DATOUBOSS DT-5052

Contents

USER MANUAL

DATOUBOSS DT-5052 All-in-One Home Solar System

51.2V/102Ah LiFePO4 Battery with a Capacity of 5.22kWh, 6,000 Charge-Discharge Cycles

DATOUBOSS DT-5052 All-in-One Home Solar System

The DATOUBOSS DT-5052 All-in-One Home Solar System, featuring a 51.2V/102Ah LiFePO4 battery and 5kW hybrid inverter.

1. Introduction and Safety Instructions

Please retain this manual for future reference. This manual contains instructions for the installation as well as operation of the Home Storage Battery Pack. Please read all instructions and precautions in the manual carefully before installation and use. There are non-safe voltages inside the home energy storage battery pack; to avoid personal injury, users should not disassemble it by themselves, and contact our professional maintenance personnel if maintenance is needed.

1.1. Security Instructions

  1. Do not put the battery into water or get it wet!
  2. Do not charge the battery in a source of ignition or in extremely hot conditions! Do not use or store batteries near sources of heat such as fire or heaters! If the battery leaks or emits an odor, remove it immediately from close proximity to an open flame!
  3. Please use a dedicated charger!
  4. Do not reverse the positive and negative terminals!
  5. Do not connect the battery directly to a wall outlet or vehicle cigarette lighter outlet!
  6. Do not put the battery into a fire or heat the battery!
  7. It is prohibited to short-circuit the positive and negative terminals of the battery with wires or other metal objects, and it is prohibited to transport or store the battery together with necklaces, hairpins or other metal objects!
  8. Do not pierce the battery case with nails or other sharp objects, and do not hammer or foot the battery!
  9. Do not hit, throw or subject the battery to mechanical shocks!
  10. Direct soldering of battery terminals is prohibited!
  11. It is prohibited to disassemble the battery in any way!
  12. It is prohibited to place the battery in a microwave oven or pressure vessel!
  13. Prohibit the use of batteries in combination with primary batteries (e.g. dry cell batteries) or batteries of different capacities, models and varieties!
  14. Do not use the battery if it emits a strange odor, heat, deformation, discoloration or any other abnormal phenomenon; if the battery is in use or charging, it should be immediately removed from the appliance or charger and stop using it!

1.2. Attention

  1. Do not put the battery in an extremely hot environment, which will affect the performance of the battery, shorten the service life of the battery; and even cause safety accidents.
  2. If the electrolyte gets into your eyes after a battery leak, do not rub, flush with water, and seek medical assistance immediately. If left untreated, the eyes will be damaged.

1.3. Manufacturing Process Overview

Play video
Watch video online

Video: Overview of the DATOUBOSS manufacturing process, highlighting quality control and assembly.

2. Specifications

2.1. Overall Parameters

Parameter Value
Product ModelDT-5052
Battery TypeLiFePO4 Battery 102Ah
Battery Capacity5.22kWh
Dimensions (LxWxH)480×220×830mm (18.9 x 8.66 x 32.68 inches)
Weight57.3kg
Nominal Voltage51.2V
Battery Cycle Life≥ 6000 cycles/70%DOD@25°C
Nominal Capacity102Ah
Charge Current50A (Max. 100A)
Discharge Current100A (Max. 120A)
Full Charge Voltage58.4Vdc
Discharge Cut-Off Voltage43.2Vdc
Operating Temperature-10°C ~ 50°C
Storage Temperature0°C ~ 45°C
Screen TypeLCD
Parallel Functionnot have
On-grid Functionnot have
Self-Consumption Power Off≤ 300uA
Dimensions of DT-5052

Image: Product dimensions (48cm x 22cm x 83cm) and weight (57.3kg).

2.2. Inverter Specifications

Parameter Value
INVERTER INPUT
Voltage Range170~280Vdc (computer equipment)
Frequency Range40~70Hz, Default
PV Input Voltage Range120~450Vdc
PV Maximum Charging Current100A
INVERTER OUTPUT
Output SystemL+N+PE
Output Voltage208/220/230/240Vac
Output Precision≤ ±5%
Power Factor1
Output FrequencyUtility Mode: Follows utility frequency
Battery Mode: 50/60Hz±0.1%
Output Harmonic Distortion≤ 3% Linear Load
≤ 5% Non-linear load PF=0.7
Switching TimeComputer equipment: line mode to battery mode 10 ms (normal)
Household electrical equipment: line mode to battery mode 10 ms (general)
Overload Capability1min@102%~ 110% Load
10s@110%~ 130% Load
3s@130%~ 150% Load
0.2s@>150% Load
Output Power5kW
BATTERY CHARGING
Charging ModeAC Charging / PV Charging
Charging Current50A (Max100A)

3. Product Overview and Features

3.1. System Diagram

Schematic Diagram of Home Solar Energy Storage System

Image: Schematic diagram illustrating the connection of Photovoltaic Modules, Generator, Power Grid, and Home Loads to the DT-5052 unit.

3.2. Key Features

  • Brand New Battery Cells: Ensures longer life and reliable performance.
  • 5kW High-Power Hybrid Inverter: Provides worry-free household load management.
  • Photovoltaic Energy Storage + Inverter: Designed to save electricity and reduce costs.
  • Lower Electricity Bills: Optimized for energy efficiency.
  • High Quality 360° Wheels: Excellent wheels for smooth movement with 400+kgs load.
  • BMS Interface Compatibility: Compatible with major brands like Pylontech, Growatt, and Deye.
  • Comprehensive BMS Function Protection: Includes Short-circuit, Over-current, High & Low Temp, Cell Balancing, Overcharge, and Over-discharged Protection.
Product features including LCD display, 360 rotating wheels, grade-A battery cells, BMS monitoring, and circuit breaker BMS interface compatible with Pylontech, Growatt, Deye BMS Function Protection: Short-circuit, Over-current, High & Low Temp, Cell Balancing, Overcharge, Over-discharged Protection

Images: Visual representation of key features including LCD display, mobility, battery cell quality, BMS monitoring, circuit breaker, brand compatibility, and various BMS protection functions.

3.3. Component Identification

Labeled diagram of DT-5052 components and ports

Image: Detailed diagram of the DT-5052 unit, labeling all indicators, buttons, and ports.

  1. AC Indicator
  2. Invert Indicator
  3. Charging Indicator
  4. Fault Indicator
  5. LCD Display
  6. Down Button
  7. Enter Button
  8. Up Button
  9. ESC Button
  10. Switching Indicator
  11. Operation Indicator
  12. Alarm Indicator
  13. Air Circuit-Breaker
  14. AC Output
  15. AC Input
  16. PV Input
  17. Bms Communication Port
  18. Dry Contact
  19. USB Communication Port
  20. Wifi/GPRS Communication Port
  21. Power switch button
  22. Cooling fan
  23. Anti-Surge Protection Switch

3.4. Communication Ports

  • Dry Junction Function: Controls diesel generator switch for battery charging. Normally closed at NC-N and NO-N. When battery voltage reaches low disconnect point, relay energizes, closing NO-N and disconnecting NC-N. NO-N can drive resistive loads 125VAC/1A, 230VAC/1A, 30VDC/1A.
  • RS485 Communication Function: Pins are defined as: pin 1 is RS485-B, pin 2 is RS485-A, pin 4 is CAN-H, pin 5 is CAN-L.
  • USB Communication Function: For communication with host computer software (requires