Midea R-WSL250-DXX-P, 17110600000810, 17110600000790, 17110600000991, WSL250-DXX-A, 17110600001211

Contents

Midea Air Conditioning Motherboard Instruction Manual

Models: R-WSL250-DXX-P, 17110600000810, 17110600000790, 17110600000991, WSL250-DXX-A, 17110600001211

Brand: Midea

1. Introduction

This manual provides detailed instructions for the installation, operation, maintenance, and troubleshooting of your Midea Air Conditioning Motherboard. This product is designed to serve as a replacement or core control unit for various Midea air conditioning systems, ensuring optimal performance and reliability. Please read this manual thoroughly before proceeding with any installation or operation.

2. Safety Information

WARNING: Electrical Shock Hazard

  • Always disconnect power to the air conditioning unit before installing, servicing, or removing the motherboard.
  • Only qualified and experienced personnel should perform installation and maintenance.
  • Ensure all wiring connections are secure and correctly matched to prevent electrical shorts or damage.
  • Do not operate the unit with damaged wiring or components.
  • Keep the motherboard dry and away from moisture.

3. Installation and Wiring

Careful installation is crucial for the proper functioning of the air conditioning unit. Refer to the specific model images below for visual guidance on terminal layouts and component placement.

3.1 Pre-installation Checks

  • Verify that the new motherboard model matches the original unit's specifications.
  • Inspect the motherboard for any visible damage before installation.
  • Ensure all necessary tools (screwdrivers, wire strippers, multimeter) are available.

3.2 Mounting the Motherboard

Mount the motherboard securely within the air conditioning unit's control box using the designated mounting points. Ensure it is stable and free from vibrations.

3.3 Wiring Connections

Refer to the following images for detailed wiring diagrams and component identification for specific motherboard models. Always match the wiring from the air conditioning unit to the corresponding terminals on the new motherboard.

Midea Air Conditioning Motherboard Model 17110600000790

Figure 1: Midea Air Conditioning Motherboard Model 17110600000790
This image displays the Midea air conditioning motherboard, model 17110600000790. It features various electronic components, relays, capacitors, and terminal blocks for electrical connections. Key connection points include power input, compressor, fan, and sensor interfaces. Several DIP switches are visible for configuration. Labels such as '0123', 'TBH', 'TBH2', 'BM1', 'C1', 'P', 'Q', 'E1', 'H1', 'H2' indicate specific connection points.

Midea Air Conditioning Motherboard Type A, Model 17110600000991

Figure 2: Midea Air Conditioning Motherboard Type A, Model 17110600000991
This image shows the 'Type A' variant of the Midea air conditioning motherboard, model 17110600000991. It includes a digital display (likely for error codes or status), multiple relays, and clearly labeled terminal blocks for various connections. DIP switches are present for system configuration. The label 'A款' indicates its type.

Midea Air Conditioning Motherboard Type B, Model 17110600001211

Figure 3: Midea Air Conditioning Motherboard Type B, Model 17110600001211
This image presents the 'Type B' Midea air conditioning motherboard, model 17110600001211. Similar to other variants, it features a central processing unit, power regulation components, relays, and a series of terminal blocks for connecting to the air conditioning unit's various parts. DIP switches are included for customization. The label 'B款' indicates its type.

Common Terminal Labels (Refer to specific board for exact layout):

  • Power Input: Typically labeled 'L' (Live), 'N' (Neutral), 'GND' (Ground).
  • Compressor: Connects to the compressor unit.
  • Fan Motor: Connections for indoor and outdoor fan motors (e.g., 'FAN_IN', 'FAN_OUT').
  • Sensors: Ports for temperature sensors (e.g., 'TEMP_ROOM', 'TEMP_COIL').
  • Communication: Terminals for communication with other parts of the AC system or remote control.
  • DIP Switches: Used for configuring operational parameters such as unit capacity, fan speeds, or specific modes. Consult your AC unit's service manual for correct DIP switch settings.

4. Operating Instructions

Once the motherboard is correctly installed and all connections are secure, restore power to the air conditioning unit. The unit should power on and be ready for operation via its standard controls (e.g., remote control, wall thermostat).

  • Initial Power-Up: After restoring power, observe the unit for any unusual sounds or smells. The digital display (if present, as on Model 17110600000991) may show an initial boot sequence or status code.
  • Functionality Test: Test all modes of operation (Cool, Heat, Fan, Dry) and ensure the compressor, indoor fan, and outdoor fan activate correctly.
  • Temperature Control: Verify that the unit responds accurately to temperature adjustments.

5. Maintenance

The Midea Air Conditioning Motherboard is designed for long-term reliability with minimal maintenance. However, periodic checks can help ensure its longevity.

  • Visual Inspection: Annually, with power disconnected, visually inspect the motherboard for dust accumulation, loose connections, or signs of overheating (discoloration, burnt components).
  • Cleaning: Use a soft brush or compressed air to gently remove dust from the board. Do not use liquids or abrasive cleaners.
  • Connection Integrity: Ensure all terminal connections remain tight and free from corrosion.

6. Troubleshooting

If your air conditioning unit experiences issues after motherboard installation, consider the following common troubleshooting steps:

ProblemPossible CauseSolution
Unit does not power onNo power supply; loose power connection; faulty fuseCheck circuit breaker; verify power wiring; inspect and replace fuse if necessary.
Fan not operatingLoose fan motor connection; faulty fan motor; incorrect DIP switch settingCheck fan motor wiring; test fan motor; verify DIP switch configuration.
Compressor not startingLoose compressor connection; low refrigerant; faulty compressor; sensor issueCheck compressor wiring; consult HVAC technician for refrigerant/compressor issues; check sensor connections.
Error code displayed (if applicable)System fault; sensor malfunction; communication errorRefer to your specific AC unit's service manual for error code definitions and solutions.

If problems persist after following these steps, it is recommended to consult a professional HVAC technician.

7. Specifications

AttributeDetail
BrandMidea
TypeAir Conditioning Fitting, Air Conditioner Parts
ApplicationHome
CertificationCE
OriginMainland China
ElectricNo (refers to not being an electric appliance itself, but a component)
High-concerned chemicalnone
Model NumbersR-WSL250-DXX-P, 17110600000810, 17110600000790, 17110600000991, WSL250-DXX-A, 17110600001211
Package Weight1.0 kg
Package Dimensions30cm x 25cm x 10cm

8. User Tips

  • Double-Check Compatibility: Before purchasing, always confirm the exact model number and visual layout of your old motherboard against the product images to ensure perfect compatibility.
  • Photograph Old Wiring: Take clear photos of your existing wiring connections before disconnecting anything. This will serve as an invaluable reference during installation.
  • Static Discharge: Wear an anti-static wrist strap or frequently touch a grounded metal object to prevent electrostatic discharge (ESD) damage to the sensitive electronic components.
  • Test Before Closing: After installation, perform a full functional test of the AC unit before reassembling all covers and panels.

9. Warranty and Support

For warranty information, technical support, or service inquiries, please contact the original seller or authorized Midea service center. Keep your purchase receipt as proof of purchase.