.

Side view of the inverter showing RS232, BMS/RS485, and Dry Contact communication ports.
4. Operating
4.1 Power ON/OFF
Once the unit has been properly installed and the batteries are connected well, simply press the On/Off switch (located on the button of the case) to turn on the unit.
Steps to Start Up:
Connect the battery that meets the requirements (battery voltage needs to be beyond 23V) or AC (AC needs to confirm the suitable input range depending on the output mode), then you can start up the inverter.
- Mains Power On: Connect to normal AC power, press the switch, the system will automatically turn on. If you set AC output power priority, after waiting for a period of time, the panel will display AC mode that represents turn on the machine successfully, then will enter the AC mode.
- Battery Boot: Connect to battery, press the power-on button to establish a working power source. The system will automatically turn on, after waiting for a period of time, the panel will display battery mode that represents turn on the machine successfully, then will enter the battery mode.
Shutdown Steps:
When the system is in battery mode or AC mode output, press the switch again, then the system will be turned off.
4.2 Operation and Display Panel
The operation and display panel, shown in the chart below, is on the front panel of the inverter. It includes three indicators, four function keys, and an LCD display, indicating the operating status and input/output power information.

Front panel of the inverter with LCD display, status indicators, and function keys.
Function Keys:
| Function Key | Description |
|---|---|
| ESC | To exit setting mode |
| UP | To go to previous selection |
| DOWN | To go to next selection |
| ENTER | To confirm the selection in setting mode or enter setting mode |
LED Indicator Messages:
| LED Indicator | Messages |
|---|---|
| AC/INV (Solid On Green) | Output is powered by utility in Line mode. |
| AC/INV (Flashing Green) | Output is powered by battery or PV in battery mode. |
| CHG (Solid On Green) | Battery is fully charged. |
| CHG (Flashing Green) | Battery is charging. |
| FAULT (Solid On Red) | Fault occurs in the inverter. |
| FAULT (Flashing Red) | Warning condition occurs in the inverter. |
4.3 Operating Mode Description
The inverter operates in different modes depending on power availability and settings:
- Line Mode: The unit will provide output power from the mains. It will also charge the battery at line mode.
- Standby Mode: No output is supplied by the unit but it still can charge batteries.
- Fault Mode: Errors are caused by inside circuit error or external reasons such as over temperature, output short circuited, and so on.
Power Flow Diagrams:
The following diagrams illustrate the power flow in various scenarios:
- If "solar first" is selected priority and solar energy is not sufficient to provide the load, solar energy and the utility will provide the loads and charge the battery at the same time.

Power flow when solar is prioritized but needs utility assistance.
- If "solar first" is selected as output source priority and battery is not connected, solar energy and the utility will provide the loads.

Power flow when solar is prioritized, with utility, and no battery connected.
- Power from utility.

Power flow when only utility is used.
- Power from battery and PV energy.

Power flow when battery and PV are used.
- PV energy will supply power to the loads and charge battery at the same time.

Power flow when PV charges battery and supplies load simultaneously.
- Power from battery only.

Power flow when only battery is used.
4.4 Display Settings
The LCD display information can be switched by pressing the "UP" or "DOWN" key. The selectable information includes input voltage, input frequency, PV voltage, charging current, power, battery voltage, output voltage, load percentage, load in Watt/VA, DC discharging current, and main CPU Version.
4.5 Battery Equalization
Equalization function is added into the charge controller to reverse the buildup of negative chemical effects like stratification, a condition where acid concentration is greater at the bottom of the battery than at the top. Equalization also helps to remove sulfate crystals that might have built up on the plates. If left unchecked, this condition, called sulfation, will reduce the overall capacity of the battery. Therefore, it's recommended to equalize battery periodically.
How to Apply Equalization Function:
You must enable battery equalization function in monitoring LCD setting program 30 first. Then, you may apply this function in device by either one of following methods:
- Setting equalization interval in program 35.
- Active equalization immediately in program 36.
When to Equalize:
In stage, when the setting equalization interval (battery equalization cycle) is arrived, or equalization is active immediately, the controller will start to enter Equalize stage.
Equalize Charging Time and Timeout:
In Equalize stage, the controller will supply power to charge battery as much as possible until battery voltage raises to battery equalization voltage. Then, constant-voltage regulation is applied to maintain battery voltage at the battery equalization voltage. The battery will remain in the Equalize stage until setting battery equalized time is arrived.
However, in Equalize stage, when battery equalized time is expired and battery voltage doesn't rise to battery equalization voltage point, the charge controller will extend the battery equalized time until battery voltage achieves battery equalization voltage. If battery voltage is still lower than battery equalized voltage when battery equalized timeout setting is over, the charge controller will stop equalization and return to float stage.
5. Maintenance
To ensure optimal performance and longevity of your DATOUBOSS inverter, regular maintenance is recommended. Keep the unit clean and free from dust and debris. Periodically check all electrical connections to ensure they are secure and free from corrosion. Ensure proper ventilation around the unit to prevent overheating. For any complex maintenance or repairs, always consult with qualified service personnel.
6. Troubleshooting
6.1 Troubleshooting Table
| Problem | LCD/LED/Buzzer | Explanation/Possible cause | What to do |
|---|---|---|---|
| Unit shuts down automatically during startup process. | LCD/LEDs and buzzer will be active for 3 seconds and then complete off. | The battery voltage is too low (<1.91V/Cell) | 1. Re-charge battery. 2. Replace battery. |
| No response after power on. | No indication | 1. The battery voltage is far too low. (<1.4V/Cell) 2. Internal fuse tripped. | 1. Contact repair center for replacing the fuse. 2. Re-charge battery. 3. Replace battery. |
| Input voltage is displayed as 0 on the LCD and green LED is flashing. | Input protector is tripped | Check if AC breaker is tripped and AC wiring is connected well. | |
| Mains exist but the unit works in battery mode. | Green LED is flashing | Insufficient quality of AC power. (Shore or Generator) | 1. Check if AC wires are too thin and/or too long. 2. Check if generator (if applied) is working well or if input voltage range setting is correct. (UP-->sppliance) |
| Green LED is flashing. | Set "Solar First" as the priority of output source. | Change output source priority to Utility first. | |
| When the unit is turned on, internal relay is switched on and off repeatedly. | LCD display and LEDs are flashing | Battery is disconnected. | Check if battery wires are connected well. |
| Fault code 07 | Overload error. The inverter is overload 105% and time is up. | Reduce the connected load by switching off some equipment. | |
| Fault code 05 | If PV input voltage is higher than specification, the output power will be derated. At this time, if connected loads is higher than derated output power, it will cause overload. | Reduce the number of PV modules in series or the connected load. | |
| Output short circuited. | Check if wiring is connected well and remove abnormal load. | ||
| Buzzer beeps continuously and red LED is on. | Fault code 02 | Temperature internal converter component is over 120°C. | Check whether the air flow of the unit is blocked or whether the ambient temperature is too high. |
| Fault code 03 | Internal temperature of inverter component is over 100°C | Return to repair center. | |
| Fault code 01 | Battery is over-charged | Check if spec and quantity of batteries are meet requirements. | |
| Fault code 06/58 | The battery voltage is too high. | Replace the fan. | |
| Fault code 08/09/53/57 | Output abnormal (Inverter voltage below than 190Vac or is higher than 260Vac) | 1. Reduce the connected load. 2. Return to repair center | |
| Fault code 51 | Internal components failed. | Return to repair center. | |
| Fault code 52 | Over current or surge. | Restart the unit, if the error happens again, please return to repair center. | |
| Fault code 55 | Bus voltage is too low. | ||
| Fault code 59 | Output voltage is unbalanced. | Reduce the number of PV modules in series. | |
| PV input voltage is beyond the specification. |
6.2 Warning Indicator
When a warning condition occurs, the red LED flashes, and the LCD displays an alarm code. The inverter does not enter a full failure mode.
| Warning Code | Warning Event | Audible Alarm | Icon flashing |
|---|---|---|---|
| 01 | Fan is locked when inverter is on. | Beep three times every second | DA |
| 02 | Over temperature | None | 02- |
| 03 | Battery is over-charged | Beep once every second | 03- |
| 04 | Low battery | Beep once every second | 04 |
| 07 | Overload | Beep once every 0.5 second | DTA 100% OVER LOAD |
| 10 | Output power derating | Beep twice every 3 seconds | 10 |
| 15 | PV energy is low. | Beep twice every 3 seconds | SA |
| 16 | High AC input (>280VAC) during BUS soft start | None | 164 |
| 49 | Battery equalization | None | EQA |
| 69 | Battery is not connected | None | БРА |
6.3 Code Reference
Related information code will be displayed on the LCD screen. Please check the inverter LCD screen for the operation.
| Code | Description |
|---|---|
| 60 | If battery status is not allowed to charge and discharge after the communication between the inverter and battery is successful, it will show code 60 to stop charging and discharging battery. |
| 61 | Communication lost
|
| 69 | If battery status is not allowed to charge after the communication between the inverter and battery is successful, it will show code 69 to stop charging battery. |
| 70 | If battery status must to charge after the communication between the inverter and battery is successful, it will show code 70 to charge battery. |
| 71 | If battery status is not allowed to discharge after the communication between the inverter and battery is successful, it will show code 71 to stop discharge battery. |
7. Specifications
7.1 Technical Datasheet (Model DT2430)
| Category | Parameter | DT2430 |
|---|---|---|
| Input | Input Sources | L+N+PE |
| Rated Input Voltage | 220/230/240VAC | |
| Voltage Range | 90-280VAC±3V (APL Mode) 170-280VAC±3V (UPS Mode) | |
| Output | Rated Capacity | 3000W |
| Output Voltage | 220/230/240VAC±5% | |
| Output Frequency | 50/60Hz±0.1% | |
| Waveform | Pure Sine Wave | |
| Transfer Time (adjustable) | Computers (UPS Mode) 10ms, Appliance (APL Mode) 20ms | |
| Peak Power | 6000VA | |
| Battery | Peak Efficiency (battery Mode) | >94% |
| Battery Voltage | 24Vdc | |
| Constant Charging Voltage (Adjustable) | 28.2Vdc | |
| Float Charging Voltage (Adjustable) | 27Vdc | |
| Chargers | PV Charging Mode | MPPT |
| MAX.PV Input Power | 3000W | |
| MPPT Tracking Range | 40~500Vdc | |
| Best voltage | 300~400Vdc | |
| MAX.PV Input Voltage | 500Vdc | |
| MAX.PV Charging Current | 100A | |
| MAX.AC Charging Current | 60A | |
| Display | LCD Display | Display Running Mode/Loads/Input/Output etc. |
| RS232 Communication Port | Baud Rate 2400 | |
| Interface | Communication Port | Lithium Battery BMS Communication Card WifiCard, Dry Contact |
| Parallel Connect Interface | No parallel function | |
| Environments | Operating Temperature | -10~50℃ |
| Humidity | 20%~95% (Non-condensing) | |
| Storage Temperature | -15~60℃ | |
| Altitude | Altitude Not Over 1000m, Derating over 1000m, Max 4000m, Refer to IEC62040 | |
| Noise | ≤50db |
7.2 Additional Product Properties
| Attribute | Value |
|---|---|
| High-concerned chemical | none |
| EU LVD Voltage | Low voltage: Below 50Vac or 75Vdc |
| Model Number | DT2430-A-EU |
| Size | 48.00 x 37.50 x 18.20 cm |
| Output Type | SINGLE |
| Weight | 7.7800 kg |
| Brand Name | DATOUBOSS |
| Output Frequency | 50Hz |
| Is Smart Device | Yes |
| Origin | Mainland China |
| Certification | CE |
| Rated Capacity | 3000VA / 3000W |
| Input Voltage | 24V |
| Output Voltage | 230V |
| Solar Voltage | Max 500VDC |
| Optimum voltage range | 300-400VDC |
| Solar Voltage Range | 40-500vdc |
| Charging current | Max 100A |
| Operating Temperature Range | -10 - 50℃ |
| DC Input | 24VDC, 138.9A |
| AC Charger | 27VDC, 60A |
| Protection Degree | IP21 |
8. Warranty and Support
For warranty information, please refer to the terms and conditions provided at the time of purchase or contact your seller directly. For technical support, troubleshooting assistance beyond this manual, or service inquiries, please contact the DATOUBOSS customer service or an authorized service center.
A user manual in PDF format is available for download: User manual (PDF).
9. User Tips
- Easy Installation: Users have noted the equipment is easy to install, making setup straightforward.
- Check Dimensions: Before purchasing or installing, verify the actual dimensions of the converter to ensure it fits your intended space.