1. Introduction
The POWLAND 5KW 24V Hybrid Solar Inverter is a high-performance energy solution designed for modern European homes and professional off-grid applications. This inverter combines efficient pure sine wave technology with innovative dual AC output and the flexibility to operate with or without batteries, ensuring stable and intelligent power supply.
Its compact and lightweight design provides a stable and high-quality pure sine wave AC output, making it suitable for various household appliances. Whether used as a robust off-grid backup power source or for achieving household energy self-sufficiency, this inverter delivers reliable power.
Core Highlights
- Powerful Output, Unfazed by Loads: Features a rated power of 5kW/5kVA with a power factor of 1. It can handle solar and grid power loads simultaneously, with a maximum combined PV and AC charging current reaching 160A, easily meeting the needs of high-energy-consuming household appliances.
- Leading MPPT Tracking Technology: Equipped with a wide-range MPPT controller, featuring an operating voltage range of 60V~450V and a maximum PV open circuit voltage of 500Vdc, ensuring the system maximizes solar energy extraction under various lighting conditions.
- Ultimate Configuration Flexibility: Perfectly compatible with 24V nominal voltage lithium and lead-acid battery systems, and equipped with CAN/RS485 interfaces for BMS communication. The device can also work without a battery connected, significantly reducing initial setup and testing costs.
- Smart Cloud Monitoring: Supports an optional WIFI remote monitoring module, allowing real-time checking and management of your home energy system via a mobile APP or web portal.
2. Safety Precautions
Please read and understand all instructions and warnings in this manual before installing, operating, or maintaining this inverter. Failure to follow these instructions may result in electric shock, fire, severe injury, or death.
- Installation must be performed by qualified personnel in accordance with all local electrical codes and standards.
- Ensure all power sources (AC, PV, Battery) are disconnected before performing any wiring or maintenance.
- Do not disassemble the inverter. There are no user-serviceable parts inside.
- Keep the inverter away from flammable materials, moisture, and direct sunlight.
- Ensure proper ventilation around the inverter to prevent overheating.
- Wear appropriate personal protective equipment (PPE) when working with electrical systems.
Figure 2.1: Inverter Protection Features (Overload, Overheating, Battery, High Low Voltage, Short Circuit, Overcurrent, AntiReverse, Power Failure)
3. Product Overview
The POWLAND Hybrid Solar Inverter is designed for ease of use and robust performance. Below are the main components and their functions.
3.1 Physical Description and Dimensions
Figure 3.1: Front view of the POWLAND 5KW 24V Hybrid Solar Inverter, highlighting its key specifications.
Figure 3.2: Dimensions of the inverter: 410mm (Height), 336mm (Width), 115mm (Depth).
3.2 Components and Connection Ports
Figure 3.3: Rear panel view showing connection ports: AC IN, MAIN OUT1, SECOND OUT2, COM, BMS, BAT-, BAT+, PV IN, and ON/OFF switch.
- AC IN: AC input from utility grid or generator.
- MAIN OUT1: Primary AC output for essential loads.
- SECOND OUT2: Secondary AC output for non-essential loads or smart load management.
- COM: Communication port (RS232).
- BMS: Battery Management System communication port (RS485/CAN).
- BAT- / BAT+: Battery connection terminals.
- PV IN: Photovoltaic (solar panel) input terminals.
- ON/OFF: Power switch for the inverter.
3.3 LCD Display and LED Indicators
Figure 3.4: Product Overview showing the LCD display, function keys, and LED indicators.
Figure 3.5: Detailed explanation of LCD display icons and information.
| LED Indicator | State | Messages |
|---|---|---|
| AC / INV | Green Solid On | Output is powered by utility in Line mode. |
| Green Flashing | Output is powered by battery or PV in battery mode. | |
| CHG | Green Solid On | Battery is fully charged. |
| Green Flashing | Battery is charging. | |
| FAULT | Red Solid On | Fault occurs in the inverter. |
| Red Flashing | Warning condition occurs in the inverter. | |
| Function Key | Description | |
| ESC | To exit setting mode | |
| UP | To go to previous selection | |
| DOWN | To go to next selection | |
| ENTER | To confirm the selection in setting mode or enter setting mode | |
4. Installation
Proper installation is crucial for the safe and efficient operation of your hybrid solar inverter. Follow these guidelines carefully.
4.1 Mounting the Unit
Figure 4.1: System Diagram (Operation with battery connected) and Mounting the Unit instructions.
Consider the following points before selecting where to install:
- Do not mount the inverter on flammable construction materials.
- Mount on a solid surface.
- Install this inverter at eye level in order to allow the LCD display to be read at all times.
- The ambient temperature should be between 0°C and 55°C to ensure optimum operation.
- The recommended installation position is to be adhered to the wall vertically.
- Be sure to keep other objects and surfaces as shown in the right diagram to guarantee sufficient heat dissipation and to have enough space for removing wires.
SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.
4.2 Wiring Connections
All wiring should be done by a qualified electrician. Ensure all power sources are OFF before making any connections.
4.2.1 Solar System Connection
Figure 4.2: Solar System Connection Diagram, showing connections for Generator, Mains Power, WiFi module, AC Output (to appliances), Battery, and PV Array.
- PV Power: 5000W
- Max. PV Open Circuit Voltage: 450V
- PV MPPT Voltage Range: 60-450VDC
- Start-up Voltage (initial charging): >80V
- Suggested PV cable: 10AWG
- Max AC Input Voltage: 240Vac
- Charging Current: 160A
- Suggested AC Input cable: 10AWG
- Recommended AC Input breaker: 20A
- AC Output Power: 5000VA/5000W
- AC Output Voltage: 230Vac
- Suggested AC Output cable: 12AWG
- Recommended AC Output breaker: 20A
- Battery Type: Lead-Acid (Seal, AGM, Gel, Flooded) and Lithium battery
- Battery Voltage: 24V
- Battery Wire Size: 1AWG
- Battery Cable: 42mm²
NOTE: The output of the inverter is 230V.
4.2.2 PV Array Wiring Method
Figure 4.3: Solar photovoltaic panel wiring methods: Series connection (increases voltage) and Parallel connection (increases current).
- In Series: Increase the voltage of the system. This voltage needs to be less than the hybrid inverter's maximum PV input voltage Voc/inverter. The entire photovoltaic system should use the same type of photovoltaic panel.
- In Parallel: Parallel increases the current of the system. This current should not exceed the maximum PV input current of the hybrid inverter.
PV cable dimensions: 6-8A/mm²
4.2.3 Battery Connection
Figure 4.4: Battery Connection diagram for a 24V model, showing two 12V batteries connected in series with a fuse.
Connect all battery packs as shown in the diagram. The 5KW model supports a 24VDC system. Ensure correct polarity and use appropriate fusing.
5. Operation
This section outlines the basic operation and settings of your POWLAND Hybrid Solar Inverter.
5.1 Initial Startup
- After all connections are securely made, switch on the battery breaker (if a battery is connected).
- Switch on the PV array breaker.
- Switch on the AC input breaker (if connected to utility/generator).
- Turn the inverter's ON/OFF switch to the 'ON' position.
- The LCD display will light up, and the inverter will perform a self-test.
5.2 LCD Display and Settings
Use the ESC, UP, DOWN, and ENTER buttons to navigate through the LCD menu and adjust settings. Refer to Table 3.1 for button functions and Figure 3.5 for display icons.
The inverter offers various operating modes and parameters that can be configured to suit your specific energy needs, including battery charging priority, load source priority, and output voltage/frequency settings.
5.3 Battery-less Operation
This inverter supports operation without a battery connected. In this mode, the inverter can power loads directly from solar energy and/or the utility grid. This feature is ideal for reducing initial setup costs or for systems where battery storage is not required.
6. Wi-Fi Monitoring
The POWLAND Hybrid Solar Inverter supports optional Wi-Fi monitoring, allowing you to remotely monitor and control your system via a smartphone application.
Figure 6.1: Wi-Fi Monitoring setup, showing the inverter with an attached Wi-Fi module and QR codes for SmartESS (iOS and Android) app download.
6.1 Setup Instructions
- Purchase and install the optional Wi-Fi module into the designated port on the inverter.
- Download the SmartESS app by scanning the QR codes provided in Figure 6.1 or searching for "SmartESS" in your device's app store.
- Follow the in-app instructions to register an account and connect your inverter to your local Wi-Fi network.
- Once connected, you can monitor real-time data, view historical performance, and adjust certain settings remotely.
7. Maintenance
Regular maintenance ensures the longevity and optimal performance of your inverter. Always disconnect all power sources before performing any maintenance.
- Cleaning: Periodically clean the exterior of the inverter with a dry cloth. Ensure ventilation openings are free from dust and debris. Do not use liquid cleaners.
- Connections: Annually check all wiring connections for tightness and signs of corrosion. Loose connections can cause overheating and damage.
- Environment: Ensure the installation environment remains within the specified temperature and humidity ranges.
- Battery Check: If using batteries, follow the battery manufacturer's maintenance guidelines. Check battery terminals for corrosion and ensure proper ventilation in the battery compartment.
8. Troubleshooting
This section provides solutions to common issues you might encounter with your inverter. For more complex problems, please contact technical support.
8.1 Common Issues and Solutions
- Inverter Not Turning On:
- Check if the ON/OFF switch is in the 'ON' position.
- Verify battery connections and voltage.
- Ensure PV input and AC input breakers are closed.
- No AC Output:
- Check for fault indicators on the LCD.
- Ensure AC output breakers are closed.
- Verify that the load connected does not exceed the inverter's rated power.
- Low PV Charging:
- Check PV panel connections and ensure they are clean and free from shading.
- Verify PV input voltage and current on the LCD.
- Ensure PV array configuration (series/parallel) matches the inverter's specifications.
- Overload Warning/Fault:
- Reduce the connected load.
- Check for short circuits in the AC output wiring.
9. User Tips
Maximize the efficiency and lifespan of your POWLAND Hybrid Solar Inverter with these practical tips:
- Optimize PV Panel Placement: Ensure your solar panels are angled correctly for your latitude and free from any obstructions (trees, buildings) that could cause shading, especially during peak sunlight hours.
- Monitor Energy Consumption: Use the Wi-Fi monitoring feature to track your energy usage patterns. This can help you identify opportunities to shift high-consumption activities to times when solar production is high or utility rates are low.
- Regular System Checks: Periodically check the inverter's display for any warning or fault codes. Addressing minor issues promptly can prevent larger problems.
- Battery Health: If using batteries, ensure they are kept within their optimal temperature range and regularly check their state of charge. Proper battery care is key to system reliability.
10. Specifications
Detailed technical specifications for the POWLAND ISolar-SMS-5KW-24V-Wifi-PL Hybrid Solar Inverter.
Figure 10.1: Detailed specifications table for POWLAND ISolar-SMS-5KW-24V-Wifi-PL.
| Category | Parameter | Specification |
|---|---|---|
| AC Input | Rated Input Voltage (VAC) | 208/220/230/240; L+N+PE |
| Voltage Range (VAC) | 90-280 (APP/GEN mode); 170-264 (UPS mode) | |
| Frequency (Hz) | 50/60 (Auto Adaptive) | |
| AC Output | Rated Capacity (kVA/kW) | 5 (Output Power Rating will be reduced to 90% when setting the Output Voltage to 208V) |
| Surge Power (kVA) | 10 | |
| Voltage (VAC) | 208/220/230/240 | |
| Power Factor (PF) | 1.0 | |
| Frequency (Hz) | 50/60±0.1% | |
| WaveForm | Pure Sine Wave | |
| Charger (PV/AC) | Overload Capacity (Battery Mode) | 1min@102%-120% load, 10s@ >120% load |
| Max. Efficiency (Battery Mode) | 93.5%@24V | |
| Solar Charger Type | MPPT | |
| Max PV Input Current/Power | 27A / 9000W | |
| MPPT Range & Operating Voltage (VDC) | 60-450 | |
| PV Start-up Voltage (VDC) | 80 | |
| Max PV Open Circuit Voltage (VDC) | 500 | |
| Battery | Max PV Charge Current (A) | 160 |
| Max AC Charge Current (A) | 160 | |
| Max. Charge Current (PV+AC) (A) | 160 | |
| Normal Voltage (VDC) | 24 | |
| General Data | Battery Type | Lithium and Lead-acid |
| HMI | LCD | |
| Interface | RS485/CAN/RS232 | |
| Monitoring | WiFi (Optional) | |
| Ingress Protection | IP21 | |
| Operating Temperature | -10°C~50°C | |
| Relative Humidity | 5%~95% (Non-condensing) | |
| Storage Temperature | -15°C~60°C | |
| Max. Operating Altitude | 4000m (Derating above 2000m) |
11. Warranty and Support
POWLAND products are manufactured to high-quality standards and are backed by a manufacturer's warranty. For specific warranty terms and conditions, please refer to the warranty card included with your product or contact your point of purchase.
For technical support, troubleshooting assistance, or spare parts, please contact POWLAND customer service or your authorized dealer. When contacting support, please have your product model number (SMS-5KW-W-P) and serial number ready.