1. Introduction
1.1. Purpose and Scope
This manual describes the assembly, installation, operation, and troubleshooting of the DAXTROMN Hybrid Solar Inverter/Charger unit. Please read this manual carefully before installation and operation. Keep this manual for future reference. It provides safety and installation guidelines, as well as information on tools and wiring.
1.2. Key Features
- Pure sine wave inverter
- Inverter running without battery
- Built-in MPPT solar controller
- Configurable input voltage range for home appliances and personal computers via LCD setting
- Configurable battery charging current based on applications via LCD setting
- Configurable AC/Solar Charger priority via LCD setting
- Compatible with mains voltage or generator power
- Auto restart while AC is recovering
- Overload/Over temperature/short circuit protection
- Smart battery charger design for optimized battery performance
- Cold start function
1.3. Basic System Architecture
The inverter/charger is designed to power various appliances in home or office environments, including motor-type appliances like tube lights, fans, refrigerators, and air conditioners. A complete running system typically includes a generator or utility power source and optional PV modules.

Figure 1: Hybrid Power System Overview
This diagram illustrates the connection of solar panels, the solar inverter, a battery bank, and home appliances. It also shows an optional pure inverter for AC output.
2. Safety Instructions
WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.
- Before using the unit, read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual.
- CAUTION: To reduce the risk of injury, charge only deep-cycle lead-acid type rechargeable batteries. Other types of batteries may burst, causing personal injury and damage.
- Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
- To reduce the risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
- CAUTION: Only qualified personnel can install this device with a battery.
- NEVER charge a frozen battery.
- For optimum operation, follow required specifications to select appropriate cable size.
- Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short-circuit batteries or other electrical parts, which could cause an explosion.
- Strictly follow the installation procedure when disconnecting AC or DC terminals.
- A fuse is provided as over-current protection for the battery supply.
- GROUNDING INSTRUCTIONS: This inverter/charger should be connected to a permanent grounded wiring system. Comply with local requirements and regulations.
- NEVER cause AC output and DC input to be short-circuited. Do NOT connect to the mains when DC input short-circuits.
- Warning!! Only qualified service persons are able to service this device. If errors persist after following the troubleshooting table, send this inverter/charger back to a local dealer or service center for maintenance.
3. Setup
3.1. Unpacking and Inspection
Before installation, inspect the unit for any damage. The package should contain:
- The unit x 1
- User manual x 1
- PV connector x 4
- Battery fuse x 1
3.2. Preparation
Before connecting all wirings, remove the bottom cover by unscrewing the four screws.
3.3. Mounting the Unit
Consider the following points when selecting an installation location:
- Do not mount the inverter on flammable construction materials.
- Mount on a solid surface.
- Install at eye level for easy LCD display reading.
- Ambient temperature should be between 0°C and 55°C for optimal operation.
- Adhere to vertical wall mounting.
- Ensure sufficient heat dissipation and space for wiring by maintaining clearances (e.g., 20cm on sides, 50cm top/bottom).
SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.
Install the unit by screwing three M4 or M5 screws into the wall.
3.4. Battery Connection
CAUTION:
- Install a separate DC over-current protector or disconnect device between the battery and inverter.
- All wiring must be performed by qualified personnel.
- Use appropriate cable for battery connection to ensure system safety and efficient operation.
Recommended Battery Cable and Terminal Size:
| Model | Max Amperage | Battery Capacity | Wire Size | Cable mm² | Terminal Size (mm) L/W/D | Torque Value |
|---|---|---|---|---|---|---|
| 8.5KW | 180A | 400AH | 4AWG*2 | 25 | 37/22/8.4 | 10~12 Nm |
| 11.0KW | 220A | 600AH | 2AWG*2 | 38 | 37/22/8.4 | 10~12 Nm |
Battery Connection Steps:
- Make positive and negative cables based on recommended terminal size.
- Connect all battery packs as units require, using recommended battery capacity.
- Insert battery cable flatly into the inverter's battery connector, ensuring bolts are tightened with a torque of 10-12Nm. Verify correct polarity at both the battery and inverter/charger.
3.5. AC Input/Output Connection
CAUTION:
- Install a separate AC breaker (recommended 63A) between the inverter and AC input power source.
- Do NOT mis-connect input and output connectors (marked “IN” and “OUT”).
- All wiring must be performed by qualified personnel.
- Use appropriate cable for AC input connection.
Suggested Cable Requirement for AC Wires:
| Model | Gauge | Torque Value |
|---|---|---|
| All Models | 6 AWG | 1.2~1.4Nm |
AC Connection Steps:
- Before making AC input/output connections, open the DC protector or disconnector.
- Remove 10mm insulation sleeve for six conductors. Shorten phase L and neutral conductor N by 3mm.
- Insert AC input wires according to polarities (Ground: yellow-green, L: brown/black, N: blue) and tighten terminal screws. Connect PE protective conductor first.
- Insert AC output wires according to polarities and tighten terminal screws. Connect PE protective conductor first.
- Ensure all wires are securely connected.
CAUTION: Ensure correct AC wire polarity. Reversed L and N wires can cause utility short-circuits in parallel operation.
CAUTION: Appliances like air conditioners require 2-3 minutes to restart. If power fluctuates rapidly, it can damage appliances. Check if your appliance has a time-delay function.
3.6. PV Connection
CAUTION:
- Install a separate DC circuit breaker between the inverter and PV modules.
- All wiring must be performed by qualified personnel.
- Use appropriate cable for PV module connection.
PV Connection Table:
| Model | Typical Amperage | Cable Size | Torque |
|---|---|---|---|
| All Models | 18A*2 | 10 AWG | 1.4~1.6 Nm |
PV Module Selection:
- Open Circuit Voltage (Voc) of PV modules must not exceed the max. PV array open circuit voltage of the inverter.
- Open Circuit Voltage (Voc) of PV modules should be higher than the min. battery voltage.
Solar Charging Mode Specifications:
| INVERTER MODEL | 8.5KW | 11.0KW |
|---|---|---|
| Max. PV Array Open Circuit Voltage | 500VDC | |
| PV Array MPPT Voltage Range | 60VDC~500VDC | |
| Max. PV INPUT CURRENT | 18A*2 | |
PV Module Wire Connection Steps:
- Remove 10mm insulation sleeve for positive and negative conductors.
- Check correct polarity of connection cable from PV modules and PV input connectors. Connect positive to positive and negative to negative.
- Ensure wires are securely connected.
3.7. Final Assembly
After connecting all wirings, replace the bottom cover by screwing the two screws back.
4. Product Overview
The following diagrams illustrate the physical components and connections of the inverter.

Figure 2: Product Overview and Components
This image details the LCD display, status indicators, function buttons, and various input/output ports on the inverter.
Component Descriptions:
- LCD Display
- Status Indicator
- Charging Indicator
- Fault Indicator
- Function Buttons (ESC, UP, DOWN, ENTER)
- Power ON/OFF Switch
- Battery Negative/Positive Outlet Hole
- RS232 Communication Port (RJ45)
- RS485 Communication Port (RJ45)
- RS232 Communication Port (DB9)
- Dry Contact Port
- PV1 Input
- PV2 Input
- AC Input
- AC Output
- Grounding Point
Note: RS232 communication ports (DB9 and RJ45) cannot be used simultaneously; only one can be used at a time.
5. Operating
5.1. Power ON/OFF
Once the unit is properly installed and batteries are connected, simply press the On/Off switch (located on the side of the case) to turn on the unit.
5.2. Operation and Display Panel
The front panel includes three indicators, four function keys, and an LCD display to show operating status and power information.
LED Indicators:
| Indicator | Color | Status | Message |
|---|---|---|---|
| AC/INV | Green | Solid On | Output powered by utility (Line mode) |
| Flashing | Output powered by battery or PV (Battery mode) | ||
| CHG | Green | Solid On | Battery fully charged |
| Flashing | Battery is charging | ||
| FAULT | Red | Solid On | Fault occurs in the inverter |
| Flashing | Warning condition occurs in the inverter |
Function Keys:
| Key | Description |
|---|---|
| ESC | To exit setting mode |
| UP | To go to previous selection |
| DOWN | To go to next selection |
| ENTER | To confirm selection or enter setting mode |
5.3. LCD Display and Settings
Press and hold the ENTER button for 3 seconds to enter setting groups mode. Use UP/DOWN to select groups (F0-F4) and ENTER to confirm or ESC to exit.
- F0: General parameters (e.g., AC input voltage range, power saving mode, auto restart, buzzer mode).
- F1: AC output parameters (e.g., output source priority, output voltage, output frequency).
- F2: Battery parameters (e.g., battery type, charger source priority, bulk/floating charging voltage, max charging current, equalization settings).
- F3: Time parameters (year, month, day, hour, minute, second).
- F4: System parameters (reset stored data).
The LCD display information switches by pressing UP or DOWN. It shows input/output voltage, frequency, active/apparent power, battery voltage/load percentage, charging power, PV power, and more.
5.4. Dry Contact Signal
A dry contact (3A/250VAC) is available on the rear panel. It can be configured in two models:
- Model1: Delivers a signal to an external device when battery voltage reaches a warning level.
- Model2: Triggers a grounding box to connect neutral and grounding of AC output when the unit is working in battery mode.
6. Maintenance
6.1. Battery Equalization
The equalization function reverses negative chemical effects like stratification and removes sulfate crystals, extending battery life. It is recommended to equalize batteries periodically.
How to Apply: Enable battery equalization in LCD setting program F2-17. Then, set the equalization interval (F2-21) or activate immediately (F2-22).
When to Equalize: In float stage, when the equalization interval is reached or activated immediately, the controller enters the Equalize stage.
Charging Time and Timeout: During equalization, the controller charges the battery until it reaches the equalization voltage. It then maintains this voltage until the set equalized time is reached. If the battery doesn't reach the equalization voltage within the timeout, the controller stops equalization and returns to float stage.
6.2. Setting for Lithium Battery
If using a configured lithium battery, connect the RS485 port of the battery's BMS to the inverter's BMS (RS485) communication port. This cable transmits critical battery information.
Lithium Battery Communication and Setting:
- Re-configure charging voltage, current, and discharge cut-off voltage according to lithium battery parameters.
- The inverter will start or stop charging based on the lithium battery status.
Setting for PYLON US2000 Lithium Battery: Follow specific DIP switch settings for baud rate and battery group address. Connect the RS485 cable, switch on the lithium battery, press its start button, then turn on the inverter. Select battery type “Li2” in LCD program F2-01. The battery icon on the LCD will light up if communication is successful.
Setting for Lithium Battery Without Communication:
- Set battery type as “LIB” in program F2-01.
- Obtain battery BMS specifications (Max charging voltage/current, discharging protection voltage).
- Set C.V voltage (F2-03) and floating charging voltage (F2-04) based on BMS specs.
- Set Low DC cut-off voltage (F2-08) and Max charging current (F2-09) based on BMS specs.
- Set voltage point back to utility source (F2-05) when using “SBU priority”.
7. Troubleshooting
This section provides guidance for common issues, fault codes, and warning indicators.
7.1. Troubleshooting Table
| Problem | LCD/LED/Buzzer | Explanation / Possible Cause | What to do |
|---|---|---|---|
| Unit shuts down automatically during startup | LCD/LEDs active for 3s then off | Battery voltage too low | Re-charge/replace battery |
| No response after power on | No indication | Battery voltage too low / reversed polarity | Check connections, re-charge/replace battery |
| Mains exist but unit works in battery mode | Green LED flashing | Insufficient AC power quality / SBU/SUB priority set | Check AC wires/generator, change output source priority to Utility |
| Internal relay switches on/off repeatedly | LCD/LEDs flashing | Battery disconnected | Check battery wires |
| Buzzer beeps continuously, red LED on | Fault code DO, A2, F2, B0, A1/A5, F3/F4, A2, F5, A3 | Overload, short circuit, over temp, battery over-charged/too high, output abnormal, internal components failed, bus voltage too low, output unbalanced | Reduce load, check wiring, ensure airflow, return to repair center, check battery specs, restart unit |
7.2. Fault Reference Codes
Fault codes consist of a group code (first) and a number (last), e.g., C0.
- A: Inverter group fault code (A0: Output short circuited, A1: Output voltage too high, etc.)
- B: Battery group fault code (B0: Battery voltage too high, B1: DCDC over current, etc.)
- C: PV group fault code (C0: PV over current, C1: PV over voltage, etc.)
- D: Output group fault code (D0: Overload time out, D1: Op current offset too high)
- F: Other group fault code (F0: Over temperature of inverter module, F1: Over temperature of PV module, etc.)
7.3. Warning Indicators
Warning codes also consist of a group code and number, e.g., 0C.
- 0B: Battery low (Beep once every second)
- 1B: Battery is not connected (None)
- 2B: Battery equalization (None)
- 3B: Battery low and not up to setting (Beep twice every 3 seconds)
- 4B: Lithium battery communication abnormal (Beep once every 0.5 second)
- 1C: PV energy too weak (Beep twice every 3 seconds)
- 0D: Overload (Beep once every 0.5 second)
- 0F: Temperature too high (Beep three times every second)
8. Specifications
Detailed specifications for various operating modes and general characteristics are provided below.
8.1. Table 1 Line Mode Specifications
| Parameter | 8.5KW | 11.0KW |
|---|---|---|
| Input Voltage Waveform | Sinusoidal (utility or generator) | |
| Nominal Input Voltage | 230Vac | |
| Low Loss Voltage (UPS/Appliances) | 170Vac±7V / 90Vac±7V | |
| High Loss Voltage | 280Vac±7V | |
| Max AC Input Voltage | 300Vac | |
| Nominal Input Frequency | 50Hz / 60Hz (Auto detection) | |
| Output Short Circuit Protection | Battery mode: Electronic Circuits | |
| Efficiency (Line Mode) | >95% (Rated R load, battery full charged) | |
| Transfer Time (UPS/Appliances) | 10ms typical / 20ms typical | |
8.2. Table 2 Inverter Mode Specifications
| Parameter | 8.5KW | 11.0KW |
|---|---|---|
| Rated Output Power | 8.5KVA/8.5KW | 11.0KVA/11.0KW |
| Output Voltage Waveform | Pure Sine Wave | |
| Output Voltage Regulation | 230Vac±5% | |
| Output Frequency | 60Hz or 50Hz | |
| Peak Efficiency | 94% | |
| Overload Protection | 5.5s@≥140% load; 10.5s@100%~140% load | |
| Surge Capacity | 2* rated power for 5 seconds | |
| Nominal DC Input Voltage | 48Vdc | |
| Cold Start Voltage | 46.0Vdc | |
8.3. Table 3 Charge Mode Specifications
| Parameter | 8.5KW | 11.0KW |
|---|---|---|
| Charging Current (Max) (AC+PV) | 140Amp | 160Amp |
| AC Charging Current (Max) | 120Amp (@ VI/P=230Vac) | |
| Bulk Charging Voltage (Flooded/AGM/Gel) | 58.4Vdc / 56.4Vdc | |
| Floating Charging Voltage | 54Vdc | |
| Overcharge Protection | 63Vdc | |
| Charging Algorithm | 3-Step | |
| Solar Input Rated Power | 5000W*2 | 5500W*2 |
| Max. PV Array Open Circuit Voltage | 500Vdc | |
| PV Array MPPT Voltage Range | 60Vdc~500Vdc | |
| Max. MPPT Charge Current | 140A | 160A |
| Max. Input Current | 18A*2 | |
8.4. Table 4 General Specifications
| Parameter | 8.5KW | 11.0KW |
|---|---|---|
| Safety Certification | CE | |
| Operating Temperature Range | -10°C to 55°C | |
| Storage Temperature | -15°C to 60°C | |
| Humidity | 5% to 95% Relative Humidity (Non-condensing) | |
| Dimension (D*W*H), mm | 540x403x122 | |
| Net Weight, kg | 14.4 | 14.8 |
9. User Tips
- Output Voltage: This inverter series is designed for 230VAC output. It is not compatible with 120VAC systems.
- Phase Compatibility: This inverter operates as a single-phase unit. It is not suitable for three-phase power systems.