1. Introduction
Thank you for choosing the MFUZOP 48V 314Ah Lithium LiFePO4 Battery Portable Power Supply. This advanced energy storage system is designed for efficient energy utilization in various applications, including RVs and home solar setups. It features a 200A BMS, APP remote control, and a user-friendly color touch screen for real-time monitoring. This manual provides essential information for the safe and effective installation, operation, and maintenance of your battery system.

2. Safety Information
⚠️ Please mind potential fire risk and strictly follow the instruction manual for charging and storage. For disposal, please check your local authority's website for more information and dispose of the lithium-ion battery safely in accordance with the applicable legal requirements.
- Always ensure proper ventilation around the battery during operation and charging.
- Do not expose the battery to extreme temperatures, direct sunlight, or moisture.
- Use only compatible charging equipment and follow recommended charging parameters.
- Avoid short-circuiting the battery terminals.
- Keep out of reach of children and pets.
- In case of fire, use a Class D fire extinguisher (for lithium fires). Do not use water.
3. Package Contents
Before installation, inspect the equipment to ensure that there is no damage inside the package. You should receive the following items:

- Solar cell module x 1
- Mounting bracket x 1
- Short screws x 3
- Short screws x 2
- Expansion screw x 8
- Positive and negative electrode connecting wire x 1
- Communication cable x 1
- User Manual x 1
4. Product Overview
The MFUZOP 48V 314Ah LiFePO4 Battery is an all-in-one energy storage solution designed for ease of use and portability. It features a robust design with casters for easy movement and a color touch screen for intuitive control and monitoring.
4.1. Component Identification

- Switch Indicator Lights
- Reset switch
- DIP Address
- Dry contact
- RS485 Communication Port
- CAN Communication Port
- RS232 Communication Port
- RS485-1 & RS485-2 Communication Ports
- Operation Indicator
- Alarm Indicator
- Battery Indicator
- Battery Positive Terminal (+)
- Battery Negative Terminal (-)
- Mains Switch
- Air Switch
5. Setup and Installation
5.1. Unboxing and Initial Inspection
Carefully remove the battery unit and all accessories from the packaging. Inspect for any visible damage during transit. If any damage is found, contact your supplier immediately.
5.2. Physical Placement
The MFUZOP battery is equipped with mobile pulleys (casters) for easy movement. Place the unit on a stable, level surface in a well-ventilated area, away from direct sunlight, heat sources, and moisture. Ensure adequate clearance for air circulation.
5.3. Electrical Connections
Connect the positive and negative electrode connecting wires to the corresponding battery terminals (12 and 13). Ensure connections are secure and correctly polarized.
5.4. Parallel Wiring Instructions
The MFUZOP battery supports parallel connection of up to 15 units for increased energy capacity (up to 241.05 kWh). When connecting multiple battery packs in parallel, use the DIP switches on the Battery Management System (BMS) to set unique addresses for each unit.

5.4.1. DIP Switch Configuration
The DIP switch (component 3) is used to assign a unique address to each battery pack in a parallel setup. The maximum number of parallel units is 15. Units 5 and 6 of the DIP switch are reserved and do not perform any function.

Refer to the table below for DIP switch settings:
| Address Bit (Binary) | Decimal | 4 | 3 | 2 | 1 | Explanation |
|---|---|---|---|---|---|---|
| 0001 | 1 | OFF | OFF | OFF | ON | Set PACK1 to be used by a host or single machine |
| 0010 | 2 | OFF | OFF | ON | OFF | Set PACK2 |
| 0011 | 3 | OFF | OFF | ON | ON | Set PACK3 |
| ... | ... | ... | ... | ... | ... | And so on ..... |
| 1110 | 14 | ON | ON | ON | OFF | Automatically assigned as PACK14 in wiring order |
| 1111 | 15 | ON | ON | ON | ON | Automatically assigned as PACK15 in wiring order |
5.5. Communication Connections
The battery supports RS485, CAN, and RS232 communication protocols, compatible with various inverters. Use the provided communication cable to connect the battery to your inverter or host computer as per your system requirements. Refer to the interface description in the parallel wiring diagram for pin details.
6. Operating Instructions
6.1. Powering On/Off
- To power on the unit, first ensure all connections are secure.
- Turn on the Mains Switch (14).
- Turn on the Air Switch (15).
- The Switch Indicator Lights (1) and Operation Indicator (9) should illuminate.
- To power off, reverse the steps: turn off the Air Switch, then the Mains Switch.
6.2. Color Touch Screen Operation
The MFUZOP battery features a color touch screen for easy operation and real-time monitoring. You can switch between multiple pages to view various parameters.

The screen displays critical information such as:
- Voltage (V): Current battery voltage.
- Capacity (Ah): Remaining battery capacity.
- Current (A): Current charge/discharge rate.
- Power (W): Instantaneous power output/input.
- State: Charging (CHG) and Discharging (DSG) status.
- Temperature (℃): Minimum and maximum cell temperatures.
Navigate through the menu options (Master, Slave, Parameter, Protocol, Setting) to adjust settings or view detailed information.
6.3. APP Remote Control
The battery system supports APP remote control for convenient monitoring and management from your smartphone or tablet. Refer to the separate APP user guide for detailed instructions on setup and usage.
7. Maintenance
7.1. General Care
- Keep the battery unit clean and free from dust and debris. Use a dry, soft cloth for cleaning.
- Ensure all connections are tight and free from corrosion.
- Regularly check the operating environment to ensure it remains within the recommended temperature range.
7.2. Charging and Discharging
The battery is equipped with multi-layer protection to ensure safe operation. Adhere to the following guidelines:

- Charging Temperature: 0℃ to 45℃. The system includes 0℃ low-temperature charging protection and 55℃ high-temperature charging protection.
- Discharging Temperature: -20℃ to 65℃. The system includes -20℃ low-temperature discharge protection and 55℃ high-temperature discharge protection.
- Overcurrent Protection: 215A for both charging and discharging.
- Voltage Protection: Overcharge protection recovery at 54.0V, overpressure protection at 58.4V. Over-discharge protection at 43.2V, with recovery at 46.4V.
Always operate the battery within these specified ranges to ensure longevity and safety.
8. Troubleshooting
This section provides guidance on common issues you might encounter. For more complex problems, please contact customer support.
8.1. Indicator Lights
- Operation Indicator (9): Indicates normal operation. If off or blinking abnormally, check power connections and system status on the touch screen.
- Alarm Indicator (10): Illuminates when a fault or warning condition is detected. Refer to the touch screen for specific error codes or messages.
- Battery Indicator (11): Shows the general status of the battery.
8.2. Common Issues and Solutions
| Problem | Possible Cause | Solution |
|---|---|---|
| Battery not powering on | Mains Switch or Air Switch off; loose connections | Ensure both switches are ON. Check all power cable connections. |
| Alarm Indicator is on | Overcurrent, over/under voltage, temperature extreme | Check the touch screen for specific error messages. Reduce load if overcurrent. Verify charging/discharging parameters and ambient temperature. |
| No display on touch screen | Unit not powered on; screen malfunction | Ensure unit is powered on. If still no display, contact support. |
| Parallel units not communicating | Incorrect DIP switch settings; faulty communication cable | Verify DIP switch addresses for each unit. Check communication cables for damage and proper connection. |
9. Specifications

| Attribute | Value |
|---|---|
| Brand Name | DATOUBOSS |
| Model Number | MF-48314S-B |
| Type | LiFePO4 |
| Cathode Materials | LiFePO4 |
| Battery Type | Solid state |
| Total Energy | 16.07 kWh |
| Single Battery Capacity | 314 Ah |
| Nominal Operating Voltage | 51.2 V |
| Charge Voltage | 57.6 ± 0.8 V |
| Internal Resistance | <13.9 mΩ |
| Standard Input Current | 210 A |
| Standard Output Current | 157 A (210A Max) |
| Overcurrent Protection (Charging) | 215 A |
| Overcurrent Protection (Discharging) | 215 A |
| Overpressure Protection | 58.4 V |
| Short Circuit Protection | Yes, method via load removal and charge disconnection |
| Power Delivery Rate | 40% to 60% |
| Equalization | Passive balancing |
| Cycle Life | >8000 cycles (70% SOH 25℃), >3000 cycles (70% SOH 45℃) |
| Protection Level | P20 |
| Communication Protocols | RS232, RS485, CAN |
| Operating Temperature (℃) | -20~+65℃ |
| Dimensions (L×W×H) | 453×260×879 mm |
| Weight | 113 kg |
| Certification | CE, RoHS, pse |
10. User Tips
- For optimal performance and longevity, try to keep the battery operating within its recommended temperature range.
- When connecting multiple units in parallel, double-check the DIP switch settings for each battery to ensure correct addressing and communication.
- Utilize the APP remote control feature for convenient monitoring of battery status and performance, especially in remote installations.
- Regularly check the touch screen for any warning or error messages to address potential issues promptly.
11. Warranty and Support
For warranty information, technical support, or service inquiries, please contact DATOUBOSS Energy Storage System Store directly. Keep your purchase records handy when contacting support.