1. Introduction
This manual provides comprehensive instructions for the assembly, installation, operation, and troubleshooting of your PowMr 3.5KW DC 24V Hybrid Inverter. Please read this manual carefully before installation and operation to ensure safe and efficient use.
1.1. Purpose
This inverter integrates an MPPT solar charging controller, a high-frequency pure sine wave inverter, and a UPS function module. It is designed for off-grid backup power supply and self-consumption systems, providing reliable power conversion in a compact size.
1.2. Target Group
This manual is intended for both professionals and end-users. While basic operations can be performed by end-users, professionals should have a deeper understanding of electrical systems and safety protocols.
1.3. Features
- Pure sine wave output.
- Selectable input voltage range for utility grid.
- Adjustable charging current via LCD.
- Simultaneous solar and utility grid power to loads.
- AC input compatible with mains and generator.
- Automatic restart when mains power is restored.
- Overload, over temperature, and short circuit protection.
- Intelligent battery charging design.
- RS485 port for BMS communication.
- Cold start function.
- Intelligent fan speed adjustment.
- Built-in MPPT: operating voltage range 55V~430V, open circuit voltage 450Voc.
- WIFI remote monitoring (optional).
1.4. Basic System Architecture
The inverter/charger can be integrated into a system with solar modules, a generator or utility grid, and external battery packs to power home appliances.

2. Safety Instructions
⚠ Warning: This article contains important safety and operation instructions. Please read and save this manual for future reference.
- Choose the correct battery setting (lead-acid or lithium) to ensure normal system operation.
- Read all instructions and cautions before using the unit.
- Never short-circuit AC output and DC input. Do not connect mains when DC input is short-circuited.
- Never charge non-rechargeable batteries.
- Do not disassemble the unit. Refer to professional service for maintenance.
- Disconnect all wiring before maintenance to reduce electric shock risk.
- Exercise caution with metal tools around batteries to prevent short circuits and explosions.
- Select appropriate cable sizes for optimal operation.
- Follow installation procedures strictly when disconnecting AC or DC terminals.
- Ensure proper grounding according to local regulations.
- Provide appropriate fuse for battery power supply.
- Only professional service personnel should repair this equipment.
3. Setup (Installation)
3.1. Unpacking and Inspection
Upon unpacking, ensure no damage occurred during transit. The package should contain:
- Inverter Machine x 1
- User Manual x 1
3.2. Preparation Before Installation
Before connecting any wiring, remove the bottom cover by unscrewing the two retaining screws.
3.3. Installation Location
Consider the following points for selecting an installation location:
- Do not mount on flammable construction materials.
- Mount on a solid surface.
- Install at eye level for LCD display readability.
- Allow approximately 20 cm clearance on sides and above, and 50 cm below for proper air circulation.
- Ambient temperature should be between 0°C and 55°C.
- Adhere vertically to the wall.
- Ensure enough space for heat dissipation and wire removal.
⚠ Suitable for installation on concrete or other non-combustible surface only.
Tighten the screws to fix the inverter. M4 or M5 screws are recommended.
3.4. Product Overview (Physical Layout)
Familiarize yourself with the inverter's components and connection points.


3.5. Battery Connection
⚠ Warning: Install an independent DC overcurrent protector or disconnect device between the battery and inverter. All wiring must be performed by qualified personnel.
3.5.1. Lead-Acid Battery Connection
Recommended battery cable specifications:
| Model | Wire Specification | Torque Value |
|---|---|---|
| 2.5KVA-12V | 1 * 4 AWG (22mm2) | 2-3 Nm |
| 3.5KVA-24V | 1 * 6 AWG (13mm2) | 2-3 Nm |
Steps:
- Connect battery according to specifications.
- Connect all battery packs as needed.
- Insert ring terminal into inverter battery connector, tighten bolts to 2-3 Nm. Ensure correct polarity.

3.5.2. Lithium Battery Connection
For lithium batteries, only those matched with BMS communication protocol are allowed.
- Connect battery according to recommended cable specifications.
- Insert ring terminal into inverter battery connector, tighten bolts to 2-3 Nm. Ensure correct polarity.
- Connect one side of RJ45 cable to the BMS communication port of inverter.
- Insert the other side of RJ45 cable into RS485 communication port on lithium battery.
Note: If using a lithium battery, connect BMS communication cable and select "LIB-485" mode.
3.6. AC Input/Output Connection
⚠ Caution: Install a separate AC breaker between inverter and AC input source. Do NOT mis-connect input and output connectors.
Suitable cable specifications for AC wires:
| Model | Wire Gauge | Torque Value |
|---|---|---|
| 2.5KVA-12V | 1 * 12 AWG | 1.2-1.6 Nm |
| 3.5KVA-24V | 1 * 10 AWG | 1.2-1.6 Nm |
Steps:
- Open DC protector/disconnector first.
- Remove 10mm insulation sleeve for conductors. Shorten phase L and neutral N by 3mm.
- Insert AC input wires according to polarities (L: brown/black, N: blue) and tighten terminal screws.
- Insert AC output conductor according to polarity and tighten screw.
- Ensure wires are firmly connected.

3.7. PV Connection
⚠ Caution: Install a separate DC circuit breaker between inverter and PV module.
Recommended cable specifications for PV module connection:
| Model | Wire Gauge | Torque Value |
|---|---|---|
| 2.5KVA-12V | 1 * 14 AWG | 1.2-1.6 Nm |
| 3.5KVA-24V | 1 * 12 AWG | 1.2-1.6 Nm |
PV Module Selection Parameters:
- Open Circuit Voltage (Voc) of PV modules must not exceed max. PV array open circuit voltage of inverter (500Vdc).
- Open Circuit Voltage (Voc) of PV modules should be higher than min. battery voltage.
- PV Array MPPT Voltage Range: 55Vdc~450Vdc.
- Max. PV Array Power: 3000W (2.5KVA-12V), 4000W (3.5KVA-24V).
Steps:
- Remove 10mm insulation sleeve for positive and negative conductors.
- Check correct polarity of connection cable from PV modules and PV input connectors.
- Connect positive (+) to positive (+) and negative (-) to negative (-).
- Ensure wires are securely connected.
3.8. Final Assembly
After connecting all wires, replace the bottom cover and secure it with screws.
4. Operating
4.1. Power On/Off
After correct installation and battery connection, press the On/Off switch to turn on the inverter.
4.2. Operation and Display
The front panel features an LCD screen and four function keys for operation status and power information.
4.2.1. LED Indicators
| Indicator | Color | Status | Message |
|---|---|---|---|
| AC/INV | Green | Solid On | Output powered by utility (Line mode) |
| Flashing | Output powered by battery or PV | ||
| CHG | Green | Solid On | Battery fully charged |
| Flashing | Battery is charging | ||
| FAULT | Red | Solid On | Fault occurs in inverter |
| Flashing | Warning condition occurs |
4.2.2. Function Keys
- ESC: Exit setting mode.
- UP: Go to previous selection.
- DOWN: Go to next selection.
- ENTER: Confirm selection or enter setting mode.
4.2.3. LCD Display Icons
The LCD displays various icons indicating input source, configuration, fault information, output information, and battery status. Refer to the manual's LCD Display Icons section for detailed explanations of each icon.
4.3. LCD Setting
Press and hold "ENTER" for 3 seconds to enter setting mode. Use "UP" or "DOWN" to select programs, then "ENTER" to confirm or "ESC" to exit.
Key settings include:
- Program 00: Exit setting mode / One-button restore.
- Program 01: Output source priority (SUB, SBU, MKS).
- Program 02: Maximum charging current (10A to 100A).
- Program 03: AC input voltage range (Appliances, UPS).
- Program 04: Power saving mode enable/disable.
- Program 05: Battery type (AGM, Flooded, User-Defined, LIB-485).
- Program 09: Output frequency (50Hz/60Hz).
- Program 10: Output voltage (220V/230V/240V).
- Program 16: Charger source priority (Solar first, Solar and Utility, Only Solar).
- Program 30: Battery equalization enable/disable.
- Program 43: Lithium battery protocol (PYLON, PACE).
For a complete list of settings and their descriptions, refer to the "LCD Setting" section in the full PDF manual.
5. Maintenance
5.1. Clearance and Maintenance for Anti-Dust Kit
The inverter comes with a pre-installed anti-dust kit to protect internal components and enhance reliability. This kit should be cleaned monthly.
Steps:
- Remove the screws securing the anti-dust kit.
- Remove the dustproof case and take out the air filter foam.
- Clean the air filter foam and dustproof case.
- Re-assemble the dust-kit back to the inverter.

6. Troubleshooting
This section provides solutions to common issues. For persistent problems, contact support.
6.1. General Troubleshooting
| Problem | Explanation / Possible Cause | What to do |
|---|---|---|
| Unit shuts down during startup | Battery voltage too low | Re-charge or replace battery |
| No response after power on | Battery voltage too low or polarity reversed | Check connections, re-charge/replace battery |
| Mains exist but unit works in battery mode | Insufficient AC power quality | Check AC wire thickness, generator, input voltage range |
| Buzzer beeps continuously | Overload, short circuit, over temperature, fan fault, etc. | Refer to specific fault codes below |
6.2. Fault Codes
The inverter displays specific fault codes on the LCD. Refer to the full manual for a comprehensive list of Battery Alarm Codes, Battery Fault Codes, and General Fault Codes, along with their meanings and recommended actions.
6.3. Warning Codes
Warning codes indicate non-critical conditions that require attention. These are often accompanied by beeping patterns. Consult the full manual's "Warning Code" section for details.
7. Specifications
7.1. Table 1: Specification of LINE Mode
| Parameter | Value (3.5KVA-24V) |
|---|---|
| Input Voltage Waveform | Sinusoidal (utility or generator) |
| Nominal Input Voltage | 230Vac |
| Low Loss Voltage | 170Vac±7V (UPS), 90Vac±7V (Appliances) |
| High Loss Voltage | 280Vac±7V |
| Nominal Input Frequency | 50Hz / 60Hz (Auto detection) |
| Efficiency (Line Mode) | >95% (Rated R load, battery full charged) |
| Transfer Time | 10ms typical (UPS); 20ms typical (Appliances) |
7.2. Table 2: Specification of Inverter Mode
| Parameter | Value (3.5KVA-24V) |
|---|---|
| Rated Output Power | 2600VA/2600W |
| PV+Battery Rated Output Power | 3500VA/3500W |
| Output Voltage Waveform | Pure Sine Wave |
| Output Voltage Regulation | 230Vac±5% |
| Nominal DC Input Voltage | 24Vdc |
| Peak Efficiency | 92% |
| No Load Power Consumption | <25W |
| Saving Mode Power Consumption | <15W |
7.3. Table 3: Specification of Charging Mode
| Parameter | Value (3.5KVA-24V) |
|---|---|
| Charging Current (UPS) | 100A |
| Bulk Charging Voltage (Flooded) | 29.2V |
| Bulk Charging Voltage (AGM/Gel) | 28.2V |
| Floating Charging Voltage | 27Vdc |
| PV Array MPPT Voltage Range | 55V~450V |
| Max. PV Array Open Circuit Voltage | 500V |
| Max Charging Current | 100A |
7.4. Table 4: General Specifications
| Parameter | Value |
|---|---|
| Operating Temperature Range | 0°C to 55°C |
| Storage temperature | -15°C~ 60°C |
| Dimension (D*W*H), mm | 345*255*100 |
| Net Weight, kg | 4.6 |
8. User Tips
- Wi-Fi Monitoring: The inverter features integrated Wi-Fi for remote monitoring. Refer to the "Wi-Fi Plug Quick Installation Guideline" (not included in this manual, typically a separate document) to set up network and registration via mobile app or web page.
- Ease of Setup: Many users find the device straightforward to plug in and operate once connections are correctly made.
- Operating Modes: The inverter supports various operating modes, including powering loads directly from solar panels (Solar First mode) even without a battery, depending on configuration. Check LCD Program 01 (Output source priority) and Program 16 (Charger source priority) for detailed settings.
- Power Consumption: For consumption in power-saving or standby mode, refer to the "Saving Mode Power Consumption" in the Inverter Mode specifications (Table 2).
- Home Outlet Connection: The inverter is designed for integration into a solar power system with dedicated AC input/output wiring, not for direct connection to a standard home outlet. Ensure all AC connections are made by qualified personnel following safety guidelines.
9. Warranty and Support
For technical support, warranty claims, or service, please contact the manufacturer:
SHENZHEN HEHEJIN INDUSTRIAL CO.,LTD
- Tel/Fax: +86 755-28219903
- Email: support@powmr.com
- Web: www.powmr.com
- Address: Henggang Street, Longgang District, Shenzhen, Guangdong, China
Please have your model number (POW-HVM3.5KW) and purchase details ready when contacting support.