ANENG GN703

ANENG GN703 LCR Bridge Tweezers Tester User Manual

Model: GN703 | Brand: ANENG

1. Introduction

The ANENG GN703 is a professional-grade digital LCR (Inductance, Capacitance, Resistance) meter designed for high-precision electronic component testing. It supports multiple test frequencies (100Hz/1kHz/10kHz) and provides accurate measurements for resistors, capacitors, and inductors across wide ranges. With features like data hold, calibration, USB direct charging, and a user-friendly bilingual interface, it is an essential tool for electricians, technicians, and DIY enthusiasts.

This product is our latest research and development of a handheld tweezer shaped LCR bridge, equipped with a built-in 250mAh rechargeable lithium polymer battery, long standby time, fast measurement speed, and a TFT color display screen. The unique tweezer shaped design makes it particularly suitable for fine operations and rapid testing of electronic components in small spaces. The lightweight and portable characteristics make it an indispensable and efficient tool for on-site engineers and laboratories.

ANENG LCR Smart Digital Bridge Tester with key features highlighted
Figure 1: ANENG GN703 LCR Smart Digital Bridge Tester overview.
Video 1: Demonstration of the ANENG GN703 LCR Tester's features and usage.

2. Safety Information

To avoid possible electric shock, fire, and personal injury, please read the safety precautions before use:

  1. Do not measure voltage to avoid damaging instruments and personal injury.
  2. Do not use the instrument in flammable, explosive, or high-temperature environments, and do not input voltage.
  3. Do not use this product around explosive gases and vapors or in humid environments.
  4. Waste batteries and scrapped instruments used for instrument replacement cannot be disposed of together with household waste. Please handle them in accordance with relevant national or local laws and regulations.

3. Product Overview

The ANENG GN703 is a compact and intelligent LCR tester designed for precision. It features a clear HD color screen display and intuitive controls.

3.1. Components and Display

Screen panel introduction showing measurement range, frequency, battery level, and other display elements
Figure 2: Screen Panel Introduction. Displays measurement range, frequency, battery level, measurement level, Rs measurement, unit symbol, D loss value, Q factor, Z impedance, X reactance. Long press 'S' to switch secondary display parameters.
Product panel with labeled buttons and ports
Figure 3: Product Panel. Includes Test clip, Measuring arm, HD color screen display, Hold/Set button, Power on key, Charging port, Right click settings, Interface settings, Left click settings, Charging indicator light.

3.2. Accessories List

The package includes:

  • 1 x Packaging box
  • 1 x LCR bridge tester (ANENG GN703)
  • 1 x User Manual
  • 1 x Charging cable (USB Type-C)
Accessories list showing the LCR bridge tester, manual, charging cable, and packaging box
Figure 4: Included Accessories.

4. Setup

4.1. Charging the Device

The ANENG GN703 is equipped with a 250mAh rechargeable lithium battery. Before first use, or when the battery indicator is low, charge the device using the provided USB Type-C cable.

  • Connect the USB Type-C cable to the charging port on the device.
  • Connect the other end of the USB cable to a 5V/1A USB power source (e.g., computer USB port, wall adapter).
  • The charging indicator light will be red during charging and turn green when fully charged.
USB charging illustration with red light for charging and green for full
Figure 5: USB Charging Process.

4.2. Power On/Off

  • Power On: Short press the power button (usually marked with a power symbol) to turn on the device.
  • Power Off: Long press the power button to turn off the device.

5. Operating Instructions

5.1. Automatic Recognition (AUTO Mode)

The GN703 features intelligent automatic recognition, allowing it to identify the component type (resistance, capacitance, inductance, diode, continuity) and select the appropriate measurement range automatically. Simply make reliable contact with the component using the tweezers.

ANENG Precise/Efficient Auto-ID measuring an SMD component
Figure 6: Auto-ID feature in action.
Automatic recognition of components on a circuit board
Figure 7: AUTO automatic recognition for various components.

5.2. Manual Mode and Measurement Functions

You can manually switch between different measurement modes and adjust settings using the 'M' and arrow keys.

Multifunctional measurement modes including Resistance, Diode, Capacitor, Inductance, On-off beeping
Figure 8: Multifunctional Measurement Modes.
  • Resistance: Use the AUTO range or manually switch to the resistance range, and ensure the tweezers make reliable contact with the resistor being tested.
  • Diode: Switch to the diode range, and ensure the tweezers make reliable contact with the diode. Conduction voltage < 0.7V.
  • Capacitance: Use the AUTO range or manually switch to the capacitance range, and ensure the tweezers make reliable contact with the capacitor. Note: Discharge the capacitor before measurement to avoid damaging the instrument.
    Capacitance detection showing the device measuring a capacitor
    Figure 9: Capacitance Detection.
  • Inductance: Use the AUTO range or manually switch to the inductance range, and ensure the tweezers make reliable contact with the inductor being tested.
    Inductance test showing the device measuring an inductor
    Figure 10: Inductance Test.
  • On-off beeping (Continuity): When testing for continuity, a continuous beeping sound will be emitted when the measured value is within the continuity threshold.

5.3. Settings Interface

Long press the 'M' key to enter the settings interface. Here you can adjust system language, volume settings, screen brightness, auto-shutdown, factory reset, and view information about the device.

Settings interface showing options for language, volume, backlight, auto-off, restore, and about
Figure 11: Settings Interface.
  • Language: Switch between Chinese and English.
  • Volume: Adjust the buzzer volume (0-5 gear).
  • Backlight (Brightness): Adjust screen brightness (0-100 stepless dimming).
  • Auto-Off: Set the automatic shutdown time (Off/5/15/30 minutes).
  • Factory Reset: Restore to factory system settings, clearing all parameters.
Tweezer head for accurate measurement and language switch option
Figure 12: Tweezer Head and Language Switch.

5.4. Data Hold and Calibration

  • Data Hold: Short press the 'HD/Set' button to hold the current data on the screen. Press again to release.
  • Calibration: The device supports calibration for accurate measurements. Refer to the on-screen prompts or the full PDF manual for detailed calibration procedures.

5.5. Test Frequencies and Levels

The GN703 supports three test frequencies: 100Hz, 1KHz, and 10KHz, and offers 0.3V/0.6V test levels for comprehensive and accurate measurements.

3-Band Test Effective Level diagram showing 100Hz, 1KHz, 10KHz frequencies and 0.3V/0.6V test levels
Figure 13: 3-Band Test Effective Level.

6. Maintenance

  • Cleaning: Use a soft, dry cloth to clean the device. Do not use abrasive cleaners or solvents.
  • Storage: Store the device in a cool, dry place away from direct sunlight and extreme temperatures.
  • Battery Care: To prolong battery life, avoid fully discharging the battery frequently. Charge the device regularly, even if not in use for extended periods.
  • Tweezer Tips: Ensure the tweezer tips are clean and free from debris for accurate contact and measurement.

7. Troubleshooting

  • Device not turning on: Ensure the battery is charged. Connect the device to a USB power source and try again.
  • Inaccurate readings: Ensure the tweezer tips are making firm and clean contact with the component. Try calibrating the device if available. Check for any visible damage to the tips.
  • Screen not responding: Try restarting the device by long-pressing the power button. If the issue persists, ensure the battery is charged.
  • No continuity beep: Verify the device is in continuity mode and that the component is indeed continuous within the threshold.

8. Specifications

FunctionRange100Hz1KHz10KHz
Resistance10mΩ~1Ω3%±5dig3%±5dig2%±5dig
1Ω~1KΩ1%+3dig0.5%±5dig0.5%±5dig
1KΩ~1MΩ1%±5dig0.5%±5dig1%±5dig
1MΩ~10MΩ5%±3dig5%±3dig
Capacitance1pF~1nF5%±5dig5%±5dig
1nF~1uF2%±5dig0.5%±5dig0.5%±5dig
1uF~1mF2%±5dig2%±5dig2%±5dig
1mF~22mF5%±5dig5%±5dig
Inductance1uH~10uH2%±3dig
10uH~1mH2%±3dig0.5%±3dig0.5%±3dig
1mH~100mH2%±3dig2%±3dig2%±3dig
100mH~10H5%±3dig
DiodeOn Voltage < 0.7V
Continuity
Brightness0~100 Stepless Dimming
ResetFactory Reset, Clear All Params
Volume0~5 Gear Adjust
Auto offOff/5/15/30min
Li-ion chg250mAh Li-ion Rechg
Charge specUSB 5V/1AData Hold
LanguageChinese/EnglishCalibration
MaterialABSTest level0.3V/0.6V
Test freq100Hz/1K/10K

Note: The above parameters are for reference only; the actual measurements of the equipment shall prevail.

9. User Tips

  • For best accuracy, ensure the component is isolated from the circuit when measuring, especially for capacitance and inductance.
  • Always discharge capacitors before testing to prevent damage to the device or the component.
  • Utilize the 'Data Hold' function when taking measurements in hard-to-reach areas to easily record the reading.
  • Adjust the screen brightness and auto-off settings to conserve battery life according to your usage.

10. Warranty and Support

For detailed warranty information and technical support, please refer to the official ANENG documentation or contact your retailer.

A comprehensive user manual in PDF format is available for download. This manual provides more in-depth information on advanced features, calibration procedures, and detailed specifications.

Download User Manual (PDF): Click here to view the PDF manual

Related Documents - GN703

Preview ANENG GN703 LCR Bridge Tweezers Tester User Manual
Comprehensive user manual for the ANENG GN703 LCR Bridge Tweezers Tester, detailing its features, specifications, operation, and troubleshooting for accurate resistance, capacitance, inductance, continuity, diode, and frequency measurements.
Preview ANENG GN702 LCR Tweezers Bridge Tester User Manual and Specifications
Comprehensive user manual for the ANENG GN702 LCR Tweezers Bridge Tester, detailing specifications, safety precautions, usage instructions, calibration, and maintenance.
Preview ANENG 683 Digital Multimeter User Manual and Specifications
Comprehensive user manual for the ANENG 683 digital multimeter, covering safety instructions, technical specifications, operating procedures, maintenance, and package contents. Learn how to accurately measure voltage, current, resistance, capacitance, and temperature.
Preview ANENG GN702 Smart Bridge Tweezer User Manual
User manual for the ANENG GN702 Smart Bridge Tweezer, covering specifications, operation, calibration, and maintenance for this high-precision LCR meter.
Preview ANENG ST181 Mini Digital Clamp-On Multimeter Operation Manual
Operation manual for the ANENG ST181 Mini Digital Clamp-On Multimeter, covering safety, panel description, specifications, and detailed instructions for various electrical measurements including voltage, current, resistance, capacitance, frequency, and temperature.
Preview ANENG SZ305 Digital Multimeter Operator's Instruction Manual
This manual provides comprehensive safety information, operation instructions, specifications, and maintenance details for the ANENG SZ305 Digital Multimeter, a compact, hand-held, and battery-operated electronic measuring instrument.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.