1. Introduction

This POWLAND Hybrid Solar Inverter is a multi-function inverter/charger, combining the functions of an inverter, MPPT solar charger, and battery charger. It is designed to offer uninterruptible power support in a portable size. Its comprehensive LCD display provides user-configurable and easy-to-access button operations for settings such as battery charging current, AC/Solar charger priority, battery charging/cut-off voltage, and acceptable input voltage based on different applications.

Key Features:

  • Rated power 5kW/5kVA, power factor 1
  • CAN/RS485 for BMS communication
  • MPPT range 60V~450V, 500Voc
  • Ability to work without battery
  • High frequency design for small size and light weight
  • WIFI remote monitoring (optional)
  • Pure sine wave AC output
  • Dual AC output (optional)
  • Supports solar and grid power loads simultaneously
  • Feed-in to grid capability
POWLAND Hybrid Solar Inverter with key specifications
Figure 1: POWLAND Hybrid Solar Inverter highlighting 5KW 24V, 9000W Max PV Array Power, 160A Max Solar Charging Current, 93% Max Efficiency, and 60-450VDC PV Array MPPT Voltage.

2. Safety Information

Please read and understand all instructions before installing and operating the inverter. This device operates with high voltage (above 50Vac or 75Vdc) and requires careful handling to prevent electric shock or injury. Ensure all connections are secure and follow local electrical codes.

Protection Features:

  • Overload Protection
  • Overheating Protection
  • Battery Protection
  • High/Low Voltage Protection
  • Short Circuit Protection
  • Overcurrent Protection
  • Anti-Reverse Protection
  • Power Failure Protection
Icons representing various protection features of the inverter
Figure 2: Visual representation of the inverter's comprehensive protection features.

3. Product Overview

3.1. Physical Components

Front and rear panel layout of the POWLAND Hybrid Solar Inverter with numbered components
Figure 3: Front and rear panel view with labeled components.
  1. AC Indicator
  2. Invert Indicator
  3. Charging Indicator
  4. Fault Indicator
  5. LCD Display
  6. ESC Button
  7. Up Button
  8. Down Button
  9. Enter Button
  10. AC Input
  11. AC Output 1
  12. AC Output 2
  13. PV Input 1
  14. Power On/Off
  15. COM Port
  16. BMS Port
  17. Battery Input

3.2. LCD Display and Function Keys

Detailed view of the LCD display and function keys
Figure 4: Detailed LCD display showing various information and function keys.
Tables detailing LED indicators and function key descriptions
Figure 5: Tables explaining LED indicator states and function key operations.

LED Indicator Messages:

LED IndicatorColorStateMessages
AC / INVGreenSolid OnOutput is powered by utility in Line mode.
FlashingOutput is powered by battery or PV in battery mode.
CHGGreenSolid OnBattery is fully charged.
FlashingBattery is charging.
FAULTRedSolid OnFault occurs in the inverter.
FlashingWarning condition occurs in the inverter.

Function Key Descriptions:

Function KeyDescription
ESCTo exit setting mode
UPTo go to previous selection
DOWNTo go to next selection
ENTERTo confirm the selection in setting mode or enter setting mode

4. Setup and Installation

4.1. Mounting the Unit

Consider the following points before selecting where to install the inverter:

  1. Do not mount the inverter on flammable construction materials.
  2. Mount on a solid surface.
  3. Install this inverter at eye level in order to allow the LCD display to be read at all times.
  4. The ambient temperature should be between 0°C and 55°C to ensure optimal operation.
  5. The recommended installation position is to be adhered to the wall vertically.
  6. Be sure to keep other objects and surfaces as shown in the right diagram to guarantee sufficient heat dissipation and to have enough space for removing wires.

WARNING: SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.

Diagram showing mounting dimensions and system diagram with battery connected
Figure 6: Mounting dimensions and system diagram for battery-connected operation.

4.2. Battery Connection

The 5KW model supports a 24VDC system. Connect all battery packs as shown in the diagram below.

Battery connection diagram for a 24V system using two 12V batteries
Figure 7: Battery connection for a 24V system (e.g., two 12V batteries in series).

4.3. Solar System Connection

Follow the diagram below for connecting your solar panels, generator/mains power, and AC output loads. Ensure all cable gauges and breaker ratings are as recommended.

Comprehensive solar system connection diagram including PV, battery, AC input, and AC output
Figure 8: Solar System Connection Diagram.
  • Max AC Input Voltage: 240Vac
  • Charging Current: 160A
  • Suggested AC Input Cable: 10AWG
  • Recommended AC Input Breaker: 20A
  • AC Output Power: 5000VA/5000W
  • AC Output Voltage: 230Vac
  • Suggested AC Output Cable: 12AWG
  • Recommended AC Output Breaker: 20A
  • PV Power: 5000W
  • Max PV Open Circuit Voltage: 450V
  • PV MPPT Voltage Range: 60-450VDC
  • Start-up Voltage (initial charging): >80V
  • Suggested PV Cable: 10AWG
  • Battery Type: Lead-Acid (Seal, AGM, Gel, Flooded) and Lithium battery
  • Battery Voltage: 24V
  • Battery Wire Size: 1AWG
  • Battery Cable: 42mm²

NOTE: The output of the inverter is 230V.

4.4. Solar Photovoltaic Panel Wiring Method

Proper wiring of solar panels is crucial for optimal performance and safety. Panels can be wired in series or parallel depending on the desired voltage and current.

Diagram illustrating series and parallel wiring methods for solar panels
Figure 9: Solar Photovoltaic Panel Wiring Methods.

In Series:

Increase the voltage of the system. This voltage needs to be less than the hybrid inverter PV maximum input voltage Voc/inverter. For example, with 10.35A and 41.92V panels, 6 panels in series result in 41.92V * 6 = 251.52V.

In Parallel:

Parallel increases the current of the system. This current should not exceed the maximum PV input current of the hybrid inverter. For example, with 10.35A and 41.92V panels, 2 strings of 3 panels in parallel result in 10.35A * 2 = 20.7A and 41.92V * 3 = 125.76V.

Important: The entire photovoltaic system should use the same type of photovoltaic panel.

PV Cable Dimensions: 6-8A/mm²

5. Operating Instructions

5.1. Basic Operation

Once the inverter is installed and connected, turn on the Power On/Off switch (14 in Figure 3). The LCD display (5 in Figure 3) will light up, showing system status and parameters. Use the Up (7), Down (8), and Enter (9) buttons to navigate through the menus and configure settings as described in the 'Function Key Descriptions' table (Figure 5).

5.2. Wi-Fi Monitoring

The inverter supports optional Wi-Fi remote monitoring via the Wattseek APP, available for iOS and Android devices. Connect the provided Wi-Fi module to the COM port (15 in Figure 3) and follow the app instructions for setup.

Diagram showing Wi-Fi monitoring setup with the inverter and Wattseek APP QR code
Figure 10: Wi-Fi Monitoring setup and Wattseek APP QR code.

6. Maintenance

To ensure the longevity and optimal performance of your POWLAND Hybrid Solar Inverter, regular maintenance is recommended:

  • Cleaning: Periodically clean the exterior of the inverter with a dry, soft cloth. Ensure ventilation openings are free from dust and debris to prevent overheating.
  • Connections: Annually check all electrical connections (PV, battery, AC input/output) for tightness and signs of corrosion. Loose connections can lead to poor performance or safety hazards.
  • Battery Health: If using lead-acid batteries, regularly check their water levels (for flooded types) and ensure terminals are clean. Monitor battery voltage and charging cycles via the LCD display or monitoring app.
  • Environment: Ensure the installation environment remains within the recommended temperature and humidity ranges.

7. Troubleshooting

If the inverter is not functioning as expected, refer to the LED Indicator Messages table (Figure 5) for initial diagnosis. A red FAULT LED indicates a serious issue, while a flashing red LED indicates a warning condition.

  • No Power: Check all input power sources (AC grid, solar panels, batteries) and ensure the Power On/Off switch is in the 'On' position. Verify circuit breakers are not tripped.
  • No AC Output: Check for overload conditions. Reduce the load if necessary. Ensure the inverter is receiving sufficient input power from solar or battery.
  • Battery Not Charging: Verify solar panel connections and output. Check battery health and connections. Ensure charging settings are correctly configured via the LCD display.
  • Fault Indicator On: Note the specific fault code or pattern on the LCD display (if available) and consult the full manual (if provided separately) or contact technical support.

8. Specifications

Detailed technical specifications table for the POWLAND Hybrid Solar Inverter
Figure 11: Comprehensive technical specifications.
CategoryParameterValue
ModelModel NumberISolar-SMS-5KW-24V WiFi (ISolar-SMS-5KW-P)
Rated Power5000VA/5000W
AC InputAC Voltage208/220/230/240; L+N+PE
Voltage Range (VAC)90~280 (APP/GEN mode); 170~264 (UPS mode)
Frequency Range50/60Hz (Autosensing)
AC OutputSurge Power (KVA)10
Voltage (VAC)208/220/230/240
Rated Frequency50/60Hz ±0.1%
Max. Efficiency (Battery Mode)93.5%@24V
BatteryBattery Voltage24VDC
Floating Charge Voltage27VDC
Over Charge Protection33VDC
Battery TypeLithium/Lead-acid (Seal, AGM, Gel, Flooded)
Solar Charger & AC ChargerMaximum PV Array Open Voltage (V)500VDC
Maximum PV Array Power9000W
MPPT Voltage Range (V)60~450VDC
Maximum Input Current160A
Maximum Solar Charge Current160A
Maximum AC Charge Current160A
General ParametersOperation Temperature-10°C~60°C
Relative Humidity5%~95% (Non-condensing)
Max. Operating Altitude4000m (Derating above 2000m)
Dimensions DxWxH (CM)44.5*38.5*16.5CM
WeightNet Weight (KG)8KGS
CommunicationInterfaceStandard: RS232; CAN & RS485; WiFi
Safety StandardEN/IEC62109-1, EN/IEC62109-2

9. Warranty and Support

The POWLAND Hybrid Solar Inverter comes with a 1-year warranty from the date of purchase. For any issues or technical support, please contact POWLAND Store. All inquiries will be answered within 24 hours.

Warranty and service information, including 1-year warranty and 24-hour email response
Figure 12: Warranty and Service details.
Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.