1. Introduction
The JIKONG Lithium Battery Intelligent Protection Board (BMS) is a management system designed for large capacity series lithium battery packs. It features voltage acquisition, high current active balancing, overcharge/over-temperature protection, coulomb meter, Bluetooth communication, and host computer monitoring. It supports lithium iron phosphate and ternary lithium battery types.
The board utilizes energy transfer active balancing technology to achieve a continuous 1A/2A balance current, ensuring battery consistency, extending range, and delaying aging. It comes with a mobile APP (Android/iOS) for checking battery status, modifying parameters, and controlling charge/discharge switches. Its compact size and comprehensive functions make it suitable for high-power energy storage, base station backup power, and solar power systems.
2. Key Features
- LED Bluetooth status indicator
- APP Bluetooth remote operation
- Battery capacity calculation
- Supports PC operations
- High precision voltage acquisition (±3mV)
- High precision current acquisition
- Support information screen display
- Accurate time logging
- RS485 communication support
- CAN communication support
- Heating function support
- Alarm dry contact function
- Charge overcurrent protection
- Charge overvoltage protection
- Charge over temperature protection
- Low temperature protection during charge
- Discharge overcurrent protection
- Discharge undervoltage protection
- Discharge over temperature protection
- Short circuit protection
- Battery parallel current limiting function
3. Specifications
3.1. Basic Parameters
| Parameter | Value | Unit |
|---|---|---|
| Supply Voltage | 20-70 | V |
| Standby Power Consumption | 12 | mW |
| Operating Power Consumption | 1100 | mW |
| Operating Temperature | -30-70 | °C |
| Maximum Number of Collection Strings | 16 | S |
| Maximum Balancing Current | 1-2 | A |
| Maximum Charging Current (10P) | 100 | A |
| Maximum Charging Current (15P) | 150 | A |
| Maximum Charging Current (20P) | 200 | A |
| Maximum Discharge Current (10P) | 100 | A |
| Maximum Discharge Current (15P) | 150 | A |
| Maximum Discharge Current (20P) | 200 | A |
| Maximum Instantaneous Current (10P) | 200 | A |
| Maximum Instantaneous Current (15P) | 300 | A |
| Maximum Instantaneous Current (20P) | 400 | A |
| Maximum Internal Loop Resistance (10P) | 1 | mΩ |
| Maximum Internal Loop Resistance (15P) | 0.45 | mΩ |
| Maximum Internal Loop Resistance (20P) | 0.35 | mΩ |
| Protective Plate Size | 300*100*24 | mm |
| Finished Weight | 1000 | g |
3.2. Default Parameters
| Parameter | Li-ion (Default) | LiFePO4 (Default) | LTO (Default) | Unit |
|---|---|---|---|---|
| Balancing Initial Voltage | 3 | 3 | 2 | V |
| Maximum Balancing Current | 1-2 | 1-2 | 1-2 | A |
| Unit Overcharge Voltage | 4.2 | 3.6 | 2.7 | V |
| Single Overcharge Protection Recovery | 4.17 | 3.54 | 2.64 | V |
| Monomer Undervoltage Protection | 2.82 | 2.6 | 1.8 | V |
| Single Undervoltage Protection Recovery | 2.85 | 2.65 | 1.85 | V |
| Automatic Shutdown Voltage | 2.8 | 2.5 | 1.7 | V |
| SOC-0% Voltage | 2.9 | 2.6 | 1.85 | V |
| SOC-100% Voltage | 4.18 | 3.5 | 2.65 | V |
| Trigger Balancing Differential Pressure | 0.01 | 0.01 | 0.01 | V |
| Charging Overcurrent Protection Delay | 3 | 3 | 3 | S |
| Charging Overcurrent Protection Release Time | 60 | 60 | 60 | S |
| Discharge Overcurrent Protection Delay | 300 | 300 | 300 | S |
| Discharge Overcurrent Protection Release Time | 60 | 60 | 60 | S |
| Short-circuit Protection Delay | 5 | 5 | 5 | µS |
| Short-circuit Protection Release Time | 30 | 30 | 30 | S |
| Charging Overtemperature Protection Temperature | 70 | 70 | 70 | °C |
| Charge Overtemperature Restore Temperature | 60 | 60 | 60 | °C |
| Discharge Overtemperature Protection Temperature | 70 | 70 | 70 | °C |
| Discharge Overtemperature Recovery Temperature | 60 | 60 | 60 | °C |
| Charging Low Temperature Protection Temperature | -20 | -20 | -20 | °C |
| Charge Low Temperature Restore Temperature | -10 | -10 | -10 | °C |
| MOS Overtemperature Protection Temperature | 100 | 100 | 100 | °C |
| MOS Overtemperature Protection Recovery Temperature | 80 | 80 | 80 | °C |
| Device Address | 0 | 0 | 0 | / |
3.3. Other Product Properties
- Certification: CE
- Balance Function: Active Balanced BMS
- Hardware or Smart: SMART BMS
- Charge and Discharge Port: Common Port BMS
- Type: LIFEPO4 Battery BMS
- Origin: Mainland China
- Function: Overcharge Protection, Over Discharge Protection, Overcurrent Protection, Short Circuit Protection
- Usage Scenario: Power BMS, Energy Storage BMS, 3C Digital BMS
- Charging Current: 10A
4. Product Overview
The JIKONG Communication Board is designed to work with specific PB Serial BMS models. Ensure compatibility before use.

4.1. Product Dimensions
The dimensions of the JIKONG PB1/2A16S-10/15/20P series protection board are 300mm × 100mm × 24mm.

4.2. Interface Board Diagram
The interface board includes various connectors, LEDs, and DIP switches for configuration and communication.


4.3. Connector Pin Definitions
| Connector | Pin No. | Pin Name | Definition |
|---|---|---|---|
| P1 (Interface Board) | Interface board interface | ||
| P4 (URAT Display Interface) | 1 | K- | Activation signal negative electrode |
| 2 | K+ | Activate the positive signal | |
| 3 | GND | Negative terminal | |
| 4 | RX | UART RX, 5V | |
| 5 | TX | UART TX, 5V | |
| 6 | VCC | Display power output | |
| P5 (Display Interface) | 1 | VCC | Display power output |
| 2 | A | Display RS485 signal negative | |
| 3 | B | Display RS485 signal positive | |
| 4 | GND | Negative terminal | |
| 5 | K+ | Activate the positive signal | |
| 6 | K- | Activation signal negative electrode | |
| P6 (Acquisition Interface) | 1 | NT1 | Connect the NTC1 temperature probe |
| 2 | GND | Connect the NTC1 temperature probe | |
| 3 | B0 | Total negative battery | |
| 4 | B1 | The first battery positives | |
| 5 | B2 | The second battery positive | |
| 6 | B3 | The third battery positive | |
| 7 | B4 | The fourth battery positive | |
| P7 (Acquisition Interface) | 1 | NTC2 | Connect the NTC2 temperature probe |
| 2 | GND | Connect the NTC2 temperature probe | |
| P8 (Acquisition Interface) | 1 | NT3 | Connect the NTC3 temperature probe |
| 2 | GND | Connect the NTC3 temperature probe | |
| 3 | B8 | Reserved pin | |
| P9 (Acquisition Interface) | 1 | NT4 | Connect the NTC4 temperature probe |
| 2 | GND | Connect the NTC4 temperature probe | |
| P10 (Heating Interface) | 1 | HT- | Heater element negative electrode |
| P11 (Power Input) | 1 | B+ | Power input positive |
| D1 (Bluetooth Connection Indicator) | Steady on when connected, blinking when disconnected. | ||
| P- | Connect to external load or negative terminal of charger (M6 screw) | ||
| B- | Connect to the negative battery terminal (M6 screw) | ||
4.4. DIP Switch Settings for Device Address
The DIP switches are used to set the device address for parallel function. The address range is 0-15.
| Address | DIP Switch 1 | DIP Switch 2 | DIP Switch 3 | DIP Switch 4 |
|---|---|---|---|---|
| 0 (Host) | OFF | OFF | OFF | OFF |
| 1 (Slave) | ON | OFF | OFF | OFF |
| 2 (Slave) | OFF | ON | OFF | OFF |
| 3 (Slave) | ON | ON | OFF | OFF |
| ... | ... | ... | ... | ... |
| 15 (Slave) | ON | ON | ON | ON |
Note: ON indicates the LED is on, OFF indicates the LED is off.


5. Setup and Installation
5.1. Wiring Method
The JIKONG PB1/2A16S-10/15/20P series protection board is suitable for 7-16 series lithium battery packs. The specific wiring method varies depending on the number of cells in the battery pack. Always ensure correct polarity and secure connections.

5.2. Device Activation
Before powering on the protection board, verify that the balance cable is properly connected and that P- and B- are correctly connected. Ensure the protection board is securely fixed to the battery core. Incorrect connections can lead to malfunctions or damage.
The protection board does not have a power-on control switch. It is designed for charging activation mode, meaning the charger voltage should be 2V higher than the battery voltage. After battery assembly, connect the charger to activate the protection board.
Alternatively, the board supports key activation and display activation. If you have an optional display screen and button, simply insert the cable into the display interface and press the button to activate.
6. Operation
6.1. APP Installation
The mobile APP for this product can be obtained by scanning the QR code below. An Android device with version 7 or higher is required.
6.2. Parameter Setting
Parameters can be set via the mobile APP. Refer to the 'Default Parameters' table in Section 3.2 for initial values. Users can adjust settings such as cell count, battery capacity, balance trigger differential pressure, voltage calibration, and current calibration.
6.3. Active Equalization
The protection board uses active equalization to transfer energy from high-voltage cells to low-voltage cells. When the balance function is enabled and the voltage difference between any two battery strings exceeds the set value, equalization automatically starts. It stops when the difference falls below the set value. The default balance current is 1A/2A. It is recommended that the balance current does not exceed 0.2C of the battery capacity. If not needed, the balancing function can be turned off in the APP's BMS control page.
6.4. Heating Function
The board includes a heating function to prevent charging and discharging failures due to low battery activity in cold temperatures. The designed heating current is 10A. Users can enable/disable this function via the APP. It is recommended to install a temperature control switch (45-65°C normally closed type) in series with the heating circuit as a secondary protection to prevent thermal runaway.
6.5. Dry Contact Function
Two dry contacts are provided to control external devices like alarms or fans. When the BMS detects an overtemperature, overcharge, or overdischarge state, the alarm interface can switch the dry contact status to trigger a buzzer or activate a fan. Users can select two trigger conditions and configure them via the APP.

6.6. Protection Functions
The BMS provides comprehensive protection features:
- Charge Overvoltage Protection: Prevents overcharging by shutting off charging when any cell voltage exceeds the set limit. Charging resumes when all cell voltages drop below the recovery voltage.
- Discharge Undervoltage Protection: Prevents over-discharging by shutting off discharge when any cell voltage falls below the set limit. Discharge resumes when all cell voltages rise above the recovery voltage. The board will automatically shut down if any cell voltage drops below the automatic shutdown voltage.
- Charge Overcurrent Protection: Triggers if the charging current exceeds the set continuous charging current for a specified delay. Charging is then stopped and resumes after the overcurrent release time.
- Discharge Overcurrent Protection: Triggers if the discharge current exceeds the set continuous discharge current for a specified delay. Discharge is then stopped and resumes after the overcurrent release time.
- Overtemperature Protection: Shuts down charging/discharging if the temperature exceeds the set overtemperature limit. Operation resumes when the temperature falls below the recovery value.
- Low Temperature Protection: Shuts down charging if the temperature falls below the set low temperature limit. Charging resumes when the temperature rises above the recovery value.
- Short Circuit Protection: Automatically protects against short circuits. The delay and recovery times can be adjusted via the APP. If a short circuit occurs during charging or discharging, the board will stop operation and resume after the recovery time.
6.7. Emergency Switch
In case of issues like over-temperature, over-discharge, over-charge, or string drops during normal use, activating the emergency switch via the APP's BMS control page will enable charge and discharge for 30 minutes. This provides an emergency operational period, even if a single cell voltage has reached the automatic shutdown level, to prevent unexpected power loss.
6.8. Intelligent Sleep
The intelligent sleep function can be enabled or disabled via the APP. Its purpose is to reduce the board's energy consumption when in standby (charging and discharging current less than 1A for 26 consecutive hours). The board can be reactivated by pressing a button or connecting a charger.
6.9. Communication Function
The board supports CAN and RS485 communication. The default CAN communication rate is 250K. Users can select the appropriate protocol in the APP based on their inverter brand. It features two RS485 communication interfaces: RS485-1 for communication with inverters and other settings, and RS485-2 for parallel connection of battery packs and communication with a host computer. The default baud rate is 115200. The communication address can be set using the DIP switches (0-15).
6.10. Charge Current Limiting Function
The board includes a charge current limiting function. Users can set the continuous charging current, delay, and release time via the APP. If the charging current exceeds the set limit, the current limiting function activates, maintaining the charging current at approximately 10A to protect the battery.
6.11. Parallel Function
The parallel function allows simultaneous monitoring of multiple BMS units by a host computer via the RS485 bus. To use this function, you will need a USB to RS485 serial port cable and the JIKONG host computer software.
The parallel function supports up to 16 BMS units. Each BMS must have a unique address from 0 to 15. BMS with address 0 acts as the host, and BMS units with addresses 1 to 15 act as slaves. The host computer connects to the host BMS via a USB to RS485 serial port cable. The RS485-2 ports on the BMS units are then connected to each other using RJ45 Ethernet cables in sequence.
6.12. LED Indicators
The board features various LED indicators to show its status:
| Status | Normal/Alarm/Protection | ON/OFF Indicator | RUN | ALM | L1-L6 | Instructions | |
|---|---|---|---|---|---|---|---|
| Power Off | Normal | OFF | |||||
| Balance | Normal | ON | Flicker | OFF | Battery based display | OFF | |
| Charging | Normal | ON | Flicker | OFF | Battery based display | OFF | |
| Charging | Overcurrent, Overtemperature, Overvoltage, Charging Failure | ON | Flicker | Flicker | Battery based display | OFF | |
| Discharge | Normal | ON | Flicker | OFF | Battery based display | OFF | |
| Discharge | Overcurrent, Overtemperature, Undervoltage, Discharge Failure | ON | Flicker | Flicker | Battery based display | OFF | |
| Other Alarm | Password not changed, Short circuit, Temperature | ON | Flicker | Flicker | Battery based display | OFF | |
6.13. Power LED Description
| Capacity (Electric Quantity) | Charging (L5-L1) | Discharge (L5-L1) | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| 0-20% | OFF | OFF | OFF | OFF | ON | OFF | OFF | OFF | OFF | ON |
| 20-40% | OFF | OFF | OFF | ON | ON | OFF | OFF | OFF | ON | ON |
| 40-60% | OFF | OFF | ON | ON | ON | OFF | OFF | ON | ON | ON |
| 60-80% | OFF | ON | ON | ON | ON | OFF | ON | ON | ON | ON |
| 80-100% | ON | ON | ON | ON | ON | ON | ON | ON | ON | ON |
Note: ON indicates the LED is on, OFF indicates the LED is off.
7. Maintenance
To ensure optimal performance and longevity of your JIKONG Communication Board, consider the following:
- Regular Inspection: Periodically check all wiring connections for tightness and signs of wear or corrosion.
- Cleanliness: Keep the board free from dust and debris. Use a soft, dry cloth for cleaning. Avoid using liquids or abrasive cleaners.
- Environmental Conditions: Ensure the operating environment remains within the specified temperature range (-30°C to 70°C) and humidity levels to prevent damage.
- Firmware Updates: Check the JIKONG APP or official website for any available firmware updates for your BMS, as these may include performance improvements or bug fixes.
8. Troubleshooting
If you encounter issues with your JIKONG Communication Board, refer to the following general troubleshooting steps:
- Check Connections: Verify all wiring, especially the balance cable, P- and B- connections, are secure and correctly polarized.
- Review LED Indicators: Consult the LED indicator tables in Section 6.12 and 6.13 to understand the current status or any active alarms/protections.
- APP Diagnostics: Use the JIKONG APP to check battery working status, error codes, and modify parameters. The APP can provide detailed diagnostic information.
- Protection Triggers: If a protection (e.g., overvoltage, overcurrent, overtemperature) is active, identify the cause and rectify it. The system will typically resume operation once the condition is resolved and the recovery time has passed.
- Emergency Switch: In critical situations, the emergency switch can provide a temporary operational window (30 minutes) to address issues.
- DIP Switch Settings: For parallel configurations, ensure the DIP switch settings for device addresses are correct as per Section 4.4.
For more detailed troubleshooting or persistent issues, refer to the official PDF user manual or contact JIKONG technical support.
9. User Tips
No specific user tips or FAQs were available from provided reviews or Q&A content.
10. Support and Documentation
For detailed technical specifications, wiring diagrams, and comprehensive instructions, please refer to the official user manual PDF:
This PDF document provides in-depth information that may not be fully covered in this summary manual.
For further assistance, please contact JIKONG customer support.
11. Manufacturing Process Overview
Watch a brief video showcasing the manufacturing process of the JIKONG BMS boards, highlighting the precision and care involved in production.