DATOUBOSS DT-48V6KW-BF-A

Contents

DATOUBOSS 6000W Solar Hybrid Inverter

Model: DT-48V6KW-BF-A

User Instruction Manual

1. Introduction

Thank you for choosing the DATOUBOSS 6000W Solar Hybrid Inverter. This device is a high-performance, pure sine wave inverter designed for reliable power conversion from 48V DC to 230V AC. Featuring an IP54 dustproof and water-resistant rating, it is suitable for various environments. With an impressive 8000W maximum PV input and support for battery-free operation, it offers flexibility for both on-grid and off-grid solar systems. This manual provides essential information for safe installation, operation, maintenance, and troubleshooting to ensure optimal performance and longevity of your inverter.

DATOUBOSS 6000W Solar Hybrid Inverter main unit
Figure 1: DATOUBOSS 6000W Solar Hybrid Inverter

2. Safety Information

Please read and understand all safety instructions before installing or operating the inverter. Failure to follow these instructions may result in electric shock, fire, serious injury, or death.

  • Installation must be performed by qualified personnel in accordance with all local electrical codes.
  • Ensure the inverter is disconnected from all power sources (PV, battery, AC grid) before performing any maintenance or wiring.
  • Do not disassemble the inverter. There are no user-serviceable parts inside.
  • Avoid exposing the inverter to rain, snow, or liquids, despite its IP54 rating, unless specifically designed for such direct exposure.
  • Ensure proper ventilation around the inverter to prevent overheating.
  • Use appropriate personal protective equipment (PPE) during installation and maintenance.
  • Keep children and unauthorized persons away from the inverter.

3. Product Overview

3.1. Components and Indicators

The following diagram illustrates the main components, ports, and indicators of the DATOUBOSS Solar Hybrid Inverter.

Detailed view of inverter components and ports
Figure 2: Detailed view of Inverter Components and Ports
  • Front Panel:
    • Battery Indicator: Shows battery charge status.
    • Fault Indicator: Illuminates to indicate system errors.
    • Utility/Inverter Indicator: Shows whether the inverter is operating on utility power or in inverter mode.
    • LCD Display: Provides real-time operational data and settings.
    • ESC Button: Exits current menu or setting.
    • UP Button: Navigates up in menus or increases values.
    • DOWN Button: Navigates down in menus or decreases values.
    • ENTER Button: Confirms selection or enters a menu.
  • Bottom Panel:
    • Parallel connection-CAN port: For connecting multiple inverters in parallel.
    • Switch: Main power switch.
    • PV input connection port: For connecting solar panel arrays.
    • Communication connection port: For external communication (e.g., monitoring).
    • Battery connection port: For connecting to the battery bank.
    • AC output/Generator port: For connecting to loads or a generator.
    • AC input port: For connecting to the utility grid.
    • Dry contact port: For external control signals.
  • Side Panels: Equipped with ventilation grilles for heat dissipation.

3.2. Key Features

  • High Power Output: 6000W nominal power with pure sine wave output.
  • High PV Input: Supports up to 8000W maximum PV input power.
  • Robust Design: IP54 dustproof and water-resistant for enhanced durability.
  • Battery Compatibility: Compatible with various 48V battery types including AGM, GEL, FLD, Li, SLD, and user-defined settings.
  • Battery-Free Operation: Capable of operating directly from PV and/or grid power without a battery bank.
  • Advanced BMS Communication: Supports RS485 / RS232 for Battery Management System (BMS) communication, including Growatt, Pylontech, and Voltronic protocols for lithium batteries.
  • Comprehensive Protection: Built-in 360° protection against overvoltage, short circuit, overcharge, over-discharge, temperature fluctuations, undervoltage, overload, and overcurrent.
  • Parallel Capability: Can be expanded up to 12 units for increased power output in single-phase configurations.
  • Smart Device Integration: Designed with smart features for enhanced control and monitoring.
Inverter features: 6000W Rated Output Power, 8000W Max PV Input Power, 230VAC 50/60Hz 26.1A AC Output
Figure 3: Key Power Specifications
Inverter compatibility with various 48V batteries and battery-free operation
Figure 4: Battery Compatibility and Battery-Free Mode
Inverter protection features: Overvoltage, Short circuit, Overcharge, Over-discharge, Temperature, Undervoltage, Overload, Overcurrent protection
Figure 5: Comprehensive 360° Protection

4. Specifications

Detailed technical specifications for the DATOUBOSS 6000W Solar Hybrid Inverter.

Feature Specification
Model NumberDT-48V6KW-BF-A
Brand NameDATOUBOSS
Nominal Power6000VA / 6000W
Output WaveformPure Sine Wave
Efficiency (Line Mode)> 95% @ rated load, full battery
Efficiency (Inverter Mode)Peak 93%
Surge Capacity2 X rated power for 5 seconds
DC Input Voltage48V DC
Max DC Input Current125A
DC Output Voltage60V (default 30A, Max 120A)
Cold Start Voltage46V DC
AC Output Voltage230V AC ± 5%
Output Frequency50Hz / 60Hz (selectable)
Max AC Output Current26.1A
Transfer Time (UPS Mode)10ms (single unit)
Transfer Time (APL Mode)20ms (single unit)
Transfer Time (Parallel)50ms
Max PV Input Power8000W
MPPT Voltage Range85-450V DC
Nominal PV Voltage300V DC
Max PV Input Current27A
Max PV Charging Current120A
AC Input Voltage230V AC, 50/60Hz
Max AC Charging Current50A
Input Voltage Range (UPS Mode)170-280V AC
Input Voltage Range (APL Mode)90-280V AC
BMS CommunicationRS485 / RS232 supported
Ingress ProtectionIP54 (dustproof water-resistant)
Operating Temperature-10 °C ~ + 55 °C
Storage Temperature-20 °C ~ + 70 °C
Battery-Free OperationSupported (grid/PV powered)
Parallel CapabilityUp to 12 units (single-phase)
Size34.7x44.5x12 cm
Weight13kg
CertificationCE
EU LVD VoltageBelow 50Vac or 75Vdc
Is Smart DeviceYes
OriginMainland China

5. Installation and Setup

Proper installation is crucial for the safe and efficient operation of your inverter. Refer to Figure 2 for port locations.

5.1. Mounting

  • The inverter is designed for wall-mounting. Choose a sturdy, vertical surface capable of supporting the inverter's weight (13kg).
  • Ensure the mounting location is well-ventilated, dry, and protected from direct sunlight and extreme temperatures.
  • Maintain adequate clearance around the inverter for proper airflow, especially around the side ventilation grilles.

5.2. Wiring Connections

All wiring should be done by a qualified electrician. Ensure all power sources are disconnected before making any connections.

  1. Battery Connection: Connect the 48V DC battery bank to the Battery connection port on the bottom panel. Observe correct polarity (positive to positive, negative to negative).
  2. PV Input Connection: Connect the solar panel array to the PV input connection port. Ensure the PV voltage and current are within the inverter's specified limits (Max PV Input Power 8000W, MPPT Voltage Range 85-450V DC, Max PV Input Current 27A).
  3. AC Input Connection: Connect the utility grid (230V AC, 50/60Hz) to the AC input port.
  4. AC Output/Generator Connection: Connect your AC loads or a backup generator to the AC output/Generator port.
  5. Communication Ports: If using, connect external communication devices (e.g., monitoring systems, BMS) to the Communication connection port (RS485 / RS232) and Parallel connection-CAN port as needed.
  6. Dry Contact Port: Connect any external control signals to the Dry contact port if required for your system setup.

5.3. Initial Configuration

  • Battery Type Selection: After powering on, use the UP/DOWN buttons to navigate the LCD menu and select the appropriate battery type (AGM, GEL, FLD, Li, SLD, USER) that matches your connected battery bank. For lithium batteries, select "User-defined" and configure the specific communication protocol (Growatt, Pylontech, Voltronic) if applicable.
  • Output Frequency: Select the desired output frequency (50Hz or 60Hz) via the LCD menu to match your local grid standards.
  • Battery-Free Mode: If operating without batteries, ensure this mode is correctly configured in the settings. The inverter can operate directly from grid and/or PV power.

6. Operation

Once installed and configured, the inverter will begin operation. Monitor the LCD display and indicators for system status.

  • Power On: Flip the main switch on the bottom panel to the 'ON' position. The LCD display will light up, and the inverter will initiate its startup sequence.
  • Monitoring: The LCD display provides real-time information such as input/output voltage, current, power, battery status, and operational mode. The Battery, Fault, and Utility/Inverter indicators provide quick visual status updates.
  • Menu Navigation: Use the ESC, UP, DOWN, and ENTER buttons to navigate through the LCD menu to view detailed information or adjust settings.
  • Operational Modes: The inverter automatically switches between different operational modes (e.g., Line Mode, Inverter Mode, UPS Mode, APL Mode) based on power availability and system configuration.

7. Maintenance

Regular maintenance ensures the longevity and optimal performance of your DATOUBOSS Solar Hybrid Inverter.

  • Cleaning: Periodically clean the exterior of the inverter with a dry, soft cloth. Do not use liquid cleaners or solvents.
  • Ventilation: Ensure that the ventilation openings on the side panels are free from dust, debris, or obstructions. Blocked vents can lead to overheating.
  • Connection Checks: Annually, or as needed, inspect all wiring connections (PV, battery, AC input/output) to ensure they are secure and free from corrosion. Tighten any loose connections.
  • Environmental Inspection: Check the inverter's surroundings for any signs of moisture, pests, or damage that could affect its operation.
  • Firmware Updates: Check the manufacturer's website for any available firmware updates to ensure your inverter has the latest features and bug fixes.

8. Troubleshooting

This section provides guidance on common issues. For complex problems, contact technical support.

Problem Possible Cause Solution
Inverter not turning on No DC input from battery/PV; Main switch off; Blown fuse. Check battery connections and voltage; Ensure PV input is sufficient; Turn main switch ON; Check and replace fuses if necessary.
No AC output Overload; Short circuit on output; Inverter in fault mode; Low battery voltage. Reduce load; Check for short circuits; Check fault indicator and LCD for error codes; Charge batteries or check battery connections.
Fault indicator lit Internal fault; Over-temperature; Over/under voltage. Check LCD for specific error code; Ensure proper ventilation; Verify input/output voltages are within range. If persistent, contact support.
Low efficiency Poor connections; Undersized wiring; Overheating. Check all connections for tightness and corrosion; Ensure wiring gauge is appropriate for current; Improve ventilation.

9. Warranty and Support

For warranty information, technical support, or service requests, please contact your DATOUBOSS dealer or the official DATOUBOSS customer service. Ensure you have your product model number (DT-48V6KW-BF-A) and serial number ready when contacting support.

© 2024 DATOUBOSS. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.