1. Product Introduction
The DATOUBOSS DT4862SQ is a 6.2KW 48V all-in-one hybrid solar inverter with a built-in 120A MPPT controller. It is designed for home on/off-grid solar systems, offering high efficiency, pure sine wave output, and remote monitoring capabilities.

1.1 Key Features
- High Efficiency: 98% DC/AC conversion efficiency minimizes energy loss, maximizing solar power generation.
- Smart Protection: Built-in multiple protections for battery, PV, and load safety.
- Remote Monitoring: WiFi/BMS support for real-time system status check via mobile APP.
- Wide Compatibility: Works with lead-acid and lithium batteries, with adjustable charging voltage.
- Pure Sine Wave Output: Compatible with all home appliances, ensuring no harmonic interference.
- Fast Charging: 120A max PV charging current for quick battery replenishment.
1.2 Core Functions
- Hybrid on/off-grid operation with UPS-level 10ms transfer time.
- 8500W max PV input with MPPT tracking range 60-500Vdc.
- 220/230/240VAC output with 50/60Hz auto-adaptive frequency.
- RS232 + WiFi + BMS communication for easy monitoring and management.
- 90-280VAC wide grid input range for stable operation under voltage fluctuations.
1.3 Application Scenarios
- Residential Houses: Ideal for villas, detached houses, providing self-generated power with surplus on-grid capabilities and UPS for power outage protection.
- Commercial Venues: Suitable for shops, offices, and supermarkets, offering cost control through PV direct supply and mains supplement, with UPS ports for critical equipment.
- Remote Areas: Enables independent power supply with off-grid mode and battery energy storage where mains supply is unstable. Battery-free mode can also be used with diesel generators for emergencies.
- Temporary Power: Perfect for construction sites and temporary offices, allowing easy installation of PV + mains power supply systems without high energy storage costs.
2. Safety Instructions
WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.
- Before using the unit, read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual.
- CAUTION: To reduce risk of injury, charge only deep-cycle lead-acid type rechargeable batteries. Other types of batteries may burst, causing personal injury and damage.
- Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
- To reduce risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
- CAUTION: Only qualified personnel can install this device with battery.
- NEVER charge a frozen battery.
- For optimum operation, follow required specifications to select appropriate cable size.
- Be very cautious when working with metal tools on or around batteries to avoid short circuits or explosions.
- Strictly follow installation procedures when disconnecting AC or DC terminals.
- One piece of 150A fuse is provided as over-current protection for the battery supply.
- GROUNDING INSTRUCTIONS: This inverter/charger should be connected to a permanent grounded wiring system. Comply with local requirements and regulations.
- NEVER cause AC output and DC input short circuits. Do NOT connect to the mains when DC input short circuits.
- Warning: Only qualified service persons are able to service this device. If errors still persist after following troubleshooting table, please send this inverter/charger back to local dealer or service center for maintenance.
3. Setup
3.1 Unpacking and Inspection
Before installation, inspect the unit to ensure nothing inside the package is damaged. The package should contain:
- The inverter unit x 1
- User manual x 1
- Wall Mounting Bracket & Screws x 1 set
- (Parallel communication cable is optional, included in parallel kits.)

3.2 Preparation
Before connecting any components, remove the bottom cover of the inverter by removing two screws.
3.3 Mounting the Unit
Consider the following points when selecting the installation location:
- Do not mount the inverter on flammable construction materials.
- Mount on a solid surface.
- Install this inverter at eye level to allow the LCD display to be read at all times.
- For proper air circulation to dissipate heat, allow a clearance of approximately 20 cm to the sides and 50 cm above and below the unit.
- The ambient temperature should be within the range of 20~35°C for optimal operation.
- The recommended installation position is to adhere to the wall vertically.
- Ensure sufficient heat dissipation and space for removing wires.
SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.
Install the unit by screwing three screws using M6*80mm expansion bolts.

3.4 Battery Connection
CAUTION: For safety and regulation compliance, install a separate DC over-current protector or disconnect device between the battery and inverter.
WARNING: All wiring must be performed by qualified personnel. Use appropriate cable for battery connection to reduce risk of injury.
Recommended battery cable and terminal size:
| Rated Capacity | Typical Amperage | Battery capacity | Wire Size (mm²) | Torque value |
|---|---|---|---|---|
| 2KVA | 165A | 200AH | 2*4AWG | 5Nm |
| 3.6KVA | 138A | 200AH | 2*4AWG | 5Nm |
| 6.2KVA | 128A | 200AH | 2*4AWG | 5Nm |
| 11KVA | 228A | 250AH | 1*3/0AWG | 5Nm |
Steps for battery connection:
- Assemble battery ring terminal based on recommended battery cable and terminal size.
- Insert the battery wires flatly into battery connectors of inverter and make sure the bolts are tightened with a torque of 2 Nm in a clockwise direction.
- Ensure polarity at both the battery and the inverter/charger is correctly connected and conductors are tightly screwed into the battery terminals.
3.5 AC Input/Output Connection
CAUTION: Before connecting to AC input power source, install a separate AC breaker between the inverter and AC input power source. This will ensure the inverter can be disconnected during maintenance and fully protected from over-current of AC input. The recommended spec of breaker is 32A for 24V system and 63A for 48V system.
CAUTION: There are two terminal blocks with "IN" and "OUT" markings. Do NOT mis-connect input and output connectors.
WARNING: All wiring must be performed by qualified personnel. Use appropriate cable for AC input connection to reduce risk of injury.
Suggested cable requirement for AC wires:
| Rated Capacity | Gauge | Torque value |
|---|---|---|
| 2KVA | 14AWG | 0.8~1.0Nm |
| 3.6KVA | 12AWG | 1.2~1.6Nm |
| 6.2KVA | 10AWG | 1.4~1.6Nm |
| 11KVA | 8AWG | 1.4~1.6Nm |
Steps to implement AC input/output connection:
- Before making AC input/output connection, ensure the DC protector or disconnector is open first.
- Remove insulation sleeve 10mm for six conductors. Shorten phase L and neutral conductor N by 3mm.
- Insert AC input wires according to polarities indicated on the terminal block and tighten the terminal screws. Ensure to connect the PE protective conductor(+) first.
- WARNING: Ensure that the AC power source is disconnected before attempting to hardwire it to the unit.
- Make sure the wires are securely connected.
3.6 PV Connection (Solar Charger Model Only)
CAUTION: Before connecting to PV modules, install a separate DC circuit breaker between the inverter and PV modules.
WARNING: All wiring must be performed by qualified personnel. Use appropriate cable for PV module connection to reduce risk of injury.
Typical Amperage and Gauge for PV wires:
| Typical Amperage | Gauge | Torque Value |
|---|---|---|
| 30A | 12AWG | 1.4~1.6Nm |
PV module selection considerations:
- The open circuit voltage (Voc) of the PV modules must not exceed the maximum PV array open circuit voltage of the inverter.
- The maximum supply voltage of the PV modules should be close to the optimal PV access voltage range of the inverter for best performance.
- If one PV module cannot meet this requirement, connect multiple PV modules in series.
Steps to implement PV module connection:
- Remove insulation sleeve 10 mm for positive and negative conductors.
- Suggest putting bootlace ferrules on the end of positive and negative wires with a proper crimping tool.
- Fix wire cover to the inverter with supplied screws.
- Check correct polarity of wire from PV modules and PV input connectors. Connect positive pole(+) of connection wire to positive pole(+) of PV input connector. Connect negative pole (-)of connection wire to negative pole(-) of PV input connector. Screw two wires tightly in clockwise direction.
3.7 CT Operation Guide
With a CT connected, the hybrid inverter can be easily integrated into an existing household system to arrange self-consumption via CT to control power generation and battery charging.
Single commissioning steps:
- Power off the inverter and connect the external CT using the tool accessory to install on the spring terminal block. Note that the mark of current flow direction on the CT should point to the Inverter and the polarity on connecting CT wires on the terminal block should be followed as "L+" VS red wire and "L-" VS black wire.
- Power on the inverter.
- Enter LCD setting on the inverter with CT sensor connected and set CT function to "PEC".
3.8 Final Assembly
After connecting all wirings, put the bottom cover back by screwing the two screws.
4. Operation
4.1 Power ON/OFF
Once the unit is properly installed and batteries are connected, simply press the On/Off switch (located on the button of the case) to turn on the unit.
Steps to Start Up:
Connect the battery (voltage needs to be beyond 23V) or AC (AC needs to confirm the suitable input range depending on the output mode), then you can start up the inverter.
- Mains power on: Connect to normal AC power, press the switch. The system will automatically turn on. If AC output power priority is set, after a period of time, the panel will display AC mode, indicating successful power-on and entry into AC mode.
- Battery boot: Connect to battery, press the power-on button to establish a working power source. The system will automatically turn on. After a period of time, the panel will display battery mode, indicating successful power-on and entry into battery mode.
Shutdown Steps:
When the system is in battery mode or AC mode output, press the switch again to turn off the system.
4.2 Operation and Display Panel
The operation and display panel on the front of the inverter includes three indicators, four function keys, and an LCD display, indicating the operating status and input/output power information.
LED Indicator Messages:
| LED Indicator | State | Messages |
|---|---|---|
| AC/INV (Green) | Solid On | Output is powered by utility in Line mode. |
| Flashing | Output is powered by battery or PV in battery mode. | |
| CHG (Yellow) | Solid On | Battery is fully charged. |
| Flashing | Battery is charging. | |
| FAULT (Red) | Solid On | Fault occurs in the inverter. |
| Flashing | Warning condition occurs in the inverter. |
Function Keys:
| Function Key | Description |
|---|---|
| ESC | To exit setting mode. |
| UP | To go to previous selection. |
| DOWN | To go to next selection. |
| ENTER | To confirm the selection in setting mode or enter setting mode. |
4.3 LCD Setting
After pressing and holding the ENTER button for 3 seconds, the unit will enter setting mode. Use the UP or DOWN buttons to select setting programs, then press ENTER to confirm or ESC to exit.
Operating Mode Descriptions:
| Operating mode | Behaviors | LCD display |
|---|---|---|
| Standby mode | No output power, solar or utility charger available | Battery is charged by utility. |
| Battery is charged by PV energy. | ||
| Battery is charged by utility and PV energy. | ||
| No charging. | ||
| Battery mode | Output power from battery or PV | PV energy and battery energy supply power to the load. |
| The PV energy powers the load and has remaining energy to charge the battery. | ||
| Battery provides power to the load. | ||
| Only PV mode | Output power from PV | PV provides power to the load. |
| Line mode | Output power from utility. Charger available | Utility charges battery and provides power to load. |
| PV energy, battery power and utility provide power to load. | ||
| If "PEC" is selected as output source priority, PV energy will support the output load with utility. | ||
| If "PEC" is selected as output source priority, Power from battery and utility. | ||
| If "SUF" is selected as output source priority, The remaining PV energy can be supplied to the grid. |
4.4 Battery Equalization Description
Equalization function reverses the buildup of negative chemical effects like stratification and helps remove sulfate crystals. It is recommended to equalize the battery periodically.
How to Apply Equalization Function:
You must enable battery equalization function in monitoring LCD setting program 30 first. Then, you may apply this function in device by either one of following methods:
- Setting equalization interval in program 35.
- Active equalization immediately in program 36.
When to Equalize:
In the stage, when the setting equalization interval (battery equalization cycle) is arrived, or equalization is active immediately, the controller will start to enter Equalize stage.
Equalize Charging Time and Timeout:
In Equalize stage, the controller will supply power to charge the battery until battery voltage raises to the battery equalization voltage. Then, constant-voltage regulation is applied to maintain battery voltage at the battery equalization voltage. The battery will remain in the Equalize stage until the setting battery equalized time is arrived.
5. Maintenance
Regular maintenance ensures the longevity and optimal performance of your DATOUBOSS Hybrid Solar Inverter. Always prioritize safety during any maintenance tasks.
- Regular Inspection: Periodically check all wiring connections for tightness and signs of wear or corrosion.
- Cleaning: Keep the inverter's ventilation openings clear of dust and debris to ensure proper airflow and prevent overheating. Use a soft, dry cloth for cleaning the exterior.
- Battery Health: Monitor battery voltage and performance regularly. Ensure batteries are not frozen and are of the recommended deep-cycle lead-acid type (or compatible lithium batteries).
- Firmware Updates: Check the manufacturer's website for any available firmware updates to ensure your inverter operates with the latest features and improvements.
- Professional Service: For any complex issues, internal repairs, or if errors persist after basic troubleshooting, contact a qualified service center or your local dealer. Do not attempt to disassemble the unit yourself.
6. Troubleshooting
6.1 Fault and Alarm Description
The inverter enters fault mode when the red LED light is always on and the LCD displays a fault code. An alarm condition is indicated by the red LED flashing and an alarm code on the LCD.
Alarm Indicator:
| Alarm Code | Alarm Event | Audible Alarm | Icon Flashing |
|---|---|---|---|
| A01 | Fan is locked when inverter is on. | Beep three times every second | A01 |
| A02 | Over temperature | None | A02 |
| A03 | Battery is over-charged | Beep once every second | A03 |
| A04 | Low battery | Beep once every second | A04 |
| A07 | Overload | Beep once every 0.5 second | A07 |
| A10 | Output power derating | Beep twice every 3 seconds | A10 |
| A15 | PV energy is low. | Beep twice every 3 seconds | A15 |
| A16 | High AC input (>280VAC) during BUS soft start | None | A16 |
| A27 | Max battery discharge current setting | None | A27 |
| E9 | Battery equalization | None | E9 |
| 6P | Battery is not connected | None | 6P |
Fault Reference Code:
| Fault Code | Fault Event | Icon on |
|---|---|---|
| F01 | Fan is locked when inverter is off. | ERROR |
| F02 | Over temperature or NTC is not connected well. | ERROR |
| F03 | Battery voltage is too high. | ERROR |
| F04 | Battery voltage is too low. | ERROR |
| F05 | Output short circuited or over temperature is detected by internal converter components. | F05 ERROR |
| F06 | Output voltage is too high. | F06 ERROR |
| F07 | Overload time out. | F07 ERROR |
| F08 | Bus voltage is too high. | F08 ERROR |
| F09 | Bus soft start failed. | F09 ERROR |
| F51 | Over current or surge. | F51 ERROR |
| F52 | Bus voltage is too low. | F52 ERROR |
| F53 | Inverter soft start failed. | F53 ERROR |
| F55 | Over DC voltage in AC output. | F55 ERROR |
| F57 | Current sensor failed. | F57 ERROR |
| F58 | Output voltage is too low. | F58 ERROR |
| F59 | PV voltage is over limitation. | F59 ERROR |
6.2 Trouble Removal
| Problem | LCD/LED/Buzzer | Explanation/Possible cause | What to do |
|---|---|---|---|
| Unit shuts down automatically during startup process. | LCD/LEDs and buzzer will be active for 3 seconds and then complete off. | The battery voltage is too low (<1.91V/Cell) | 1. Re-charge battery. 2. Replace battery. |
| No response after power on. | No indication. | 1. The battery voltage is far too low.(<1.4V/Cell) 2. Internal fuse tripped. | 1. Contact repair center for replacing the fuse. 2. Re-charge battery. 3. Replace battery. |
| Input voltage is displayed as 0 on the LCD and green LED is flashing. | Input protector is tripped. | Check if AC breaker is tripped and AC wiring is connected well. | |
| Mains exist but the unit works in battery mode. | Green LED is flashing. | Insufficient quality of AC power. (Shore or Generator) | 1. Check if AC wires are too thin and/or too long. 2. Check if generator (if applied) is working well or if input voltage range setting is correct. Change output source priority to Utility first. |
| Green LED is flashing. | Set "Solar First" as the priority of output source. | Check if battery wires are connected well. | |
| When the unit is turned on, internal relay is switched on and off repeatedly. | LCD display and LEDs are flashing. | Battery is disconnected. | Check if battery wires are connected well. |
| Buzzer beeps continuously and red LED is on. | Fault code 07 | Overload error. The inverter is overloaded 105% and time is up. | Reduce the connected load by switching off some equipment. |
| If PV input voltage is higher than specification, the output power will be derated. At this time, if connected loads is higher than derated output power, it will cause overload. | Reduce the number of PV modules in series or the connected load. | ||
| Fault code 05 | Output short circuited. | Check if wiring is connected well and remove abnormal load. | |
| Fault code 02 | Temperature internal converter component is over 120°C. | Check whether the air flow of the unit is blocked or whether the ambient temperature is too high. | |
| Fault code 03 | Battery is over-charged. The battery voltage is too high. | Check if spec and quantity of batteries are meet requirements. | |
| Fault code 01 | Fan fault | Replace the fan. | |
| Fault code 06/58 | Output abnormal (Inverter voltage below than 190Vac or is higher than 260Vac) | 1. Reduce the connected load. 2. Return to repair center. | |
| Fault code 08/09/53/57 | Internal components failed. | Return to repair center. | |
| Fault code 51 | Over current or surge. | Restart the unit, if the error happens again, please return to repair center. | |
| Fault code 55 | Bus voltage is too low. | ||
| Fault code 59 | PV input voltage is beyond the specification. | Reduce the number of PV modules in series. |
7. Specifications
7.1 Technical Datasheet (Model DT4862SQ)
| Parameter | Specification |
|---|---|
| Model | DT4862SQ |
| Input Sources | L+N+PE |
| Rated Input Voltage | 220/230/240VAC |
| Input Voltage Range | 90-280VAC±3V (APL Mode), 170-280VAC±3V (UPS Mode) |
| Frequency | 50Hz/60Hz (Auto Adaptive) |
| Rated Power | 6200W |
| Output Voltage | 220/230/240VAC±5% |
| Output Frequency | 50/60Hz±0.1% |
| Waveform | Pure Sine Wave |
| Peak Power | 12400VA |
| Overload capacity | Battery mode: 11s@105%~150% Load; 2s@150%~200% Load; 400ms@>200% Load |
| Nominal output current | 26.9A |
| Transfer Time (adjustable) | Computers (UPS Mode) 10ms, Appliance (APL Mode) 20ms |
| Maximum conversion efficiency (DC/AC) | 98% |
| Battery Voltage | 48Vdc |
| PV Charging Mode | MPPT |
| MAX.PV Input Power | 8500W |
| MPPT Tracking Range | 90~500Vdc |
| Best voltage | 360-430V |
| MAX.PV Input Voltage | 500Vdc |
| PV Max Input Current | 27A |
| MAX.PV Charging Current | 120A |
| MAX.AC Charging Current | 100A |
| MAX.Charging Current | 120A |
| Display | LCD interface |
| Interface | RS232, CAN display running mode/load/input/output, etc. |
| Extend the socket communication interface | Lithium Battery BMS Communication Card, WifiCard |
| Operating Temperature | -10~50℃ |
| Humidity | 20%~95% (Non-condensing) |
| Storage Temperature | -15~60°C |
| Altitude | Altitude Not Over 1000m, Derating over 1000m, Max 4000m, Refer to IEC62040 |
| Noise | ≤50db |
| Standards and certification | EN-IEC 60335-1, EN IEC 60335-2-29, IEC 62109-1 |
7.2 Product Properties
- Voltage: 50V AC / 75V DC and above
- High-concerned chemical: None
- Socket Type: Europe
- Conversion Efficiency: 0.9 (98% DC/AC)
- Rated Power: 6200W
- Output Frequency: 50Hz/60Hz
- Output Voltage: 220/230/240VAC±5%
- Input Voltage: 220V-250V
- Origin: Mainland China
- Certification: CE, FCC, RoHS, pse, weee
- Input Sources: L+N+PE
- Rated Input Voltage: 220/230/240VAC
- Communication: WiFi, RS232, BMS
- Efficiency: 98%
- Transfer Time: 10ms
- PV Input Power: 8500W
- Power Factor Range: >0.99
- Output Frequency: 50/60Hz±0.1%
- Battery Voltage: 48V, 48Vdc
- PV Max Input Current: 27A
- MAX.PV Charging Current: 120A
- MAX.AC Charging Current: 100A
- MAX.Charging Current: 120A
- Operating Temperature: -10~50℃
- Noise: ≤50db
- Size: 44.03*30.9*12.55cm
8. User Tips
- Cable Sizing: Always use the recommended cable sizes for battery, AC input/output, and PV connections to ensure safety and efficient operation. Undersized cables can lead to performance issues and safety hazards.
- Proper Ventilation: Ensure adequate clearance around the inverter (20cm sides, 50cm top/bottom) to prevent overheating, especially in warmer climates.
- Battery Compatibility: While the inverter supports both lead-acid and lithium batteries, ensure your battery type is correctly configured in the LCD settings for optimal charging and discharge cycles.
- Monitoring: Utilize the WiFi/BMS communication features to monitor your system's performance and battery status remotely. This helps in proactive troubleshooting and system optimization.
- Overload Prevention: Be mindful of the inverter's rated power and overload capacity. Avoid connecting too many inductive loads simultaneously to prevent overload shutdowns.
9. Frequently Asked Questions (FAQ)
Why do we choose Pure Sine Wave Inverter?
Pure sine wave inverters protect your electronic devices and provide reliable power. They produce very little EMI noise, which is important if you run line-level analog audio. Pure sine wave helps avoid damage to sensitive electronics such as computers, laptops, and sound systems. Modified sine wave inverters can damage electronics. This inverter provides a pure sine wave output.
Important Notes:
- Ensure the rated power is higher than the appliance you want to apply.
- If you want to run several devices at the same time, refer to the total wattage.
- If you want to use the inductive load for a long time, choose the Pure sine wave inverter.
- Use standard battery cables. Spare fuses in the package are for replacement only.
- Do not connect the inverter with the grid power and a reverse connection of positive and negative is also forbidden.
- Do not overload. If your applications are inductive loads, choose the inverter whose continuous power is 1.5-2 times higher than the watts of your appliances, such as fridge, freezer, dishwashing machine, water pump, microwave oven, vacuum cleaner, hair dryer, etc., with motor inside.
How to buy inverter SERVICE UPGRADE?
- Firstly, confirm your battery voltage and battery capacity.
- If your battery voltage is 12V, choose an inverter with a 12V battery. The battery voltage must be consistent with the inverter model. The larger the battery capacity, the greater the electrical power that can be driven. For example, how much power can the battery bring? 12V*60Ah battery = 720W electrical appliances.
- What electrical appliances should bring? Electrical appliances are divided into inductive load appliances and resistive load appliances.
- Resistive load appliances: computers, televisions, fans, lights and other household appliances.
- Inductive load appliances: refrigerators, washing machines, hand drills, air conditioners, water pumps, etc.
- The instantaneous power of inductive load electrical appliances is relatively large and has peak power, which is usually 3-10 times of its rated power.
- For example, for a 300W air conditioner, the starting power is generally 3-10 times and so an inverter with a peak power greater than 3000W is needed to bring it.
Attention! Although the power of LED bulb is very small, sometimes the inverter of 2200W can't drive, because LED or energy-saving bulb is divided into national standard and non-national standard bulb. The national standard bulb is basically a resistive load. Choose national standard bulb, so that the inverter can drive normally. The modified wave inverter with energy-saving lamps, LED lamps, induction cooker and welding machine may damage the inverter, so it is recommended pure sine wave power inverter.
10. Warranty and Support
For any service or repair needs, please contact a qualified service center or your local dealer. Do not attempt to disassemble the unit yourself, as this may void your warranty and pose safety risks.
For further assistance, you may refer to the official user manual PDF: DATOUBOSS Hybrid Solar Inverter User Manual (PDF)
You can also visit the DATOUBOSS website at www.datouboss.com or contact service via email at service@datouboss.com. For urgent inquiries, you may use Phone/Wechat/Whatsapp/LINE: +86 15903693872.