1. Introduction
The PEAKMETER PM701 series EVSE adapters are professional tools designed for electric vehicle charging stations. These adapters offer broad compatibility with international standards such as SAE J1772, European Standard (Type 2), and NACS (Tesla). With comprehensive testing capabilities, exceptional safety features, and a robust design, these adapters can effectively simulate charging states, detect electrical faults, and provide instant feedback. Whether for installation, maintenance, or troubleshooting, the PM701 series is the ideal choice to ensure the safe and reliable operation of charging stations.
2. Safety Information
Always adhere to local electrical safety regulations and standards when using this device. Failure to do so may result in electric shock, fire, or damage to the equipment. This device is intended for use by qualified personnel only.
- Ensure the EVSE adapter is correctly connected to the charging station before performing any tests.
- Do not use the device if it appears damaged or if any part of the insulation is compromised.
- Avoid contact with live circuits.
- Always wear appropriate personal protective equipment (PPE) when working with electrical systems.
- The device contains a 10A/250V fuse. Ensure proper replacement if necessary.

3. Product Overview
The PEAKMETER PM701 series EVSE Adapter is a compact and rugged diagnostic tool. It features various input terminals, signal output points, and rotary switches for simulating different charging conditions.
3.1 Key Features
- NACS (Tesla) Standards Compatibility: Supports testing for Tesla charging stations.
- Pre-Testing Simulation: Includes PE (Protective Earth) and CP (Control Pilot) pre-testing functions.
- Error Simulation: Capable of simulating cable resistance, CP errors, and PE errors.
- Electrical Leakage Test: Performs leakage tripping tests (≥6mA/110V for PM701U and PM701UT).
- Rated IP54: Provides protection against dust and splashing water.
- Voltage System Support: Compatible with single-phase and three-phase voltage systems.
- Fuse Protection: Equipped with a 10A/250V fuse for safety.
- Current Simulation: Allows selection of various current levels (13A, 20A, 32A, 63A) and charging states (A, B, C, D).
3.2 Components and Controls

- Input Terminals: L1, L2, L3 (Phase Lines), N (Neutral), PE (Protective Earth) - for connecting external measurement devices.
- Signal Output: CP (Control Pilot), PE (Protective Earth) - for monitoring control signals.
- Touch Button: Activates specific test functions.
- PE Pre-Test Button: Initiates a pre-test for the Protective Earth circuit.
- CP Error 'E' Indicator: Lights up when a Control Pilot error is detected.
- PE Error Indicator: Lights up when a Protective Earth error is detected.
- Rotary Switches: Adjust settings for current simulation (13A, 20A, 32A, 63A, NC) and charging states (A, B, C, D).


4. Specifications
| Category | Feature | PM701U | PM701E | PM701UT |
|---|---|---|---|---|
| Test Functions | Test Object | AC charging station | ||
| Test Interface | SAE J1772 standard | Type2 (European Standard) | NACS (Tesla) | |
| Simulate Charging State | A, B, C or D | |||
| PE Pre-Testing | √ | |||
| CP Pre-Testing | √ | |||
| Simulate Cable Resistance | √ | |||
| Simulated CP Error | √ | |||
| Simulated PE Error | √ | |||
| Leakage Tripping Test | ≥6mA/110V | ≥6mA/110V | ||
| Charging Output Terminal | 4mm port/American standard socket | 4mm port/European standard socket | 4mm port/American standard socket | |
| Support Voltage Types | Single phase or three-phase | |||
| Indicator Light | √ | |||
| Fuse | 10A/250V | |||
| General | Protection Grade | Case IP54 | ||
| Safety Rating | IEC/EN 61010-1, IEC/EN61010-2-030, CAT Ⅲ 600V | |||
| Measurement Category | IEC/EN 61851-1, IEC/HD 60364-7-722 | |||
5. Setup
Before operating the EVSE Adapter, ensure the charging station is powered off or in a safe state for connection.
- Select the Correct Model: Choose the appropriate PM701 model (PM701U, PM701E, or PM701UT) based on the charging station's standard (SAE J1772, European Type 2, or NACS/Tesla).
- Connect to Charging Station: Plug the EVSE Adapter's charging connector into the charging station's outlet. Ensure a secure connection.
- Connect External Measurement Devices (Optional): If needed, connect external multimeters or oscilloscopes to the L1, L2, L3, N, PE, and CP signal output ports using 4mm banana plugs for detailed analysis.


6. Operating Instructions
The EVSE Adapter allows for various tests and simulations to diagnose AC charging stations.
6.1 Simulating Charging States (A, B, C, D)
Use the rotary switch labeled 'A', 'B', 'C', 'D' to simulate different charging states:
- State A: Vehicle not connected.
- State B: Vehicle connected, not ready to charge.
- State C: Vehicle connected, ready to charge.
- State D: Vehicle connected, charging with ventilation required (if applicable).
6.2 Current Simulation
Use the rotary switch labeled '13A', '20A', '32A', '63A', 'NC' to simulate different current capacities:
- Select the desired current limit to test the charging station's response to various vehicle current demands.
- 'NC' (No Connection) can be used to simulate an open circuit.
6.3 PE and CP Pre-Testing
- PE Pre-Test: Press the 'PE Pre-Test' button to verify the integrity of the Protective Earth circuit. Observe the 'PE Error' indicator.
- CP Pre-Test: The CP signal can be monitored via the 'CP' signal output terminal. The device simulates the CP signal for the charging station to detect.
6.4 Error Simulation
The adapter can simulate various fault conditions to test the charging station's safety mechanisms:
- Simulated CP Error: Activate the CP error simulation to check if the charging station correctly identifies and reacts to a fault in the Control Pilot circuit.
- Simulated PE Error: Activate the PE error simulation to check if the charging station correctly identifies and reacts to a fault in the Protective Earth circuit.
- Simulate Cable Resistance: This feature allows testing the charging station's response to varying cable resistance, which can affect charging performance and safety.
6.5 Leakage Tripping Test
For models PM701U and PM701UT, a leakage tripping test (≥6mA/110V) can be performed to verify the functionality of the charging station's residual current device (RCD) or ground fault circuit interrupter (GFCI).
7. Maintenance
Proper maintenance ensures the longevity and accuracy of your EVSE Adapter.
- Cleaning: Clean the device with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Storage: Store the adapter in a cool, dry place, away from direct sunlight and extreme temperatures. Use the provided carrying case for protection.
- Fuse Replacement: The device is protected by a 10A/250V fuse. If the fuse blows, replace it with a fuse of the same rating and type. Refer to the back panel for fuse access.
- Inspection: Regularly inspect the adapter cable and connectors for any signs of wear, damage, or corrosion.

8. Troubleshooting
If you encounter issues with your EVSE Adapter, refer to the following common problems and solutions:
- No Response from Charging Station:
- Ensure the adapter is securely connected to the charging station.
- Verify the charging station is powered on and functioning correctly.
- Check the selected charging state (A, B, C, D) and current simulation settings.
- Error Indicators (CP Error 'E', PE Error) Remain On:
- This indicates a detected fault. Perform PE and CP pre-tests.
- If simulating an error, ensure the charging station reacts as expected. If not, the charging station's safety mechanism may be faulty.
- Check for actual wiring faults in the charging station or its supply.
- No Power to External Measurement Devices:
- Ensure the 4mm ports are correctly connected.
- Check the internal fuse of the EVSE Adapter (10A/250V).
9. User Tips
- Localized Manuals: Some users have inquired about instructions in other languages, such as Spanish. Please check the manufacturer's website or contact support for availability of localized user manuals.
- Comprehensive Testing: Utilize the full range of simulation features (charging states, current levels, error simulations) to thoroughly test the charging station's behavior under various conditions.
10. Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the documentation provided with your purchase or contact PEAKMETER customer service. Keep your purchase receipt as proof of purchase.