Micsig AHO14-200

Rate this product if you’ve used it
Contents

Micsig AHO14-200 High Resolution Automotive Oscilloscope

User Manual

1. Product Overview

The Micsig AHO1 Series is a professional high-resolution automotive oscilloscope designed for vehicle diagnostics. This ultra-portable device features a 12-bit high-precision ADC, a bandwidth of up to 200MHz, 4 analog channels, a real-time sampling rate of 1GSa/s, and a storage depth of 110Mpts. Its slim 3.1 cm design, coupled with a built-in high-capacity Li-ion battery and USB Type-C charging, makes it ideal for mobile and outdoor repair applications.

With an innovative general/automotive dual-software architecture and dedicated test modes for engines, sensors, and EV systems, the AHO14-200 supports both Internal Combustion Engine (ICE) and new energy vehicle diagnostics, helping technicians troubleshoot faster and improve service efficiency. It is equipped with an 8-inch high-definition anti-glare touch screen with a resolution of 1280x800 pixels, offering a clear picture and responsive touch for an ultimate operating experience.

Micsig AHO14-200 Automotive Oscilloscope front view

Figure 1.1: Micsig AHO14-200 Automotive Oscilloscope

Play video
Watch video online

Video 1.1: Micsig AHO14-200 Product Demonstration

2. Key Features

  • 12-bit Vertical Resolution: Offers up to 4096 quantization levels, 16 times that of traditional 8-bit ADCs, for unmatched waveform detail.
  • High Bandwidth & Sampling Rate: 200MHz bandwidth and 1GSa/s real-time sampling rate for precise signal analysis.
  • 4 Analog Channels: Simultaneous measurement across multiple points.
  • Deep Memory: 110Mpts memory depth ensures excellent signal fidelity even with long timebase signals.
  • Integrated 4½-digit Multimeter: Supports voltage, current, resistance, continuity, diode, and capacitance measurements.
  • Ultra-thin & Portable Design: Only 3.1cm thick, easily fits into a backpack.
  • Built-in 16000mAh Li-ion Battery: Long-life battery with over 1000 charge-discharge cycles, supports power bank charging.
  • 8-inch TFT LCD Capacitive Touch Screen: 1280x800 pixel resolution with anti-reflection, anti-fingerprint, anti-glare, and scratch-resistant properties.
  • Multiple Remote Control Methods: Supports PC and mobile APP remote control, SCPI commands, and HDMI direct connection to displays.
  • Advanced Trigger Functions: Includes Edge, Pulse Width, Logic, N Edge, Runt Pulse, Slope, Time Out, Video, and Serial triggers.
  • Serial Bus Decoding: Supports RS-232/422/485/UART, CAN, CAN FD, LIN, SPI, I2C, ARINC-429, MIL-STD-1553B.
  • Hardware Digital Filtering: Selectively allows or blocks signal components within specific frequency ranges.
  • Advanced Math Functions: Supports addition, subtraction, multiplication, division, integration, differentiation, and FFT.
  • Segmented Storage: Divides storage into small segments to capture multiple trigger events efficiently.
  • Built-in Electronic Tools: Includes electronic calculator, WPS office, and ES file explorer.
Micsig AHO14-200 with key features highlighted

Figure 2.1: Key Features of the AHO14-200 Oscilloscope

Micsig AHO14-200 8-inch Full HD Touch Display

Figure 2.2: 8-inch Full HD Touch Display with Anti-Glare Features

Micsig AHO14-200 Slim Body Design

Figure 2.3: Slim 3.1cm Body Design

Micsig AHO14-200 Built-in Lithium Battery

Figure 2.4: Built-in 16000mAh Lithium-ion Battery

3. Setup

3.1 Unpacking and Inspection

Carefully unpack the oscilloscope and all accessories. Verify that all items listed in the 'Standard Accessories' section (Section 6) are present and undamaged. If any items are missing or damaged, contact customer support immediately.

3.2 Powering On the Device

The AHO14-200 can be powered using the included DC 12V power adapter or via a Type-C 5V power bank. Ensure the device is adequately charged before use, especially for mobile applications.

  • Connect the power adapter to the DC 12V input port on the rear of the oscilloscope.
  • Alternatively, connect a compatible Type-C power bank to the Type-C port for charging and operation.
  • Press the power button (usually located on the front panel) to turn on the device.

3.3 Connecting Probes and Cables

Connect the passive probes to the BNC input channels (CH1, CH2, CH3, CH4) on the front panel. For multimeter functions, use the provided multimeter pens with the COM, mA, and 10A ports.

Rear view of Micsig AHO14-200 showing connectivity ports

Figure 3.1: Universal Connectivity Hub (Rear Panel)

3.4 Initial Calibration

The oscilloscope supports self-calibration. It is recommended to perform a self-calibration upon initial setup or if measurement accuracy is critical. Refer to the 'System' menu in the device settings for the self-calibration option.

4. Operating Instructions

4.1 User Interface and Operation Modes

The AHO14-200 offers three operation modes: fully touchscreen, physical buttons and knobs, and a hybrid approach. The SigTest UI is designed for swift and simplified task completion.

  • Touchscreen: All operations can be performed directly on the 8-inch capacitive touch screen.
  • Physical Controls: Use the dedicated knobs and buttons on the right panel for vertical scale, horizontal position, trigger level, and menu navigation.
Micsig AHO14-200 with touch screen interaction

Figure 4.1: Touch Screen Interaction

4.2 Oscilloscope Functions

  • Vertical System: Adjust vertical scale (mV/div to V/div) and position for each channel.
  • Horizontal System: Control time base (ns/div to s/div) and horizontal position.
  • Trigger System: Set trigger mode (Auto, Normal, Single), trigger level, and select trigger types (Edge, Pulse Width, Logic, etc.).
  • Acquisition Modes: Normal, Average, Peak Detect, High Resolution.
  • Measurements: Access automatic measurements for parameters like Period, Frequency, Rise Time, Fall Time, Peak-to-Peak, RMS, etc.
  • Math Functions: Perform waveform calculations (Add, Subtract, Multiply, Divide, FFT, etc.).
  • Digital Filtering: Apply High Pass or Low Pass filters to signals.
Screenshot showing Hardware Digital Filtering

Figure 4.2: Hardware Digital Filtering Options

4.3 Multimeter Functions

To use the integrated multimeter, connect the multimeter pens to the appropriate ports (COM, mA, 10A). Select the multimeter function from the menu to measure DC/AC Voltage, DC/AC Current, Resistance, Capacitance, Continuity, or Diode Test.

Micsig AHO14-200 displaying multimeter function

Figure 4.3: Integrated Multimeter Function

4.4 Automotive Diagnostic Presets

The AHO14-200 includes dedicated test modes for automotive diagnostics, simplifying common measurements:

  • Charging/Start Circuits
  • Sensors
  • Actuators
  • Ignition Systems
  • Network Protocols (CAN, LIN, etc.)
  • Combination Tests
  • Pressure Tests
Micsig AHO14-200 connected for automotive diagnostics

Figure 4.4: Automotive Diagnostic Interface

4.5 Data Storage and Connectivity

  • File Saving: Save waveforms and measurement results in WAV, CSV, or BIN formats.
  • Screenshot & Video Recording: Capture screenshots and record videos of waveforms.
  • USB & LAN: Use USB 3.0 Host, USB Type-C, and LAN ports for data transfer and remote control.
  • HDMI: Connect to external displays for larger viewing.

5. Maintenance

5.1 Cleaning

To clean the device, use a soft, dry cloth. For stubborn dirt, a slightly damp cloth with mild detergent can be used. Avoid using abrasive cleaners or solvents that could damage the screen or casing.

5.2 Battery Care

The AHO14-200 features a built-in 16000mAh Lithium-ion battery. To maximize battery life:

  • Avoid fully discharging the battery frequently.
  • Store the device in a cool, dry place when not in use for extended periods.
  • Charge the battery periodically if stored for a long time to prevent deep discharge.

5.3 Self-Calibration

The device supports self-calibration to maintain measurement accuracy. It is recommended to perform self-calibration periodically or if you suspect any drift in measurements. Access this function through the system settings menu.

6. Specifications

CategoryParameterSpecification
GeneralModelAHO14-200
Brand NameMicsig
Bandwidth200MHz
Analog Channels4
Real Time Sampling Rate1GSa/s
Memory Depth110Mpts
Max Waveform Capture Rate50,000 wfms/s
Display8" TFT LCD capacitive touch screen, 1280*800 pixels
Battery3.7V, 16000mAh Lithium-ion battery
Dimension / Net Weight265*174*31mm (Width x Height x Thickness) / 1.73kg (with multimeter)
Vertical SystemDC Gain Accuracy< 1%
Bandwidth Filter20MHz, High Pass / Low Pass
CouplingDC, AC, GND
Input Impedance and Accuracy1MΩ±1%
Vertical Resolution12 Bit
Vertical Divisions10div
Vertical Scale Factor1mV/div~10V/div
Max. Input VoltageCAT I 300Vrms 400Vpk
Channel Isolation> 40dB (≤ 100MHz), > 35dB (> 100MHz)
Horizontal SystemHorizontal Scale2ns/div~1ks/div
Roll Mode Range100ms/div~1ks/div
Time Base Accuracy20ppm
Horizontal Divisions11div
Time Base Delay Time Range-11div ~ 11ks, resolution: 1 pixel
Trigger SystemTrigger ModeAuto, Normal, Single
Trigger Level Range±5div from screen center, analog channel
Hold Off Range200ns~10s
Trigger TypesEdge, Pulse Width, Logic, N Edge, Runt Pulse, Slope, Time Out, Video, Serial
Bus DecodingRS-232/422/485/UART, CAN, CAN FD, LIN, SPI, I2C, ARINC429, 1553B
Self-calibrationSupported
Sampling SystemReal-time Sampling Rate (Max.)1GSa/s (single channel); 500MSa/s (half channel); 250MSa/s (Full channel)
Memory Depth (Max.)110Mpts (single channel); 55Mpts (half channel); 27.5Mpts (Full channel)
Segmented Storage FunctionSupport up to 10,000 segments
Average Times2, 4, 8, 16, 32, 64, 128, 256
Multimeter (Optional)DC Voltage (+25°C)1000V/600V/60V/6V (±0.03%+5d), 600mV (±0.03%+5d)
AC Voltage (+25°C)1000V/600V/60V/6V (±0.3%+15d), 600mV (±0.3%+15d)
DC Current (+25°C)10A/6A (±0.2%+5d), 600mA/60mA (±0.15%+5d)
Resistance (+25°C)6MΩ/600KΩ/60kΩ/6kΩ/600Ω (±0.1%+5d), 60MΩ (±0.2%+10d)
Capacitance (+28°C)1mF/100uF/10uF/100nF/10nF (±3%+30d)
ContinuityBuzzer when < 50Ω; Displays "OL" (Overload) when > 200Ω
Diode Test0.0000V~3.0000V, Displays "OL" when > 3.0V
Measurement DisplayMax / Avg / Min values (all with timestamp recording)
Multifunction Meter Accuracy4½ Digits
NoteMultimeter is not included in models with the "N" symbol.
InterfacesUSB3.01, read and edit
USB Type-C1, read and edit, support charging with power bank
LAN1
DC Power Socket1
Probe Calibration Signal1kHz, 2Vpk-pk
HDMIHDMI 1.4
PC SoftwareSupport
Android/iOS Remote Control APPSupport
Power SupplyAdapter Input100~240V AC, 50/60Hz
Power Consumption60W
Adapter Output12V DC, 5A
EnvironmentOperating Temperature0°C ~ 45°C
Non-operating Temperature-40°C ~ 60°C
Operating Humidity5%~85%, 25°C
Non-operating Humidity5%~90%, 25°C
Operating Altitude< 3000m
Non-operating Altitude< 12000m

7. Standard Accessories

The following accessories are included with your Micsig AHO14-200 oscilloscope:

  • Main unit *1
  • Passive Probe *4
  • Multimeter pen *1 pair (Note: Not included in models with the "N" symbol)
  • Power adapter *1
  • Power cord *1
  • Quick Guide *1
  • Calibration Certificate *1
  • Battery *1
Standard accessories kit for Micsig AHO14-200

Figure 7.1: Standard Accessories Kit

Optional Accessories

Micsig offers a range of optional accessories to enhance the functionality of your oscilloscope, including various High Voltage Differential Probes, High Frequency AC/DC Current Probes, and SigOFIT Optical-fiber Isolated Probes. Please refer to the official Micsig website for a complete list and details.

8. Troubleshooting

This section provides general troubleshooting tips for common issues. For more detailed diagnostics, please refer to the full user manual PDF or contact Micsig support.

8.1 No Power

  • Ensure the power adapter is securely connected to both the oscilloscope and a working power outlet.
  • Check if the power cord is damaged.
  • Verify that the built-in battery is charged. If not, connect the power adapter and allow it to charge for some time.
  • Press and hold the power button for a few seconds to ensure it's not a momentary press.

8.2 No Signal Displayed

  • Check if the probes are correctly connected to the input channels and the test points.
  • Verify that the probe attenuation settings on the oscilloscope match the physical probe (e.g., 1X, 10X).
  • Adjust the vertical scale (Volts/div) and horizontal time base (Time/div) to an appropriate range for the expected signal.
  • Check the trigger settings. Ensure the trigger level is within the signal's amplitude and the trigger mode is suitable (e.g., Auto mode for general signals).
  • Ensure the input coupling (DC, AC, GND) is set correctly for your signal.

8.3 Inaccurate Measurements

  • Perform a self-calibration of the oscilloscope.
  • Ensure probes are properly compensated.
  • Check for external interference or noise sources.
  • Verify that the correct measurement parameters are selected.

9. User Tips

  • Optimize Battery Life: For extended outdoor use, consider carrying a compatible Type-C power bank to supplement the internal battery.
  • Leverage Automotive Presets: Utilize the dedicated automotive diagnostic presets to quickly set up common vehicle tests, saving time and reducing configuration errors.
  • Explore Connectivity: Use the HDMI output to connect to a larger monitor for easier viewing during collaborative work or detailed analysis.
  • Data Management: Regularly save important waveforms and measurement data to a USB drive or transfer to a PC for long-term storage and analysis.

10. Warranty and Support

10.1 Warranty Information

The Micsig AHO14-200 mainframe comes with a three-year warranty. Please note that probes and other accessories are not covered under this warranty. For specific warranty terms and conditions related to probes and accessories, please contact Micsig directly or refer to their official website.

10.2 Customer Support

For technical assistance, troubleshooting, or any product-related inquiries, please contact Micsig customer support:

  • Email: sales@micsig.com
  • Website: www.micsig.com
  • Address: 6F, Jinhuanyu Building, No. 56, Tiezai Rd, Bao'an District, Shenzhen, Guangdong, China.

10.3 User Manual (PDF)

A detailed user manual in PDF format is available for download, providing comprehensive instructions and advanced usage scenarios. You can access it via the following link: Micsig AHO1 Series User Manual (PDF)

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.

Was this page helpful?