1. Product Overview and Package Contents
The VOTOL EM80 GTS Controller Kit is designed for electric vehicles utilizing 1000W-2000W PMSM motors, such as QS90 and QS120 mid-drive motors. This kit provides essential components for motor control and user interface.
1.1 Package Contents
- 1 pc x EM-80 GTS Controller with function harness
- 1 pc x USB Cable
- 1 pc x DKD Display with bracket
- 1 set x T08 Throttle
Image: Components included in the VOTOL EM80 GTS Controller Kit.
NOTE: The DKD display and T08 throttle are not plug-and-play with the controller; manual wiring is required.
2. Setup and Installation
2.1 Software Installation (Windows 7/10 Only)
The EM80 GTS controller requires software for parameter adjustment and updates. This software is compatible with Windows 7 and 10 operating systems. iOS and XP systems are not supported.
- USB Driver Installation:
- Download and decompress the "USB-to-serial-win 10-20150814" file.
- Choose the appropriate driver for your computer (32-bit or 64-bit).
- After installation, connect the USB cable to the controller and computer.
- If connection fails, right-click "My Computer" > "Device Manager" > "Port (COM & LPT)", select the COM port with an exclamation mark, and update the driver software by browsing your computer for the driver files. Select "Prolific USB-to-Serial Comm Port Version: 3.3.2.102 [2008/9/24]".
- Software Installation:
- For versions from 2018.7 onwards, only the USB driver installation is needed; the software can be opened directly.
- If using an older version, copy the
TeeChart5.ocxfile to the C drive root directory. - Run the setup to register the file and complete the installation. Then, run the
EM_V3program.
- Bluetooth Serial Port Connection (Optional):
- Use a Bluetooth series port connection module (e.g., by VOLT company).
- Pair with the Bluetooth series port (password: "1234").
2.2 Controller Connection
- Power on the controller and ensure the ignition is closed.
- If your controller supports CAN, click "CAN enable" in the software, then click "Open".
- Click the "researching" button, select the appropriate series port from the device COM list (usually the last one). Click "open series port"; the device status should show "connected".
- Turn on the ignition, then click "connect" to the controller. It is recommended to click "connect" more than twice for a stable connection.
2.3 Initial Parameter Adjustment
The following parameters can be adjusted via the software. Incorrect settings can damage the controller or motor.
- Battery Voltage Adjust: The voltage parameter can be freely chosen based on the controller's hardware support. Adjusting without hardware support can damage the controller.
- Controller Under-Voltage and Soft Under-Voltage Adjust:
- Under-voltage Value: Threshold for hardware under-voltage protection. Set based on battery under-voltage value.
- Soft Under-voltage: Generally, under-voltage + 3V.
- Under-voltage Variation: Range for under-voltage recovery (unadjustable). E.g., if set to 63V for over-voltage and 1V for variation, the controller will recover at 64V. Changing under-voltage is not recommended as it can damage the battery and reduce its life.
- Controller Battery Current and Phase Current Limited Adjust:
- Battery Current: Set within the specified range for your controller model (e.g., EM-80 GTS: 48-60V ≤150A, 72V ≤180A). Do not exceed the range to prevent controller damage.
- Phase Current: Limits motor torque output. Setting range is the biggest value for full power output; adjustment is not generally suggested.
- Throttle Voltage Adjust:
- Low Protection Value: Indicates throttle error.
- Start Voltage: Motor starts running when this value is reached.
- End Voltage: Controller considers full voltage reached. Recommended to set 0.2V lower than actual torque voltage.
- High Protection Value: Indicates torque fault if exceeded.
- Start Setting Adjustment (for tricycle gearbox only): Adjust starting torque, combined torque, upward slope, and downward slope of motor torque.
- Controller and Motor Temperature Protection Function Adjustment: Set start, over-temperature, recovery, and maximum temperature values to limit motor torque and protect the system.
2.4 Motor Setting
- Motor Pole Pairs: Correctly fill in the motor pole pair for accurate RPM acquisition.
- Motor Type (Middle Drive Motor): Correctly fill in the motor's magnet type for proper matching. Wheel hub motors are surface mount; QS motors can set 120 Hall shift for V3 motors.
- Hall Phase Shift Angle: Adjust within -180° to 180°. Common test values include -180, -120, -60, 0, 60, 120, 180. To change running direction, adjust by ±120° from your correct data.
Image: Dimensions of the VOTOL EM80 GTS Controller.
Image: Detailed wiring diagram and pinout for the EM80 GTS Controller.
2.5 Speedometer Output Choice
The controller supports two types of speedometer output: ONE-LIN speedometer and Hall speedometer. The choice depends on the vehicle's speedometer type. The ONE-LIN communication uses the xinsiwei agreement.
3. Operating Instructions
3.1 Sports Mode (S Gear) Settings
- Current-Limiting Value: When the controller enters S gear, battery current increases for more powerful climbing.
- Flux Weakening Value: Adjusts motor running noise and shock. If the motor experiences shock, lower this value (below 800). This value does not reduce speed. The range for flux weakening depends on the voltage mode (low vs. high voltage). For single voltage controllers, keep left/right values the same.
- Automatic Logout Enablers: Optional setting for S gear auto-exit after a specified time (e.g., 30 seconds). Recovery time defines when the S gear can be re-engaged.
3.2 Downhill Electric Brake Assist (HDC/HHC)
This function helps maintain a constant speed on steep slopes by stabilizing RPM. Enable "HDC Enable" to use. If your motor has 1000 RPM, you can set this data between 1000-1200 RPM. Do not set this value significantly higher than the motor's real RPM (suggested range: real RPM *110%~120%).
3.3 Speed Limit Setting
Enable the speed limit function to adjust the controller's speed limit from 0 to 100 percent. This can be customized via the sport wire to the speed limit function.
3.4 Flux Weakening & Three Speed Setting
- Flux Weakening Compensation: Default values are 34 for hub motors less than 40mm magnet and 64 for other motors. Can be adjusted for different motors. If flux weakening is not desired, set to 200-500.
- Three Gear Setting: The three gear ratio ranges from 0-100%. There are two modes: button-activated or switch-activated. Default gear can be changed upon power-on.
- Soft Start Enable: Allows the controller to start softly. Soft start grade ranges from 1 to 16, with lower values indicating a softer start.
3.5 Moving Assist and Cruising Function
- Moving Assist: Valid after checking. The speed of the transfer assist is a percentage of the motor base speed (default 10%).
- Cruise Function: Valid after checking. Maintain a certain throttle angle for more than 8 seconds to enter cruise control. Any operation (e.g., braking, turning the handle) will exit cruise mode.
3.6 Reversing, EBS Setting, Low Brake Selection, Starting Safety Switch Function
- Reversing Speed Limit: Adjustable from 0-100%. Do not exceed 30% to avoid accidents.
- EBS Ratio: Adjustable from 0-100% for electronic brake force.
- Low Brake Enable: When enabled, the original single-branch power-down function becomes a low-level brake.
- Safety Switch Function: If enabled, the safety switch must be pressed before starting the vehicle.
3.7 Three Speed Setting
For EM30S/50S/100S/150S models, three speeds are achieved by switch (PD0-low, PD1-high, PB3-middle). For EM200S, three speeds are achieved by switch (PA0-low, PB2-high). For button-activated three speeds, PD1 is e-gear button and PB3 is sport mode.
Image: T08 Throttle (left and right grips).
Image: Wiring diagram for the T08 Throttle, showing connections for steering switch, flash, P gear, horn, three speed, light, repair, reverse, and throttle signal.
4. Maintenance
4.1 Software Update and Debugging
Software updates, current calibration, and remote operation should be performed under the guidance of a company engineer. To update, click "opening file", choose the ".bin" file, and click "download". The file import is successful when it shows 100%.
4.2 Brushing the Bottom Program
If the controller cannot communicate with the software, you may need to brush the bottom program:
- Close the ignition.
- Open the debugging software, open the serial port (no need to click "connect").
- Open the ignition, then open the "CAN.Bin" file.
- The controller should then connect normally.
5. Troubleshooting
5.1 Software Installation and COM Port Issues
- Software Cannot Be Installed: Try changing your computer system language to English or Chinese, as C++ runtime libraries can differ across systems.
- Software COM Port Cannot Be Found: If your computer has COM information but the software doesn't show it, there might be a driver problem. Re-research or install the "FT232 Driver" file.
5.2 Controller Fault or Hall Error
If the controller runs fine on the road but the software shows a controller fault when connected to a PC, it's usually not a problem with the controller itself. If the controller cannot run on the road and the software shows a Hall error (with Hall connected), check the plug connection first. If the connection is good, test the Hall voltage from the motor. Hall positive and negative should be 5V, and the voltage of the three Hall signal wires should be the same. If not, the motor Hall might be faulty or damaged.
5.3 Testing Controller Hall Error
If you suspect a Hall fault, you can test the controller Hall voltage:
- Connect the positive and negative terminals of the battery to the controller.
- Connect the ignition and power on.
- Measure the positive and negative poles of the controller Hall. It should be around 5V. If the reading is significantly different (e.g., 0.9V), the Hall port is damaged.
All controllers are tested before shipping. Damage to the Hall port is typically caused by incorrect wiring (e.g., wrong wire connection of the Hall plug, different color sequence, or incorrect positive/negative connection).
Image: Example of using a multimeter to test Hall voltage.
5.4 Reverse Function Not Working
If the reverse function wire is connected correctly and the display shows 'R' gear, but the motor doesn't reverse, check your software parameters. Sometimes there might be two ports configured for reverse; remove one to empty to resolve the issue.
5.5 Motor Still Running After Stopping Throttle
If the motor continues to run after you stop twisting the throttle, you may need to adjust the Hall shift data. Try changing values like -60 to 120 and test different settings. Refer to the 4.1 setting guide for more details.
5.6 Matching a New Brand Controller
For initial testing, ensure the phase wire and Hall wire connections are correct. Set the motor poles and Hall shift data accurately. Hall shift is crucial and can be tested from -180 to 180. Refer to the 4.1 setting guide.
6. Specifications
6.1 EM-80 GTS Controller Specification
- Model: EM-80 GTS sine wave controller
- Available Battery Voltage: 48V-72V
- Rated DC current: 60A
- Boost DC current: 100A
- Peak Phase current: 230A
- Max. Power: 7200W
- Mosfets Detail: 18 FET
- Matched Motor Rated Power: 1.5KW-2KW
- Max. Efficiency: 93%
- Degree of Waterproof: IP65
- Flux Weakening Ratio: 150%
- Certification: CE, CCC
- Working Communication: Hall Sensor
- Net weight: 0.9kg
- Size: 180mm * 96mm * 56mm
- Support Programmable by PC
Image: Top view of the VOTOL EM80 GTS Controller with the cover removed, showing terminals and connectors.
Image: Bottom view of the VOTOL EM80 GTS Controller with the cover on, showing terminals.
6.2 DKD Display Specification
- Displays data: Speed (KMH/MPH), DC current, Battery Level, Trip Distance, Fault Display, Head Light, Turning Light, Gear Display.
Image: Front view of the DKD Display showing various indicators.
Image: Dimensions and wiring definition for the DKD Speedometer Display (5557-2*10 connector).
Image: DKD Display with its customized mounting bracket.
6.3 T08 Throttle Specification
- Functions: Three Speed, P Gear, Reverse, One Click Repair, Left Turn Signal, Right Turn Signal, Headlight, Horn, High Beam, Low Beam.
7. User Tips
- VOTOL controllers generally match well with QS motors. For other motor brands, be prepared to adjust parameters yourself.
- The DKD display and T08 throttle require manual wiring; they are not plug-and-play.
- Most functional interfaces on the controller require modification and are not plug-and-play. Always check the function line on your original vehicle and the speedometer's communication signal before making modifications.
- If you lack experience in assembling electric kits, consider seeking professional assistance or making a prudent choice before purchasing, as man-made damage is not covered by warranty.
- For optimal performance and safety, ensure all wiring connections are secure and correct. Incorrect wiring can lead to component damage.
8. Warranty and Support
8.1 Warranty Information
We offer a 1-year warranty for motors and controllers. However, the buyer is responsible for return shipping costs for repairs or replacements. The warranty does not cover man-made damage.
8.2 Further Assistance
If you encounter any problems or require further assistance, please contact the seller or manufacturer's support channels. For detailed programming instructions, you may refer to the official user manual PDF: VOTOL EM Controller Program Manual (PDF).