1. Introduction and Overview
The ZIBOO 101 Mini Digital Multimeter is a high-tech, hand-held device featuring an ergonomic design and an LCD Backlight Display. It offers multi-functions, high precision, high performance, anti-drop capability, safety, and stability. This multimeter can accurately measure AC/DC voltage, AC/DC current, frequency, continuity, diodes, resistance, capacitance, and battery load. It also supports high voltage alarm and Non-Contact Voltage (NCV) detection. Equipped with misoperation circuit protection, it is suitable for professional electricians, electronic maintenance and repair work, DIY electronics hobbyists, homes, and factories.


2. Safety Precautions and Procedures
This product strictly follows the safety standards of European Electrotechnical Commission EN61010-1 and the technical design standard of China GBT_13978. Please read these safety precautions carefully before using the instrument and operate in strict accordance with the provisions.
- Always measure according to the specified range and do not rotate the gear during measurement to avoid damage from misoperation.
- To avoid possible electrical shock, do not touch live conductors exceeding 30V AC and 60V DC during measurement.
- When measuring AC and DC over 599V, a high voltage lightning symbol will display, and the buzzer will beep. Pay attention to measurement safety.
- Do not use the device in inflammable or explosive environments.
- To avoid measurement error, replace the battery immediately when the meter displays the low battery symbol.
- Before measuring, check the test pens and wires for damage or leakage. Do not use if any damage is found.
- Comply with national regulations and measurement safety standards. Wear insulating gloves or flame retardant products when measuring hazardous voltage.
3. What's in the Box
Upon opening your ZIBOO 101 Mini Digital Multimeter package, you should find the following items:
- ZIBOO 101 Mini Digital Multimeter
- Test Leads (Red and Black)
- User Manual (PDF available for download: User Manual PDF)

4. Product Appearance and Key Functions
The ZIBOO 101 Mini Digital Multimeter features a compact design with clearly labeled components for ease of use.

4.1. Appearance Description
- LCD Display: Shows measurement readings and icons.
- Function Key: Used for various settings and modes (e.g., HOLD, Backlight, MODE).
- Dial Switch: Selects the measurement function (e.g., OFF, 1.5V, 9V, V~, V-, Ω, NCV/LIVE, mA~, µA~).
- VΩ Voltage Resistance Current Red Test Pen Input: Positive input terminal for voltage, resistance, and current measurements.
- COM Common Ground Black Test Pen Input: Common ground input terminal for all measurements.

4.2. Icon Explanation
The multimeter's display and controls use various icons to indicate functions and status:
| Icon/Symbol | Function/Explanation |
|---|---|
| OFF | Turn off the power |
| Mountain | Auto shut off |
| Π | Low battery alert |
| (mV) | DC millivolt |
| V | DC voltage |
| TRUE RMS | True RMS measurement |
| ~V | AC voltage |
| Hz | Frequency |
| uA/mA | DC microampere/milliampere |
| uA/mA | AC microampere/milliampere |
| KΩ/MΩ | Resistance (Kilo-ohm/Mega-ohm) |
| Sound wave | Continuity beeper, diode test |
| nF/uF/mF | Capacitance (nanofarad/microfarad/millifarad) |
| Battery icon | Battery 1.5V/9V test |
| NCV EF | Non-contact sensing signal |
4.3. Key Functions
| Key | Function |
|---|---|
| MODE | Mode switch |
| HOLD | Data hold |
| Sun icon | Backlight |
4.4. International Electrical Symbols
| Symbol | Meaning |
|---|---|
| Exclamation mark in triangle | "Caution" indicates an operation that poses a risk |
| Lightning bolt in triangle | "High pressure" indicates a warning of high voltage danger |
| CE | EU uniform directive, EU CE certification |
| Ground symbol | Grounding |
| Double square | Double insulation or enhanced insulation protection |
| Crossed-out wheelie bin | Compliant with the WEEE Recycling Directive |
5. Operating Instructions
The ZIBOO 101 Multimeter offers various measurement functions. Use the dial switch to select the desired function and connect the test leads appropriately.
5.1. Dial Gear Functions

5.2. Measurement Examples
| Measurement | Test Pen Connection | Example/Description |
|---|---|---|
| ACV/Hz | Black to COM, Red to VΩ | AC Voltage (e.g., 220V, 380V/50Hz) |
| DCV | Black to COM, Red to VΩ | DC Voltage (e.g., Electric Vehicle 36V, 48V, Vehicle charging systems) |
| Continuity/Diode | Black to COM, Red to VΩ | Continuity buzzer beeps, Diode forward voltage (0.500-0.800V) |
| Resistance | Black to COM, Red to VΩ | SMD Resistors, Lead resistors |
| Capacitance | Black to COM, Red to VΩ | Chip Capacitors, Electrolytic Capacitors |
| NCV | Front end of the meter | Measures AC live wire, buzzer beeps and red LED flashes (FR101E) |
| LIVE | Red probe touches live wire | Live-wire testing (AC voltage), buzzer sounds continuously. |
| Battery Load | Black to COM, Red to VΩ | 1.5V battery, 9V battery |
| DCA/mA | Black to COM, Red to µA/mA | Meter pen series circuit measurement. Prohibited input AC 220V. |
| ACA/mA | Black to COM, Red to µA/mA | Meter pen series circuit measurement. Prohibited input AC 220V. |
| Current clamp 600A (AC/DC) | Black to COM, Red to VΩ | Select using Current clamp to measure AC/DC 600A. |
6. Specifications
Detailed technical specifications for the ZIBOO 101 Mini Digital Multimeter (FR101A and FR101E models).
6.1. General Technical Indicators
- Safety Rating: CAT II 600V
- Product Range: FR101A (manual), FR101E (automatic)
- Maximum Display: FR101A (2000 counts), FR101E (4000 counts)
- Sampling Rate: 3 times/second
- Overload Display: OL
- Auto Power Off: Approximately 15 minutes
- Operating Temperature: 0-40°C
- Precision: 23°C ± 5°C, 18-28°C, Humidity < 75% for 1 year
- Storage Temperature: -10-60°C, Humidity ≤ 80%
- Altitude: 0-2000M
- Pollution Grade: 2
- Safety Certification: CE EN61010-1-2-030
- Electromagnetic Environment: EN61326-1-2
- Battery-powered: AAA 1.5V × 2
- Dimensions: 130H x 66W x 33D mm
- Weight: 141g (Inclusive of battery)
6.2. Measurement Ranges and Accuracy
| Function | Range (FR101A) | Range (FR101E) | Resolution | Accuracy |
|---|---|---|---|---|
| DC Voltage | 200mV, 2V, 20V, 200V, 600V | 400mV, 4V, 40V, 400V, 600V | 0.1mV - 1V | ±(0.5%+3) |
| AC Voltage | 4V, 40V, 200V, 600V | 4V, 40V, 400V, 600V | 0.001V - 1V | ±(0.8%+3)/400Hz, ±(1.5%+5)/1KHz (FR101E) |
| ACV Frequency (FR101E) | N/A | 10Hz-40KHz (>5Vrms) | 0.01Hz - 0.01KHz | ±(0.5%+5) |
| Resistance | 200Ω, 2KΩ, 20KΩ, 200KΩ, 20MΩ | 400Ω, 4KΩ, 40KΩ, 400KΩ, 4M, 40MΩ | 0.1Ω - 0.01MΩ | ±(1%+5), ±(2%+5) |
| Capacitance (FR101E) | N/A | 4nF, 40nF, 400nF, 4uF, 40uF, 400uF, 4000uF | 0.001nF - 0.01mF | ±(4%+5), ±(8%+5) |
| DC Current | 200uA, 2000uA, 40mA, 200mA | 400uA, 4mA, 40mA, 400mA | 0.1uA - 0.1mA | ±(1%+5) |
| AC Current (FR101E) | N/A | 400uA, 4mA, 40mA, 400mA | 0.1uA - 0.1mA | ±(1%+5) |
| Battery Load | 1.5V, 9V | 1.5V, 9V | 0.001V, 0.01V | ±(2.5%+5) |
Input Protection:
- AC/DC Voltage, Resistance, Continuity/Diode/NCV, Capacitance: Impedance 10MΩ; 600Vrms, PTC Thermistor; 600Vrms
- DC/AC Current: Fused (200mA/500mA)/250V; Φ5x20mm (FR101A: 250mA, FR101E: 500mA)
7. Maintenance
Proper maintenance ensures the longevity and accuracy of your ZIBOO 101 Multimeter.
7.1. Replacing the Fuse
Warning: Disconnect the test pens from the circuit before replacing the fuse to avoid electric shock.
- Fuse Specification (FR101A): F1: 250mA/250V Φ5x20mm
- Fuse Specification (FR101E): F1: 500mA/250V Φ5x20mm
7.2. Replacing the Battery
The multimeter requires two AAA 1.5V batteries. The package will be sent without batteries.
Warning: Disconnect the test pens from the circuit before replacing the battery to avoid electric shock.
- Unscrew the battery cover located on the back of the device.
- Remove the old batteries.
- Insert two new AAA 1.5V batteries, ensuring correct polarity.
- Tightly screw the battery cover back into place. The meter can only be used normally after the cover is securely fastened.

7.3. Repair
If the device requires repair, it should be opened only by an approved and professionally experienced technician. If a fault cannot be resolved, please contact the official after-sales service. Non-professionals should not attempt repairs to avoid damage to the instrument or the risk of electric shock due to improper maintenance.
8. Troubleshooting
If you encounter issues with your ZIBOO 101 Multimeter, consider the following:
- No Display/Low Battery Indicator: Check and replace the AAA 1.5V batteries as described in the maintenance section.
- Inaccurate Readings: Ensure the correct function is selected on the dial. Verify test leads are properly connected and not damaged. If measuring high voltage, ensure safety precautions are followed.
- No Continuity Beep: Check if the continuity function is selected and if the circuit is indeed closed.
- Device Not Responding: Turn the device off and on again. If the issue persists, and you suspect a fuse problem, refer to the fuse replacement instructions (Section 7.1).
For persistent issues not resolved by these steps, please contact customer support.
9. User Tips
- Value for Money: Many users find this multimeter to offer excellent value, performing comparably to more expensive models.
- Portability: While compact, some users note it might be slightly larger than expected for a 'pocket' multimeter, but still highly portable.
- Battery Requirement: Remember that the device requires two 1.5V AAA batteries, which are typically not included in the package.
- Diode Measurement: One user noted that diode measurements might be less precise compared to voltage measurements. Keep this in mind for applications requiring high diode accuracy.
- Rotary Dial Beep: The rotary dial produces a beep sound when turned. Currently, there is no option to disable this sound.
10. Warranty and Support
For technical support, warranty claims, or service inquiries, please contact the manufacturer:
Guangzhou ZhengNeng Electronic Technology Co.,Ltd.Address: 4F, Building 6, Hongjie Industrial Area. Park, Baiyun TL Dist., Guangzhou, Guangdong, China
Tel: 020-37319325, 020-36544171, 020-36544172
Fax: 020-37319075
Post: 510540
Website: www.znele.com
The manufacturer is committed to addressing issues such as items lost during transit, damaged during transport, incorrect items shipped, or quality problems arising from actual use.