1. Introduction
The Hti HT-18+ Handheld Thermal Imager is a professional, precise, and efficient infrared imaging device designed for various applications. It integrates surface temperature measurement with real-time thermal imaging, allowing users to quickly identify problem areas by blending visible and infrared images. This device is an ideal tool for electricians, maintenance personnel, and technicians across diverse fields.
Key features include a 256x192 infrared image resolution, a 3.2-inch full-color display, and a temperature measurement range of -20℃ to 300℃. Its ergonomic design ensures comfortable one-hand operation, making it convenient for long-term use.
2. Product Overview
The HT-18+ thermal imager features a robust design with clearly labeled components for ease of use.

- Protective Cover: Shields the lens when not in use.
- Visible Light Camera: Captures standard visual images.
- Infrared Thermal Image Sensor: Detects infrared radiation to create thermal images.
- Display: 3.2-inch full-color screen for viewing thermal and visible images.
- Button Area: Contains navigation and function buttons.
- Image Capture Button: Triggers image saving.
- Handheld Area: Ergonomically designed grip.
- Battery Compartment: Houses the built-in rechargeable 18650 batteries.
- Micro USB 2.0 Interface: Used for charging and data export.

3. Specifications
| Feature | Specification (HT-18+) |
|---|---|
| Model | HT-18+ |
| Display | 3.2'' full-color screen |
| Infrared Image Resolution | 256x192 |
| Total Pixels | 35,200 pixels |
| Visible Image Resolution | 0.3 million pixels |
| Thermal Sensitivity | 0.07°C |
| Temperature Range | -20℃ to 300℃ (-4℉ to 572℉) |
| Measuring Accuracy | ±2.5℃ or ±2.5% |
| Emissivity | 0.1-10.0 Adjustable |
| Focus Mode | Fixed |
| Image Frequency | 8Hz |
| Vision Option | Full infrared and full vision, visible image with 25% steplength blending |
| Image Storage | Built-in 4G |
| Image Format | JPG |
| USB Interface | Micro USB 2.0 |
| Power Supply | Built-in rechargeable 18650 batteries |
| Auto Power-off Time | 5 minutes / 20 minutes / Off (manual) |
| FOV/Shortest Focal Length | N/A |
| Wavelength Range | 8-14μm |
| Dimensions | 223 x 105 x 90 mm |
| Weight | 289g |
| Palette Options | Iron red, rainbow, rainbow high contrast, gray scale (white glow), gray scale (black glow) |
| Set Control | N/A |
| Certifications | CE, RoHS |
| Operating Temperature | 0 to 50°C |
| Storage Temperature | -40 to 80°C |
| Relative Humidity | <85% RH |
4. Getting Started
4.1 Unpacking
Carefully unpack your HT-18+ Thermal Imager and check for the following items:

- 1 x Infrared Thermal Imager (HT-18+)
- 1 x USB Cable
- 1 x User Manual (this document and a printed version)
- 1 x Carry Pouch
- 1 x Carry Pouch Strap
- 1 x Cardboard Package Box
4.2 Charging the Device
The HT-18+ is powered by built-in rechargeable 18650 batteries. Before first use, ensure the device is fully charged.
- Locate the Micro USB 2.0 interface on the device (refer to Figure 2.2).
- Connect the provided USB cable to the device and to a compatible USB charger (e.g., a standard phone charger or computer USB port).
- The charging indicator on the device will show its status. Allow sufficient time for a full charge.

4.3 Power On/Off
- To Power On: Press and hold the power button (usually marked with a power symbol) until the display illuminates.
- To Power Off: Press and hold the power button until the device shuts down. The device also supports automatic power-off after 5 or 20 minutes of inactivity, which can be configured in the settings.
5. Basic Operation
5.1 Display Overview
The 3.2-inch full-color display shows real-time thermal images, temperature readings, and menu options. The device automatically tracks the hottest, coldest, and center points on the screen, displaying their temperature values in real-time.

5.2 Temperature Measurement
Point the thermal imager at the target object. The central point measurement cursor helps to quickly and accurately measure the temperature of the target. The device will automatically highlight and display the maximum, minimum, and central temperatures within the field of view.

5.3 Image Capture
To capture an image, press the dedicated image capture button (refer to Figure 2.1). Images are saved in JPG format to the built-in 4G storage.
5.4 Settings and Customization
Navigate through the menu using the directional buttons and 'MENU', 'SELECT', 'ENTER' keys to adjust various settings:

- Language: Select your preferred language (e.g., English, Chinese, Italian, German).
- Palette: Choose from various color palettes like Iron red, rainbow, rainbow high contrast, gray scale (white glow), and gray scale (black glow) to visualize temperature differences.
- Emissivity: Adjust emissivity (0.1-10.0) based on the material being measured for accurate readings.
- Auto Power-off Time: Set the device to automatically power off after 5 or 20 minutes of inactivity, or disable this feature.
- Vision Option: Adjust the blending of full infrared and full visible images, with a 25% steplength for visible image integration.
6. Advanced Features
6.1 Powerful Offline Analysis Capabilities
The HT-18+ supports PC-side offline software for professional temperature analysis. This software allows you to analyze captured thermal images in detail and quickly generate analysis reports.

6.2 Hotspot Tracking and Dual Light Fusion
The device features automatic hotspot tracking, identifying and highlighting the hottest areas. It also offers dual light fusion, combining thermal and visible light images for enhanced detail and easier problem identification.

7. Product Applications
The HT-18+ thermal imager is widely used in various fields due to its versatility and precision:

- Building Inspection: Detecting floor heating hot water pipe leaks, insulation issues, and HVAC maintenance.
- Electrical Inspection: Identifying faults in distribution boxes, electrical equipment, and power systems.
- Automotive Maintenance: Diagnosing issues in car engines and other components.
- Industrial Manufacturing: Process evaluation and equipment maintenance.
- Other Fields: Fire fighting, archaeology, traffic, agriculture, geology, energy, smelting, electronic manufacture, and product testing.

7.1 Product Demonstration Video
Watch this video for a visual demonstration of the HT-18+ thermal imager's features and operation.
8. Maintenance and Care
- Cleaning: Use a soft, dry cloth to clean the device. For the lens, use a specialized lens cleaning cloth and solution. Do not use abrasive cleaners or solvents.
- Storage: Store the device in its carry pouch in a cool, dry place, away from direct sunlight and extreme temperatures. The recommended storage temperature is -40°C to 80°C, with relative humidity below 85% RH.
- Battery Care: For optimal battery life, avoid fully discharging the battery frequently. If storing for an extended period, charge the battery to about 50% and recharge every few months.
9. Troubleshooting
- Device not powering on: Ensure the battery is charged. Connect the device to a charger and try again. If the issue persists, contact support.
- Inaccurate temperature readings: Check the emissivity setting for the material being measured. Ensure the lens is clean and free from obstructions. Avoid measuring through reflective surfaces like glass.
- Display issues (e.g., frozen screen): Try restarting the device by holding down the power button.
- Cannot save images: Check if the built-in 4G storage is full. If so, transfer images to a computer and delete them from the device.
10. Warranty and Support
For detailed warranty information and technical support, please refer to the official user manual PDF provided with your product. You can also find the digital version of the user manual here: HT-18+ User Manual (PDF).
The device is certified with CE and RoHS standards.