OUKITEL P1500 PLUS

Contents

OUKITEL P1500 PLUS Portable Power Station User Manual

Model: P1500 PLUS

1. Introduction to the Product

Thank you for purchasing the OUKITEL P1500 PLUS Portable Power Station. This product is a versatile portable power station, ideal for home emergency backup, outdoor camping, RV use, and various other applications. It features a built-in LiFePO4 battery that can be quickly charged via AC or solar panels. With its integrated UPS function, the station automatically switches to battery power in less than 10ms during a power outage, ensuring uninterrupted operation for connected devices.

The AC output generates a pure sine wave, and the frequency can be manually switched between 50 Hz and 60 Hz, providing safe operation for connected electrical appliances. Please read this instruction manual thoroughly before using the product to ensure proper operation. Keep this manual in a safe place for future reference. Improper use may result in serious injury to the user or others, and damage to the product or property.

By using this product, you acknowledge, understand, and accept all terms and conditions outlined in this manual. The user is responsible for their actions and any consequences that may arise. Our company is not liable for any damages resulting from product use inconsistent with this instruction manual. To ensure compliance with applicable laws, the company reserves the right to the final interpretation of this document and all related documents.

2. Safety Precautions

  • Avoid exposing the product to high temperatures, humidity, direct sunlight, or fire.
  • Do not disassemble or modify the product, as this may cause malfunction or even fire.
  • Dispose of or recycle the product in accordance with local regulations.
  • Be careful not to drop the product from a height or subject it to strong impacts.
  • Store and use the product out of reach of children.
  • Only use original accessories from the company. Customers using non-original products, and incurring losses as a result, will forfeit their right to free maintenance.
  • Do not block the ventilation openings during product use. Maintain at least 30 cm of clear space around the side intake and exhaust vents.
  • When the product is not in use, turn it off and disconnect it from the power supply. Avoid storing the product in areas with high temperatures, high humidity, or direct sunlight.
  • If the product is to be stored for an extended period, fully discharge it once every 3 months, then recharge it to at least 50%.
  • If you suspect the product, auxiliary cable, or connected equipment is damaged, stop using the product and contact customer service for assistance.
  • Do not store the product for extended periods in a car, field storage, or other places exposed to extreme temperatures, as this may shorten battery life and cause other malfunctions.
  • Medical Equipment Restrictions: This product is not intended to power medical equipment, including respirators (hospital CPE) or artificial lungs (ECMO - extracorporeal membrane oxygenation). Before using the product to power other medical devices, ensure there are no restrictions on using an external power source by consulting the manufacturer.
  • Power devices can generate electromagnetic fields that may interfere with the normal operation of medical implants such as pacemakers, cochlear implants, hearing aids, defibrillators, and other personal medical devices. If you use these medical devices, contact us regarding usage restrictions for this product. Basic precautions include maintaining sufficient distance from medical implants.

3. What's in the Box

Upon unpacking your OUKITEL P1500 PLUS, please ensure all items are present and in good condition:

  • Portable Power Station (P1500 PLUS)
  • AC Charging Cable
  • User Manual
  • Warranty Card
OUKITEL P1500 PLUS Portable Power Station
Portable Power Station
AC Charging Cable icon
AC Charging Cable
User Manual and Warranty Card icon
User Manual & Warranty Card

4. Product Overview

The OUKITEL P1500 PLUS is designed for ease of use and portability, featuring a robust design and intuitive controls.

4.1. Component Identification

Diagram of OUKITEL P1500 PLUS front panel with numbered parts
Front Panel Layout
Diagram of OUKITEL P1500 PLUS side and back panels with numbered parts
Side and Back Panel Layout
No. Component No. Component
1Power Button11DC Output (12 V)
2DC Button12Silent Mode
3AC Button13Fast Charging Mode
4LED Light Button14Slow Charging Mode
5LED Light15Overload Indicator
6LCD Screen16USB-A Outputs
7DC5521 Socket17USB-C Outputs
8Car Cigarette Lighter Socket18AC Outputs
9USB-A / USB-C Ports19Frequency Switch (50/60 Hz)
10AC Output Socket20WIFI / Bluetooth Indicator
AC Charging Socket / Overload Protection Button
External Grounding Terminal
PV / DC Input Socket
Cooling Air Inlet / Outlet

5. Initial Setup

5.1. First Use and Initial Charging

To ensure product safety during transport, the power station is charged to approximately 30% at the time of packaging. It is essential to charge it immediately after opening the package and before its first use.

  1. Unpack the OUKITEL P1500 PLUS and all accessories.
  2. Connect the provided AC charging cable to the AC charging socket on the power station.
  3. Plug the other end of the AC charging cable into a standard wall outlet.
  4. The LCD screen will light up, indicating that charging has begun. Charge the unit to 100% before first use.

Important: Avoid using extension cords or power strips. The product should be charged directly from a wall outlet. Do not connect devices to the station while it is being charged.

6. Operating Instructions

6.1. Power On/Off

To turn on the system and LCD display, press and hold the Power Button (1) for 3 seconds. To turn off the system, press and hold the Power Button for another 3 seconds.

6.2. DC Output Operation

After turning on the device, briefly press the DC Button (2) to activate the DC output port. Another short press will turn off this port.

6.3. AC Output Operation

The AC switch controls 4 AC output ports. The total load of connected devices should not exceed 1800W.

To activate the AC output ports, briefly press the AC Button (3) after turning on the device. Another short press will turn off the AC output. The AC output voltage and frequency vary by country. Check your equipment's parameters before use. To switch the frequency between 50 Hz and 60 Hz, press and hold the AC and LED buttons simultaneously for 3 seconds.

6.4. LED Light Operation

After turning on the device, a short press of the LED Light Button (4) activates continuous light mode. Subsequent short presses cycle through SOS mode and flashing mode. A long press of the LED button activates silent mode. Another long press will turn off silent mode.

6.5. LCD Screen Display

The LCD screen (6) displays the current power status and operating parameters of the device. Refer to the table below for icon descriptions.

Icon Description
Fan iconFan operating mode.
Temperature warning iconHigh/Low Temperature Warning: If this icon flashes, the internal temperature is too high or too low. The intelligent protection program will activate, and normal device operation will be suspended. Wait for the internal temperature to return to normal before restarting.
Charging error iconCharging Port Malfunction: If this icon flashes, it indicates improper operation of the charging port.
Output error iconOutput Malfunction: If this icon flashes, it indicates improper operation of a specific output port. Check the load status.
Silent mode iconSilent Mode: If this icon flashes, the device is operating in silent mode.
DISCHARGE REMAININGRemaining discharge time.
INPUT WattsCurrent input power in Watts.
OUTPUT WattsCurrent output power in Watts.
UPSUPS mode indicator.
PV ChargingSolar (Photovoltaic) charging indicator.
Battery Level (%)Current battery charge level.
OverloadOverload warning indicator.

6.6. Charging the Power Station

The P1500 PLUS offers multiple charging methods:

AC Charging

To charge the device, use the standard AC power cable and connect it to the AC charging port. Before starting, ensure the voltage and frequency of the electrical grid match the device's requirements (200-240V, 50/60Hz). The P1500 PLUS supports 1200W AC fast charging, allowing it to reach 80% in 1 hour and 15 minutes.

OUKITEL P1500 PLUS charging via AC input
AC Charging: 1200W 80% Charge in 1 Hr 15 Mins

Solar Charging

The product can be charged directly using solar panels. With a 500W solar panel, the station can be fully charged in approximately 3.5-4 hours. The maximum solar input power is 500W, and the maximum input voltage must not exceed 50V. Exceeding this value may damage the device and void the warranty.

Note: The charging power from solar panels depends on weather conditions, time of year, and proper panel angle.

OUKITEL P1500 PLUS charging via solar panels
Solar Charging: Max. 500W Full Charge in 2 Hrs 40 Mins

Car Charging

The product can be charged using the car's cigarette lighter socket (accessory, referred to as ACC) with an ACC charging cable. Turn on the device, connect the ACC charging cable to the car's cigarette lighter socket and to the XT60 port on the side of the device, then start the car engine. The input power will appear on the product's LCD screen.

Note: Car charging should only be done with the engine running to avoid draining the car battery. Car charging typically occurs at a low power of 90-240W, resulting in long charging times (12V/8A or 24V/10A). For faster charging, AC power is recommended.

OUKITEL P1500 PLUS charging in a car
Car Charging: 12V/24V Full Charge in 12 Hrs/6 Hrs

6.7. UPS Mode (Uninterruptible Power Supply)

The product features a bypass mode that allows devices to be powered directly from the AC grid, bypassing the battery. In the event of a sudden AC power disconnection, the device automatically switches to battery power within 10ms, ensuring uninterrupted operation for connected loads.

Note: In UPS mode, the maximum current is 14A for Japanese and American sockets, and 10A for Chinese, British, European, and Korean sockets. If the current consumption exceeds the permissible level, the UPS icon will flash, indicating an overload. Simultaneously, the AC icon will turn off, and power will be disconnected.

OUKITEL P1500 PLUS providing UPS backup, showing a monitor turning on after a power outage
Seamless 1800W UPS <10ms: Ensures continuous power during outages.

6.8. Smart App Control

Enjoy remote control functionality without needing to manually operate the power station, whether you are at home or outdoors. The OUKITEL P1500 PLUS supports Wi-Fi and Bluetooth connectivity for smart app control.

Smartphone app controlling the OUKITEL P1500 PLUS
Smart App Control via Wi-Fi and Bluetooth

7. Maintenance

  • Storage: When not in use, turn off the product and disconnect it from the power supply. Avoid storing the product in areas with high temperatures, high humidity, or direct sunlight.
  • Long-term Storage: If the product is to be stored for an extended period, fully discharge it once every 3 months, then recharge it to at least 50% to maintain battery health.
  • Ventilation: Ensure the cooling air inlets and outlets are not blocked during operation. Maintain at least 30 cm of clear space around them to prevent overheating.
  • Cleaning: Use a dry, soft cloth to clean the exterior of the power station. Do not use abrasive cleaners or solvents.

8. Troubleshooting

8.1. Common Issues and Indicators

  • Temperature Warning: If the temperature warning icon flashes, the internal temperature is too high or too low. The intelligent protection program will activate, and normal device operation will be suspended. Wait for the internal temperature to return to normal before restarting. Ensure ventilation openings are clear.
  • Charging Port Malfunction: If the charging error icon flashes, it indicates improper operation of the charging port. Check the charging cable and power source.
  • Output Malfunction: If an output malfunction icon flashes, it indicates improper operation of a specific output port. Check the connected load and ensure it is within the power station's limits.
  • Overload Protection: In case of unstable power supply (e.g., due to lightning) or excessively high AC input voltage, the built-in automatic fuse will activate the overload protection function, disconnecting the AC input port from the grid. To restore AC input operation:
    1. Turn off the power button and disconnect all devices connected to the ports.
    2. Once the power supply is stable, turn on the power button.
    3. Press the overload protection button and reconnect the AC cable to restore power.

If the problem persists after following these steps, please contact customer support.

9. Specifications

Feature Specification
Product NameP1500EPLUS
Dimensions (L*W*H)346 x 228 x 251 mm
Weight14.2 kg
Battery Capacity1536 Wh (51.2V) / 480000mAh (3.2V)
Battery TypeLiFePO4
Cycle Life (80% DoD)>3500 cycles
InverterPure Sine Wave
Rated Power1800W
Surge Power3600W
AC Output Voltage220-240Vac
Rated Frequency60Hz/50Hz (Switchable)
AC Charging Input200-240V, MAX 1200W (EU)
AC Charging TimeLess than 1.5 hours (to 80%)
PV Input (Solar)12-50V, 11A, MAX 500W (XT60 Port)
Solar Charging TimeApprox. 3 hours (with 500W panel)
Car Charging Input12V/8A or 24V/10A
AC Output Ports4 ports, 1800W total
USB-A Output2 x QC3.0 (5-12V, 18W)
USB Type-C Output1 x 20W (5-12V), 1 x PD100W (5-20V/5.0A)
DC5521 Output2 x 12V/3A socket
Cigar Lighter Port1 x 12V/10A socket
LED Lighting5W LED
UPS Rated Power220-240 Vac / MAX 10 A (EU)
UPS Switchover Time<10ms
Charging Temperature0-40℃ / 32-104℉
Discharging Temperature-10-40℃ / -4-104℉
Operating Humidity10% to 90%
Cooling Strategy2 Fans
ProtectionVoltage, Over-load, Over-temperature, Over-charge
Shell MaterialABS+PC (Fire rating: VO)
CertificatesCE, FCC, PSE, UN38.3, EMC, LVD, RoHS, MSDS
Infographic summarizing key features of OUKITEL P1500 PLUS
Key Features Overview: Ultra-quiet, Compact Size, 4000 Cycle LiFePO4, 1536Wh Battery, 1800W Output, Smart App Control, 1800W UPS, 1200W AC Fast Charging, 500W Solar Input.

10. User Tips

  • Air Conditioner Use: The OUKITEL P1500 PLUS has been reported by users to successfully power an air conditioner on a low setting for approximately 3 hours. This indicates its capability for handling moderate power demands for essential appliances during emergencies or off-grid situations.
  • Initial Charge: Many units arrive partially charged. It is recommended to fully charge the power station upon receipt before its first use to optimize battery performance and longevity.
  • Versatile Outputs: Take advantage of the numerous output ports (AC, USB-A, USB-C, DC5521, car cigarette lighter) to power a wide range of devices simultaneously.

11. Frequently Asked Questions (FAQ)

Q: What type of battery does the OUKITEL P1500 PLUS use?
A: It uses a LiFePO4 (Lithium Iron Phosphate) battery, known for its safety, long cycle life, and thermal stability.
Q: How long does it take to charge the power station?
A: Via AC input, it can charge to 80% in less than 1.5 hours. With a 500W solar panel, a full charge takes approximately 3 hours.
Q: Can I power an air conditioner with this unit?
A: Yes, users have reported successfully powering an air conditioner on a low setting for several hours. Ensure the appliance's power consumption is within the 1800W rated output.
Q: What is the maximum output power?
A: The OUKITEL P1500 PLUS has a rated output of 1800W and a surge power capability of 3600W.
Q: Does it have UPS (Uninterruptible Power Supply) functionality?
A: Yes, it features a seamless UPS function with a switchover time of less than 10ms, providing continuous power during outages.
Q: Can I charge and discharge the power station simultaneously?
A: Yes, the OUKIT0EL P1500 PLUS supports simultaneous charging and discharging.

12. Warranty and Support

The OUKITEL P1500 PLUS Portable Power Station comes with a 2-year warranty. Please retain your purchase invoice and the warranty card included in the package, as these documents are required for any potential product returns or warranty claims.

For technical support, troubleshooting assistance, or warranty service, please contact the seller or authorized service center. Do not attempt to repair the device yourself, as this will void the warranty and may cause further damage or injury.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.