1. Introduction
The ANENG GN703 is a professional-grade digital LCR (Inductance, Capacitance, Resistance) meter designed for high-precision electronic component testing. It supports multiple test frequencies (100Hz/1kHz/10kHz) and provides accurate measurements for resistors, capacitors, and inductors across wide ranges. With features like data hold, calibration, USB direct charging, and a user-friendly bilingual interface, it is an essential tool for electricians, technicians, and DIY enthusiasts.
This product is our latest research and development of a handheld tweezer shaped LCR bridge, equipped with a built-in 250mAh rechargeable lithium polymer battery, long standby time, fast measurement speed, and a TFT color display screen. The unique tweezer shaped design makes it particularly suitable for fine operations and rapid testing of electronic components in small spaces. The lightweight and portable characteristics make it an indispensable and efficient tool for on-site engineers and laboratories.

2. Safety Information
To avoid possible electric shock, fire, and personal injury, please read the safety precautions before use:
- Do not measure voltage to avoid damaging instruments and personal injury.
- Do not use the instrument in flammable, explosive, or high-temperature environments, and do not input voltage.
- Do not use this product around explosive gases and vapors or in humid environments.
- Waste batteries and scrapped instruments used for instrument replacement cannot be disposed of together with household waste. Please handle them in accordance with relevant national or local laws and regulations.
3. Product Overview
The ANENG GN703 is a compact and intelligent LCR tester designed for precision. It features a clear HD color screen display and intuitive controls.
3.1. Components and Display


3.2. Accessories List
The package includes:
- 1 x Packaging box
- 1 x LCR bridge tester (ANENG GN703)
- 1 x User Manual
- 1 x Charging cable (USB Type-C)

4. Setup
4.1. Charging the Device
The ANENG GN703 is equipped with a 250mAh rechargeable lithium battery. Before first use, or when the battery indicator is low, charge the device using the provided USB Type-C cable.
- Connect the USB Type-C cable to the charging port on the device.
- Connect the other end of the USB cable to a 5V/1A USB power source (e.g., computer USB port, wall adapter).
- The charging indicator light will be red during charging and turn green when fully charged.

4.2. Power On/Off
- Power On: Short press the power button (usually marked with a power symbol) to turn on the device.
- Power Off: Long press the power button to turn off the device.
5. Operating Instructions
5.1. Automatic Recognition (AUTO Mode)
The GN703 features intelligent automatic recognition, allowing it to identify the component type (resistance, capacitance, inductance, diode, continuity) and select the appropriate measurement range automatically. Simply make reliable contact with the component using the tweezers.


5.2. Manual Mode and Measurement Functions
You can manually switch between different measurement modes and adjust settings using the 'M' and arrow keys.

- Resistance: Use the AUTO range or manually switch to the resistance range, and ensure the tweezers make reliable contact with the resistor being tested.
- Diode: Switch to the diode range, and ensure the tweezers make reliable contact with the diode. Conduction voltage < 0.7V.
- Capacitance: Use the AUTO range or manually switch to the capacitance range, and ensure the tweezers make reliable contact with the capacitor. Note: Discharge the capacitor before measurement to avoid damaging the instrument.

Figure 9: Capacitance Detection. - Inductance: Use the AUTO range or manually switch to the inductance range, and ensure the tweezers make reliable contact with the inductor being tested.

Figure 10: Inductance Test. - On-off beeping (Continuity): When testing for continuity, a continuous beeping sound will be emitted when the measured value is within the continuity threshold.
5.3. Settings Interface
Long press the 'M' key to enter the settings interface. Here you can adjust system language, volume settings, screen brightness, auto-shutdown, factory reset, and view information about the device.

- Language: Switch between Chinese and English.
- Volume: Adjust the buzzer volume (0-5 gear).
- Backlight (Brightness): Adjust screen brightness (0-100 stepless dimming).
- Auto-Off: Set the automatic shutdown time (Off/5/15/30 minutes).
- Factory Reset: Restore to factory system settings, clearing all parameters.

5.4. Data Hold and Calibration
- Data Hold: Short press the 'HD/Set' button to hold the current data on the screen. Press again to release.
- Calibration: The device supports calibration for accurate measurements. Refer to the on-screen prompts or the full PDF manual for detailed calibration procedures.
5.5. Test Frequencies and Levels
The GN703 supports three test frequencies: 100Hz, 1KHz, and 10KHz, and offers 0.3V/0.6V test levels for comprehensive and accurate measurements.

6. Maintenance
- Cleaning: Use a soft, dry cloth to clean the device. Do not use abrasive cleaners or solvents.
- Storage: Store the device in a cool, dry place away from direct sunlight and extreme temperatures.
- Battery Care: To prolong battery life, avoid fully discharging the battery frequently. Charge the device regularly, even if not in use for extended periods.
- Tweezer Tips: Ensure the tweezer tips are clean and free from debris for accurate contact and measurement.
7. Troubleshooting
- Device not turning on: Ensure the battery is charged. Connect the device to a USB power source and try again.
- Inaccurate readings: Ensure the tweezer tips are making firm and clean contact with the component. Try calibrating the device if available. Check for any visible damage to the tips.
- Screen not responding: Try restarting the device by long-pressing the power button. If the issue persists, ensure the battery is charged.
- No continuity beep: Verify the device is in continuity mode and that the component is indeed continuous within the threshold.
8. Specifications
| Function | Range | 100Hz | 1KHz | 10KHz |
|---|---|---|---|---|
| Resistance | 10mΩ~1Ω | 3%±5dig | 3%±5dig | 2%±5dig |
| 1Ω~1KΩ | 1%+3dig | 0.5%±5dig | 0.5%±5dig | |
| 1KΩ~1MΩ | 1%±5dig | 0.5%±5dig | 1%±5dig | |
| 1MΩ~10MΩ | 5%±3dig | 5%±3dig | ||
| Capacitance | 1pF~1nF | 5%±5dig | 5%±5dig | |
| 1nF~1uF | 2%±5dig | 0.5%±5dig | 0.5%±5dig | |
| 1uF~1mF | 2%±5dig | 2%±5dig | 2%±5dig | |
| 1mF~22mF | 5%±5dig | 5%±5dig | ||
| Inductance | 1uH~10uH | 2%±3dig | ||
| 10uH~1mH | 2%±3dig | 0.5%±3dig | 0.5%±3dig | |
| 1mH~100mH | 2%±3dig | 2%±3dig | 2%±3dig | |
| 100mH~10H | 5%±3dig | |||
| Diode | On Voltage < 0.7V | |||
| Continuity | √ | |||
| Brightness | 0~100 Stepless Dimming | |||
| Reset | Factory Reset, Clear All Params | |||
| Volume | 0~5 Gear Adjust | |||
| Auto off | Off/5/15/30min | |||
| Li-ion chg | 250mAh Li-ion Rechg | |||
| Charge spec | USB 5V/1A | Data Hold | √ | |
| Language | Chinese/English | Calibration | √ | |
| Material | ABS | Test level | 0.3V/0.6V | |
| Test freq | 100Hz/1K/10K | |||
Note: The above parameters are for reference only; the actual measurements of the equipment shall prevail.
9. User Tips
- For best accuracy, ensure the component is isolated from the circuit when measuring, especially for capacitance and inductance.
- Always discharge capacitors before testing to prevent damage to the device or the component.
- Utilize the 'Data Hold' function when taking measurements in hard-to-reach areas to easily record the reading.
- Adjust the screen brightness and auto-off settings to conserve battery life according to your usage.
10. Warranty and Support
For detailed warranty information and technical support, please refer to the official ANENG documentation or contact your retailer.
A comprehensive user manual in PDF format is available for download. This manual provides more in-depth information on advanced features, calibration procedures, and detailed specifications.
Download User Manual (PDF): Click here to view the PDF manual