1. Introduction
The PUSR M100-ETH is an intelligent IoT I/O gateway designed for industrial data acquisition and edge computing applications. It features on-board I/O support and versatile communication interfaces including RS-485, RS-232, and Ethernet. This advanced modular RTU product simplifies deployment and maintenance through its unique hardware and software design.
The M100-ETH supports the Modbus RTU Master protocol for retrieving serial data from field devices and offers OT/IT protocol conversion. It can convert collected I/O and serial data into formats suitable for various upper-level software, such as cloud services via MQTT, SCADA systems via Modbus TCP, and web servers via HTTP. This integrated design reduces system complexity, network topology space requirements, and overall installation time. It also allows for connecting legacy devices to Ethernet, extending their operational lifetime.
2. Setup
2.1 Package Contents
Please verify that all items are present and in good condition:
- PUSR M100-ETH Gateway unit
- Power adapter (if included)
- Documentation (this manual)
2.2 Physical Installation
The M100-ETH supports both DIN-rail and panel mounting for flexible installation in industrial environments.
- DIN-rail Mounting: Attach the device to a standard 35mm DIN-rail using the integrated clips. Ensure the clips are securely engaged.
- Panel Mounting: Use the designated clip positioning holes to secure the device to a panel.
2.3 Power Connection
Connect a DC power source (9-36V) to the DC 9-36V Power Supply terminal on the device. The device features reverse polarity protection and surge protection for enhanced reliability.
2.4 Interface Connections
Refer to the diagram below for port locations and connect your devices accordingly:
- Ethernet Port (WAN): Connect to your network using a standard Ethernet cable. Supports 10/100 Mbps with auto MDI/MDIX.
- Serial Port: Connect Modbus RTU devices via the RS-485/232 serial interface.
- Digital Inputs (DI): Connect digital sensors or switches. Supports 2 non-isolated inputs (0-2V logic low, 9-36V logic high).
- Digital Outputs (DO): Connect relays or actuators. Features 2 relays (DC 10A/28V, AC 10A/277V NO, AC 5A/250V NC).
- Analog Inputs (AI): Connect analog sensors. Supports 2 analog inputs (4-20mA).
2.5 Initial Configuration
The M100-ETH can be configured using a Windows Utility or via a web console (HTTP). Please refer to the separate software guide for detailed instructions on using these tools to set up network parameters, Modbus polling, and other functionalities.
3. Operating Instructions
3.1 Modbus Gateway Functionality
The M100-ETH acts as a Modbus Gateway, supporting multi-host polling and Modbus protocol conversion. It can retrieve data from Modbus RTU slave devices and convert it to Modbus TCP or custom JSON formats for cloud servers.
3.2 Edge Computing and Protocol Conversion
The gateway performs edge computing functions including data acquisition, periodic reporting, computation/linkage, and on-change reporting. It supports various network protocols like ICMP, IPv4, ARP, TCP, UDP, DHCP, DNS, HTTPS, MQTT, SNMP, Telnet, NTP, and SSL v3.
Supported IoT platforms include Alibaba Cloud, AWS IoT, PUSR Cloud, Microsoft Azure, and ThingsBoard. The standard MQTT protocol is supported with 16 subscription and 16 publish topics, allowing for custom topics and JSON formats.
3.3 Linkage Control
The M100-ETH supports linkage control, where data collection points, Digital Inputs (DI), and Analog Inputs (AI) can be used as triggers to execute actions on Digital Outputs (DO). This enables automated responses based on monitored conditions.
3.4 Modular IO Expansion
The M100-ETH features a creative modular design, allowing users to extend IO capabilities by adding compatible IO Modules as needed. This provides simple, efficient, and cost-saving scalability.
3.5 Offline Data Recording (M100s Series Only)
Please note that the offline data recording feature on an SD card, where data is cached during internet disconnection and sent to the server upon reconnection, is supported only by the USR-M100s series models, not the M100-ETH model.
4. Maintenance
To ensure optimal performance and longevity of your PUSR M100-ETH Gateway, follow these maintenance guidelines:
- Cleaning: Keep the device clean and free from dust and debris. Use a soft, dry cloth for cleaning. Avoid using liquid cleaners or solvents.
- Connection Checks: Periodically inspect all cable connections (power, Ethernet, serial, I/O) to ensure they are secure and free from damage.
- Firmware Updates: Check the official PUSR website for available firmware updates. Keeping the firmware up-to-date can provide new features, performance improvements, and security enhancements. Follow the provided instructions carefully when performing updates.
- Environmental Conditions: Ensure the device operates within its specified environmental conditions (temperature, humidity) to prevent damage.
5. Troubleshooting
If you encounter issues with your PUSR M100-ETH Gateway, consider the following troubleshooting steps:
- No Power:
- Verify the power supply is correctly connected and providing 9-36V DC.
- Check the power indicator LED on the device. If it's off, ensure the power source is active.
- Network Connectivity Issues:
- Ensure the Ethernet cable is securely connected to the WAN port and your network switch/router.
- Check the network indicator LEDs on the device and your network equipment.
- Verify IP settings (DHCP or Static IP) using the Windows Utility or web console.
- Modbus Communication Failure:
- Check serial port wiring (RS-485/232) for correct polarity and connections.
- Verify Modbus parameters (baud rate, data bits, stop bits, parity, flow control) match the connected Modbus slave device.
- Ensure the Modbus slave device is powered on and functioning correctly.
- Review the Modbus polling configuration in the gateway's settings.
- I/O Functionality Problems:
- Check wiring for DI, DO, and AI connections.
- Verify sensor and actuator functionality independently.
- Review I/O configuration and linkage rules in the gateway's settings.
- Accessing Web Console:
- Ensure your computer is on the same network as the M100-ETH.
- Confirm the correct IP address of the gateway.
- Try clearing your browser's cache or using a different browser.
If problems persist after attempting these steps, please contact technical support.
6. Specifications
| Category | Parameter | Value |
|---|---|---|
| Power Supply | Input Voltage | 9 – 36 VDC, reverse polarity protection, surge protection |
| Power Consumption | Idle: < 2.4W, Max: < 4.8W | |
| Serial Communication | Baud rates | 600~230400 bps |
| Data bits | 7, 8 | |
| Stop bits | 1, 2 | |
| Parity | None, Even, Odd, Mark, Space | |
| Flow | None, XON/XOFF | |
| Physical Interface | DI (Digital Input) | 2 x Digital non-isolated input (0 - 2 V logic low, 9 - 36 V logic high) |
| DO (Digital Output) | 2 x Relays (DC 10A / 28V, AC 10A / 277V NO, AC 5A / 250V NC) | |
| AI (Analog Input) | 2 x Analog input 4-20mA | |
| Physical Specifications | Dimensions (W x H x D) | 79.6 x 58 x 110 (mm) |
| Mounting options | DIN rail, wall mounting | |
| Hardware Protection | ESD | IEC61000-4-2, Level 3, class B, contact 6KV, air 8KV |
| Surge | IEC61000-4-5, Level 3, class B | |
| EFT | IEC61000-4-4, Level 3, class B | |
| Network | ETHERNET | 1 x WAN port 10/100 Mbps, compliance IEEE 802.3, IEEE 802.3u standards, supports auto MDI/MDIX |
| Software | Network protocols | ICMP, IPv4, ARP, TCP, UDP, DHCP, DNS, HTTPS, MQTT, SNMP, Telnet, NTP, SSL v3 |
| IP | DHCP/StaticIP | |
| Websocket | Supported | |
| MQTT | Supported, standard MQTT protocol, 16 subscription topics and 16 publish topics | |
| Linkage control | Supported. Data collection points, DI, and AI can be used as trigger and executed by DO | |
| IOT PLATFORMS | Alibaba cloud, AWS IOT, PUSR cloud, Microsoft Azure, ThingsBoard | |
| User Configuring | Windows Utility, web console(HTTP) | |
| MODBUS RTU Master | Supported functions | 01, 02, 03, 04 |
| Supported data formats | 8 bit: INT, UINT; 16 bit: INT, UINT (MSB first); 32 bit: float, INT, UINT (ABCD (big-endian), DCBA (little-endian), CDAB); 64bit: float | |
| Supported data points | 128 | |
| Approvals | Regulatory | CCC, CE/RED*, RoHS* |
7. User Tips
- Leverage Modularity: If you require more I/O points, consider expanding your M100-ETH gateway with PUSR IO Extender modules. This allows for flexible and scalable solutions without replacing the entire system.
- Seamless Integration: The M100-ETH is designed for seamless integration, providing full control and monitoring over your connected devices. Take advantage of its protocol conversion capabilities to unify your industrial data.
- Extend Legacy Equipment Life: Utilize the gateway to connect older, legacy devices to modern Ethernet-based systems. This allows you to continue using existing equipment while benefiting from IoT connectivity.
- Cloud Connectivity: Explore the various supported IoT cloud platforms (Alibaba Cloud, AWS IoT, Microsoft Azure, ThingsBoard, PUSR Cloud) to centralize data monitoring and control for your applications.
8. Warranty and Support
8.1 Warranty Information
The PUSR M100-ETH Industrial Remote Edge Computing IoT IO Gateway comes with a 2-year warranty from the date of purchase, covering manufacturing defects and malfunctions under normal operating conditions.
8.2 Technical Support
For technical assistance, troubleshooting, or any inquiries regarding your PUSR M100-ETH Gateway, please contact our support team:
- WhatsApp/WeChat: +86 18174450433 (Aben)
- Email: 3507954720@qq.com
When contacting support, please provide your product model (M100-ETH) and a detailed description of the issue you are experiencing.