TBK 2208

Contents

TBK 2208 X-RAY Chip Fluoroscopy Instrument User Manual

Model: TBK 2208

Brand: TBK

1. Introduction

The TBK 2208 X-RAY Chip Fluoroscopy Instrument is an advanced diagnostic tool designed for rapid and non-destructive inspection of mobile phone PCBs and motherboards. This instrument utilizes X-ray technology to provide clear internal imaging, allowing for direct observation of solder joints, chips, and circuitry without the need for disassembly. It is equipped with a high-definition intelligent software system for efficient operation and features robust safety measures to protect users from radiation.

2. Features

  • Intelligent X-RAY Motherboard Tester
  • Built-in high-density lead-shielded safety chamber
  • High-definition intelligent software system
  • One-click sampling for rapid detection
  • Double security mechanism (stops operation and warns if door opens during use)
  • No disassembly required for inspection
  • Clear internal motherboard circuitry visualization
  • Direct observation of solder joints
  • Easy inspection of motherboards, chips, etc.
  • Wide range of applications
  • Fast repair speed

3. Setup

Follow these steps to set up your TBK 2208 instrument:

  1. Unpack: Carefully unpack the TBK 2208 instrument and all accessories from its wooden crate packaging.
  2. Placement: Place the unit on a stable, level, and sturdy surface in a well-ventilated area.
  3. Power Connection: Connect the provided power cord to the instrument's power input and then to a suitable electrical outlet. Ensure the voltage matches your instrument's requirement (110V or 220V).
  4. Computer Connection: Connect a computer to the instrument via the USB port for software interface and high-definition image display.
  5. Accessory Connection: Connect the provided mouse to the instrument for easier navigation and control.
Diagram showing the front panel of the TBK 2208 X-RAY instrument with labels for USB, Computer connection, High-definition images, Emergency stop, Buzzer, Power on, Photograph button, and Work Pod. Dimensions are 240mm width and 415mm height.
Figure 1: TBK 2208 Product Information and Front Panel Layout
Image showing the TBK 2208 X-RAY instrument from a side angle, highlighting the USB and computer connection ports.
Figure 2: Side view of TBK 2208 showing connectivity ports

4. Operating Instructions

To operate the TBK 2208 X-RAY instrument:

  1. Power On: Press the 'Power on' button located on the front panel to start the instrument.
  2. Place Object: Open the work pod door and carefully place the mobile phone PCB or motherboard onto the inspection platform within the work pod. Ensure the object is stable and positioned correctly for imaging. Close the door securely.
  3. Software Interface: Ensure the instrument is connected to a computer via USB and the dedicated X-ray software is running. High-definition images of the internal components will be displayed on the connected computer screen.
  4. Adjust and Focus: Use the software interface to adjust X-ray parameters such as exposure time, intensity, and focus to achieve the clearest image.
  5. Capture Image: Press the 'Take photos' button on the front panel or use the software control to capture a still image of the current X-ray view.
  6. Emergency Stop: In case of any malfunction, unusual noise, or emergency, immediately press the large red 'Emergency stop' button on the front panel to cut power to the X-ray emission.
  7. Buzzer Feedback: The buzzer will sound to indicate warnings or provide operational feedback. Refer to the software for specific alerts.
Front view of the TBK 2208 X-RAY instrument showing the display screen with a PCB image, emergency stop button, buzzer, power on button, and take photos button.
Figure 3: Front view of the TBK 2208 in operation

5. Safety Information

The TBK 2208 X-RAY instrument is designed with user safety as a priority. It incorporates a high-density lead-shielded safety chamber to prevent radiation leakage. Adhere to the following safety guidelines:

  • Radiation Shielding: The instrument features a built-in high-density lead-shielded safety chamber. Do not attempt to modify or remove any part of this shielding.
  • Double Security Feature: If the work pod door is accidentally opened while the X-ray is active, the instrument will automatically stop operation and issue an audible warning to protect the user from radiation exposure. Always ensure the work pod door is securely closed before initiating X-ray exposure.
  • Authorized Use Only: This device should only be operated by trained and authorized personnel.
  • Ventilation: Operate the device in a well-ventilated area.
  • No Bypassing Safety: Never attempt to bypass any safety features or interlocks.
  • Maintenance: Only qualified service personnel should perform internal maintenance or repairs.

6. Maintenance

Proper maintenance ensures the longevity and optimal performance of your TBK 2208 instrument:

  • Cleaning: Regularly clean the exterior surfaces of the instrument with a soft, dry, lint-free cloth. Avoid using abrasive cleaners, solvents, or harsh chemicals, as these can damage the finish or internal components.
  • Software Updates: Keep the operating software updated to the latest version. Check the manufacturer's website or contact support for available updates.
  • Cable Inspection: Periodically inspect the power cord, USB cables, and any other connected cables for signs of wear, cuts, or damage. Replace damaged cables immediately.
  • Work Pod Cleanliness: Keep the interior of the work pod clean and free of dust or debris that could interfere with imaging.
  • Professional Service: For any internal maintenance, calibration, or repairs, contact your authorized dealer or the manufacturer's service department. Do not attempt to open the instrument casing yourself.

7. Troubleshooting

If you encounter issues with your TBK 2208, refer to the following common troubleshooting steps:

ProblemPossible CauseSolution
Instrument does not power onPower cord disconnected; Power switch off; Faulty power outletCheck power cord connections; Ensure power switch is ON; Test power outlet with another device
No image displayed on computerUSB cable disconnected; Software not running; Instrument not powered on; X-ray not activatedVerify USB connection; Launch X-ray software; Power on instrument; Activate X-ray exposure via software
Buzzer alarm sounds during operationWork pod door open; Safety interlock triggeredEnsure work pod door is securely closed; Check software for specific error messages
Poor image qualityIncorrect X-ray parameters; Object not positioned correctly; Software settingsAdjust exposure, intensity, and focus in software; Reposition object; Check software image enhancement settings

If the problem persists after attempting these solutions, please contact technical support.

8. Specifications

AttributeValue
ModelTBK 2208
Voltage110V-220V
Exposure Power100W
Standby Power60W
Resolution688*834px
Pixel Diameter35μm
Detector Area25*35mm
X-ray Tube Voltage60kV
X-ray Tube Current0.8mA
Product Dimensions240*240*415mm
Net Weight12.5KG
Packaging Dimensions350*350*560mm
Packaging Weight23KG
MaterialStainless steel
DIY SuppliesPhone Repair

9. User Tips

  • For best results, ensure the object being inspected is clean and free of debris.
  • Utilize the high-definition imaging capabilities to zoom in on specific areas for detailed inspection of solder joints and micro-components.
  • Always follow safety protocols, especially regarding the secure closure of the work pod door before initiating X-ray exposure.
  • Regularly save your captured images and diagnostic data to your connected computer.

10. Packaging Information

The TBK 2208 instrument is shipped in a robust wooden crate for protection. The package typically includes the following items:

  • TBK 2208 X-RAY Chip Fluoroscopy Instrument
  • Power Cord
  • Mouse
Image showing the contents of the product packaging: a wooden crate, the TBK 2208 product, a power cord, and a mouse.
Figure 4: TBK 2208 Packaging Contents

11. Warranty & Support

For warranty information, technical support, or service inquiries, please contact your authorized dealer or the manufacturer directly. Keep your purchase receipt and product model number (TBK 2208) handy for faster assistance. Do not attempt to repair the unit yourself, as this may void your warranty and pose safety risks.


Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.