1. Introduction
This manual provides detailed instructions for the ATORCH XH-CDC-MK Charging Control Module, designed for use with BW150/BW600 series electronic load testers. This module acts as a bridge and a switch component, connecting a charger and a battery to facilitate charging and cycling test functions. It is crucial to understand that this module is not a charger itself but a control unit that works in conjunction with a compatible charger and electronic load.
Attention: This charging control module is specifically suitable for BW600 series electronic load testers. Do not use it with other models. Please carefully verify compatibility before use.
2. Safety Information
Please read and understand all safety instructions before operating the device. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Ensure all connections are correct and secure before applying power.
- Do not exceed the maximum voltage (100V) or current (20A) ratings.
- This module is designed for use with constant current power supplies/chargers.
- Avoid connecting the wiring input and DC5.5 interface for testing simultaneously.
- The charger input includes positive and negative reverse connection protection. However, always ensure correct polarity. No current or indicator light will be present if connected in reverse.
- Keep the module away from moisture, heat, and flammable materials.
- Do not attempt to modify or disassemble the module.
3. Product Overview
The XH-CDC-MK Charging Control Module is a compact device designed to enhance the functionality of your BW600 series electronic load tester. It enables precise control over battery charging and discharge cycling processes.
3.1 Package Contents
- 1 x XH-CDC-MK BW600 Charging Control Module
3.2 Module Components


The module features:
- B+ / B- Terminals: For battery connection.
- Con+ / Con- Terminals: For charger connection.
- DC5.5 Interface: Alternative input for charger connection.
- Hot / Normal Switch: Functionality not explicitly detailed, but typically relates to operating modes or temperature protection.
- MBR200P1 Diode: A Schottky diode, likely for reverse polarity protection or rectification.
4. Specifications
| Parameter | Value |
|---|---|
| Model Number | XH-CDC-MK |
| Brand Name | ATORCH |
| Type | DC Charging Control Module |
| DIY Supplies | Electrical |
| Maximum Switch Voltage | 100V |
| Maximum Switch Current | 20A |
| Certification | CE, RoHS |
| Origin | Mainland China |
5. Setup Instructions
Proper connection of the XH-CDC-MK module is essential for safe and effective operation with your BW600 series electronic load tester.
5.1 Required Equipment
- ATORCH BW600 series electronic load tester (sold separately)
- Compatible constant current charger/power supply
- Battery to be tested
- Appropriate wiring (if not using DC5.5 interface)
5.2 Connection Diagram

5.3 Wiring Steps
- Connect the Battery: Connect the positive terminal of your battery to the B+ terminal on the module and the negative terminal of your battery to the B- terminal on the module.
- Connect the Charger: You have two options for connecting your constant current charger:
- Wiring Method: Connect the positive output of your charger to the Con+ terminal on the module and the negative output of your charger to the Con- terminal on the module.
- DC5.5 Interface: Plug your charger's DC5.5 output into the corresponding DC5.5 input port on the module.
Important: Do NOT connect both the wiring method and the DC5.5 interface simultaneously for testing.
- Connect to BW600 Electronic Load Tester: The module integrates with the BW600 series electronic load tester. Ensure your BW600 tester is properly connected to the battery and configured for the desired test. The charging control module acts as an intermediary switch.
- Verify Polarity: The charger input has reverse connection protection. If the charger is connected in reverse, there will be no current flow or indicator light. Always double-check polarity before powering on.
- Set Charger Current: The charging current is controlled by setting the constant current source size of your charger. This control module does NOT adjust the charging current.
6. Operating Instructions
The XH-CDC-MK module enables charging and cycling test functions when used with a BW600 series electronic load tester.
- Power On: Once all connections are secure, power on your constant current charger and the BW600 electronic load tester.
- Module Function: The module's primary function is to implement charging and cycling charging test functions. It acts as a switch to control the flow of current from the charger to the battery during charging phases, and allows the BW600 to discharge the battery during discharge phases.
- BW600 Configuration: Configure your BW600 electronic load tester for the desired charging or cycling test. The BW600 will manage the overall test sequence, utilizing the XH-CDC-MK module to switch between charging and discharging as needed.
- Monitoring: Monitor the charging/discharging process and battery parameters through the BW600 electronic load tester's display. The module itself does not have a display.
- Hot / Normal Switch: The function of the 'Hot / Normal' switch should be determined by the specific requirements of your test and the capabilities of your BW600 tester. Refer to your BW600 manual for details if this switch affects its operation.
7. Maintenance
- Keep the module clean and free from dust and debris.
- Store in a dry environment when not in use.
- Regularly check all connections for tightness and signs of wear.
- Do not expose the module to extreme temperatures or humidity.
8. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| No current/indicator light when charger connected | Reverse polarity connection of charger. | Check and correct the charger's positive and negative connections to Con+ and Con- (or DC5.5). |
| Module not functioning with BW600 | Incorrect wiring; module not compatible with tester; BW600 not configured correctly. | Verify all connections according to Section 5. Ensure your BW600 is a compatible series. Check BW600 manual for proper test setup. |
| Unexpected charging behavior | Charger current not set correctly; faulty charger; module malfunction. | Ensure your constant current charger is set to the desired current. Test the charger independently. If issues persist, contact support. |
| Module overheating | Exceeding maximum current/voltage; poor ventilation. | Ensure operation within 100V/20A limits. Provide adequate ventilation around the module. |
9. User Tips
- Understand its Role: Remember, this is a control module, not a standalone charger. It requires a separate constant current charger and a BW600 series electronic load tester to function.
- Verify Compatibility: Always double-check that your electronic load tester is a BW600 series model to ensure proper functionality.
- Wiring Clarity: If you're unsure about the wiring, refer to the provided diagrams and notes carefully. Incorrect connections can prevent operation or damage components.
- Charger Settings: The charging current is determined by your external constant current charger. This module does not regulate the current, so ensure your charger is set appropriately for your battery.
10. Warranty and Support
ATORCH products are manufactured to high-quality standards. For any technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact your retailer or the ATORCH customer support directly. Please have your product model number (XH-CDC-MK) and purchase information ready when contacting support.