1. Safety Information
⚠ Warning:
To avoid danger of suffocation, keep this bag away from babies and children. Do not use this bag in cribs, beds, carriages, or playpens. This bag is not a toy.
This device is designed for electrical systems. Installation and operation should only be performed by qualified electrical professionals.
Observe all local and national electrical codes and regulations during installation and use.
The product is CE certified and complies with RoHS directives.
CE marking and recycling symbols indicating compliance with European standards and proper disposal guidelines.
2. Product Overview
The TOMZN DDS238-VAP-W is a 2P 85-300VAC 63A adjustable over-voltage and over-current protector with under-current protection and power monitoring capabilities. It is specifically designed for single-phase two-wire AC circuits and features an intelligent water pump control system.
This device measures active energy (kWh) and provides real-time display of current (A), voltage (V), and active power (W). It incorporates multiple protection functions to safeguard electrical equipment and optimize water pump operation.
Key Features:
- LCD Display: Backlit display shows total active energy (kWh), real-time current (A), voltage (V), and active power (W).
- Integrated Protection: Features overvoltage, overcurrent, and undercurrent protection.
- Water Pump Control: Automatic control of water pump operation based on user-defined upper and lower current thresholds. This helps prevent dry running or overflow.
- Cyclic Working Time: Allows setting of fixed interval times for water pump on/off cycles.
- Lightning Protection: Built-in lighting protection function.
- Power-off Memory: Retains settings after power loss.
- LED Indicators: Clearly show protection status and power status.
- High Accuracy: Voltage/current/active power accurate to 0.50%, active energy accurate to +1% (IEC62053-21).
The DDS238-VAP-W protector featuring an intelligent water level control system, capable of automatically managing water pump operation based on set limits.
3. Setup and Installation
Important: Installation must be performed by a qualified electrical professional.
- Upon receiving the product, ensure it is undamaged.
- Connect the equipment strictly in accordance with the provided wiring diagram specifications.
- After wiring, adjust the equipment parameters as described in the 'Operation' section.
Product Appearance and Controls:
Front view of the DDS238-VAP-W, showing the N input, L input, overvoltage indicator, overcurrent indicator, undercurrent indicator, LCD, Power indicator, Set button, and Up/Down key adjustment buttons.
- N input / L input: Neutral and Live wire input terminals.
- N output / L output: Neutral and Live wire output terminals.
- Overvoltage indicator (>V): Lights up when overvoltage protection is active.
- Overcurrent indicator (>A): Lights up when overcurrent protection is active.
- Undercurrent indicator ( Lights up when undercurrent protection is active.
- Power Indicator: Indicates the device is powered on.
- LCD: Displays various parameters and settings.
- SET button: Long press for 5 seconds to enter setting state.
- Up (▲) / Down (▼) keys: Adjust parameter values.
Wiring Diagram:
Wiring diagram showing connection of the Voltage Protector (DDS238-VAP-W) with an Air Circuit Breaker and Power Switch. Ensure proper connection of Live (L) and Neutral (N) lines, penetrating the insulating layer of power lines when screwing down.
The diagram illustrates a typical installation with an Air Circuit Breaker and a Power Switch. Ensure the Live (L) and Neutral (N) wires are correctly connected to the input and output terminals of the protector. When connecting, screw down firmly to penetrate the insulating layer of the power lines for a secure connection.
4. Operation
The DDS238-VAP-W uses a long-life HTN ultra-wide temperature LCD screen for clear parameter display. Use the SET, Up (▲), and Down (▼) buttons to navigate and adjust settings.
LCD Display Instruction:
The LCD displays RMS voltage and current, total active energy (kWh), and RMS active power in normal working status. In setting mode, it shows parameters like Function mode (dE), Backlight mode (b9), Delay in load switch on after input power on (SS), Overvoltage protection value (Uo), Overvoltage recovery value (UoH), Overvoltage fault judgment time (SU), Upper limit protection (Io), Lower limit protection (IL), Current limit judgment time (SI), and Recycle working time setting for water pump (SH).
Parameter Settings:
Long press the 'SET' button for 5 seconds to enter the setting state. Use the Up (▲) and Down (▼) keys to adjust values. Press 'SET' briefly to move to the next parameter.
| LCD Code | Parameters Setting | Default | Max. | Min. | Marking |
|---|---|---|---|---|---|
| dE | Function mode | 1 | 3 | 1 | Mode 1: overvoltage protection and current limit protection automatic switch off/on, the time unit is minute. Mode 2: overvoltage protection and current limit protection automatic switch off/on, the time unit is hour. Mode 3: overvoltage protection and current limit protection man-made switch off/on. |
| b9 | Backlight mode | 2 | 2 | 1 | Mode 1: always lighting. Mode 2: means it will light up for 10s after you press any button, it will turn off after 30s if no any operation with button. |
| SS | Delay time in load switch on after input power on | 2s | 512s | 2s | It means switch on the output load after this delay time when the input has power on again. It is only work under function mode 1 and mode 2. |
| Uo | Overvoltage protection value | 270V | 300V | 85V | If the value exceed this range, the LCD will display 'OFF' and closes this protection function. |
| UoH | Overvoltage recovery value | 265V | 300V | 85V | This value must be smaller than overvoltage protection value. It will default to the overvoltage protection value -5V when you save. |
| SU | Overvoltage fault judgment time | 3s | 60s | 0.1s | It means the fault must be last how many times then it will make output load switch off when happen fault. |
| Io | Upper limit protection (water tower is full) | 5A | 63A | 1A | If the pump water real working current is higher than this, the product will switch off. |
| IL | Lower limit protection (no water or less water in the pipe) | 4A | 60A | 0.5A | If the pump water real working current is lower than this, the product will switch off. |
| SI | Current limit judgment time | 3s | 60s | 0.1s | It means the lower or upper limit must be last how many times then it will make output load switch off when current limit. |
| SH | Recycle working time setting for water pump after the product switch off protection | 60 | 999 | 1 | The unit is minute or hour which should be according to your select mode. |
Note: Under voltage protection value must be smaller than Overvoltage recovery value, or it will restore factory setting.
Water Pump Control System:
The device intelligently controls water pump operation. You can set a lower current limit (IL) and an upper current limit (Io) to determine when the water pump should turn on or off. For example, if the pump's working current drops below the lower limit (indicating no water in the pipe), the device can switch it off. If the current rises above the upper limit (indicating the water tower is full), it can also switch off the pump.
You can select between auto-reclosing mode (automatic restart after a fault) or manual-reclosing mode for pump operation.
Cycle Switch Mode:
The device supports cycle switch mode, allowing users to set fixed interval times for on and off cycles, configurable by minute or hour.
The device allows you to set a fixed interval time for the water pump's on and off cycles. This can be configured in minutes or hours, depending on the selected function mode (dE).
Electricity Measurement Display:
The display cycles through various parameters including Current (A), Voltage (V), Active energy (kWh), and Active power (P) via button presses.
In normal working mode, you can cycle through different measurement displays by pressing the Up (▲) or Down (▼) buttons. The available displays include Current (A), Voltage (V), Active energy (kWh), and Active power (P).
Product Video Overview:
An official product video demonstrating the features and functionality of the TOMZN DDS238-VAP-W protector.
5. Maintenance
- Placement: Do not place the device near flammable materials.
- Ventilation: Ensure adequate ventilation during operation to prevent overheating.
- Storage: Disconnect from power and store properly when not in use for extended periods. Store in a dry, cool place away from direct sunlight.
- Cleaning: Clean the device periodically with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Inspection: Regularly inspect wiring connections for tightness and signs of wear or damage.
6. Troubleshooting
- Device not powering on: Check the input voltage supply and ensure all wiring connections are secure. Verify the power indicator LED is lit.
- Protection trips frequently: Review your set overvoltage (Uo), overcurrent (Io), and undercurrent (IL) protection values. Ensure they are appropriate for your load.
- Water pump not operating as expected: Check the water pump control settings (dE, Io, IL, SH). Ensure the current thresholds are correctly set for your pump's operating conditions (e.g., dry pipe, full water tower).
- Incorrect voltage/current readings: Ensure the wiring is correct and secure. If the issue persists, the device may require professional inspection.
- Parameter setting issues: If the under-voltage protection value is set higher than the over-voltage recovery value, the device will revert to factory settings. Ensure UoH is always less than Uo.
If you encounter persistent issues that cannot be resolved with the above steps, please contact a qualified electrician or the manufacturer's support for assistance.
7. Specifications
General Specifications:
| Parameter | Value |
|---|---|
| Input working voltage | 85~300V AC |
| Overvoltage protection range | 85-300V (default 270V) |
| Overcurrent protection range | 1-63A (default 40A) |
| Rated frequency | 50/60Hz |
| Delay in switch on after power off | 2-255s (default 2s) |
| Voltage circuit power consumption | ≤1W |
| Current circuit power consumption | <1VA |
| Active energy display range | 0~9999.9kWh |
| Voltage/current/active power accuracy | 0.50% |
| Active energy accuracy | +1% (IEC62053-21) |
| Operating temperature | -25℃~+70℃ |
| Storage temperature | -40℃~+80℃ |
| Relative humidity | ≤85% |
| Altitude | ≤2500m |
| Electromagnetic Environment | E2 |
| Mechanical life | ≥100000 cycles |
Physical Dimensions:
Diagram showing the dimensions of the DDS238-VAP-W protector: 100mm (height), 49mm (width), 67.5mm (depth including terminals).
- Height: 100mm
- Width: 49mm
- Depth: 67.5mm (including terminals)
Certifications:
- Certification: CE
- EU LVD Voltage: High voltage: Above 50Vac or 75Vdc
- Applicable Regulations:
- Low Voltage Directive 2014/35/EU
- Electromagnetic compatibility Directive 2014/30/EU
- Restriction of the use of certain hazardous substances (RoHS) Directive 2011/65/EU
8. User Tips
Based on common user feedback and questions, here are some tips for optimal use:
- Professional Installation: Always ensure installation is carried out by a certified electrician to guarantee safety and correct functionality.
- Parameter Customization: Take time to understand and set the overvoltage, overcurrent, and water pump control parameters (Io, IL, SH) according to your specific application and equipment requirements. Default settings may not be ideal for all scenarios.
- Monitoring: Regularly check the LCD display for real-time voltage, current, and power readings to ensure your system is operating within safe limits.
- Water Pump Efficiency: Utilize the water pump control features to prevent dry running and overflow, which can significantly extend the life of your pump and conserve water.
- Backlight Mode: Adjust the backlight mode (b9) to suit your environment. Mode 2 (auto-off) can save energy if the device is in a frequently accessed area.
9. Warranty and Support
This product is manufactured by TOMZN and is designed for reliable performance. For any technical support, warranty claims, or service inquiries, please contact the seller or the official TOMZN support channels.
Please retain your purchase receipt as proof of purchase for warranty purposes.
For additional documentation, including the user manual in PDF format, please refer to the following link: User Manual (PDF)