About This Manual
Purpose
This manual describes the assembly, installation, operation, and troubleshooting of this unit. Please read this manual carefully before installations and operations. Keep this manual for future reference.
Scope
This manual provides safety and installation guidelines as well as information on tools and wiring.
Safety Instructions
WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.
- Before using the unit, read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual.
CAUTION – To reduce risk of injury, charge only deep-cycle lead acid type rechargeable batteries. Other types of batteries may burst, causing personal injury and damage.
- Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
- To reduce risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
CAUTION - Only qualified personnel can install this device with battery.
- NEVER charge a frozen battery.
- For optimum operation of this inverter/charger, please follow required spec to select appropriate cable size. It's very important to correctly operate this inverter/charger.
- Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts and could cause an explosion.
- Please strictly follow installation procedure when you want to disconnect AC or DC terminals. Please refer to INSTALLATION section of this manual for the details.
- Fuse is provided as over-current protection for the battery supply.
- GROUNDING INSTRUCTIONS - This inverter/charger should be connected to a permanent grounded wiring system. Be sure to comply with local requirements and regulation to install this inverter.
- NEVER cause AC output and DC input short circuited. Do NOT connect to the mains when DC input short circuits.
Warning!! Only qualified service persons are able to service this device. If errors still persist after following troubleshooting table, please send this inverter/charger back to local dealer or service center for maintenance.
Product Overview
The ANENJI 5KW 48V Hybrid Solar Inverter/Charger is a versatile unit designed for solar power systems, offering both on-grid and off-grid capabilities. It features a pure sine wave output, dual AC outputs, and a 100A MPPT solar charge controller. The inverter supports lithium battery activation and includes Wi-Fi for remote monitoring via an app. Its robust design ensures stable and efficient power conversion for various applications.
Key Features
- Dual output for smart load management
- Lithium battery activation function by PV or Utility
- Colored LCD with RGB lights
- Compatible with LiFePO4 battery via RS485
- PV input up to 500Vdc Max
- Built-in MPPT 100A
- Capable to work without battery
- Detachable dust cover for harsh environments
- Built-in Wifi remote monitoring
- Support multiple output priority: UTL, SOL, SBU, SUB
- EQ function to optimize battery performance and extend lifecycle
- Pure sine wave output for stable power
- Low-noise operation (approx. 45dB)
- Multiple protection functions: Short-circuit, Surge, Overload, Over-Temp, Low Voltage, High Voltage

This diagram shows the front and bottom panels of the inverter, highlighting the LCD display, function buttons, RGB indicator, power on/off switch, battery input, AC input, main output, second output, WiFi antenna port, RS485 communication port, grounding, and PV input.

This image summarizes the key features of the inverter, including pure sine wave, dual outputs, 100A MPPT, colored LCD, PV 60-500Vdc, lithium battery activation, BMS compatibility, capability to work without battery, detachable dust cover, multiple output priority, WiFi remote monitoring, and battery optimization function.

Illustrates the inverter providing high-quality AC power to common household appliances such as computers, refrigerators, TVs, and water heaters, emphasizing its stable output and high compatibility.

This image highlights the inverter's noise reduction technology, showing comparative noise levels: Library (15db), Inverter (45db), Voices (60db), Alarm clock (80db), indicating quiet operation.

This graphic illustrates the multiple protection features of the inverter, including short-circuit protection, surge protection, overload protection, over-temperature protection, low voltage protection, and high voltage protection, ensuring safer and more reliable use.
Setup (Installation)
Unpacking and Inspection
Before installation, please inspect the unit. Ensure that nothing inside the package is damaged. The package should contain:
- The inverter unit x 1
- User manual x 1
- PV connector x 2
- WiFi antenna x 1
Preparation
Before connecting all wirings, remove the bottom cover by unscrewing the three or two screws as shown in the product overview diagram.
Mounting the Unit
Consider the following points when selecting an installation location:
- Do not mount the inverter on flammable construction materials.
- Mount on a solid surface.
- Install this inverter at eye level for easy LCD display readability.
- The ambient temperature should be between 0°C and 55°C for optimal operation.
- The recommended installation position is vertically on the wall.
- Ensure sufficient heat dissipation and space for wiring by keeping other objects and surfaces clear, as shown in the diagram below.
Note: Suitable for mounting on concrete or other non-combustible surfaces only.
Battery Connection
CAUTION: For safety and regulation compliance, install a separate DC over-current protector or disconnect device between the battery and inverter. Refer to the typical amperage table for required fuse or breaker size.
WARNING: All wiring must be performed by qualified personnel. Use appropriate cable for battery connection to reduce risk of injury.
Follow these steps for battery connection:
- Make positive and negative cables based on recommended terminal size.
- Connect all battery packs as required by the unit.
- Insert battery cable flatly into the battery connector of the inverter and ensure bolts are tightened with a torque of 4~6Nm. Verify correct polarity at both the battery and the inverter/charger.
AC Input/Output Connection
CAUTION: Before connecting to an AC input power source, install a separate AC breaker (recommended 50A) between the inverter and the AC input power source. This ensures the inverter can be securely disconnected during maintenance and protected from overcurrent. Do not mis-connect input and output connectors.
WARNING: All wiring must be performed by qualified personnel. Use appropriate cable for AC input connection. Refer to the suggested cable requirement table for AC wires.
Follow these steps for AC input/output connection:
- Before making AC input/output connection, ensure the DC protector or disconnector is open.
- Remove 10mm of insulation sleeve for six conductors. Shorten phase L and neutral conductor by 3mm.
- Insert AC input wires according to polarities (Ground, L, N) indicated on the terminal block and tighten the terminal screws. Connect the PE protective conductor first.
WARNING: Ensure the AC power source is disconnected before attempting to hardwire it to the unit.
- Insert AC output wires according to polarities indicated on the terminal block and tighten terminal screws. Connect the PE protective conductor first.
- Ensure all wires are securely connected.
CAUTION: Important: Connect AC wires with correct polarity. Reversed L and N wires can cause utility short-circuiting when inverters operate in parallel.
CAUTION: Appliances like air conditioners require 2-3 minutes to restart. If power shortages occur and recover quickly, it can damage connected appliances. Check if your air conditioner has a time-delay function. The inverter may trigger overload fault to protect appliances, but internal damage can still occur.
PV Connection
CAUTION: Before connecting to PV modules, install a separate DC circuit breaker between the inverter and PV modules.
WARNING: All wiring must be performed by qualified personnel. Use appropriate cable for PV module connection. Refer to the suggested cable requirement table for PV wires.

This diagram illustrates a typical solar power system setup, showing the connection of solar panels, inverter, power grid, battery, and generator to a household. It also provides key parameters for PV module selection: Max. PV Array Power 5000W, Max. Solar Charge Current 100A, Max. PV Array Open Circuit Voltage 500VDC.
Follow these steps for PV module connection:
- Remove 6mm of insulation sleeve for positive and negative conductors.
- Check correct polarity of connection cable from PV modules and PV input connectors. Connect positive (+) to positive (+) and negative (-) to negative (-).
- Ensure the wires are securely connected.
Final Assembly
After connecting all wirings, replace the bottom cover by screwing in the two screws.
This video demonstrates the wiring process for the ANJ-5KW-48V-WIFI Solar Inverter, including removing the port cover, connecting the main AC output, connecting the battery, reinstalling the port cover, and turning on the inverter.
Operating
Power ON/OFF
Once the unit has been properly installed and the batteries are connected, simply press the On/Off switch (located on the side of the case) to turn on the unit.
Operation and Display Panel
The inverter's front panel features an LCD display, three indicators, and four function keys to show operating status and power information.
RGB Indicator Messages
| Mode | RGB Indicator | Messages |
|---|---|---|
| Inverter mode | Green Solid On | Output is powered by battery or PV in battery mode. Battery is fully charged or isn't charged. |
| Green Flashing | Battery is charging with 2s-on and 1s-off. | |
| AC mode | Blue Solid On | Output is powered by AC or PV in AC mode. Battery is fully charged or isn't charged. |
| Blue Flashing | Battery is charging with 2s-on and 1s-off. | |
| Standby mode | Cyan Solid On | Battery is fully charged or isn't charged. |
| Cyan Flashing | Battery is charging with 2s-on and 1s-off. | |
| Fault mode | Red Solid On | Fault occurs in the inverter. |
| Bypass mode | Purple Solid On | Working in AC mode without charging. |
| Charging mode | Yellow Solid On | Battery is fully charged, when switch is off. |
| Yellow Flashing | Battery is charging, when switch is off. |
Function Keys
| Function Key | Description |
|---|---|
| ESC | To exit setting mode |
| UP | To go to previous selection |
| DOWN | To go to next selection |
| ENTER | To confirm the selection in setting mode or enter setting mode |
LCD Display Description
The LCD display information can be switched by pressing keys. Information is shown in five areas:
- Area 1: PV data (voltage, current, power).
- Area 2: Battery data (voltage, current, power, SOC).
- Area 3: AC output data (voltage, current, power, percentage, frequency).
- Area 4: AC input data (voltage, current, power, percentage, frequency).
- Area 5: Setting program code, Eco/buzzer/error/warning.
LCD Data Polling Display Mode
- Simultaneously polling data: Press "UP" or "DOWN" to show all data from area 1 to area 4 simultaneously. All data updates with pressing. Press ESC to return to initial data.
- Independent polling data: Data of areas 1-4 can be polled independently:
- Press "Enter", circle icon of area 1 flashes. Use "UP" or "DOWN" to display data of area 1.
- Continue pressing "Enter", circle icon of area 2 flashes. Use "UP" or "DOWN" to display data of area 2.
- Continue pressing "Enter", circle icon of area 3 flashes. Use "UP" or "DOWN" to display data of area 3.
- Continue pressing "Enter", circle icon of area 4 flashes. Use "UP" or "DOWN" to display data of area 4.
- Continue pressing "Enter", circle icon of area 1 flashes, returning to the beginning.
LCD Setting
Press and hold the "Enter" key for 3 seconds to enter setting mode. Use "UP" or "DOWN" to select programs, then "ENTER" to confirm or "ESC" to exit. The LCD will show the setting program code, minimum/maximum values, program item, and current settable value.
For detailed setting programs, refer to the comprehensive tables in the full user manual (PDF) available at User Manual (PDF).
Battery Equalization
The equalization function reverses the buildup of negative chemical effects like stratification and removes sulfate crystals, extending battery life. To apply equalization:
- Enable battery equalization in monitoring LCD setting program 33.
- Set equalization interval in program 37, or activate immediately in program 39.
The controller enters Equalize stage when the set interval is reached or immediately activated. It charges the battery until it reaches the equalization voltage, then maintains it at that voltage until the set equalized time is reached. If the voltage doesn't rise sufficiently, the equalized time may be extended. If still low after timeout, equalization stops, and the system returns to float stage.
Setting for Lithium Battery
If using a lithium battery, ensure it's a configured type. Two connectors are on the lithium battery: RS485 port of BMS and power cable.
Follow these steps for lithium battery connection:
- Assemble battery terminals based on recommended cable and terminal size (same as Lead acid).
- Connect the RS485 port of the battery to the BMS (RS485) communication port of the inverter.
The communication cable delivers information and signals between the lithium battery and the inverter, allowing for re-configuration of charging voltage, charging current, and battery discharge cut-off voltage according to lithium battery parameters. The inverter can start or stop charging based on the lithium battery status.
For PYLON US2000 lithium battery setting:
- Dip Switch: 4 Dip Switches set baud rate and battery group address. 'ON' is '1', 'OFF' is '0'. Dip 1 'ON' for baud rate 9600. Dips 2, 3, 4 are for battery group address.
- Installation Process:
- Use the RS485 cable to connect the inverter and Lithium battery.
- Switch on the Lithium battery.
- Press for more than three seconds to start the Lithium battery; power output ready.
- Turn on the inverter.
- Select battery type as "Li2" in LCD program 5.
If communication is successful, the battery icon 'LI' on the LCD display will light up.
For lithium battery without communication, refer to the full user manual (PDF) for detailed settings to avoid BMS protection.
Maintenance
Regular maintenance is crucial for the longevity and optimal performance of your ANENJI Hybrid Solar Inverter. Always ensure the unit is powered off and all wirings are disconnected before attempting any maintenance or cleaning to prevent electric shock.
- Cleaning: Keep the inverter's exterior clean and free from dust. The detachable dust cover can be removed for cleaning.
- Ventilation: Ensure that the inverter's ventilation openings are clear and not blocked to allow for proper heat dissipation.
- Wiring Inspection: Periodically check all wiring connections (battery, AC input/output, PV input) for tightness and signs of wear or damage. Ensure no anti-oxidant substance is applied to terminals before tightening.
- Battery Health: Monitor battery voltage and performance. If using lead-acid batteries, consider using the battery equalization function periodically to prevent sulfation.
- Firmware Updates: Check the manufacturer's website or app for any available firmware updates for the inverter or Wi-Fi module to ensure optimal performance and compatibility.
WARNING: Only qualified service personnel should perform complex maintenance or repairs. Do not attempt to disassemble the unit yourself.
Troubleshooting
This section provides guidance for common issues. If problems persist, contact a qualified service person.
Fault Reference Code
| Fault Code | Fault Event |
|---|---|
| 01 | Over temperature of inverter module |
| 02 | Over temperature of DCDC module |
| 03 | Battery voltage is too high |
| 04 | Over temperature of PV module |
| 05 | Output short circuited. |
| 06 | Output voltage is too high. |
| 07 | Overload time out |
| 08 | Bus voltage is too high |
| 09 | Bus soft start failed |
| 10 | PV over current |
| 11 | PV over voltage |
| 12 | DCDC over current |
| 13 | Over current or surge |
| 14 | Bus voltage is too low |
| 15 | Inverter failed (Self-checking) |
| 18 | Op current offset is too high |
| 19 | Inverter current offset is too high |
| 20 | DC/DC current offset is too high |
| 21 | PV current offset is too high |
| 22 | Output voltage is too low |
| 23 | Inverter negative power |
| 24 | Op2 current offset is too high |
Warning Indicator
| Warning Code | Warning Event | Audible Alarm |
|---|---|---|
| 02 | Temperature is too High | Beep three times every second |
| 04 | Low battery | Beep once every second |
| 07 | Overload | Beep once every 0.5 second |
| 10 | Output power derating | Beep twice every 3 seconds |
| 14 | Fan blocked | None |
| 15 | PV energy is low | Beep twice every 3 seconds |
| 19 | Lithium Battery communication is failed | Beep once every 0.5 second |
| 21 | Lithium Battery over current | None |
| 22 | The load exceeds the set value of program 47 | None |
| E9 | Battery equalization | None |
| bP | Battery is not connected | None |
General Troubleshooting
| Problem | LCD/LED/Buzzer | Explanation / Possible cause | What to do |
|---|---|---|---|
| Unit shuts Down automatically during startup process. | LCD/LEDs and buzzer will be active for 3 seconds and then complete off. | The battery voltage is too low | 1. Re-charge battery. 2. Replace battery. |
| No response after power on. | No indication. | 1. The battery voltage is far too low. 2. Battery polarity is connected reversed. | 1. Check if batteries and the wiring are connected well. 2. Re-charge battery. 3. Replace battery. |
| Input voltage is displayed as 0 on the LCD and green LED is flashing. | Input protector is tripped | Check if AC breaker is tripped and AC wiring is connected well. | |
| Mains exist but the unit works in battery mode. | Green LED is flashing. | Insufficient quality of AC power. (Shore or Generator) | Check if AC wires are too thin and/or too long. Check if generator (if applied) is working well or if input voltage range setting is correct. (UPS / Appliance) |
| Green LED is flashing. | Set "Solar First" as the priority of output source. | Change output source priority to Utility first. | |
| When the unit is turned on, internal relay is switched on and off repeatedly. | LCD display and LEDs are flashing | Battery is disconnected. | Check if battery wires are connected well. |
| Fault code 07 | Overload error. The inverter is overload 110% and time is up. | Reduce the connected load by switching off some equipment. | |
| Fault code 05 | Output short circuited. | Check if wiring is connected well and remove abnormal load. | |
| Fault code 02 | Internal temperature of inverter component is over 100°C. | Check whether the air flow of the unit is blocked or whether the ambient temperature is too high. | |
| Buzzer beeps continuously and red LED is on. | Fault code 03 | Battery is over-charged. | Return to repair center. |
| The battery voltage is too high. | Check if spec and quantity of batteries are meet requirements. | ||
| Fault code 06/22 | Output abnormal (Inverter voltage below than 190Vac or is higher than 260Vac) | 1. Reduce the connected load. 2. Return to repair center | |
| Fault code 08/09/15 | Internal components failed. | Return to repair center. | |
| Fault code 13 | Over current or surge. | Restart the unit, if the error happens again, please return to repair center. | |
| Fault code 14 | Bus voltage is too low. | If the wires is connected well, please return to repair center. | |
| Another fault code | If the wires is connected well, please return to repair center. |
Specifications
Table 1 Line Mode Specifications
| INVERTER MODEL | 4.2KVA | 5.0KVA |
|---|---|---|
| Input Voltage Waveform | Sinusoidal (utility or generator) | |
| Nominal Input Voltage | 230Vac | |
| Low Loss Voltage | 170Vac±7V (UPS) 90Vac±7V (Appliances) | |
| Low Loss Return Voltage | 180Vac±7V (UPS); 100Vac±7V (Appliances) | |
| High Loss Voltage | 280Vac±7V | |
| High Loss Return Voltage | 270Vac±7V | |
| Max AC Input Voltage | 300Vac | |
| Nominal Input Frequency | 50Hz / 60Hz (Auto detection) | |
| Low Loss Frequency | 40±1Hz | |
| Low Loss Return Frequency | 42±1Hz | |
| High Loss Frequency | 65±1Hz | |
| High Loss Return Frequency | 63±1Hz | |
| Output Short Circuit Protection | Battery mode: Electronic Circuits | |
| Efficiency (Line Mode) | >95% (Rated R load, battery full charged) | |
| Transfer Time | 10ms typical (UPS); 20ms typical (Appliances) | |
| Output power derating: When AC input voltage drops to 95V or 170V depending on models, the output power will be derated. | Output Power Rated Power 50% Power 90V 170V 280V Input Voltage | |
Table 2 Inverter Mode Specifications
| INVERTER MODEL | 4.2KVA | 5.0KVA |
|---|---|---|
| Rated Output Power | 4.2KVA / 4.2KW | 5.0KVA / 5.0KW |
| Dual output function | Yes | Yes |
| Max. main output power | 4.2KVA / 4.2KW | 5.0KVA / 5.0KW |
| Output Voltage Waveform | Pure Sine Wave | |
| Output Voltage Regulation | 230Vac±5% | |
| Output Frequency | 50Hz or 60Hz | |
| Peak Efficiency | 94% | |
| Surge Capacity | 2* rated power for 5 seconds | |
| Nominal DC Input Voltage | 24Vdc | 48Vdc |
| Cold Start Voltage | 23.0Vdc | 46.0Vdc |
| Low DC Warning Voltage (Just for AGM and Flooded) | @ load < 20%: 22.0Vdc @ 20% ≤ load < 50%: 21.4Vdc @ load ≥ 50%: 20.2Vdc | @ load < 20%: 44.0Vdc @ 20% ≤ load < 50%: 42.8Vdc @ load ≥ 50%: 40.4Vdc |
| Low DC Warning Return Voltage (Just for AGM and Flooded) | @ load < 20%: 23.0Vdc @ 20% ≤ load < 50%: 22.4Vdc @ load ≥ 50%: 21.2Vdc | @ load < 20%: 46.0Vdc @ 20% ≤ load < 50%: 44.8Vdc @ load ≥ 50%: 42.4Vdc |
| Low DC Cut-off Voltage (Just for AGM and Flooded) | @ load < 20%: 21.0Vdc @ 20% ≤ load < 50%: 20.4Vdc @ load ≥ 50%: 19.2Vdc | @ load < 20%: 42.0Vdc @ 20% ≤ load < 50%: 40.8Vdc @ load ≥ 50%: 38.4Vdc |
Table 3 Charge Mode Specifications
| Utility Charging Mode | 4.2KVA | 5.0KVA |
|---|---|---|
| Max Charging Current (PV+AC) (@ VI/P=230Vac) | 100Amp | 100Amp |
| Max Charging Current (AC) (@ VI/P=230Vac) | 80Amp | 60Amp |
| Bulk Charging Voltage (Flooded Battery) | 29.2Vdc | 58.4Vdc |
| Bulk Charging Voltage (AGM / Gel Battery) | 28.2Vdc | 56.4Vdc |
| Floating Charging Voltage | 27Vdc | 54Vdc |
| Overcharge Protection | 32Vdc | 63Vdc |
| Battery reverse connection protection | No | No |
| Charging Algorithm | 3-Step | |
| Charging Curve | Graph showing Battery Voltage per cell and Charging Current over time, with Bulk, Absorption, and Maintenance phases. | |
Solar Input Specifications
| INVERTER MODEL | 4.2KVA | 5.0KVA |
|---|---|---|
| Rated Power | 5000W | 5000W |
| Max. PV Array Open Circuit Voltage | 500Vdc | |
| PV Array MPPT Voltage Range | 60Vdc~500Vdc | |
| Max. Input Current | 27A | 27A |
| Max. Charging Current (PV) | 100A | 100A |
Table 4 General Specifications
| INVERTER MODEL | 4.2KVA | 5.0KVA |
|---|---|---|
| Operating Temperature Range | -10°C to 55°C | |
| Storage temperature | -15°C~60°C | |
| Humidity | 5% to 95% Relative Humidity (Non-condensing) | |
| Dimension (D*W*H), mm | 368x312x105 | |
| Net Weight, kg | 6.7 | 9.3 |
Wi-Fi Plug Pro Quick Installation Guideline
1. Install the Wireless Antenna
Refer to the product overview diagram for the location of the WiFi antenna port. Screw in the provided WiFi antenna securely.
2. Download the SmartESS App
- Scan the QR code provided in the manual or product packaging to download the SmartESS App (available on iPhone App Store and Android).
- Open the App, click "Registration", and select "Mobile phone Registration" or "Email Registration".
- Turn on Bluetooth or WiFi on your mobile device as needed.
3. Bluetooth Connection to the Digital Collector
- Click the "Toolbox" in the app and select "BLE network" or "Wi-Fi network".
- If choosing Bluetooth distribution network, the app will automatically scan for nearby devices. On the "Bluetooth Pairing" page, find the PN corresponding to your digital collector and click "Connect".
4. Add Datalogger
- Log in to your account and click the "Datalogger" button. Tap the "+" button on the top-right corner of the datalogger page.
- Follow the prompts to type in the necessary information to add the datalogger. The PN number is located next to the machine appliance label. (Initial Password: 12345678)
5. Networking Settings
- Select the corresponding 2.4G WiFi network according to the prompts, fill in the password, and click "Start".
- The app will display "Connecting to the Network" and then confirm successful network configuration.
For detailed screenshots and step-by-step visual guidance, please refer to the full user manual (PDF) available at User Manual (PDF).
User Tips
- Optimal Performance: Ensure proper ventilation around the inverter to prevent overheating, which can impact efficiency and lifespan.
- Battery Compatibility: When using lithium batteries, always verify compatibility and ensure correct communication settings (RS485) are configured for optimal performance and protection.
- Wiring Safety: Double-check all wiring connections for tightness and correct polarity during installation to avoid electrical hazards and ensure stable operation.
- Monitoring: Utilize the Wi-Fi app for remote monitoring of your system's performance, battery status, and any alerts, allowing for proactive management.
- Load Management: Be mindful of the inverter's maximum output power and avoid overloading to prevent system shutdowns or damage.
Warranty and Support
For warranty information, technical support, or service inquiries, please contact your authorized dealer or the manufacturer directly. Keep your purchase receipt and product model number handy for faster service.
You can also refer to the complete user manual for more detailed information and diagrams: User Manual (PDF).