1. Introduction
The MYOSLIM Sculpting NEO RF Machine utilizes advanced HI-EMT (High-Intensity Focused Electromagnetic) technology, combined with RF (Radiofrequency), to induce powerful muscle contractions and promote fat reduction and skin tightening. This device is designed to help users achieve body sculpting, muscle building, and fat burning through scientific fitness principles.
Key features include a touch-controlled display for easy operation, real-time monitoring of treatment progress, and flexible upgrade options to meet evolving therapeutic needs.
2. Important Safety Instructions
DANGER: Risk of Electric Shock
Do not open the device casing. No user-serviceable parts inside. Refer servicing to qualified personnel only.
CAUTION: General Safety Guidelines
- This device is for adult use only. Do not use on minors or individuals without a health clearance certificate.
- Do not use if you have metal implants, heart disease (especially with pacemakers), cancer, diabetes, or are pregnant/lactating/menstruating.
- Remove all metal jewelry before operation. Avoid contact with open wounds.
- Do not use on a full stomach. Allow at least 1 hour after meals and refrain from eating/drinking during and 1 hour post-treatment.
- Never replace the treatment handle while the device is powered on. Always turn off the power and calibrate the handle before replacement.
- Keep away from strong electromagnetic sources. Do not daisy-chain multiple devices on a single power outlet.
- This product is intended to be used in dry areas only.
SAVE THESE INSTRUCTIONS
This symbol stands for "European Conformity", which declares conformity with all relevant EU health, safety and environmental protection regulations.
3. Setup and Preparation
3.1 Handle Exchange
The handle must be calibrated every time it is installed or replaced. When replacing the handle, you must turn off the power of the machine. The handle cannot be replaced when the machine is powered on.
3.2 Device Start Up/Shut Down
- Connect one end of the power cord to the machine and plug the other end into the main socket. Do not connect multiple machines to the same socket.
- Move the manual switch on the rear panel to the "o" position.
- Press the power button on the front panel.
- When the treatment is finished, press and hold the power button to turn off the machine.

3.3 Preparing for Therapy
Before starting a therapy session, ensure the following:
- Communicate with patients about the procedure and expectations.
- Ensure the patient is in good health and meets the patient profile criteria.
- Ensure the patient is adequately hydrated.
- The patient should wear appropriate, comfortable clothing.
- Advise the patient to avoid eating large quantities before the session.
- Ensure familiarity with the treatment process.
- Advise the patient to avoid alcohol consumption before and after treatment.
3.4 Placing the Handle
Proper placement of the treatment handles is crucial for effective and safe therapy. Refer to the diagrams below for correct handle positioning on various body parts.


4. Operating Instructions
The device features a diversified touch screen for intuitive control. The main interface allows navigation through 'List', 'Pattern', and 'Records'.
4.1 Navigation Controls and Therapy Settings
The treatment interface displays the following items and functions:
- Navigation controls: Access different sections of the interface.
- Channels selector: Choose which handles (A or B) are active.
- Stop therapy: Immediately halt the current treatment.
- Start/pause therapy: Begin or temporarily stop a treatment session.
- Setting up therapy parameters: Adjust intensity, time, and frequency.

4.2 Unit Settings
Access the settings menu by clicking the gear icon. Here you can configure various aspects of the machine:
- Language settings: Select the desired language (English, Spanish, Portuguese, Chinese, French, Russian, and other 8 languages are supported).
- Sound adjustment: Control the device's audio output.
- Brightness adjustment: Modify screen brightness for optimal visibility.
- Set date/time: Configure the current date and time.
- System adjustment: Access system-level configurations.
- Technician: Restricted access for service personnel.

4.3 Therapy Modes
The machine offers different therapy modes with adjustable parameters:
- Mode 1: Frequency range of 5-60Hz. Adjust intensity and time as needed.
- Mode 2: Frequency range of 30-100Hz. Allows adjustment of intensity, stage frequency, and time.
Note: Adjust the corresponding intensity according to customer needs. If the customer requests to pause, click start/pause. The work button suspends the work, and you can directly click the back button to return after the work is completed.
4.4 Operation Demonstration Video
5. Maintenance
5.1 Daily Inspection
- Regularly inspect instruments and components.
- Ensure the power socket has a reliable connection to the ground.
- Check if the power cord is damaged before use. Stop using the instrument if damaged.
5.2 Cleaning
- Instrument cleaning should be performed regularly for sanitation.
- The device housing can be wiped with a damp cloth, soapy water, or a neutral detergent while the instrument is powered off.
- The logo is silk screen printed. Other parts are spray painted. Use cotton paper towels or ordinary toilet paper moistened with water to wipe clean. Do not use alcohol-based detergents on these parts.
- Accessories that come into contact with the patient's skin should be cleaned and disinfected with 75% alcohol before and after each use. Do not soak directly in alcohol-based detergent; wipe with pure cotton material.
5.3 Fuse Replacement
The fuse is located below the handle junction on the back of the machine. An additional spare fuse is included. To prevent electric shock, always turn off the power and unplug the power plug before replacing the fuse.
5.4 Transport and Storage
- Store the instrument in its original packaging box in a well-ventilated room.
- Ensure the packaging box is padded.
- Ambient temperature should be -10°C to 40°C.
- Relative humidity should not be greater than 93%.
- Do not store near flammable, explosive, or corrosive gases/substances.
- During loading, unloading, and transportation, prevent severe vibration and shock.
- Protect from moisture.
6. Troubleshooting
Refer to the table below for common issues and their solutions:
| Fault Phenomenon | Causes | Exclusions and Workarounds |
|---|---|---|
| Device not working |
|
|
| Handle not working | Check the handle for loose connection | Reseat the handle |
7. Specifications
7.1 General Product Specifications
| Attribute | Value |
|---|---|
| Brand Name | MYOSLIM |
| Item Type | Massage & Relaxation |
| Material | ABS & TPR |
| Power Supply | None Electric |
| Voltage | AC220V/50Hz AC110V/60Hz |
| Origin | Mainland China |
| Certification | CE, RoHS |
| Warranty time | One-year warranty |
| Technology | HIEMT+RF 2 in 1 Slimming, High Intensity Pulsed Electromagnetic Body Sculpting |
| Product Name | Body Sculpt Machine, E HIEMT Body Slimming Sculpting Machine |
| Power | 0--6500W |
| Frequency | 0-200HZ |
| Usage time | Three times a week, 30-40 minutes each time. |
| Functions | Tightens the skin, Shaping the hips and repairing the pelvic floor muscles (pelvic floor muscles can only be repaired through the cushion handle), Removes cellulite and rejuvenates the skin, Gains muscle. |
| Language | English, Spanish, Portuguese, Chinese, French, Russian and other 8 languages |
| After-sales service | Video technical support, online support, 24 hours online service, Instructions operation video training |
| Customization of support | Simple logo on the boot interface or fuselage appearance (cannot be infringing trademarks, customized products do not support no reason to return, can only be shipped from China) |
7.2 Electromagnetic Compatibility (EMC)
The device has undergone electromagnetic field immunity testing to ensure compliance with relevant standards.
| Attribute | Value |
|---|---|
| Port | Enclosure |
| Basic Standard | IEC 61000-4-3:2020 |
| Test Level | 30V/m with 80% AM, 1kHz Modulation |
| Standard require | A |
| Tester | Sam Liu |
| Temperature | 25°C |
| Humidity | 54% |
7.3 Block Diagram of Test Setup
The test setup involves a 7x4x3 meter chamber. Inside, the Equipment Under Test (EUT) and its support are positioned. A Power Amplifier, Signal Generator, and PC Controller are used, along with EUT Monitoring via a camera, all managed from a Control Room. The EUT is placed 0.8m from the ground, and the setup includes a 1.5m distance from the chamber wall to the EUT, and 3m from the signal source to the EUT.
8. User Tips
- Familiarize with Features: Take time to explore all intensity levels, session modes, and design features to maximize treatment effectiveness.
- Consistent Use: For optimal results in body sculpting, muscle building, and fat reduction, consistent and regular use as per recommended guidelines is advised.
- Customer Support: If you have any questions or need assistance with the device, do not hesitate to contact customer service. They are responsive and helpful.
9. Warranty and Support
9.1 Warranty Information
- The main instrument has a one-year warranty from the date of purchase (excluding man-made damage and fragile parts).
- Accessories have a 3-month warranty (excluding man-made damage).
- A new machine can be replaced within 7 days of purchase if the appearance is intact.
- Free warranty service is not provided for failures caused by: unauthorized disassembly/modification, accidental falls, lack of reasonable maintenance, or failure to operate according to the instruction manual.
- After the warranty period, contact the manufacturer for paid after-sales service.
- Any unpacking without consent will void the warranty.
9.2 Manufacturer
Guangzhou Xinwei Electronic Technology Co., Ltd.
9.3 Additional Resources
For a comprehensive guide and detailed instructions, you can refer to the official user manual PDF: User Manual (PDF).