1. Introduction
The Hanwei GTQ-BS series fixed gas detectors are designed for industrial and commercial applications to continuously monitor combustible gases and VOCs (Volatile Organic Compounds). These detectors feature high measurement accuracy, stable performance, and a long service life, ensuring reliable gas detection in various environments. This manual provides essential information for the safe and effective installation, operation, and maintenance of your GTQ-BS series gas detector.

2. Functional Features
- High Measurement Accuracy: Provides precise gas concentration readings.
- Stable Performance: Ensures consistent and reliable operation over time.
- Long Service Life: Designed for durability and extended use.
- Relay Output: Supports alarm and control integration.
- IP67 Protection Level: Offers robust protection against dust and water ingress, suitable for harsh industrial environments.
- Infrared Remote Control Operation: Allows for convenient calibration and one-key operation from a distance.
- Standard Sensor Module Design: Facilitates easy maintenance and sensor replacement.
- Standard 4-20mA Output and Switch Output: Compatible with various control systems.
- Optional Fire Bus Output Settings: For integration into fire safety systems.

3. Specifications
The GTQ-BS series includes several models with distinct features:
| Feature | GTQ-BS01 | GTQ-BS02 | GTQ-BS03 |
|---|---|---|---|
| Alarm Indication Method | Red/Yellow/Green three-color status indicator light | Wide temperature LED digital tube display, intuitive and clear | Wide temperature LCD liquid crystal display, intuitive and clear color backlight that changes with concentration |
| Relay Configuration | Supports 1-way passive relay output | Supports high/low alarm 2-way passive relay output and 1-way active output | Supports high/low alarm 2-way passive relay output and 1-way active output |
| Appearance Dimensions (L x W x H) | 130mm x 154mm x 83mm | 130mm x 154mm x 95mm | 130mm x 154mm x 95mm |

General Specifications:
- Power Supply: DC24V
- Output: 4-20mA, Relay Output
- Protection Rating: IP67
- DIY Supplies Category: Electrical
- Origin: Mainland China
- Certification: None specified
Package Contents:
- GTQ-BS Series Fixed Gas Detector (selected model)
- Mounting accessories (if applicable, not specified in data)
- User Manual (this document)
Package Dimensions:
- Length: 22 cm
- Width: 22 cm
- Height: 11 cm
- Weight: 2.0 kg
4. Setup and Installation
Proper installation is crucial for the accurate and safe operation of the gas detector. Ensure all local electrical codes and safety regulations are followed.
4.1 Mounting
- Select a mounting location where the target gas is most likely to accumulate. For gases lighter than air, mount near the ceiling. For gases heavier than air, mount closer to the floor.
- Ensure the detector is mounted securely to a stable surface, free from vibrations.
- Maintain adequate clearance around the detector for air circulation and maintenance access.
4.2 Electrical Connection
- The detector requires a DC24V power supply. Connect the power wires according to the wiring diagram (refer to product-specific wiring diagram if provided, not available in current data).
- Connect the 4-20mA output to your control system's analog input for continuous monitoring.
- Connect the relay output(s) to alarm devices, ventilation systems, or other control equipment as required.
- If using the optional fire bus output, connect it according to the fire safety system's specifications.
- Ensure all connections are tight and properly insulated to prevent short circuits and electrical hazards.
4.3 Initial Power-Up and Self-Test
- After all connections are made, apply DC24V power to the detector.
- The detector will perform a self-test sequence. Observe the indicator lights (GTQ-BS01) or display (GTQ-BS02/03) for any error messages.
- Allow the detector to warm up and stabilize for several minutes before proceeding with calibration or operation.
5. Operation
The GTQ-BS series detectors are designed for continuous monitoring. Once installed and powered, they will actively detect gas concentrations.
5.1 Gas Detection and Indication
- GTQ-BS01: Uses red, yellow, and green indicator lights to show status and alarm conditions. Consult the product's specific documentation for light patterns and their meanings.
- GTQ-BS02: Features a wide temperature LED digital tube display for clear and intuitive concentration readings.
- GTQ-BS03: Equipped with a wide temperature LCD liquid crystal display that shows concentration and features a color backlight that changes based on the detected gas concentration, providing a quick visual alert.
5.2 Remote Control Operation
The infrared remote control allows for convenient interaction with the detector without direct physical access, especially useful for units mounted in hard-to-reach areas.
- Calibration: The remote control can be used to initiate and perform calibration procedures.
- One-Key Operation: Specific functions, such as muting alarms or checking status, may be accessible via a single button press on the remote.
- Refer to the remote control's specific instructions for detailed button functions and operational modes.
6. Maintenance
Regular maintenance ensures the longevity and accuracy of your gas detector.
6.1 Routine Checks
- Visual Inspection: Periodically check the detector for any physical damage, corrosion, or blockages to the sensor opening.
- Function Test: Perform regular function tests using a known concentration of the target gas to verify alarm activation and output signals.
- Cleaning: Keep the detector's exterior clean. Use a soft, damp cloth. Do not use abrasive cleaners or solvents.
6.2 Calibration
Calibration is essential to maintain the accuracy of the gas detector. The frequency of calibration depends on environmental conditions and regulatory requirements.
- Use certified calibration gas and follow the manufacturer's recommended calibration procedure, often performed via the infrared remote control.
- Record all calibration dates and results.
6.3 Sensor Replacement
The GTQ-BS series features a standard sensor module design, allowing for easier sensor replacement when necessary (e.g., at the end of sensor life or if a sensor fails).
- Only use genuine replacement sensors from Hanwei or authorized distributors.
- Follow the specific sensor replacement instructions provided with the replacement module.
- After replacing a sensor, recalibrate the detector.
7. Troubleshooting
If your gas detector is not functioning as expected, refer to the following common issues and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| No power/display | Incorrect power connection, power supply failure | Check DC24V power supply and wiring. Ensure connections are secure. |
| Inaccurate readings | Sensor drift, sensor contamination, incorrect calibration | Perform a fresh calibration. Clean the sensor area. Consider sensor replacement if issues persist. |
| No alarm activation | Relay wiring issue, alarm threshold incorrect, sensor failure | Verify relay connections. Check alarm threshold settings. Perform a function test with gas. |
| Remote control not responding | Obstruction, battery low, remote control fault | Ensure clear line of sight. Replace remote control batteries. Contact support if still unresponsive. |
If the problem persists after attempting these solutions, contact Hanwei technical support or your local distributor for assistance.
8. User Tips
- Regular Testing: Even with stable performance, periodic testing with calibration gas is the best way to ensure your detector is working correctly.
- Environmental Considerations: Avoid installing the detector in areas with extreme temperatures, high humidity, or direct exposure to chemicals that could damage the sensor.
- Documentation: Keep a log of all maintenance activities, including calibration dates, sensor replacements, and any troubleshooting steps taken.
9. Warranty and Support
For warranty information, technical support, or service inquiries, please contact the manufacturer, Hanwei, or your authorized dealer. Ensure you have your product model and serial number available when contacting support.
For specific models and any further questions, please refer to the official Hanwei documentation or contact their customer service.