Mestek TI240

Contents

Mestek TI240 Rechargeable Thermal Imaging Camera User Manual

Model: TI240

1. Warning & Safety Information

▲ WARNING: Be aware of potential fire hazards and strictly follow the instruction manual for charging and storage. For disposal, please consult your local authority's website for further information and safely dispose of the lithium-ion battery in accordance with applicable legal requirements.

Do not use for extended periods under intense light.

2. Product Overview

The Mestek TI240 is a handheld infrared thermal imaging camera designed for a wide range of applications, including equipment maintenance, power testing, underfloor heating inspection, pipeline maintenance, electronic component testing, and automotive fault detection.

Mestek TI240 Handheld Infrared Thermal Imager showing thermal image of power lines

Figure 1: Mestek TI240 Handheld Infrared Thermal Imager

2.1 Key Features

  • Temperature Range: -20℃ to 550℃
  • Thermal Resolution: 240x240 pixels
  • Display: 2.4-inch HD color screen
  • Battery: Built-in 3200mAh long-lasting battery
  • Storage: Supports external SD memory card (standard 4GB SD card included)
  • Connectivity: USB Type-C for charging and data transfer
  • Imaging Modes: Six false-color modes (white hot, black hot, rainbow, iron red, red hot, fusion)
  • Temperature Tracking: Automatic tracking of hot and cold spots with alarm
  • Adjustable Emissivity: For accurate measurements on various surfaces
  • LED Light: High-power bright LED for emergency lighting in dark places
  • Language Support: English, Russian, French, Polish, Korean, Japanese, Italian, German, Chinese
  • Temperature Units: Celsius (℃), Fahrenheit (℉), Kelvin (K)
  • Certification: CE
Icons representing key features: USB Type-C, High and Low Temperature Alarm, SD Card (4GB), Long-lasting battery, Adjustable emissivity, Automatic Tracking of Hot and Cold Spots, Six false-color modes, 2.4-inch HD large screen, Custom Automatic Shutdown

Figure 2: Key Features Overview

3. Product Components

3.1 Device Layout

Diagram of the thermal imager showing numbered parts: 1. Display screen, 2. Button area, 3. Handheld area, 4. Lanyard hole, 5. Tripod mounting screw hole, 6. Type-C USB port, 7. SD card slot, 8. USB cover, 9. Protective cover, 10. Infrared imaging sensor, 11. Trigger button

Figure 3: Product Appearance and Components

NO.ComponentNO.Component
1Display screen6Type-C USB port
2Button area7SD card slot
3Handheld area8USB cover
4Lanyard hole9Protective cover
5Tripod mounting screw hole10Infrared imaging sensor
11Trigger button

3.2 Package Contents

Image showing the thermal imager, a fabric bag, color box, charging/data cable, lanyard, Chinese manual, and a 4GB SD card

Figure 4: Packaging Contents

  1. Thermal imaging main unit
  2. Fabric bag
  3. Color box
  4. Charging/data cable
  5. Lanyard
  6. Chinese manual (refer to this digital manual for English instructions)
  7. Standard 4GB SD card

4. Setup

4.1 Initial Charge

Before first use, fully charge the device using the provided USB Type-C cable and a compatible power adapter. The battery indicator on the display will show charging status.

4.2 SD Card Installation

Insert the provided 4GB SD card into the SD card slot (7) on the device. Ensure the USB cover (8) is properly closed after installation.

4.3 Powering On/Off

  • To power on: Press and hold the power button (part of the button area 2) until the display screen (1) illuminates.
  • To power off: Press and hold the power button until the device shuts down.

5. Operating Instructions

5.1 Basic Operation

  1. After powering on, point the device at the target object.
  2. Adjust focus if necessary to obtain a clear thermal image.
  3. The device will automatically display temperature data.
  4. Press the trigger button (11) to capture a photo or record video.

Video 1: Demonstration of the thermal imager in use, showing temperature detection and menu navigation.

5.2 Interface Symbols Description

Diagram of the thermal imager screen interface with numbered elements: 1. Center/Maximum/Minimum Temperature Values, 2. Track the Minimum Temperature Point on the Observation Screen, 3. Center Point of the Observation Screen, 4. Track the Maximum Temperature Point on the Observation Screen, 5. Date and Time, 6. Battery Level, 7. Pseudo-color Bar, 8. USB Cover, 9. Emissivity

Figure 5: Display Interface Symbols

NO.Description
1Center/Maximum/Minimum Temperature Values
2Track the Minimum Temperature Point on the Observation Screen
3Center Point of the Observation Screen
4Track the Maximum Temperature Point on the Observation Screen
5Date and Time
6Battery Level
7Pseudo-color Bar
8USB Cover
9Emissivity

5.3 Automatic Tracking of Hot and Cold Spots

The device can automatically track and highlight the hottest and coldest points within the observed area. You can set upper and lower temperature limits, and the device will alert you with a warning icon if these values are exceeded.

Thermal imager screen showing automatic tracking of hot and cold spots with temperature readings and warning icons

Figure 6: Automatic Hot and Cold Spot Tracking

5.4 False-Color Modes

The thermal imager offers six pseudo-color modes to enhance visual interpretation of temperature differences: White Hot, Black Hot, Rainbow, Iron Red, Red Hot, and Fusion. These modes can be selected via the menu to make temperature judgment clearer.

Screenshots of the thermal imager displaying six different false-color modes: Incandescence (White Hot), Black Heat (Black Hot), Rainbow, Iron Red, Red Hot, and Fusion. Instructions indicate pressing the up/down key to switch modes.

Figure 7: Six False-Color Imaging Modes

5.5 Adjustable Emissivity

Emissivity is a crucial factor for accurate temperature measurement. The device allows you to adjust the emissivity setting based on the surface material of the object being measured. Refer to the table below for common emissivity values.

Table showing emissivity values for common objects: Wet soil 0.95, Glass 0.94, Red brick 0.95, Skin 0.98, Water surface 0.95, White paper 0.93, Black cloth 0.98, Wood 0.87

Figure 8: Emissivity of Common Objects

5.6 Menu Navigation and Settings

Use the navigation buttons (up/down/OK) in the button area (2) to access and adjust settings. The main menu allows you to configure various parameters.

Screenshots of the thermal imager menu showing options for Color, Image parameters, Photo, Video, and Settings. Settings menu includes Auto power off, Brightness, Language Selection, Unit, Measure parameter, Temp range, Temp alarm, Time setting.

Figure 9: Menu Description and Settings

Menu ItemDescription/Options
Pseudo-colorSet the pseudo color mode to 'White Hot/Black Hot/Rainbow/Iron Red/Red Hot/Fusion'
Image parametersSet the thermal imaging effect mode to 'Enhanced/Standard/Soft'
PhotoView and delete photo files.
VideoPlay and delete video files.
Settings
  • Auto power off: Set to "Off/5 minutes/10 minutes/20 minutes/30 minutes".
  • Brightness: Set screen brightness to "Low/Medium/High".
  • Language settings: Set the language to Simplified Chinese/Traditional Chinese/English/Russian/Japanese/German/French/Italian/Korean/Polish.
  • Unit: Set the unit to Celsius (℃) / Fahrenheit (℉) / Kelvin (K).
  • Measurement Parameters:
    1. Ambient Temperature: Can be set in the range of -10℃ to 50℃.
    2. Temperature Measurement Distance: Can be set in the range of 0.3 to 3 m.
    3. Emissivity: Can be set in the range of 0.01 to 1; reference for emissivity values: 'Common Emissivity Table'.
  • Temperature Range: Set the temperature measurement range to: Low Range (-20℃~150℃) / High Range (100℃~550℃).
  • Temperature Alarm:
    1. High Temperature Alarm: On/Off, adjustable range -20℃~550℃.
    2. Low Temperature Alarm: On/Off, adjustable range -20℃~550℃.
    3. Alarm Automatic Photography: On/Off, automatic photography interval: adjustable 5s-30s. Number of Photos: adjustable 1-50.
  • Time Settings: Set the date, time, and time format.
  • Display settings: On/Off "Maximum temperature/Minimum temperature /Center point/Emissivity/Measuring distance/Date/Pseudo-color bar" function. UI is displayed on the main interface.
  • TISR: On/Off.
  • Restore Factory Settings: Restore to default settings.
  • Formatting: Format the device disk.
  • About equipment: Check 'Model /Firmware version/Application Version/SN/Disk Capacity'.

5.7 LED Lighting Lamp

The device features a high-power bright LED light for emergency lighting, making operation in dark places more convenient.

Thermal imager with its LED light illuminated, providing bright light in a dark environment

Figure 10: Highlight LED Lighting Lamp

6. Maintenance

  • Keep the device clean and free from dust and debris. Use a soft, dry cloth for cleaning.
  • Avoid exposing the device to extreme temperatures, humidity, or direct sunlight for prolonged periods.
  • Ensure the protective cover (9) is closed when the infrared imaging sensor (10) is not in use to prevent damage.
  • Store the device in its fabric bag when not in use to protect it from scratches and impacts.
  • Regularly check the USB Type-C port (6) and SD card slot (7) for any obstructions.

7. Troubleshooting

ProblemPossible Cause / Solution
Power-on failureCheck whether the battery is properly installed and sufficiently charged. Try charging the device for a period.
Unclear imageAdjust the focus of the lens. Ensure there are no obstructions between the sensor and the target. Clean the lens if dirty.
Inaccurate temperature readingsVerify the emissivity setting matches the material being measured. Ensure the measurement distance is within the recommended range (0.3 to 3m). Avoid measuring through glass or highly reflective surfaces.
Device unresponsivePerform a soft reset by holding the power button for an extended period (e.g., 10-15 seconds). If the issue persists, contact customer support.

8. Specifications

Detailed product specifications table for the thermal imager

Figure 11: Detailed Product Specifications

FeatureSpecification
Detector TypeVanadium Oxide (VOx) Microbolometer
Infrared Resolution240x240
Infrared Response Band8–14μm
Pixel Size12μm
Thermal Imaging Lens1.35mm
Focal Length8.89mrad
Frequency Detection25Hz
Thermal Sensitivity/NETD≤60 mK (@25℃, F#1.0)
Focusing MethodFocus-free
Display2.4 inch
Resolution240*320
Field of View50° x 50°
Measurement Range-20℃ ~ 550℃
Temperature Measurement Accuracy±2℃ or ±2% of reading, whichever is greater
Measurement Resolution0.1℃
Measurement ModeIndustrial Temperature Measurement
Measurement Unit℃/℉/K
Temperature DisplayCenter point, highest point, lowest point temperature measurement
Image/Video FormatJPEG/MP4
Temperature Analysis ToolPC Analysis Tool
Photo/Video RecordingSupported
LanguageSupports 10 languages
StorageExternal SD card (standard 4GB SD card)
Data InterfaceType-C
BatteryNon-removable 3200mAh / h
Charging Time≤4h
Device Power≤0.9W
Operating Time≥9h
Operating Temperature-10~50℃
Operating Humidity10%~90% RH non-condensing
Storage Temperature-20~60℃
IP RatingIP54
Drop Resistance1.5m
Device Weight (g)318g
Device Dimensions225mm*70mm*86.44mm

9. User Tips

  • For best results, ensure the target object fills a significant portion of the screen.
  • When measuring highly reflective surfaces, consider applying a matte tape or paint to the area to improve accuracy, or adjust the emissivity setting accordingly.
  • Utilize the different false-color modes to highlight specific temperature anomalies that might be less visible in other palettes.
  • The built-in LED light is useful for illuminating the visual scene in dark environments, complementing the thermal image.
  • Regularly back up your captured photos and videos from the SD card to prevent data loss.

10. Warranty and Support

For warranty information, technical support, or service inquiries, please contact your retailer or the manufacturer directly. Keep your proof of purchase for warranty claims.

Refer to the official website for the most up-to-date support resources and contact information.

A digital version of this user manual (PDF) is available for download: User Manual (PDF)

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.