ASA NI-210G, NI-210SJ, NI-210SS

Contents

ASA VI Curve Tester Instruction Manual

Models: NI-210G, NI-210SJ, NI-210SS

1. Introduction

This manual provides detailed instructions for the setup, operation, and maintenance of your ASA VI Curve Tester. This device is designed for circuit board maintenance and fault diagnosis by displaying the V-I characteristics of electronic components on an oscilloscope. Please read this manual thoroughly before use to ensure safe and effective operation.

2. Important Safety Warnings

  • Prohibit Live Operation: Never connect the VI Curve Tester to a circuit board or component that is powered on. Always ensure the circuit under test is completely de-energized before making any connections. Failure to do so can result in damage to the tester, the circuit board, or personal injury.
  • Use the device only in a dry, indoor environment. Avoid exposure to moisture, rain, or direct sunlight.
  • Keep the device away from open flames, heaters, and other high-temperature sources.
  • Do not attempt to modify or disassemble the device. Unauthorized modifications will void the warranty and may lead to unsafe operation.
  • Ensure proper ventilation around the device during operation.
Front panel of the NI-210G VI Curve Tester with input terminals labeled A, COM, B and control buttons for voltage, frequency, channel, and scan.
Figure 1: Front panel of the NI-210G model, showing input terminals and control buttons. Note the warning: "Prohibit live operation!"

3. Product Models and Components

The ASA VI Curve Tester series includes several models, each with specific features. This manual covers the NI-210G, NI-210SJ, and NI-210SS models.

3.1 Model Overview

Comparison image showing three VI Curve Tester models: NI-210G, NI-210SJ, and NI-210SS, highlighting their different control layouts and features.
Figure 2: Overview of different VI Curve Tester models and their control panels.
  • NI-210G: Features a plastic shell, dual-channel display capability, and dedicated buttons for voltage (0.6V, 4V, 8V, 16V), frequency (60Hz, 400Hz, 2000Hz), channel selection (A, A+B), scan, and pulse functions.
  • NI-210SJ: Available in plastic shell or acrylic versions, featuring alternating display, voltage selection (LOW, MED1, MED2, HIGH), an impedance adjustment knob, an alternating switch, and channel inputs (A, B, G).
  • NI-210SS: Features a plastic shell, dual-channel display, voltage selection (LOW, MED1, MED2, HIGH), an impedance adjustment knob, an alternating switch, and channel inputs (A, B, G).

3.2 Included Components

Your VI Curve Tester package typically includes:

  • VI Curve Tester Unit (specific model)
  • Power Adapter (DC 24V, not always included, check product listing)
  • Test Leads (Red, Black, Blue)
  • Optional: VI Test Board for component testing (see Figure 3)
A small circuit board labeled 'VI test board' with various component symbols and sockets for testing transistors, diodes, resistors, and capacitors.
Figure 3: Optional VI Test Board for individual component testing.

4. Setup Instructions

  1. Power Connection: Connect a DC 24V power adapter to the power input jack on the VI Curve Tester.
  2. Oscilloscope Connection: Connect the two BNC output connectors on the top of the VI Curve Tester to the X and Y input channels of your oscilloscope. Set the oscilloscope to X-Y mode.
  3. Test Lead Connection: Connect the red test lead to the 'A' terminal, the black test lead to the 'COM' terminal, and the blue test lead to the 'B' or 'G' terminal (depending on model and test requirement).
  4. Prepare Circuit Board: Ensure the circuit board or component you intend to test is completely de-energized and disconnected from any power source.
  5. Connect to Test Point: Connect the test leads to the desired test points on the de-energized circuit board. For single-channel testing, use A and COM. For dual-channel or comparative testing, use A, B, and COM.
Detailed view of the internal circuit board of a VI Curve Tester, showing BNC connectors, power input, and various electronic components.
Figure 4: Internal view of a VI Curve Tester, illustrating BNC outputs and power input (DC 24V).

5. Operating Instructions

The operation varies slightly between models. Refer to the specific controls on your device.

5.1 NI-210G Model Controls (Refer to Figure 5)

Close-up of the NI-210G control panel with labels for voltage (0.6V, 4V, 8V, 16V), frequency (60Hz, 400Hz, 2000Hz), channel (A, A+B), scan, and pulse buttons.
Figure 5: Detailed control panel of the NI-210G model.
  • Voltage Selection: Press the buttons labeled LOW (0.6V), MED1 (4V), MED2 (8V), or HIGH (16V) to select the desired test voltage.
  • Frequency Selection: Press the buttons labeled 60Hz, 400Hz, or 2000Hz to choose the test frequency.
  • Channel Selection: Use the 'A' button for single-channel testing or 'A+B' for dual-channel testing.
  • Scan Function: Press the 'SCAN' button to activate the scanning mode, which may cycle through test parameters.
  • Pulse Function: Press the 'Pulse' button for specific pulse testing modes.

5.2 NI-210SJ / NI-210SS Model Controls (Refer to Figure 6)

Front panel of the plastic shell dual channel display model (NI-210SS) with buttons for LOW, MED1, MED2, HIGH voltage, and knobs for impedance and alternating display.
Figure 6: Control panel of the NI-210SS model (similar to NI-210SJ).
  • Voltage Selection: Press the LOW, MED1, MED2, or HIGH buttons to select the test voltage.
  • Impedance Adjustment: Rotate the impedance knob to adjust the internal resistance for different testing scenarios.
  • Alternating Switch: Use the alternating switch to toggle between different display modes (e.g., A/B channel alternation).
  • Channel Inputs: Connect test leads to A, B, and G (Ground) terminals as required for your test.

5.3 Interpreting VI Curves

The VI Curve Tester generates a voltage-current (V-I) characteristic curve on the oscilloscope. By comparing the curve of a known good component or circuit with that of a faulty one, you can identify anomalies such as opens, shorts, leakage, or changes in component values. Different components (resistors, capacitors, diodes, transistors) will produce distinct curve shapes.

An oscilloscope screen displaying various VI curve patterns, including a straight line for a resistor, an ellipse for a capacitor, and diode curves.
Figure 7: Examples of VI curves for different electronic components displayed on an oscilloscope.

6. Specifications

Feature Specification
Input Power DC 24V
Test Voltage Levels (NI-210G) 0.6V, 4V, 8V, 16V
Test Voltage Levels (NI-210SJ/SS) LOW, MED1, MED2, HIGH
Test Frequency Levels (NI-210G) 60Hz, 400Hz, 2000Hz
Channels Single (A), Dual (A+B) or A, B, G
Shell Material Plastic or Acrylic (model dependent)
Product Type Semi-finished product (may require integration)

7. Maintenance and Care

  • Cleaning: Wipe the exterior of the device with a soft, dry cloth. For stubborn stains, use a slightly damp cloth and dry immediately. Do not use alcohol, corrosive detergents, bleach, or steel wool.
  • Storage: Store the device in a cool, dry place away from direct sunlight and extreme temperatures.
  • Inspection: Periodically check test leads and connectors for any signs of wear or damage. Replace if necessary.

8. Troubleshooting

Problem Possible Cause Solution
No display on oscilloscope Incorrect oscilloscope settings (not X-Y mode), loose BNC connections, no power to tester. Ensure oscilloscope is in X-Y mode. Check all BNC cable connections. Verify power adapter is connected and functional.
Distorted or unstable curve Poor test lead connection, faulty component, interference, live circuit. Ensure test leads are firmly connected. Re-test with a known good component. Check for external interference. Ensure the circuit under test is NOT live.
Tester not powering on Power adapter issue, loose power connection. Verify the DC 24V power adapter is working and properly connected. Try a different compatible power adapter if available.

9. User Tips

  • For best results, always compare the VI curve of a suspected faulty component or circuit section with that of a known good one.
  • Experiment with different voltage and frequency settings to observe how the component's characteristics change, which can provide more diagnostic information.
  • When testing components in-circuit, remember that other parallel components can influence the observed VI curve. Desoldering components for individual testing often provides clearer results.

10. Warranty and Support

Your ASA VI Curve Tester comes with the following warranty:

  • New Products: 6 months warranty from the date of purchase.
  • Used Products: 30 days warranty from the date of purchase.

This warranty covers manufacturing defects under normal use. Damage caused by misuse, unauthorized modification, or live operation is not covered. If you encounter any issues or require technical assistance, please contact your seller for support.

11. Additional Resources

For a more detailed user manual, you may refer to the official PDF document:

View User Manual (PDF)