1. Introduction

The MESTEK EMF01R is a high-precision five-in-one electromagnetic wave radiometer designed for household and professional use. It integrates the detection of Radio Frequency (RF), Electric Field (E-field), Magnetic Field (H-field), Temperature, and Humidity into a single, portable device. Featuring a VA color display, three-axis detection, and various measurement modes, it provides comprehensive data for assessing electromagnetic environments.

MESTEK EMF01R device with display showing various readings
Front view of the MESTEK EMF01R showing its multi-functional display.

2. Package Contents

Upon unpacking, please ensure all the following items are present:

  • MESTEK EMF01R Electromagnetic Wave Radiometer
  • User Manual
  • Screwdriver
  • Carrying Pouch
Package contents including the meter, manual, screwdriver, and pouch
Included accessories with the EMF01R.

3. Device Overview

Familiarize yourself with the main components and controls of your EMF01R meter:

Diagram showing the features and buttons of the EMF01R
Key features and button functions of the EMF01R.
  • Inductive Probe (Sensor Head): Located at the top, this is the three-axis sensor for detecting electromagnetic fields.
  • LCD Display: VA reverse display color screen for clear readings.
  • RF Button: Short press to enter RF (Radio Frequency) measurement mode.
  • SEL Button: Short press to switch between E-field and H-field measurement modes. In H-field mode, press again to switch units (mG/uT).
  • Power Button (Center): Press and hold to power on/off the device.
  • AVG/MAX Button: Toggles between Average (AVG) and Maximum (MAX) value display.
  • HOLD Button: Freezes the current reading on the display. Press again to release.
  • Buzzer Switch: Controls the audible alarm.
  • Low Battery Indicator: Icon on the display indicates when batteries are low.
Back view of the EMF01R showing humidity and temperature sensors and battery compartment
Rear view of the EMF01R, highlighting the humidity and temperature sensors and battery compartment.

4. Setup

4.1 Battery Installation

  1. Locate the battery compartment on the back of the device.
  2. Use the provided screwdriver to open the battery cover.
  3. Insert 3 AAA 1.5V batteries, ensuring correct polarity (+/-).
  4. Close the battery cover and secure it with the screw.

4.2 Initial Power On

Press and hold the Power button (blue button in the center) for a few seconds until the display lights up. The device will perform a self-test and then enter the default measurement mode.

5. Operating Instructions

5.1 Power On/Off

  • Power On: Press and hold the Power button until the screen illuminates.
  • Power Off: Press and hold the Power button until the screen turns off. The device also features an automatic shutdown after approximately 15 minutes of inactivity.

5.2 Measurement Modes

The EMF01R supports three primary electromagnetic field measurement modes:

  • RF (Radio Frequency) Mode:

    Short press the RF button to enter RF measurement mode. The screen will display "RF". This mode detects high-frequency signals. The detectable range is 30MHz ~ 8GHz.

    EMF01R measuring RF radiation from a signal tower
    Measuring RF radiation from a signal tower.
  • E-field (Electric Field) Mode:

    Short press the SEL button. The screen will display "E-field". This mode measures the electric field values from electrical equipment. The detectable range is 40Hz ~ 100KHz.

    EMF01R measuring E-field radiation from a computer
    Measuring E-field radiation from a computer.
  • H-field (Magnetic Field) Mode:

    Short press the SEL button again (after E-field mode). The screen will display "H-field". This mode measures magnetic field radiation. Press SEL again to switch between mG (milligauss) and uT (microtesla) units. The detectable range is 40Hz ~ 100KHz.

    EMF01R measuring H-field radiation from a microwave
    Measuring H-field radiation from a microwave.

5.3 AVG/MAX and HOLD Functions

  • AVG/MAX: Press the AVG/MAX button to cycle between displaying the current real-time value, the average value (AVG), and the maximum value (MAX) detected during the measurement session.
  • HOLD: Press the HOLD button to pause and freeze the current reading on the display. This is useful for recording values. Press HOLD again to resume live measurement.

5.4 Temperature and Humidity Measurement

The EMF01R continuously measures ambient temperature and humidity, displayed on the screen. The temperature can be displayed in Celsius (°C) or Fahrenheit (°F).

5.5 Alarm Function and Interpretation

The device features an audible alarm and a visual analog bar display to indicate radiation levels. The color of the analog bar and the alarm frequency change based on the detected radiation intensity:

Analog-Digital Comparison Table (Alarm Thresholds)
Unit/Analog Display Green (Slow Alarm) Yellow (Tight Alarm) Red (Urgent Alarm)
uW/cm² (RF) 0.0 ~ 9.9 10 ~ 39.9 40 ~ 9999
V/m (E-field) 0 ~ 9 10 ~ 399 400 ~ 999
mG (H-field) 0.0 ~ 1.1 1.2 ~ 39.9 40.0 ~ 199.9
uT (H-field) 0.00 ~ 0.11 0.12 ~ 3.99 4.00 ~ 19.99

When the screen displays an electromagnetic radiation analog bar reaching the yellow or red area, the instrument will alarm, indicating that the radiation exceeds safe levels. Protective measures should be taken, and distance from the radiation source should be increased.

6. Maintenance

6.1 Cleaning

Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents, as they may damage the casing or display. Keep the sensor head clean and free from dust.

6.2 Battery Replacement

When the low battery indicator appears on the display, replace the 3 AAA batteries promptly to ensure accurate readings and continuous operation. Refer to section 4.1 for battery installation instructions.

6.3 Storage

When not in use for extended periods, remove the batteries to prevent leakage. Store the device in a cool, dry place, away from direct sunlight and extreme temperatures. The recommended storage temperature is -10°C to 60°C and humidity 0% to 80%RH.

7. Troubleshooting

  • Device does not power on:
    • Check if the batteries are installed correctly with the right polarity.
    • Replace with new AAA batteries if the existing ones are depleted.
    • Ensure the power button is pressed and held sufficiently.
  • Inaccurate readings:
    • Ensure the device is held steadily and not near strong magnetic or electric fields that are not being measured.
    • Verify that the correct measurement mode (RF, E-field, H-field) is selected for the type of radiation you intend to measure.
    • Check for any physical damage to the sensor head.
  • Display is blank or flickering:
    • Replace batteries.
    • If the issue persists, contact customer support.
  • No audible alarm:
    • Check if the buzzer switch is enabled.
    • Ensure radiation levels are above the alarm thresholds.

8. Specifications

Table of technical parameters for the EMF01R
Detailed technical parameters of the MESTEK EMF01R.
Parameter Value
Working height 2000m
Measurement method Electromagnetic induction, RF radio frequency receiving sensor
Display screen VA reverse display color screen
Maximum display 9999
Sampling rate About 0.4 seconds
Measurement range
RF uW/cm²: 0.0 ~ 9999
E-field V/m: 0 ~ 999
H-field uT: 0.00 ~ 19.99, mG: 0.0 ~ 199.9
Temperature 0 ~ 50°C
Humidity 0 ~ 99%RH
Test bandwidth
RF 30MHz ~ 8GHz
H-field 40Hz ~ 100KHz
E-field 40Hz ~ 100KHz
Accuracy
Temperature ±1.5°C
Humidity ±5%RH (no condensation environment)
Resolution V/m: 1, uT: 0.01, mG: 0.1, uW/cm²: 0.1, °C: 0.1, °F: 0.2, %RH: 1
Alarm method Sound, analog bar
Automatic shutdown About 15 minutes
Working current About 45mA
Working temperature and humidity 0 ~ 50°C / 0 ~ 99%RH
Storage temperature and humidity -10 ~ 60°C / 0 ~ 80%RH
Size 170 x 73 x 33mm
Weight About 165g (without battery)

9. User Tips

  • Home Appliance Checks: Use the E-field and H-field modes to check radiation levels from common household appliances like microwaves, computers, and televisions. Keep a safe distance if high readings are detected.
  • Outdoor Environment: The RF mode is useful for checking high-frequency radiation from sources like cell towers or Wi-Fi routers.
  • Consistent Readings: For more consistent readings, try to maintain a stable distance from the source and move the device slowly.
  • Three-Axis Detection: The three-axis sensor provides more accurate and comprehensive detection regardless of the device's orientation relative to the source.
  • Monitor Temperature and Humidity: Utilize the built-in temperature and humidity sensors to monitor environmental conditions alongside EMF levels.

10. Warranty and Support

For warranty information and technical support, please refer to the documentation provided at the point of purchase or contact the seller directly. Keep your purchase receipt as proof of purchase.

© 2023 MESTEK. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.