OUKITEL P1000E PLUS

Contents

OUKITEL P1000E PLUS Portable Power Station

User Manual

Model: P1000E PLUS

Brand: OUKITEL

1. Introduction

We deeply appreciate you for purchasing the P1000EPLUS Portable Energy Storage Power Supply. Please read this manual carefully before using the product to ensure correct usage. Keep this manual for future reference, along with your invoice and other purchase certificates.

To guarantee the safety of this product during transportation, it is only about 30% charged when packed. You are required to charge it immediately after opening and before use.

Please avoid the use of extension cords or cable taps. This product should be charged directly from wall sockets. When charging this product with a socket, do not use the same socket as other devices.

1.1. Disclaimers

Before using the product, please read the user manual carefully to ensure that you fully understand it. If you use this product incorrectly, you may cause serious injury to yourself or others, as well as product damage and property damage. By using this product, you are deemed to have understood, recognized, and accepted all the terms of this manual. Users undertake responsibility for their own actions and all consequences that may arise therefrom.

Our company does not assume any responsibility for any loss caused by users' failure to use the product in accordance with the User Guide. In order to comply with laws and regulations, the company has the final interpretation of this document and all related documents of this product.

2. Safety Precautions

  • Avoid high temperature and humidity. Do not use the product in direct sunlight or near a fire.
  • Do not disassemble or modify the product, as it may cause malfunction or even a fire.
  • Dispose of or recycle the product in accordance with local laws.
  • Be careful not to drop the product from a high place or expose it to any form of strong impact.
  • Store or use the product out of the reach of children.
  • Use only genuine accessories provided by the company. Using non-genuine products may void warranty and cause adverse consequences.
  • When using, do not interfere with the cooling of the product. Ensure a ventilation space of more than 30cm from the side suction and exhaust ports.
  • When not in use, power off the unit and unplug the power cord. Avoid storing in places with high temperature, high humidity, or direct sunlight.
  • For long-term storage, deplete the charge once every 3 months, then recharge to about 50%.
  • If there is any doubt about product body, auxiliary line, or connecting equipment defects, do not continue use. Contact after-sales personnel.
  • Do not store the product for a long time in a car or field warehouse or other places that may experience extreme high and low temperatures, to prevent battery life shortening.
  • Medical Equipment Limitation: This product is not intended as a power supply for medical equipment such as ventilators or ECMO. Consult the manufacturer before using with other medical devices to ensure no restrictions on external power supply use.
  • Electromagnetic Fields: Power supply products may generate electromagnetic fields. If you use medical implants (pedicles, cochlear implants, hearing aid defibrillators, personal medical devices), contact us regarding usage restrictions. Ensure sufficient range from medical implants.

3. Packing List

The package includes the following items:

  • P1000EPLUS Portable Energy Storage Power Supply
  • AC power cord
  • MC4-XT60 cable
  • User Guide
P1000EPLUS Portable Power Station, AC power cord, MC4-XT60 cable, and User Guide
Figure 3.1: Contents of the P1000EPLUS package.

4. Product Overview

The OUKITEL P1000E PLUS is a portable power station designed for various applications including home emergency power backup, outdoor travel, and emergency disaster relief. It features a built-in LiFePO4 battery, supporting AC fast charging, vehicle charging, and solar photovoltaic panel charging.

This product also includes a UPS (Uninterruptible Power Supply) function, allowing it to switch to battery power within 10ms during a utility power failure, ensuring continuous power to connected electrical equipment. The AC output provides a pure sine wave waveform and can be manually converted between 50Hz and 60Hz for compatibility with different electrical appliances.

4.1. Key Features

  • High Capacity & Output: 1024Wh battery capacity with 1800W rated power output (up to 3600W peak).
  • LiFePO4 Battery: Advanced LFP cells deliver up to 4000 cycles at 70% capacity, offering a 10-year lifespan.
  • Fast Charging: 1200W AC input charges to 80% in 39 minutes.
  • Multiple Charging Options: AC outlet, solar power (Max 500W), and car charging.
  • UPS Functionality: Seamless 1800W UPS with <10ms switchover time.
  • Quiet Operation: Less than 29 dB noise level under 500W load.
  • Portability: Lightweight and portable design for easy transport.
  • Smart App Control: Remote control via Wi-Fi and Bluetooth.
  • Versatile Outputs: Multiple AC, DC, USB-A, USB-C, and car lighter ports.
OUKITEL P1000E PLUS Portable Power Station with 1800W output and 1024Wh capacity
Figure 4.1: OUKITEL P1000E PLUS Portable Power Station.
Lightweight and Portable design of the OUKITEL P1000E PLUS, showing dimensions 13 inches length, 8.7 inches width, 9 inches height
Figure 4.2: Dimensions and portability of the power station.
OUKITEL P1000E PLUS charging from an AC outlet, showing 70% battery capacity in 30 minutes and 100% in 50 minutes
Figure 4.3: Fast charging capabilities of the power station.
Internal view of the LiFePO4 battery cells, highlighting 4000 cycles at 70% capacity
Figure 4.4: Reliable LiFePO4 Battery technology.
Overview of the OUKITEL P1000E PLUS features including 1024Wh battery, 1800W output, 1800W UPS, 1200W AC fast charging, 500W solar input, smart app control, and ultra-quiet operation
Figure 4.5: Comprehensive feature overview.
Diagram showing the OUKITEL P1000E PLUS providing power to various household devices like a projector, TV, and router, illustrating its 1800W output capability
Figure 4.6: Powering household devices with 1800W output.
Image showing the OUKITEL P1000E PLUS connected to a desktop setup with a monitor, keyboard, and laptop, demonstrating its UPS function during a power outage
Figure 4.7: Seamless UPS functionality for critical devices.
A hand holding a smartphone displaying the OUKITEL P1000E PLUS app interface, showing remote control and monitoring capabilities
Figure 4.8: Smart App Control for remote management.

5. Setup and Operation

5.1. Controls and Display Interface

Diagram of the OUKITEL P1000E PLUS front and rear panels with numbered labels for each control and port.
Figure 5.1: Front and Rear Panel Overview.

The power station features a clear LCD screen and various control buttons and ports. Refer to Figure 5.1 for the location of each component.

  1. Power switch
  2. DC switch
  3. AC switch
  4. LED light switch
  5. LED light
  6. LCD screen
  7. DC5521 output ports
  8. Cigar Lighter port
  9. USB-A/Type-C ports
  10. AC Output ports
  11. AC charging port / Overload protection button
  12. External grounding port
  13. AC fast/slow charge adjustment switch
  14. PV/Car input port
  15. Cooling air inlet/outlet

5.2. Power On/Off

To turn on the power system and LCD display, press and hold the power button (1) for 3 seconds. To turn off the power system, press and hold the power button (1) again for 3 seconds.

5.3. DC Output Control

Short press the DC button (2) to turn on the DC output ports. Short press it again to turn them off.

Port TypeOutput
Cigar Lighter (8)12V/10A
DC5521 Output (7)12V/3A
USBQC3.0 (9)(5-12V18W) x2
Type-C (9)(5-12V20W) x1
Type-C (PD 100W) (9)(5-15V/3.0A; 20V/5A 100W) x1

5.4. AC Output Control

Short press the AC button (3) to turn on the AC output ports. Short press it again to turn them off. The total electrical power load should be less than 1800W.

  • Voltage and Frequency: AC output voltage and frequency standards vary by country. Verify compatibility with your equipment.
  • Frequency Switching: Press the AC button (3) and LED button (4) simultaneously for 3 seconds to switch the frequency between 50Hz and 60Hz.
  • Voltage Switching: Press the AC button (3) 10 times in a row to switch the AC output voltage between 220V/230V/240V.

Output: 220-240V/1800W (EU), 50/60Hz, pure sine wave.

5.5. LED Light Control

Short press the LED button (4) to cycle through constant light mode, SOS mode, and flashing mode. Long press the LED switch to turn on silent mode, and long press again to turn off silent mode.

5.6. Charging the Power Station

5.6.1. AC Charging

Use the standard AC charging cable to connect the mains power to the AC charging port (11). Ensure the AC voltage and frequency of the device are consistent with the mains power before charging.

If the power voltage supply is unstable or there is a large voltage input, the overload protection function will automatically activate and disconnect the AC input port. To restore AC input:

  1. Turn off the power button and unplug all connected devices.
  2. After confirming no abnormalities, turn on the power button.
  3. Press the overload protection button (11) and connect the AC line to restore AC input.

The AC fast/slow charge adjustment switch (13) allows you to select charging speed:

  • Fast Charging Mode: Output voltage of power supply equipment must meet 200-240V. Maximum charging power is 1200W.
  • Slow Charging Mode: Output voltage of power supply equipment must meet 200-240V. Maximum charging power is 500W.
OUKITEL P1000E PLUS charging from an AC outlet, showing 80% charge in 39 minutes with 1200W AC input
Figure 5.2: AC Fast Charging.

5.6.2. Solar Charging

Use the standard PV/Car port charging cable (MC4-XT60) to connect a solar panel to the PV/Car input port (14) to charge the product. The maximum input for solar panels is 500W, with a maximum input voltage of 50V.

Important: Solar panel voltage over 50V will damage the device and may void the warranty. The charging power of solar panels is determined by weather and climate conditions.

Diagram showing the OUKITEL P1000E PLUS connected to a solar panel for charging. Option 1: Direct connection to a single solar panel. Option 2: Connection to multiple solar panels in series/parallel.
Figure 5.3: Solar Panel Connection Options.
OUKITEL P1000E PLUS charging from a solar panel, showing full charge in 2 hours with Max 500W solar input
Figure 5.4: Solar Charging.

5.6.3. Car Charging

To charge using a car, turn on the product's power, connect the ACC charging cable to the car's cigarette lighter and the XT60 interface on the side of the product (PV/Car input port 14). Then, start the car engine. The LCD screen will display the input power.

Note: Onboard charging should be done when the car engine is started. Failure to start the engine may cause the car's battery to run out of power. Car charging is typically low power (90-240W), resulting in longer charging times (12V/8A or 24V/10A). For faster charging, utility power is advised.

Diagram showing the OUKITEL P1000E PLUS connected to a car's cigarette lighter for charging.
Figure 5.5: Car Charging Connection.
OUKITEL P1000E PLUS charging in a car, showing full charge in 6 or 12 hours depending on 12V/24V input
Figure 5.6: Car Charging.

5.7. UPS Mode Operation

The P1000E PLUS features a bypass mode, allowing direct output from AC power without passing through the battery. In UPS mode, if the city's AC input is suddenly interrupted, the product automatically switches to battery power within 10ms, ensuring continuous operation of AC equipment.

To use UPS mode, connect the product between the wall socket and your electrical appliances, and ensure the product's power is ON. When the mains power is cut off, the power station will automatically switch to its internal battery power supply.

  • In UPS mode, the maximum current for Japanese and American regulations is 14A.
  • For Chinese, British, European, and Korean regulations, the maximum current is 10A.
  • If the AC output exceeds the maximum current, the UPS icon will flash, indicating overload, and the AC icon will go out, interrupting the output.
Diagram illustrating the UPS connection: wall socket -> OUKITEL P1000E PLUS -> TV, showing power flow.
Figure 5.7: UPS Connection Diagram.

5.8. Cooling System

The cooling fan will automatically activate when the product reaches a certain temperature during use. Do not block the cooling air inlet/outlet (15), and ensure no objects are placed within 30cm of these vents.

6. Screen Display Precautions

The LCD screen (6) displays the power and usage status of the product. Pay attention to the following icons:

  • Fan Icon: When this icon is on, ensure the air inlet on both sides of the product is not blocked.
  • Temperature Icon (H/L): If this icon flashes, the internal temperature is too high (H) or too low (L). The device will activate intelligent protection and stop working. Wait for the machine to return to normal temperature before restarting.
  • Port Output Abnormal Icon: If this icon flashes, it indicates that the corresponding port output is abnormal. Check the connected load.
  • Silent Mode Icon: If this icon flashes, the product has entered silent mode.

7. Specifications

ParameterValue
Product NameP1000EPLUS
Product Size (L*W*H)346mm * 228mm * 238mm
Product Weight11.6KG
Battery Capacity1024Wh (51.2V)
Battery TypeLiFePO4
Cycle Life≥4000 cycles (to 70% capacity)
Rated Power1800W
AC Output220-240V/1800W (EU), 50/60Hz, Pure Sine Wave
AC Charge Input200-240V, MAX 1200W (EU)
PV Input (Solar)12-50V, MAX 500W
Car Charger Output12V/10A
USB-A OutputQC3.0 (5-12V18W) x2
USB-C Output(5-12V20W) x1, (5-20V/5.0A) x1 (PD 100W max)
DC5521 Output12V/3A x2
Cigar Lighter Output12V/10A
UPS220-240Vac/MAX10A (EU)
Charging Temperature0-40°C
Operating Temperature-10~40°C
Ambient Humidity<90%RH

8. Maintenance

  • Storage Environment: It is recommended to use or store this product in an environment of 20°C to 30°C, away from water, heat, and other metal objects.
  • Temperature Limits: For safety reasons, do not store this product in an environment higher than 40°C or lower than -10°C for a long time.
  • Long-Term Storage: If not used for a long time, charge it to 50% before storing. If the battery is left seriously insufficient for a long time, it will cause irreversible damage and shorten the cycle life.
  • Cleaning: Use a dry, soft, clean cloth or tissue to wipe the product.

9. Troubleshooting (FAQ)

Q: The load power is within the rated range but cannot be used normally?
A: The product may have low power and needs to be charged. Also, the peak power of some specific loads can exceed the rated power several times when starting, preventing normal operation.
Q: Does the product make noise when used?
A: When the device is started or in use, fans and some inductive components will operate, resulting in a low sound. This is normal.
Q: Is it normal for the charging cable to get slightly hot during use?
A: Yes, it is normal. When the charging power is high, there will be slight heating. The cables and wires have been strictly tested and comply with safety standards.
Q: What kind of batteries are used?
A: The battery type is lithium iron phosphate (LiFePO4) and complies with relevant safety standards.
Q: What devices does the AC output port support?
A: It supports equipment with a rated power less than 1800W. It can power more than 95% of household appliances. Before use, confirm that the output current of a single interface does not exceed the rated output current of the AC port.
Q: How can I know the remaining usage time?
A: During use, the remaining usage time is displayed on the left side of the screen.
Q: How to confirm if the device is charging?
A: When charging, the screen will display the charging power, the synchronous power display area will scroll, and the AC or PV charging icon will be displayed.
Q: Can I bring this product on a plane?
A: You can bring your device on board the plane.
Q: Is the actual capacity the same as the manual's stated capacity?
A: The manual states the rated capacity of the battery pack. Due to efficiency loss during charging and discharging, the actual output capacity will be lower than the specified capacity.
Q: What is the maximum output power of a single AC interface?
A: The maximum output power of a single AC interface cannot exceed the product's rated output power.

10. User Tips

  • For optimal performance and battery longevity, ensure the power station is charged to about 50% for long-term storage.
  • Always use the provided original cables and accessories to prevent damage and ensure warranty validity.
  • When using the UPS function, be aware of the maximum current limits (14A for JP/US, 10A for CN/UK/EU/KR) to avoid overload.
  • Keep ventilation areas clear to prevent overheating, especially during heavy use.

11. Warranty and Support

This product comes with a warranty. For detailed warranty information, terms, and conditions, please refer to the official product documentation or contact customer support. The user manual (PDF) can be viewed for additional item guides and documents.

For further assistance or technical support, please refer to the contact information provided in your purchase documentation or visit the official OUKITEL website.

A PDF version of the user manual is available for download: OUKITEL P1000EPLUS User Manual (PDF)

12. Product Video Overview

Play video
Watch video online
Video 12.1: Unboxing and basic operation of the OUKITEL P1000 Plus portable power station.
Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.