HITBOX MIG250

Contents

HITBOX MIG250 6-in-1 Multi-Process Welder User Manual

Model: MIG250

1. Safety Precautions

Welding may result in injury to you and others. Please implement protection during welding. Refer to the Safety Protection Guidebook for Operator for more details on accident prevention.

Operate this equipment by trained professional only!

  • Use welding labor protection supplies with approval of safety supervisory authority.
  • Operators must be special workers with valid work permits of "Metal Welding (Gas Cutting) Operation".
  • Do not maintain and repair welder with power.

Electric shock - may result in severe injury or death!

  • Install grounding device according to application standard.
  • Do not touch live parts with naked skin, wet gloves or wet clothes.
  • Be sure you are insulated from ground and workpiece.
  • Confirm the safety of your working position.

Smoke - can harm your health!

  • Keep your head away from the smoke to avoid inhalation of waste gas in welding.
  • Keep the working environment well ventilated with exhaust or ventilation equipment when welding.

Arc radiation - may hurt your eyes and burn your skin!

  • Use proper welding mask and wear protective clothing to protect your eyes and body.
  • Use proper mask or curtain to protect onlooker from being injured.

Improper use and operation may result in fire or explosion

  • Welding spark may result in fire, so make sure there are no inflammables near the welding position, and pay attention to fire safety.
  • Ensure there is fire extinguisher nearby, and make sure someone has been trained to operate the fire extinguisher.
  • Do not weld closed containers.
  • Do not use this machine for pipe thawing.

Hot workpiece can cause severe scald.

  • Do not touch hot workpiece with bare hands.
  • Cool the welding torch for a while after continuously working.

Excessive noise does great harm to people's hearing.

  • Wear ear covers or other hearing protectors when welding.
  • Give warning to onlookers that noise may be potentially hazardous to hearing.

Magnetic field can make cardiac pacemaker a bit wonky.

  • People with cardiac pacemakers should stay away from the welding spot before consulting their doctor.

Moving parts may injure your body.

  • Please keep away from moving parts (like fan).
  • Each door, panel, cover, baffle plate, and protective device should be closed and located correctly.

Seek professional support when trouble strikes.

  • When trouble strikes in installation and operation, please inspect according to related contents in this manual.
  • If you still cannot understand fully, or you still cannot solve the problem, please contact the dealer or the service center to obtain professional support.

Replacing components can be dangerous.

  • Only professionals can replace machine components.
  • Make sure there is nothing left such as wire leads, screws, gaskets, and metal bars in the machine when replacing components.
  • Make sure the internal connection of machine is correct after replacing the PCBs, then the machine can be operated. Otherwise, machine may be damaged.

Precautions for scrapping

Pay attention to the following when discarding the welding machine:

  • Burning electrolytic capacitors in the main circuit or on the PCBs may cause an explosion.
  • Burning plastic parts like the front panel will result in toxic gases.
  • Dispose of the machine as industrial waste.

2. Product Overview

The HITBOX MIG250 is a 6-in-1 multi-process synergic welder designed for versatile welding applications. It supports MMA, TIG, MIG, Gasless self-shielded arc welding, and Spot welding. Its unique electric structure and air passage design enhance heat rejection and improve duty cycles. The machine features a coherent streamline form with matte front and rear panels for a comfortable grip.

Hitbox MIG250 Welder with accessories
The Hitbox MIG250 6-in-1 Multi-Process Welder with included accessories.
Integrated Welder features including IGBT technology, 220V voltage, single pulse, and synergy management.
Key features of the integrated welder: IGBT technology, 220V voltage, single pulse, and synergy management. Welding current range is 20-250A.

3. Function Overview

Versatility

  • MMA/TIG/MIG/Gasless self-shielded arc welding are available.
  • Synergic MIG: Welding parameters can be automatically selected based on welding current.
  • 2T/4T: Realizes wide application, easy welding, and outstanding performance.
  • Hot start: Makes arc ignition in MMA welding easier and more reliable.
  • Arc force current: Improves machine performance in long-cable welding and contributes to long-distance welding.
  • Anti-stick current: Improves welding performance to prevent stickiness.
  • VRD: Reduces the risk of electric shock to ensure operator's safety.
  • Functions such as accurate preset current/voltage, 2T/4T, spot welding operation mode, synergic, wire diameter selection, material selection, and other functions are available.
  • Adaptive crater: Unnecessary manual adjustment.
Diagram showing 6-in-1 Multi-Process Welder capabilities: Flux Core Welding, Gas MIG Welding, Spool Gun Welding, Lift TIG Welding, Stick Welding, Pulse MIG Welding.
The MIG250 supports 6 welding processes: Flux Core, Gas MIG, Spool Gun (additional purchase), Lift TIG, Stick/MMA, and Pulse MIG.

4. Technical Specifications

Technical Specification table for MIG250 welder, showing input voltage, current, welding ranges, duty cycle, and other electrical parameters.
Technical specifications of the MIG250 welder.
MIG250 Technical Parameters
Technical ParameterUnitsMIG-250 (220V)MIG-250 (110V)
Rated input voltageVAC220V±15%AC110V/220V±15%
Rated input powerKVA6.94.5
Rated input currentA20~18020~120
Welding current range (MMA)A20~18020~120
Welding current range (TIG)A20~18020~120
Welding voltage range (MIG)A20~18020~120
Wire feed speed rangem/min2.0~15
Rated duty cycle%40
Open circuit voltageVU0: 64 Ur:15
Overall efficiency%85
Enclosure classIP21S
Power factorCOSφ0.72
Insulation classH
StandardEN IEC 60974-1 / IEC 60974-1
Noisedb<70

Note: Tested at 40°C.

Machine Overview showing Digital Panel, Output Terminals, Spool Gun Socket, Euro Connector, Input Power Cable, Power Switch, Gas Inlet, and Fan.
Machine Overview: Front and rear panels with labeled components.

5. Operation Control and Description

5.1 Multi-function Digital Operation Panel

Detailed view of the MIG250 control panel with numbered labels for each function.
Detailed view of the MIG250 control panel.
  1. Setting parameters
  2. Spot welding diameter setting
  3. Welding mode
  4. Collaboration mode
  5. MIG operation mode
  6. MIG material setting
  7. Spot welding voltage and time adjustment
  8. Adjustment of amperage and wire feed speed
  9. Inductance adjustment knob
  10. Connection port for wire drawing torch

5.2 Detailed Function Description

Attention! Please select welding functions according to welding requirements. During welding, choose proper welding process and parameters according to the technology requirements of workpiece. With improper welding process and parameters, there will be unstable arc, excessive spatter and wire and electrode sticking during welding.

Parameter Group (M)

The "M" function supports storage and usage of ten parameter groups (0~9). Each group covers all adjustable parameters on the machine panel, including welding mode and related conditions. The machine automatically saves adjusted parameters (after keeping them for 20 seconds) for the next weld. The last used parameters are retained when the machine is turned on again.

MIG Welding Mode: Synergic and Separated

The MIG250 offers two MIG/MAG welding modes: "synergic" and "separated".

  • Synergic: The welder automatically matches preset current and welding voltage based on the welding wire, wire diameter, and gas. Users can adjust inductance. The panel displays preset current on the right LED and preset voltage on the left LED. The synergic database auto-matches voltage with an adjustment range of ±3.0V.
  • Separated: Wire feed speed and voltage adjustments are independent, requiring manual setting.

Matching Table for Welding Wire, Diameter, Shielding Gas, Material, and Wire Feeding Roll

In synergic mode, different welding wire, diameter, shielding gas, material, and wire feeding roll have corresponding matching relationships. Select correct settings for optimal welding performance.

MIG Welding Parameters
MaterialWire TypeDrive RollerGas Flow RateGas TypeWireWelding Thickness (Welding Current)
1mm2mm3mm4mm4.5mm
SteelSolid ER70S-6V Groove8-12 l/min100% CO2 / 20% CO2 + 80% Argon0.6mm-----
0.8mm25-4050-70100-120150-160180-200
0.9mm25-4050-70100-120150-160180-200
Flux CoreFlux Core E71T-GSV Groove--0.8mm25-4050-70100-120150-160180-200
0.9mm25-4050-70100-120150-160180-200
1.0mm25-4050-70100-120150-160180-200
StainlessER308LSiV Groove8-12 l/min20% CO2 + 80% Argon0.8mm-----
0.9mm-----
1.0mm-----
AluminiumER5356U Groove8-12 l/min100% Argon1.0mm80140160200-
MIG Welding Parameters table showing material, wire type, drive roller, gas flow rate, gas type, wire diameter, and welding current for various thicknesses.
MIG Welding Parameters for different materials and wire types.
Stick & Lift TIG Welding Parameters
ModeMaterialElectrode TypeElectrode DiameterWelding Current (A)
1/16" 1.6mm3/32" 2.5mm1/8" 3.2mm5/32" 4.0mm
MMASteelE60XXWelding Current30-6060-9080-130120-200
LIFT TIGSteelTungsten Diameter1/16" 1.6mm60-9080-115--
3/32" 2.4mm--115-165-
1/8" 3.2mm---160-200
StainlessTungsten Diameter1/16" 1.6mm40-7065-110--
3/32" 2.4mm--100-150-
1/8" 3.2mm---135-200
Stick & Lift TIG Welding Parameters table showing mode, material, electrode type/diameter, and welding current ranges.
Stick & Lift TIG Welding Parameters for different materials and electrode sizes.

6. Setup and Installation

Note: Please install the machine according to the following steps. Turn off the power switch of the distribution box before any electrical connection. The enclosure class of this machine is IP21S, so do not use it in rain.

6.1 MMA Welding Installation

Diagram showing connections for Gas MIG, MIG, Lift TIG, MMA, and wire drawing torch welding modes.
Connection diagrams for various welding modes.
  1. Connect the primary power supply cable to the appropriate voltage level based on the machine's input voltage.
  2. Ensure the primary cable is tightly connected to the power line terminal or socket to prevent oxidization.
  3. Check the voltage value with a multi-meter to ensure it's within the acceptable range.
  4. Insert the cable plug with the electrode holder into the "+" socket on the front panel of the welding machine and tighten it clockwise.
  5. Insert the cable plug with the earth clamp into the "-" socket on the front panel of the welding machine and tighten it clockwise.
  6. Ground connection is required for safety.

6.2 MIG Welding Installation

  1. Insert the torch into the EURO Connector for Torch on the front panel and tighten it.
  2. Connect the cylinder equipped with the gas regulator to the gas inlet on the rear panel of the machine with a gas hose.
  3. Insert the cable plug with the work clamp into the "-" output terminal on the front panel of the welding machine and tighten it clockwise.
  4. Insert the quick plug on the front panel into the "+" output terminal and tighten it clockwise.
  5. Install the wire spool on the spindle adapter. Ensure the groove size of the wire feed roll matches the contact tip size of the welding torch and the wire diameter being used. Release the pressure arm of the wire feeder to thread the wire through the liner, into the roll groove and then into the liner of the central connector. Adjust the pressure arm to ensure no sliding of the wire. Too high pressure will lead to wire distortion, affecting wire feeding. Press the Inching button to thread the wire out of the contact tip on the torch.
Video demonstrating the setup and operation of the MIG250 welder, including wire installation and different welding modes.

6.3 Gasless Self-Shielded Arc Welding Installation

  1. Insert the welding torch into the Euro connector for torch in MIG on the front panel of the machine and tighten it.
  2. Insert the cable plug with the work clamp into the "+" output terminal on the front panel of the welding machine and tighten it clockwise.
  3. Insert the quick plug on the front panel into the "-" output terminal and tighten it clockwise.
  4. Install the wire spool on the spindle adapter and tighten the cover of the spindle. Ensure the groove size of the wire feed roll matches the contact tip size of the welding torch and the wire diameter being used. Release the pressure arm of the wire feeder to thread the wire through the liner, into the roll groove and then into the liner of the central connector. Adjust the pressure arm to ensure no sliding of the wire. Too high pressure will lead to wire distortion, affecting wire feeding. Press the Inching button to thread the wire out of the contact tip on the torch. (Gasless self-shielded arc welding applies flux-cored self-shielded welding wire, which requires knurling rolls).

6.4 TIG Welding Installation

  1. Connect the TIG torch to the negative pole on the front panel, and the workpiece to the positive pole. Ensure the quick connector is tightened.
  2. Connect the Argon cylinder and gas inlet hose of the TIG torch. Open the gas valve after achieving suitable gas flow. Ensure connections are tight to prevent gas leakage.

Note: For TIG welding, gas is not controlled by the built-in gas valve; therefore, gas should be connected to the gas inlet hose of the TIG torch outside the machine.

7. Operating Instructions

7.1 MMA Welding Operation

  1. After installation and switching on the power, the machine starts with the power LED on and the fan working.
  2. Pay attention to polarity when connecting. Two ways of wiring on DC welder: DCNP (welding holder to "-", workpiece to "+") and DCEP (workpiece to "-", welding holder to "+"). Choose the proper connection method according to workpiece and processing methods. Unstable arc, spatter, and electrode sticking can occur with improper polarity. Change polarity by exchanging the quick connector if needed.
  3. When switching to MMA mode, welding can be carried out with output current in the rated range.
  4. Select a cable with a larger cross-section to reduce voltage drop if the workpiece is far from the welder with long secondary cables.

Preset the welding current according to the type and size of the electrode, clamp the electrode, and then welding can be carried out by short circuit arc ignition. Refer to the MMA welding parameters table for guidance.

MMA Welding Parameters (Reference Only)
Electrode Diameter (mm)Recommended Welding Current (A)Recommended Welding Voltage (V)
1.020~6020.8~22.4
1.644~8421.76~23.36
2.060~10022.4~24.0
2.580~12023.2~24.8
3.2108~14823.32~24.92
4.0140~18024.6~27.2
5.0180~22027.2~28.8
6.0220~26028.8~30.4

Note: This table is suitable for mild steel welding. For other materials, consult related materials and welding process for reference.

7.2 MIG Welding Operation

  1. After installation and switching on the power, the machine starts with the digital display on and the fan working. Open the cylinder valve and adjust the flow regulator to get the proper gas flow.
  2. Press the 2T/4T button to select the desired mode.
    • 2T: Press the torch trigger to activate wire feeding. After arc ignition, start welding based on set wire feed speed and voltage. Release the torch trigger to stop wire feeding and welding. Gas is turned off after 0.5 seconds.
    • 4T: Press the torch trigger to activate wire feeding. After arc ignition, start welding based on set wire feed speed. When releasing the torch trigger, welding continues. Press the torch trigger again; welding still continues. After releasing the torch trigger, wire feeding and welding stops. Gas is turned off after 0.5 seconds.
  3. Operators can adjust burn-back time and post-flow time based on actual demands.

7.3 Gasless Self-Shielded Arc Welding Operation

The operation is the same as MIG operation except that there is no gas option.

7.4 TIG Welding Operation

  1. After installation and switching on the power, the machine starts with the digital display on and the fan working.
  2. Select "TIG" as the welding mode.
  3. According to workpiece thickness, select welding current by adjusting the "current adjusting knob" and the ammeter displays this set value. Press the torch trigger to start welding.

Arc starting method: This machine adopts touch start TIG. Operators can start normal welding by slightly raising the torch when there is current after the tungsten is touching the workpiece.

8. Basic Knowledge of Welding

8.1 MMA (Manual Metal Arc) Welding

Welding Process

Connect the two output terminals of the welder to the workpiece and electrode holder. Clamp the electrode. Arc is ignited between the electrode and workpiece, fusing the electrode end and part of the workpiece to form a weld crater. The crater cools to form a weld joint. The electrode coating fuses to produce slag, protecting the weld crater. The cooled slag forms a crust, which is removed after welding.

Tools for MMA

  • Electrode holder: A tool for clamping the electrode and conducting current (e.g., 300A and 500A types).
  • Welding mask: Shields eyes and face from arc and spatter. Filters UV and IR rays.
  • Slag hammer (peen hammer): Used for removing slag crust from the weld joint surface.
  • Wire brush: Used for removing dirt and rust from workpiece joints before welding, and cleaning weld surface after welding.
  • Welding cable: Generally made of fine copper wires. Connects electrode holder to machine (live wire) and machine to workpiece (earth wire). Covered with insulating material.

Basic Operation of MMA

  • Welding joint cleaning: Remove rust and greasy dirt completely before welding for stable arc and quality weld. Use a wire brush for low requirement, grinding wheel for high requirement.
  • Posture in operating: For flat welding, stand at the right side of the welding direction, holding the mask in the left hand and electrode holder in the right. Place the left elbow on the left knee to prevent body movement and allow free arm movement.
  • Arc igniting: Process to produce a stable arc. Common modes are scraping and striking. Touch the workpiece surface with the electrode, then quickly lift 2-4mm to ignite. If ignition fails, remove coating from electrode end.
  • Tack weld: Short weld joints (30-40mm) welded at intervals to fix relative positions of workpiece pieces during assembly.
  • Electrode manipulation: Simultaneous movement in three directions: along welding direction, towards weld crater, and transverse swinging. Control welding angle (70-80° inclined forward), arc length (equal to electrode diameter), and welding speed (to achieve flat weld bead with fine ripples).
  • Arc extinguishing: Do not extinguish immediately. Slowly pull the electrode from the groove and raise the arc to narrow the weld crater and reduce metal/heat, preventing defects.
  • Weldment cleaning: Clean welding slag and spatter with a wire brush after welding.

8.2 GMAW (Gas Metal Arc Welding)

Overview

GMAW uses gas as arc media for protection. It's an open arc welding method, typically not using flux-cored wire, and offers high productivity. MIG (Metal Inert Gas) welding, a type of GMAW, uses continuously fed welding wire as the melting electrode and inert gas as shield gas. It's common in automotive sheet metal repair and for welding active metals like stainless steel, heat-resistant alloys, copper, and aluminum-magnesium alloys.

Classification and Application of GMAW

GMAW can be classified by shield gas, wire type, and operation mode. It's suitable for welding most metals and alloys, including carbon steel, low alloy steel, stainless steel, aluminum, copper, and magnesium alloys. Special treatment may be needed for high melting point metals. It is not suitable for metals with low melting points. Minimum welding thickness is 1mm. It has high adaptability to various welding positions.

Welding Equipment for GMAW

  • Welding source: Generally DC welding source, power depends on desired current range.
  • Wire feed system: Includes wire feeder (motor, reducer, aligning wheels, wire feed wheel), wire feed hose, and wire spool.
  • Welding torch: Semi-automatic or automatic. Air-cooled or water-cooled based on cooling method.

Basic Operation of GMAW

  • Preweld cleaning: Chemical or mechanical cleaning (sanding, scraping, sand blasting) to remove oxidation film.
  • Equipment check: Inspect for damage, missing components, and verify maintenance history. Check category, connection, grounding, and capacity.
  • Labor protection: Wear masks, protective gloves, footwear, overalls, goggles/helmet. Wear rubber overshoes in wet conditions. Avoid dust, electric shock, scalding, fire, and radiation.
  • Welding parameter selecting: Parameters include welding current, voltage, speed, stick-out, wire angle, wire diameter, welding position, polarity, shield gas type and flow.
  • Current and welding voltage: Choose wire diameter based on workpiece thickness, then decide current, metal transfer mode, and arc voltage.
  • Welding speed: Affects penetration, depth, and width of molten pool.
  • Stick-out: Longer stick-out increases resistance heat and melting speed. Proper stick-out is about 10 times the wire diameter.
  • Position of welding wire: Affects weld bead shape and penetration. Traveling angle (angle between wire axis and center line of weld bead) and working angle (angle between wire axis and vertical line of center line of weld bead) are important.
  • Gas flow: Nozzle diameter (e.g., 12mm) and gas flow (8-15L/min) are critical.
  • Arc igniting: Gas shielded arc welding uses contact-short arc ignition. Adjust stick-out, keep wire end 2-3mm from workpiece.
  • Welding: Refer to MMA welding for general process (positioning, weld bead initiating, electrode manipulation, weld bead connection, weld bead ending).
  • Arc extinguishing: Do not extinguish immediately. Keep torch at crater briefly, then slowly raise to fill crater and protect molten pool.
  • Weld bead connection: Generally uses backward welding, similar to MMA.
  • Forehand welding and backhand welding: GMAW generally uses forehand welding.

8.3 Welding Operation in Different Positions

  • Flat position welding: Usually forehand welding with a traveling angle of 10°-15°. Straight moving electrode manipulation for sheet metal and backing welding; transverse swing for groove filling.
  • Welding of T-shaped joints and lap joints: Control torch angle based on plate thickness and fillet weld size to avoid defects. For horizontal fillet welding of different thickness plates, incline arc towards the thicker plate for even heating.
  • Vertical position welding: Upward or downward. Upward welding may cause melting metal to drop due to gravity. Downward welding is seldom used due to deep penetration and narrow weld bead.
  • Horizontal position welding: Parameters are similar to vertical position welding, but welding current can be slightly higher.

9. Maintenance

WARNING: The following operation requires sufficient professional knowledge on electric aspects and comprehensive safety knowledge. Operators should be holders of valid qualification certificates. Make sure the input cable of the machine is disconnected from the electricity utility before uncovering the welding machine.

  1. Check periodically whether inner circuit connection is in good condition, and if connectors are fastened. Tighten loose connections. If there is rust or oxidization, remove it with sandpaper and reconnect tightly.
  2. Do not let hands, hair, or other tools contact live parts when the machine is powered on (e.g., fan), to avoid injury or machine damage.
  3. Clean dust periodically with dry compressed air at a proper level to avoid damaging small parts inside the machine. If the welding environment has heavy smoke and pollution, the machine should be cleaned every day.
  4. Avoid water or vapor entering the machine. If it happens, dry the internal structure. Use a mega-meter to test the machine's insulation (wire to wire and wire to machine enclosure connection). Welding can be continued only after confirming normal insulation.
  5. Check periodically whether the insulation cover of all cables is in good condition. If there is any dilapidation, rewrap or replace it.
  6. Store the machine in its original packing in a dry location if it is not to be used for a long time.

10. Troubleshooting

WARNING: The following operation requires sufficient professional knowledge on electric aspects and comprehensive safety knowledge. Operators should be holders of valid qualification certificates. Make sure the input cable of the machine is disconnected from the electricity utility before uncovering the welding machine.

10.1 Common Failure Analysis and Troubleshooting

FailureCauseSolution
Machine does not turn on, no current
  • Power is not well connected
  • Welder fails
  • Reconnect power
  • Ask professional personnel for help
Fan does not work during welding
  • Fan power cord is not well connected
  • Auxiliary power supply fails
  • Reconnect fan power cord
  • Ask professional personnel for help
Display "E01"Over-current protection for welderRestart the welder. If problem persists, contact maintenance personnel.
Display "E03"Short-circuit current protectionRestart the welder. If problem persists, contact maintenance personnel.
Display "E04"Power limitation protectionRestart the welder. If problem persists, contact maintenance personnel.
Display "E01" (Over-current for wire)Over-current protection for wireRestart the welder. If problem persists, contact maintenance personnel.
Display "E02"Overheat protectionIt gets to normal after cooling the welder.

10.2 GMAW (MIG/MAG) Failure and Troubleshooting

FailureCauseSolution
No response or error code after pressing torch trigger
  • Torch is not well connected to wire feeder
  • Torch trigger fails
  • Reconnect torch and wire feeder
  • Repair or replace the torch
Gas output and wire feeding after pressing torch trigger but no current output and error code
  • Ground wire is not well connected to workpiece
  • Wire feeding unit or torch fails
  • Reconnect ground wire and workpiece
  • Repair the wire feeding unit or torch
Gas supply and current output but no wire feeding after pressing torch trigger
  • Wire feeding unit is stuck
  • Wire feeder fails
  • Control board in the welder fails
  • Unblock the wire feeding unit
  • Repair the wire feeder
  • Ask professional personnel for help
Welding current is instable
  • Unsuitable moment adjustment for wire feeder
  • Wire feed rolls do not match welding wire
  • Contact tip is worn severely
  • Wire liner of torch is worn severely
  • Welding wire is of poor quality
  • Readjust moment of wire feeder
  • Select suitable wire feed rolls and welding wire
  • Replace the contact tip of torch
  • Replace the wire liner
  • Replace wire with one of better quality

11. User Tips

  • For optimal aluminum welding, ensure you use the correct graphene tube fitting and U-wheel for the wire feeder. This prevents wire tangling and ensures smooth feeding.
  • Always clean the workpiece thoroughly before welding to ensure good arc stability and weld quality.
  • When using the synergic MIG mode, the machine will automatically set parameters, but fine-tuning the inductance knob can further optimize your weld for specific applications.
  • Remember to check the wire diameter compatibility and use the appropriate drive roller for your welding wire to avoid feeding issues.
  • The cooling fan operates on demand, so it's normal for it not to run constantly. This helps prolong its service life.

12. Warranty and Support

HITBOX Electromechanical Welding Company provides a 12-month maintenance warranty. For any questions or concerns, please feel free to contact HITBOX for support. Professional maintenance agents are available in the European Union.

You can find more information and contact details on the official website: www.hitboxweld.com

For additional documentation, a user manual PDF is available: View User Manual (PDF)


Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.