1. Introduction
Thank you for choosing the SNDWAY SW-32A or SW-32B Optical Automatic Leveling Instrument. This manual provides essential information for the correct setup, operation, maintenance, and troubleshooting of your device. Please read it thoroughly before using the instrument to ensure optimal performance and longevity.
The SNDWAY SW-32A and SW-32B are precision optical instruments designed for accurate leveling in various outdoor engineering and construction applications. Both models feature 32x magnification, an automatic compensator for quick and precise leveling, and a robust design suitable for challenging environments.
2. Package Contents
Upon unpacking, please verify that all items listed below are present and in good condition. The specific contents may vary slightly based on the purchased configuration (SW-32A or SW-32B, with or without tripod and staff).
- SNDWAY SW-32A or SW-32B Optical Automatic Leveling Instrument
- Instruction Manual
- Product Certificate
- Hex Wrench (for adjustments)
- Carrying Case (Yellow for SW-32A, Red for SW-32B)
- (Optional) Thickened Tripod
- (Optional) 5-meter Leveling Staff (Tower Ruler)


3. Setup
3.1 Tripod Setup
- Extend the tripod legs to a suitable height, ensuring the tripod head is roughly level.
- Firmly press the tripod legs into the ground to ensure stability.
- Adjust the tripod legs so that the tripod head is as close to level as possible.
3.2 Mounting the Level
- Carefully remove the leveling instrument from its carrying case.
- Place the instrument onto the tripod head, aligning the central screw with the instrument's base.
- Tighten the central screw securely to attach the instrument to the tripod. Do not overtighten.
3.3 Initial Leveling
- Roughly level the instrument using the circular bubble level. Adjust the tripod legs until the bubble is centered.
- For fine leveling, rotate the instrument so the main telescope is parallel to two of the leveling screws.
- Adjust these two leveling screws simultaneously (inward or outward) until the circular bubble is centered.
- Rotate the instrument 90 degrees and adjust the third leveling screw until the bubble is centered.
- Repeat these steps if necessary until the bubble remains centered in all directions.
3.4 Compensator Check
The instrument is equipped with an automatic compensator. Once the circular bubble is centered, the compensator will automatically fine-level the line of sight within its working range (±15'). To check its function, gently tap the tripod or instrument. The reticle should briefly oscillate and then quickly return to a stable position.
4. Operating Instructions
4.1 Focusing
- Point the telescope towards a bright background (e.g., the sky).
- Adjust the eyepiece focus ring until the reticle (crosshairs) appears sharp and clear. This adjustment is personal and should be done by each user.
- Point the telescope towards the leveling staff.
- Rotate the objective lens focusing knob until the image of the staff appears sharp and clear.
4.2 Taking Readings
- Ensure the instrument is level and focused on the leveling staff.
- Read the value on the staff where the horizontal crosshair intersects it.
- For distance measurement, use the upper and lower stadia hairs. Multiply the difference between the upper and lower stadia readings by 100 to get the distance in meters.
4.3 Horizontal Angle Measurement
The instrument features a horizontal circle for measuring angles.
- Loosen the horizontal clamp screw.
- Rotate the instrument to align the 0 mark of the horizontal circle with your starting point or reference.
- Tighten the horizontal clamp screw.
- Rotate the instrument to your target point using the horizontal fine adjustment knob.
- Read the angle directly from the horizontal circle.

5. Maintenance
5.1 Cleaning
- Lenses: Use a soft, lint-free cloth or lens paper and a specialized lens cleaning solution. Gently wipe the lenses to remove dust and smudges. Avoid touching the lenses with your fingers.
- Instrument Body: Wipe the body with a soft, damp cloth. Do not use abrasive cleaners or solvents.
- Dust and Water Resistance: The instrument is designed to be dustproof and waterproof. However, after use in wet or dusty conditions, it is recommended to clean and dry the instrument thoroughly before storage.
5.2 Storage
- Always store the instrument in its original carrying case when not in use.
- Ensure the case is closed securely to protect against dust, moisture, and impact.
- Store the case in a dry, cool, and dust-free environment, away from direct sunlight and extreme temperatures.
5.3 Calibration
While the instrument is factory-calibrated for precision, long-term use or significant impacts may affect its accuracy. If you suspect a deviation in accuracy, it is recommended to have the instrument professionally checked and recalibrated by a qualified service center.

6. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Instrument inaccurate after long use | Compensator structure unstable, poor shock absorption, or internal component wear. | The compensator determines accuracy. If accuracy drifts, professional calibration is required. |
| Unclear view through telescope | Lenses are dirty, eyepiece/objective not focused correctly. | Clean lenses with appropriate materials. Adjust eyepiece and objective focus knobs until image is sharp. |
| Circular bubble not centering | Tripod not stable, instrument not properly leveled. | Ensure tripod is firmly set. Re-level the instrument using tripod legs and leveling screws. |
| Reticle (crosshairs) not stable | Compensator malfunction or instrument not level. | Ensure instrument is level. If instability persists, the compensator may need service. |

7. Specifications
| Feature | SW-32A | SW-32B |
|---|---|---|
| Body Material | Metal + Plastic | Metal |
| Optics Type | Small Optics (38mm) | Large Optics (42mm) |
| Magnification | 32x | |
| Image | Erect | |
| Minimum Focusing Distance | 1m | 0.6m |
| Standard Deviation (1km double-run) | ±1.5mm | |
| Field of View | 1°20' | |
| Compensator Range | ±15' | |
| Horizontal Circle Graduation | 1° | |
| Compensator Type | Air-damped (Automatic) | |
| Dust/Water Resistance | Yes (Designed for outdoor use) | |
| Approx. Package Weight | 5.0 kg | |

8. User Tips
- Stability First: Always ensure your tripod is firmly planted and stable before mounting the instrument. This is crucial for accurate readings.
- Check the Bubble: Before every measurement session, double-check that the circular bubble is perfectly centered. Even slight deviations can affect accuracy.
- Protect the Optics: When not actively observing, keep the lens caps on to protect the delicate optics from dust, scratches, and direct sunlight.
- Regular Cleaning: Make it a habit to gently clean the lenses after each use, especially in dusty or humid environments.
- Practice Focusing: Practice adjusting both the eyepiece and objective focus until you can quickly achieve a sharp image and reticle.
9. Warranty and Support
For warranty information, technical support, or service inquiries, please contact your original seller or authorized distributor. Keep your purchase receipt as proof of purchase. Do not attempt to repair the instrument yourself, as this may void the warranty and cause further damage.