DATOUBOSS DT-1218M

Contents

DATOUBOSS 12V 1800W Hybrid Solar Inverter

Model: DT-1218M

1. Introduction

The DATOUBOSS DT-1218M Hybrid Solar Inverter is an all-in-one solution designed to integrate solar power generation, battery storage, grid supply, and backup power into a single, compact unit. This system aims to make your home energy simpler, more efficient, and reliable, providing uninterrupted power for various applications.

Key Features:

  • 3 smart modes: Grid / PV / Battery supply for uninterrupted power.
  • High-efficiency MPPT with a wide tracking range of 30–240V for optimal solar energy utilization.
  • Pure sine wave output, ensuring safe operation for all types of home appliances.
  • Supports battery-less mode for flexible installation options.
  • Wide AC input range of 120–280V, providing stable operation even in weak grid areas.
  • User-friendly LCD+LED display for easy monitoring and operation.
  • Comprehensive protection features: Overvoltage Protection (OVP), Undervoltage Protection (UVP), Overload Protection (OLP), Short Circuit Protection (SCP), Overtemperature Protection (OTP), and Anti-islanding.
  • Wall-mounted design, compact, quiet, and durable.

Ideal Applications:

  • Residential solar & energy storage systems
  • Villas, rural homes, homestays
  • Small shops, farms, monitoring stations
  • Off-grid areas: RVs, camping, islands
  • Backup power for blackout-prone regions

Package Includes:

  • 1 × 1800W 12V Hybrid Inverter (Model DT-1218M)
  • 1 × User Manual

2. Safety Information

Please read and understand all safety instructions before installing, operating, or maintaining the inverter. Failure to follow these instructions may result in electric shock, fire, severe injury, or death.

General Safety Precautions:

  • Only qualified personnel should install or maintain this device.
  • Do not disassemble the inverter. There are no user-serviceable parts inside.
  • Ensure the inverter is installed in a well-ventilated area, away from flammable materials, moisture, and direct sunlight.
  • Keep children and unauthorized persons away from the inverter.
  • Wear appropriate personal protective equipment (PPE), including insulated gloves and safety glasses, when working with the inverter or batteries.
  • Ensure all wiring is correctly sized and properly insulated according to local electrical codes.

Electrical Safety:

  • Before any wiring or maintenance, disconnect all power sources: AC input, PV input, and battery. Verify zero voltage with a multimeter.
  • Ensure proper grounding of the inverter.
  • Do not connect the inverter to a power source that exceeds its rated voltage.
  • Avoid touching uninsulated wires or terminals.
  • In case of fire, use a CO2 or chemical powder extinguisher. Do not use water.

Battery Safety:

  • Batteries can produce explosive gases. Ensure adequate ventilation.
  • Do not smoke or allow sparks or flames near batteries.
  • Use only recommended battery types and sizes.
  • Connect batteries with correct polarity. Reverse polarity can cause severe damage.

3. Product Overview

The DATOUBOSS DT-1218M Hybrid Solar Inverter is designed for ease of use and robust performance. Below is an overview of its components and features.

Inverter Components and Interfaces:

Detailed specifications showing the inverter's interfaces
Figure 3.1: Inverter Interfaces (Right, Left, Front, Bottom)
  • Front Panel: LCD display for status monitoring, LED indicators, and a function key control area for settings adjustment.
  • Left Side: Power on/off switch.
  • Right Side: RS485-1 communication interface (for external communication/WIFD) and RS485-2 communication interface (for BMS communication).
  • Bottom Interface: Cooling fans, Battery terminal port, PV input terminal port, Earth wire terminal, AC input (on-grid) terminal, AC output terminal.

Protection Functions:

Diagram illustrating multiple protection functions of the inverter
Figure 3.2: Multiple Protection Functions

The inverter is equipped with multiple protection mechanisms to ensure safety and longevity:

  • Overvoltage Protection
  • Temperature Protection
  • Undervoltage Protection
  • Short Circuit Protection
  • Overcharge Protection
  • Overload Protection
  • Over-discharge Protection
  • Overcurrent Protection
  • Anti-islanding Protection

4. Specifications

Detailed technical specifications for the DATOUBOSS DT-1218M Hybrid Solar Inverter.

Detailed parameters of the 12V 1800W Solar Inverter
Figure 4.1: Detailed Product Parameters
ParameterValue
Model NumberDT-1218M
Rated Power1800W
Output TypeSINGLE
Output Frequency50/60Hz
Output Voltage220V-240V
Battery Voltage12VDC
DC Input Current166.6A
Max AC Charging Current65A
Max PV Charging Current100A
Max PV Input Power2500W
Max PV Input Voltage (Voc)300VDC
MPPT Tracking Range30-240VDC
Transfer Time10ms (typical)
Protection ClassIP20
Noise Level≤50dB
SupportsBattery-Free Mode
Size (L*W*H)31.00 x 25.00 x 9.10 cm (12.2 x 9.8 x 3.58 inches)
Weight4kg
Operating Temperature-10°C to 50°C
Storage Temperature-15°C to 60°C
Humidity0-95% (No condensation)
Elevation2000m (More than derating)
CommunicationRS485 / Mobile APP/WiFi Monitoring (Optional)
InstallationWall-Mounted

5. Installation and Setup

Proper installation is crucial for the safe and efficient operation of your hybrid solar inverter. Follow these steps carefully.

5.1 Physical Installation:

  • Mounting Location: Choose a wall-mounted location that is dry, well-ventilated, and protected from direct sunlight, rain, and dust. Ensure sufficient clearance around the inverter for proper airflow and cooling.
  • Mounting: Securely mount the inverter to a sturdy wall using appropriate screws and anchors. The inverter weighs approximately 4kg, so ensure the mounting surface can support its weight.

5.2 Wiring Connections:

Refer to the wiring diagram below for correct connections. All wiring must be performed by a qualified electrician and comply with local electrical codes.

Wiring and Technical Specifications diagram for the hybrid solar inverter
Figure 5.1: Inverter Wiring Diagram
  • Earth Wire: Connect the inverter's earth terminal to a reliable ground point.
  • Battery Connection (12V-BATTERIE):
    • Connect the 12V battery bank to the battery terminal port on the inverter.
    • Ensure correct polarity (+ to + and - to -).
    • Rated Battery Voltage: 12VDC. Battery Voltage Range: 10.5-15VDC (default).
    • Max PV Charging Current: 100A. Max AC Charging Current: 65A.
  • PV Input Connection (SOLAR SYSTEM):
    • Connect your solar panel array to the PV input terminal port.
    • Max PV Input Power: 2500W.
    • MPPT Tracking Voltage Range: 30VDC-240VDC.
    • Rated Voltage: 180VDC. Max PV Input Voltage Voc: 300VDC.
    • Max PV Input Current: 15A. MPPT Tracking Channels: 1.
  • AC Input Connection (POWER GRID):
    • Connect the utility grid power to the AC input (on-grid) terminal.
    • Battery Type: 220V/230V/240V.
    • Rated Battery Voltage: 165VAC-280VAC / 120VAC-280VAC (Can be set).
    • Battery Voltage Range: 50Hz/60Hz.
  • AC Output Connection (AC OUTPUT):
    • Connect your household loads to the AC output terminal.
    • Rated Output Power: 1800W.
    • Rated Output Voltage: 220V/230V/240VAC ±2%.
    • Rated Input Frequency: 50Hz/60Hz. Output Frequency Accuracy: ±1%.
    • Output Wave: Pure Sine Wave.

5.3 Battery Compatibility:

Diagram showing compatibility with multiple battery types
Figure 5.2: Compatible Battery Types

The inverter is compatible with various battery types, and a Battery Management System (BMS) is integrated to monitor battery status and prevent overcharging and under-discharging, extending battery life. Users can configure the battery type via the LCD display. Compatible types include:

  • GSL (Gel Sealed Lead-Acid Battery)
  • LN (Lithium-Ion Battery)
  • FLB (Flooded Lead-Acid Battery)
  • LiFePO4 (Lithium Iron Phosphate Battery)
  • SLA (Sealed Lead-Acid Battery)
  • USER (User-defined)

5.4 Initial Power-Up:

  • After all connections are secure and verified, switch on the battery breaker first.
  • Then, switch on the PV array breaker (if applicable).
  • Finally, switch on the AC input breaker (if applicable) and then the inverter's power on/off switch.
  • Observe the LCD display for status and any error messages.

6. Operation

The inverter features an intuitive LCD display and function keys for easy control and monitoring.

6.1 LCD Display and Function Keys:

The front panel includes an LCD display that shows real-time system status, input/output voltages, battery charge, and operational modes. LED indicators provide quick visual status. Function keys allow navigation through menus and adjustment of settings.

6.2 Charging Modes:

Diagram illustrating multiple charging and output modes
Figure 6.1: Multiple Charging and Output Modes

The inverter supports four charging modes:

  • AC Power First: If mains power is available, the battery is charged using AC power.
  • Solar Priority: Charging with solar energy priority. If no solar power is available, the battery is charged via the power grid.
  • Mixed Loading: Solar and mains power can charge the battery at the same time.
  • Solar Only: The battery can only be charged using solar energy.

6.3 Output Working Modes:

The inverter offers three output working modes:

  • Solar Priority: Prioritizes solar power for loads.
  • Utility Priority: Prioritizes utility grid power for loads.
  • SBU Mode: Solar-Battery-Utility mode, prioritizing solar, then battery, then utility.

6.4 Battery-Free Mode:

The inverter supports operation without a connected battery. In this mode, the inverter can directly power loads from solar panels or the utility grid. This offers flexibility during installation or in scenarios where battery storage is not required.

7. Maintenance

Regular maintenance ensures the longevity and optimal performance of your inverter.

  • Cleaning: Periodically clean the exterior of the inverter with a dry, soft cloth. Ensure ventilation openings are free from dust and debris. Do not use liquid cleaners.
  • Connection Checks: Annually inspect all electrical connections (PV, battery, AC input/output, earth) for tightness and signs of corrosion. Tighten any loose connections.
  • Environmental Check: Ensure the installation environment remains within specified temperature and humidity ranges.
  • Firmware Updates: If optional communication modules (RS485, WiFi) are used, check the manufacturer's website for any available firmware updates.
  • Battery Inspection: If using lead-acid batteries, check electrolyte levels and terminal conditions as per battery manufacturer guidelines.

8. Troubleshooting

This section provides guidance on common issues you might encounter with your inverter. For problems not listed here, contact customer support.

ProblemPossible CauseSolution
Inverter not turning onNo power from battery/PV/AC grid; Loose connections; Inverter switch off.Check all power sources and connections. Ensure the inverter's power switch is ON.
No AC outputOverload; Short circuit; Low battery voltage; High temperature.Reduce load. Check for short circuits. Charge battery. Allow inverter to cool down.
Battery not chargingPV input too low/high; AC input unavailable; Incorrect charging mode; Battery fault.Check PV voltage/current. Verify AC grid connection. Select appropriate charging mode. Check battery health.
Overload Protection (OLP) triggeredConnected load exceeds inverter's rated power.Disconnect some loads. Restart the inverter.
High Temperature Protection (OTP) triggeredInverter overheating due to poor ventilation or high ambient temperature.Ensure adequate ventilation. Clean fan vents. Reduce ambient temperature if possible.
Error message on LCDSpecific fault detected by the inverter.Refer to the inverter's display for the specific error code and consult the full manual (if available) or contact support.

9. User Tips

  • Optimize Solar Panel Placement: Ensure your solar panels are positioned for maximum sun exposure throughout the day to get the most out of your MPPT charge controller.
  • Monitor Load: Keep an eye on the total power consumption of your appliances to avoid overloading the inverter, especially when running high-wattage devices like electric kettles or microwaves.
  • Battery Management: If using batteries, regularly check their health and ensure they are compatible with the inverter's settings for optimal performance and lifespan.
  • Ventilation is Key: Always ensure the inverter has ample space around it for air circulation. Overheating can reduce efficiency and lifespan.

10. Warranty and Support

For warranty information, please refer to the documentation provided at the time of purchase or contact your seller directly. Keep your purchase receipt as proof of purchase.

For technical support, troubleshooting assistance beyond this manual, or inquiries about spare parts, please contact DATOUBOSS customer service or your authorized dealer. Provide your product model (DT-1218M) and serial number (if available) for faster service.

© 2023 DATOUBOSS. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.