1. Introduction
This manual provides essential information for the safe and efficient operation of the INVT CHF100A series vector universal inverter. The CHF100A series is designed for adapting motors with 380V, 4KW heavy load, or 5.5KW light load, utilizing a DSP control system for advanced motor control.
It is primarily used in applications such as wind turbines and pump loads, where high speed control accuracy, torque response speed, and low frequency output are critical.
2. Safety Information
WARNING: Failure to follow these safety instructions may result in injury or electric shock.
- Always wait at least 10 minutes after disconnecting power until the DC bus capacitors fully discharge before performing any work on the inverter.
- Ensure all safety precautions are followed during installation, operation, and maintenance.
- Read the entire manual thoroughly before attempting installation or operation.
- Use proper grounding techniques for the inverter and associated equipment.

3. Installation
Proper installation is crucial for the inverter's performance and safety. This section outlines general guidelines. Refer to the full product manual for detailed wiring diagrams and specific installation steps.
3.1 Environmental Requirements
- Install in a clean, dry, and well-ventilated area.
- Avoid direct sunlight, corrosive gases, and excessive dust.
- Ensure ambient temperature is within the specified operating range.
3.2 Mounting
- Mount the inverter vertically on a sturdy, non-flammable surface.
- Allow sufficient clearance around the unit for proper heat dissipation.
3.3 Wiring
- All wiring must comply with local and national electrical codes.
- Ensure correct power phase number and supply voltage (380V for this model).
- Connect the motor according to the specified heavy load (4KW) or light load (5.5KW) configuration.
- Implement proper grounding for the inverter chassis and motor.
- Utilize the freely programmable input and output terminals as required for your application.
4. Operation
The CHF100A inverter offers flexible control options to suit various motor applications.
4.1 Control Modes
The inverter supports three primary control modes:
- No PG Vector Control (SVC): Provides high-performance speed sensorless vector control, effectively suppressing low-frequency shock and swing. Offers a starting torque of 0.5Hz/150%.
- V/F Control: Standard voltage/frequency control, suitable for general-purpose applications.
- Torque Control: For applications requiring precise torque management.
The desired control mode can be selected and configured via the inverter's parameters.
4.2 Frequency Setting
Multiple methods are available for setting the operating frequency:
- Digital setting via the control panel.
- Analog setting using external voltage or current signals.
- PID setting for process control applications.
- Communication setting via serial communication protocols.
4.3 Advanced Functions
- Simple PLC: The inverter includes 16 simple PLC functions for basic automation tasks.
- Multi-speed Control: Configure multiple preset speeds for various operational requirements.
- PID Control: Integrated PID controller for closed-loop process control.
- DC Braking: Supports both start and stop DC braking for controlled deceleration.
- Jump Frequency Control: Helps avoid mechanical resonance in the system, enhancing stability and reliability.
- Instantaneous Power Failure and Non-stop Function: Designed to maintain operation or recover smoothly during brief power interruptions.
5. Maintenance
Regular maintenance ensures the longevity and reliable operation of your INVT CHF100A inverter.
- Regular Inspection: Periodically check for dust accumulation, loose connections, and signs of overheating or damage.
- Cleaning: Keep the inverter's ventilation openings clear of obstructions. Use compressed air to remove dust from cooling fins and internal components.
- Capacitor Discharge: Always observe the 10-minute waiting period for DC bus capacitor discharge after power-off before performing any maintenance or inspection.
- Environmental Control: Ensure the operating environment remains within specified temperature and humidity limits.
6. Troubleshooting
This section provides general troubleshooting tips. For detailed error codes and solutions, please refer to the comprehensive user manual provided by the manufacturer.
- No Power: Check input power supply, fuses, and circuit breakers.
- Motor Not Running: Verify motor connections, control signal inputs, and ensure the inverter is enabled. Check for any fault codes displayed on the control panel.
- Overcurrent/Overload Fault: Inspect motor load, check for mechanical binding, and verify motor parameters are correctly set in the inverter.
- Overvoltage/Undervoltage Fault: Check input voltage stability. For overvoltage, consider adding a braking resistor if not already installed and if the application requires rapid deceleration.
7. Specifications
| Feature | Specification |
|---|---|
| Brand | INVT |
| Model | CHF100A-004G/CHF100A-5R5P-4 |
| Input Voltage | 380V (Typically 3-phase for industrial inverters) |
| Adapted Motor (Heavy Load) | 4KW |
| Adapted Motor (Light Load) | 5.5KW |
| Control Modes | V/F open loop, Vector control (SVC), Torque control |
| Starting Torque (SVC) | 0.5Hz/150% |
| Power Range | 1.5kW to 3MW (General series range; specific to this model is 4KW/5.5KW) |
| Built-in DC Reactor | Yes (for 18.5KW~90KW models; check specific model for confirmation) |
| Built-in Braking Unit | Yes (for 1.5~15KW models; check specific model for confirmation) |
| Programmable Logic Control | 16 simple PLC functions |
| Frequency Setting Modes | Digital, Analog, PID, Communication |
| Frame Material | Plastic |
| Origin | Mainland China |
8. User Tips
Based on general user feedback for similar industrial inverters:
- Parameter Backup: Before making significant changes to parameters, always back up your current settings. This can save considerable time during troubleshooting.
- Motor Tuning: For optimal performance, especially with vector control, perform the auto-tuning function for your specific motor if available.
- Cooling: Ensure adequate airflow around the inverter. Overheating is a common cause of faults and reduced lifespan.
- Grounding: Double-check all grounding connections. Proper grounding is critical for both safety and noise reduction.
9. Warranty and Support
For specific warranty terms, technical support, or service inquiries, please contact the seller or the official INVT customer service directly. Keep your purchase records handy when contacting support.