1. Introduction
The ATORCH T3 is a versatile and high-precision digital USB tester designed for Type-C devices. It offers comprehensive measurement capabilities including voltage, current, power, capacity, energy, and advanced features like ripple curve analysis, music spectrum display, noise decibel metering, and environmental sensing (level, barometer, altimeter). With its intuitive touch control and gravity-sensing auto-rotate screen, the T3 provides an efficient and user-friendly experience for testing and monitoring various digital devices and chargers.
2. Package Contents
Please check the package contents upon receipt. If any items are missing or damaged, please contact customer support.
- ATORCH T3 Tester (Orange or Black, depending on SKU)
- Outer Color Box
- Storage Metal Box
- Measuring Line Resistance Adaptor Load Device
- T3 Product Manual
- Certificate of Conformity
- Touch Screen Pen (for "Full Sent" SKU)
- Random Computer Connection Cable (for "Full Sent" SKU)
3. Setup
3.1 Initial Connection
Connect the T3 USB Tester to a Type-C port of your device (e.g., phone, laptop) or a charger. Ensure a stable connection for accurate measurements.
3.2 APP Installation (Optional)
For advanced features and PC connectivity, you can install the companion APP.
- **iOS APP**: Search for "E_test" on the Apple App Store.
- **Android APP**: Search for "E-test" on Google Play or download directly from: https://www.mediafire.com/file/0jiio43c0vuu1wx/U_Meter-Phone_mobile.apk/file
Important Note for Android Users:
Some mobile phones may not be compatible with the APP from Google Play. If you encounter compatibility issues, please use the provided mediafire link. For Samsung mobile phones, please install and test the APP. When using the APP online, ensure GPS positioning permission and Bluetooth function are enabled on your mobile device.
3.3 PC Software (Optional)
The PC software supports Windows 7 and Windows 10 systems. It enables remote wireless control and measurement functions via Bluetooth BLE. Download URL: en.atorch.cn
4. Operating Instructions
4.1 Basic Operation
- **Zero Key**:
- Click: Loop to switch between main function interface and other function interfaces.
- Long press: On the interface displaying cumulative data, you can reset the cumulative data with just one click.
- **Screen Off Key**:
- Long press: Close the screen.
- Click: Adjust screen brightness.
- **Touch Screen Operation**:
- Swipe up and down: Browse page content.
- Swipe left and right: Switch between the main display item and other display items.
- Double click on the number area in the upper right corner of the screen on the homepage: Switch between large font display mode and 7-digit high-precision measurement interface.
- Click on the number box on some pages: An input keyboard will pop up, allowing you to manually set parameters.
4.2 Measurement Functions
The T3 USB Tester provides a wide range of measurement capabilities:
- **Voltage, Current, Power, Capacity, Energy**: Real-time display and recording of essential charging parameters.
- **Ripple Curve Analysis**: Supports three display functions: current voltage curve, D+D- curve, and power ripple curve, allowing intuitive analysis of fluctuation status during charging.
- **D+D- Detection**: Measures D+ and D- voltages for data line quality assessment.
- **Line Resistance Measurement**: Evaluate cable quality by measuring line resistance, especially when used with a line resistance load tester.
- **Battery Capacity Calculation**: Automatically calculates and records battery capacity, with power-off memory.
- **Music Spectrum Analyzer**: Built-in sound field pickup microphone allows for visual appreciation of music spectrum.
- **Noise Decibel Meter**: High-sensitivity condenser microphone for decibel measurement, helping to assess environmental noise levels.
- **Environmental Sensors**: Includes a level gauge, barometer, and altimeter for measuring current pressure and altitude.
4.3 Gravity Sensor and Screen Rotation
The built-in three-axis gravity acceleration sensor allows the screen to automatically rotate in four directions (0°/90°/180°/270°), ensuring the display is always oriented correctly for easy reading from any angle.
4.4 Bidirectional Current Detection
The T3 supports bidirectional current measurement, allowing connection in series to either the charger or the device for testing. It features an automatic zero reset function for no-load current, improving accuracy for small current measurements.
4.5 Data Recording and Power-off Memory
The T3 automatically records maximum voltage, current, and power, as well as real-time average values during charging. It retains data even after power-off, allowing for cumulative capacity statistics without starting from scratch. Accumulated data can also be manually cleared.
4.6 Mini Game
The T3 includes a "Bubble Poke Fun" mini-game for entertainment during leisure time, providing a fun way to relieve stress.
5. Maintenance
- **Cleaning**: Use a soft, dry cloth to clean the device. Avoid using harsh chemicals or abrasive materials.
- **Storage**: Store the device in its metal storage box in a cool, dry place when not in use to protect it from dust and physical damage.
- **Screen Care**: The 2.5D curved edge tempered glass touch panel is scratch and wear-resistant. However, avoid contact with sharp objects to maintain its integrity.
6. Troubleshooting
- **Device not turning on**: Ensure the device is properly connected to a power source (charger or device).
- **Inaccurate readings**:
- Ensure all connections are secure.
- Perform a zero-current calibration if necessary (refer to operating instructions).
- Check the quality of the data cable being used, as poor cables can affect readings.
- **APP connectivity issues**:
- Verify Bluetooth is enabled on your phone/PC.
- Ensure GPS/location permissions are granted to the APP on Android devices.
- Try reinstalling the APP from the provided links if issues persist.
- **Screen unresponsive**: Try pressing the screen off key to adjust brightness or restart the device by disconnecting and reconnecting.
7. Specifications
| Feature | Detail |
|---|---|
| Product Name | Type-C tester |
| Product Model | T3 |
| Working Voltage | DC 4.5-50V |
| Working Current | 0-6A (short-term peak value 12A) |
| Power Consumption | <0.15W |
| Power Display | 0-600W |
| Sampling Resistance | 0.005R |
| Data Retention Period | TA=55C, 20 years |
| Energy Range | 0-99999Wh |
| Capacity Range | 0-99999mAh |
| Working Temperature | -0-45°C / 32-113°F |
| Product Size | 53*39*13mm |
| Power Source | DC |
| Display Type | Digital Only |
| Accuracy Class | 1% (Software calibration technique) |
| Certification | CE |
| Origin | Mainland China |
8. User Tips
- **Cable Testing**: For accurate cable resistance measurements, ensure you use a dedicated line resistance load tester in conjunction with the T3.
- **Screen Brightness**: Adjust the screen brightness using a short press of the "Screen Off" key to conserve power or improve visibility in different lighting conditions.
- **Data Reset**: Long-press the "Zero Key" to reset cumulative data (mAh, Wh) when starting a new measurement session for a fresh reading.
- **Language Settings**: The device supports multiple languages. You can switch between them in the settings menu for a more comfortable user experience.
9. Support
For any questions, technical support, or issues with your ATORCH T3 USB Tester, please contact the seller or manufacturer directly. Refer to the product packaging or purchase platform for specific contact information.
The manufacturer ensures strict testing before shipping. If you have any questions when receiving and using the goods, please leave a message to contact us. We will actively solve your questions.