1. Introduction
The KeepLiNK KP-9000-45-5TXm is a cost-effective Industrial Ethernet Switch designed for harsh environments, offering high quality and reliability. It is suitable for applications where switch management is not required, such as field-level industrial networks, smaller infrastructures, outdoor IoT, citywide surveillance, transportation, and general industrial applications.
This industrial Ethernet switch provides excellent industrial quality, including vibration resistance, high/low temperature tolerance, dustproof, and surge protection. It features a fanless heat dissipation circuit design, wide operating temperature range, and high protection grade. The device integrates various protocols for routing, switching, and security, enhancing networking flexibility, reliability, and security for industrial networks. It meets deployment requirements for rail transit, safe cities, intelligent transportation, outdoor monitoring, and other challenging environments.

Figure 1.1: KeepLiNK Industrial Switch highlighting its robust features.
2. Specifications
| Category | Feature | Description |
|---|---|---|
| General | Brand Name | KeepLiNK |
| Model Number | KP-9000-45-5TXm | |
| Origin | Mainland China | |
| Switch Properties | Switch Type | Gigabit Switch |
| Transmission Rate | 10/100Mbps | |
| Switch Capacity | 32G (Note: Product description states 1G, refer to product for exact capacity) | |
| Communication Mode | Full-Duplex & Half-Duplex | |
| Function | VLAN Support | |
| Packet forwarding rate | 0.744 Mpps | |
| MAC address table | 2 K | |
| Buffer | 768 K | |
| Forwarding delay | <5 µs | |
| Interface | Fixed Ports | 5 * 10/100/1000 Base-T Fast Ethernet ports |
| Power Interface | 3-contact Phoenix Terminal, redundant dual power supply | |
| LED Indicators | P1/P2 (Power), Link/ACT (Per Port) | |
| Cable Type & Transmission Distance | Twisted-pair | 0-100m (CAT5e, CAT6) |
| Network Topology | Ring topology | Unsupported |
| Star topology | Supported | |
| Bus topology | Supported | |
| Tree Topology | Supported | |
| Hybrid topology | Supported | |
| Power Parameters | Input voltage | 12 to 58 VDC (DC10-58V as per manual) |
| Power consumption | <5 W | |
| Environmental Limits | Operating temperature | -40°C ~ +75°C (Note: Product description states -30°C ~ +75°C, refer to product for exact range) |
| Storage temperature | -30°C ~ +75°C | |
| Relative humidity | 5% ~ 95% non-condensing | |
| Thermal methods | Fan-less, natural cooling | |
| MTBF | 100,000 hours | |
| Physical Characteristics | Dimensions | 95 x 91 x 31 mm |
| Installation | DIN-rail mounting | |
| Weight | 0.3 Kg | |
| Standards & Certifications | IP Level | IP40 |
| EMI | FCC PART 15B CLASS A | |
| EMS - Surge protection (Power) | IEC 61000-4-5 Level X (4 kV/2 kV) (8/20 µs) | |
| EMS - Surge protection (Ethernet) | IEC 61000-4-5 Level X (4 kV/2 kV) (10/700 µs) | |
| EMS - RS | IEC 61000-4-3 Level 3 (10 V/m) | |
| EMS - EFT | IEC 61000-4-4 Level 3 (1 V/2 V) | |
| EMS - CS | IEC 61000-4-6 Level 3 (10 V/m) | |
| EMS - PFMF | IEC 61000-4-8 Level 4 (30 A/m) | |
| EMS - DIP | IEC 61000-4-11 Level 3 (10 V) | |
| EMS - ESD | IEC 61000-4-2 Level 4 (8 K/15 K) | |
| Authentication | Certificates | CE, FCC, RoHS |
| Freefall | 0.5 m |
3. Package Contents
The product package should contain the following items:
- KeepLiNK Industrial Ethernet Switch
- Phoenix Terminal Block
- User Manual (this document)
- Warranty Card
4. Installation
4.1 DIN Rail Installation
The Industrial Ethernet switch is designed for DIN rail installation. Follow these steps to properly mount the device:
- Tilt the device upwards, ensuring the clasp on the upper end of the device hooks onto the DIN rail.
- Press the device downwards until the lower end of the buckle securely latches into the DIN rail.
- Verify that the device is stable and securely fastened after buckling.

Figure 4.1: DIN Rail Installation Steps.
5. Power Connection
5.1 PoE Line Sequence Introduction
This device supports Power over Ethernet (PoE) according to 802.3AF and 802.3AT standards. The switching power supply should be between DC 48V and DC 58V. PoE connections must align with network cable connections, utilizing cables 1, 2, 3, and 6 for both data transmission and PoE power supply.
5.2 Power Input
The Industrial Ethernet switches feature dual power backup. If two power supplies are connected, only one operates at a time. Should the active power supply fail, the device automatically switches to the other, providing redundant power protection. The power wiring details are provided below:
| Terminal | Meaning |
|---|---|
| P1+ | First circuit power supply positive pole |
| P1- | First circuit power supply negative pole |
| P2+ | Second circuit power supply positive pole |
| P2- | Second circuit power supply negative pole |
| P1/P2- | First and second circuit share a negative pole |
| + | Positive pole of power supply |
| - | Negative pole of power supply |
Note: Please connect the positive and negative poles according to the Phoenix terminal's markings and ensure the input voltage is within the specified range (generally DC10-58V, as described on the side cover). Only one power supply will operate at a time.

Figure 5.1: Power Installation Diagram.
6. LED Indicator Lights
The device features several LED indicators to provide status information:

Figure 6.1: Front panel with LED indicators.
| Indicator Lamp | State | Meaning |
|---|---|---|
| P/P1/P2/PS1/PS2/PWR (Power) | Flashes uniformly (1s) | Power supply under-voltage alarm (below DC10V) |
| Off | Power channel not powered | |
| On | Power channel is powered | |
| O/OPT (Fiber-port) | Flashes uniformly (0.5s) | Power supply overvoltage alarm (exceeds DC58V) |
| Off | Fiber port not connected | |
| On | Fiber port is connected | |
| Flash | Fiber port is connected and data is sent/received | |
| A/ALM (Device Alarm) | On | Device has alarms (Temperature, LFP, Dying-gasp) |
| Off | Device has no alarm | |
| N/NMC (Management/Data Receiving) | Off | No embedded module |
| On | Embedded module initializing | |
| Flash | Console/RS232/RS485 data reception | |
| RUN (Running) | On | Device works normally |
| 1000Mbps Copper Port (Green Active) | On | Port is connected |
| Off | Port not connected | |
| Flash | Port is connected and data is sent/received | |
| 1000Mbps Copper Port (Yellow SPD) | On | 1000M is connected |
| Off | 10/100M is connected | |
| 100Mbps Copper Port (Green Active) | On | Port is connected |
| Off | Port not connected | |
| Flash | Port is connected and data is sent/received | |
| 100Mbps Copper Port (Yellow SPD) | On | 100M is connected |
| Off | 10M is connected | |
| Reset/Configurate Push-button | Long press (> 20s) | Restore factory setup / restart |
7. DIP Switch Settings (Unmanaged)
The device includes DIP switches for configuring specific functions. As this is an unmanaged switch, refer to the table below for their functions:
| DIP Switch | Function | ON State | OFF State |
|---|---|---|---|
| Bit1 (Silk-screen: LFP / (C/D)) | LFP (Link Fault Pass-through) | Enable remote PD reset function (LFP enabled for 1 fiber and 1 copper switch) | Turn off remote PD restart function (LFP turned off for 1 fiber and 1 copper switch) |
| Bit2 (Silk-screen: LGY) | LEGACY function switch | Support standard and non-standard PD power supply | Only supply power to standard PD, no support for non-standard PD power supply |
| Bit3 (Silk-screen: VLAN) | Port Isolation function | Enable port isolation function | Turn off port isolation function |
| Bit4 (Silk-screen: BSR / RST) | BSR: Storm Control | Enable storm control | Turn off storm control |
| RST: Remote PD Reset Every Day function | Reset the remote PD device after 24 hours | Turn off this function |
8. User Tips
No specific user tips were available from customer reviews or Q&A for this product.
9. Troubleshooting
If you encounter issues with your Industrial Ethernet Switch, consider the following common troubleshooting steps:
- No Power: Check the power connections to the Phoenix terminal block. Ensure the input voltage is within the 12-58 VDC range. Verify that the power supply is functional and correctly wired to P1+ and P1-. If using redundant power, check both supplies. The PWR LED should be ON. If it flashes, there might be an under-voltage issue.
- No Link/Activity: If a port's Link/ACT LED is off, check the Ethernet cable connection to both the switch and the connected device. Ensure the cable is not damaged and is a CAT5e or CAT6 twisted-pair cable within 100m length. Verify the connected device is powered on and functioning correctly.
- Slow Connection: Ensure your connected devices are compatible with 10/100Mbps speeds. Check for excessive network traffic or faulty cables.
- Device Alarms: If the A/ALM LED is ON, the device has an active alarm (e.g., temperature, LFP, Dying-gasp). Refer to the full user manual for specific alarm codes or contact support.
- Reset to Factory Settings: If the device is unresponsive or misconfigured, you can restore it to factory settings by pressing and holding the Reset/Configurate push-button for more than 20 seconds.
10. Maintenance
To ensure optimal performance and longevity of your Industrial Ethernet Switch, follow these maintenance guidelines:
- Cleaning: Regularly clean the exterior of the device with a soft, dry cloth. Avoid using liquid cleaners or solvents. Ensure ventilation openings are free from dust and debris to maintain natural cooling efficiency.
- Environmental Conditions: Operate the switch within the specified environmental limits for temperature and humidity. Avoid exposing the device to direct sunlight, excessive heat, or moisture.
- Cable Management: Ensure all network and power cables are securely connected and properly routed to prevent accidental disconnections or damage.
- Firmware Updates: Check the manufacturer's website periodically for any available firmware updates. Follow the provided instructions carefully for any update procedures.
11. Warranty and Support
11.1 After-sales Service Letter of Commitment
Repair, Replacement, and Return:
- Within seven days from the date of sale, if the whole machine fails, you may choose to repair, replace, or return the equipment.
- From the 8th to the 15th day from the date of sale (subject to the purchase invoice and certificate date of three guarantees), if there is any performance failure, you may choose to repair or replace the whole machine.
Warranty Period:
- Our company provides a 2-year warranty period (which can be extended to 5 years according to the contract).
- If the hardware warranty period is exceeded, the user will bear the cost of replacing the hardware; no additional fees will be charged by our company.
Other Service Commitments:
- Within one year from the date of purchase, if the equipment cannot be repaired within 30 days due to unavailability of spare parts, or if the equipment failure cannot be resolved after two repairs, our company will replace it with the same type and specification free of charge.
- If an engineer cannot resolve the problem under unusual circumstances, our service engineer will negotiate with you to return the equipment for repair. After repair, the equipment will be sent back to you free of charge.
Circumstances Not Covered by Warranty:
Failure or damage of equipment (including parts) under the following circumstances are not covered by warranty:
- Accessories supplied by other companies (e.g., power supply, adapter) are guaranteed by their respective manufacturers.
- The whole machine and parts have exceeded the warranty period.
- Equipment failure or damage caused by unauthorized repair, alteration, or demolition by personnel not from our company.
- Malfunctions caused by accidental or artificial causes, including improper operation, scratching, handling, moving, knocking, or inputting inappropriate voltage.
- Failure or damage caused by the use of non-genuine or unpublished software.
- Failures or losses caused by natural disasters or force majeure (e.g., earthquakes, fires).
For complete and up-to-date warranty information, please refer to the official PDF user manual: View User Manual (PDF)