1. Introduction and Overview

The ZIBOO 101 Mini Digital Multimeter is a high-tech, hand-held device featuring an ergonomic design and an LCD Backlight Display. It offers multi-functions, high precision, high performance, anti-drop capability, safety, and stability. This multimeter can accurately measure AC/DC voltage, AC/DC current, frequency, continuity, diodes, resistance, capacitance, and battery load. It also supports high voltage alarm and Non-Contact Voltage (NCV) detection. Equipped with misoperation circuit protection, it is suitable for professional electricians, electronic maintenance and repair work, DIY electronics hobbyists, homes, and factories.

ZIBOO 101 Mini Digital Multimeter with features listed
ZIBOO 101 Mini Digital Multimeter highlighting its key features.
ZIBOO 101 Multimeter showing True RMS, NCV, Continuity Beeper, 1.5V/9V Battery Load, Lock Data, Auto Shutdown
Key features of the ZIBOO 101 Multimeter.

2. Safety Precautions and Procedures

This product strictly follows the safety standards of European Electrotechnical Commission EN61010-1 and the technical design standard of China GBT_13978. Please read these safety precautions carefully before using the instrument and operate in strict accordance with the provisions.

  • Always measure according to the specified range and do not rotate the gear during measurement to avoid damage from misoperation.
  • To avoid possible electrical shock, do not touch live conductors exceeding 30V AC and 60V DC during measurement.
  • When measuring AC and DC over 599V, a high voltage lightning symbol will display, and the buzzer will beep. Pay attention to measurement safety.
  • Do not use the device in inflammable or explosive environments.
  • To avoid measurement error, replace the battery immediately when the meter displays the low battery symbol.
  • Before measuring, check the test pens and wires for damage or leakage. Do not use if any damage is found.
  • Comply with national regulations and measurement safety standards. Wear insulating gloves or flame retardant products when measuring hazardous voltage.

3. What's in the Box

Upon opening your ZIBOO 101 Mini Digital Multimeter package, you should find the following items:

  • ZIBOO 101 Mini Digital Multimeter
  • Test Leads (Red and Black)
  • User Manual (PDF available for download: User Manual PDF)
Contents of the ZIBOO 101 Multimeter box: Multimeter, Test Leads, and packaging.
The ZIBOO 101 Multimeter and its included accessories.

4. Product Appearance and Key Functions

The ZIBOO 101 Mini Digital Multimeter features a compact design with clearly labeled components for ease of use.

Diagram of ZIBOO 101 Multimeter showing LCD Display, Function key, Dial switch, VΩ Voltage resistance current red test pen input, COM Common ground black test pen input.
Front view of the ZIBOO 101 Multimeter with labeled parts.

4.1. Appearance Description

  1. LCD Display: Shows measurement readings and icons.
  2. Function Key: Used for various settings and modes (e.g., HOLD, Backlight, MODE).
  3. Dial Switch: Selects the measurement function (e.g., OFF, 1.5V, 9V, V~, V-, Ω, NCV/LIVE, mA~, µA~).
  4. VΩ Voltage Resistance Current Red Test Pen Input: Positive input terminal for voltage, resistance, and current measurements.
  5. COM Common Ground Black Test Pen Input: Common ground input terminal for all measurements.
Product size diagram showing dimensions: 13cm/5.12in height, 6.6cm/2.6in width, 3.3cm/1.3in depth.
Dimensions of the ZIBOO 101 Multimeter.

4.2. Icon Explanation

The multimeter's display and controls use various icons to indicate functions and status:

Icon/SymbolFunction/Explanation
OFFTurn off the power
MountainAuto shut off
ΠLow battery alert
(mV)DC millivolt
VDC voltage
TRUE RMSTrue RMS measurement
~VAC voltage
HzFrequency
uA/mADC microampere/milliampere
uA/mAAC microampere/milliampere
KΩ/MΩResistance (Kilo-ohm/Mega-ohm)
Sound waveContinuity beeper, diode test
nF/uF/mFCapacitance (nanofarad/microfarad/millifarad)
Battery iconBattery 1.5V/9V test
NCV EFNon-contact sensing signal

4.3. Key Functions

KeyFunction
MODEMode switch
HOLDData hold
Sun iconBacklight

4.4. International Electrical Symbols

SymbolMeaning
Exclamation mark in triangle"Caution" indicates an operation that poses a risk
Lightning bolt in triangle"High pressure" indicates a warning of high voltage danger
CEEU uniform directive, EU CE certification
Ground symbolGrounding
Double squareDouble insulation or enhanced insulation protection
Crossed-out wheelie binCompliant with the WEEE Recycling Directive

5. Operating Instructions

The ZIBOO 101 Multimeter offers various measurement functions. Use the dial switch to select the desired function and connect the test leads appropriately.

Demonstration of various measurement functions of the ZIBOO 101 Multimeter, including NCV, short circuit buzzing, capacitive testing, resistance testing, AC/DC current/voltage tests, and battery load tests.

5.1. Dial Gear Functions

Diagram showing the dial switch positions for various functions: OFF, V~ (AC Voltage), Hz (Frequency), Diode/Continuity, Capacitance, NCV/LIVE, A~ (AC Current), Ω (Resistance), µA/mA (Current), 1.5V/9V (Battery Test), V- (DC Voltage).
Overview of the dial switch functions.

5.2. Measurement Examples

MeasurementTest Pen ConnectionExample/Description
ACV/HzBlack to COM, Red to VΩAC Voltage (e.g., 220V, 380V/50Hz)
DCVBlack to COM, Red to VΩDC Voltage (e.g., Electric Vehicle 36V, 48V, Vehicle charging systems)
Continuity/DiodeBlack to COM, Red to VΩContinuity buzzer beeps, Diode forward voltage (0.500-0.800V)
ResistanceBlack to COM, Red to VΩSMD Resistors, Lead resistors
CapacitanceBlack to COM, Red to VΩChip Capacitors, Electrolytic Capacitors
NCVFront end of the meterMeasures AC live wire, buzzer beeps and red LED flashes (FR101E)
LIVERed probe touches live wireLive-wire testing (AC voltage), buzzer sounds continuously.
Battery LoadBlack to COM, Red to VΩ1.5V battery, 9V battery
DCA/mABlack to COM, Red to µA/mAMeter pen series circuit measurement. Prohibited input AC 220V.
ACA/mABlack to COM, Red to µA/mAMeter pen series circuit measurement. Prohibited input AC 220V.
Current clamp 600A (AC/DC)Black to COM, Red to VΩSelect using Current clamp to measure AC/DC 600A.

6. Specifications

Detailed technical specifications for the ZIBOO 101 Mini Digital Multimeter (FR101A and FR101E models).

6.1. General Technical Indicators

  • Safety Rating: CAT II 600V
  • Product Range: FR101A (manual), FR101E (automatic)
  • Maximum Display: FR101A (2000 counts), FR101E (4000 counts)
  • Sampling Rate: 3 times/second
  • Overload Display: OL
  • Auto Power Off: Approximately 15 minutes
  • Operating Temperature: 0-40°C
  • Precision: 23°C ± 5°C, 18-28°C, Humidity < 75% for 1 year
  • Storage Temperature: -10-60°C, Humidity ≤ 80%
  • Altitude: 0-2000M
  • Pollution Grade: 2
  • Safety Certification: CE EN61010-1-2-030
  • Electromagnetic Environment: EN61326-1-2
  • Battery-powered: AAA 1.5V × 2
  • Dimensions: 130H x 66W x 33D mm
  • Weight: 141g (Inclusive of battery)

6.2. Measurement Ranges and Accuracy

FunctionRange (FR101A)Range (FR101E)ResolutionAccuracy
DC Voltage200mV, 2V, 20V, 200V, 600V400mV, 4V, 40V, 400V, 600V0.1mV - 1V±(0.5%+3)
AC Voltage4V, 40V, 200V, 600V4V, 40V, 400V, 600V0.001V - 1V±(0.8%+3)/400Hz, ±(1.5%+5)/1KHz (FR101E)
ACV Frequency (FR101E)N/A10Hz-40KHz (>5Vrms)0.01Hz - 0.01KHz±(0.5%+5)
Resistance200Ω, 2KΩ, 20KΩ, 200KΩ, 20MΩ400Ω, 4KΩ, 40KΩ, 400KΩ, 4M, 40MΩ0.1Ω - 0.01MΩ±(1%+5), ±(2%+5)
Capacitance (FR101E)N/A4nF, 40nF, 400nF, 4uF, 40uF, 400uF, 4000uF0.001nF - 0.01mF±(4%+5), ±(8%+5)
DC Current200uA, 2000uA, 40mA, 200mA400uA, 4mA, 40mA, 400mA0.1uA - 0.1mA±(1%+5)
AC Current (FR101E)N/A400uA, 4mA, 40mA, 400mA0.1uA - 0.1mA±(1%+5)
Battery Load1.5V, 9V1.5V, 9V0.001V, 0.01V±(2.5%+5)

Input Protection:

  • AC/DC Voltage, Resistance, Continuity/Diode/NCV, Capacitance: Impedance 10MΩ; 600Vrms, PTC Thermistor; 600Vrms
  • DC/AC Current: Fused (200mA/500mA)/250V; Φ5x20mm (FR101A: 250mA, FR101E: 500mA)

7. Maintenance

Proper maintenance ensures the longevity and accuracy of your ZIBOO 101 Multimeter.

7.1. Replacing the Fuse

Warning: Disconnect the test pens from the circuit before replacing the fuse to avoid electric shock.

  • Fuse Specification (FR101A): F1: 250mA/250V Φ5x20mm
  • Fuse Specification (FR101E): F1: 500mA/250V Φ5x20mm

7.2. Replacing the Battery

The multimeter requires two AAA 1.5V batteries. The package will be sent without batteries.

Warning: Disconnect the test pens from the circuit before replacing the battery to avoid electric shock.

  1. Unscrew the battery cover located on the back of the device.
  2. Remove the old batteries.
  3. Insert two new AAA 1.5V batteries, ensuring correct polarity.
  4. Tightly screw the battery cover back into place. The meter can only be used normally after the cover is securely fastened.
Diagram showing the battery compartment and how to insert two AAA 1.5V batteries.
Battery replacement diagram.

7.3. Repair

If the device requires repair, it should be opened only by an approved and professionally experienced technician. If a fault cannot be resolved, please contact the official after-sales service. Non-professionals should not attempt repairs to avoid damage to the instrument or the risk of electric shock due to improper maintenance.

8. Troubleshooting

If you encounter issues with your ZIBOO 101 Multimeter, consider the following:

  • No Display/Low Battery Indicator: Check and replace the AAA 1.5V batteries as described in the maintenance section.
  • Inaccurate Readings: Ensure the correct function is selected on the dial. Verify test leads are properly connected and not damaged. If measuring high voltage, ensure safety precautions are followed.
  • No Continuity Beep: Check if the continuity function is selected and if the circuit is indeed closed.
  • Device Not Responding: Turn the device off and on again. If the issue persists, and you suspect a fuse problem, refer to the fuse replacement instructions (Section 7.1).

For persistent issues not resolved by these steps, please contact customer support.

9. User Tips

  • Value for Money: Many users find this multimeter to offer excellent value, performing comparably to more expensive models.
  • Portability: While compact, some users note it might be slightly larger than expected for a 'pocket' multimeter, but still highly portable.
  • Battery Requirement: Remember that the device requires two 1.5V AAA batteries, which are typically not included in the package.
  • Diode Measurement: One user noted that diode measurements might be less precise compared to voltage measurements. Keep this in mind for applications requiring high diode accuracy.
  • Rotary Dial Beep: The rotary dial produces a beep sound when turned. Currently, there is no option to disable this sound.

10. Warranty and Support

For technical support, warranty claims, or service inquiries, please contact the manufacturer:

Guangzhou ZhengNeng Electronic Technology Co.,Ltd.
Address: 4F, Building 6, Hongjie Industrial Area. Park, Baiyun TL Dist., Guangzhou, Guangdong, China
Tel: 020-37319325, 020-36544171, 020-36544172
Fax: 020-37319075
Post: 510540
Website: www.znele.com

The manufacturer is committed to addressing issues such as items lost during transit, damaged during transport, incorrect items shipped, or quality problems arising from actual use.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.