HOMCOM 823-074V90, 823-074V91

Contents

HOMCOM Portable Air Conditioner User Manual

Models: 823-074V90, 823-074V91

1. Safety Information

IMPORTANT: Please read all instructions carefully before use and retain for future reference.

The refrigerant used in this mobile air conditioner is R290, an environmentally friendly hydrocarbon. R290 is odorless, ozone-free, and has a very low environmental impact. Always handle with care and follow safety guidelines.

1.1 General Warnings

  • The appliance must be installed, operated, and stored in a room with a floor area larger than 7m².
  • Keep ventilation openings clear of obstruction.
  • Servicing must be performed only as recommended by the manufacturer.
  • The appliance must be stored in a well-ventilated area where the room size corresponds to the room area specified for operation.
  • The appliance must be stored in a room without continuously operating open flames (e.g., an operating gas appliance) and ignition sources (e.g., an operating electric heater).
  • Installation must comply with national wiring regulations.
  • Compliance with national gas regulations must be observed.
  • This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory, or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning safe use and understanding of hazards.
  • Children must not play with the appliance.
  • Cleaning and user maintenance must not be performed by children without supervision.
  • Ensure the back of the unit is at least 50 cm or more from a wall.
  • If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or similarly qualified persons to avoid a hazard.
  • Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
  • Do not pierce or burn.
  • Be aware that refrigerants may not contain an odor.
  • Any person involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry-accredited assessment authority.
  • Servicing requiring assistance from other skilled personnel must be carried out under the supervision of a person competent in the use of flammable refrigerants.
  • All working procedures affecting safety must only be carried out by competent persons.

1.2 Important Notes

  • The air conditioning unit is suitable for indoor use only.
  • Follow local grid interconnection rules and ensure proper grounding. Consult a professional electrician if needed.
  • Place the machine on a flat and dry surface, maintaining a distance of at least 50cm from surrounding objects or walls.
  • After installation, ensure the power plug is intact and firmly plugged into the outlet, and the power cord is arranged to prevent tripping.
  • Do not insert any objects into the air inlet and outlet. Keep them free from obstructions.
  • When drainage pipes are installed, ensure they are properly connected, not distorted or bent.
  • Adjust the upper and lower wind-guide strips of the air outlet gently to avoid damage.
  • When moving the machine, ensure it is in an upright position.
  • Keep the machine away from gasoline, flammable gas, stoves, and other heat sources.
  • Do not disassemble, overhaul, or modify the machine arbitrarily. Contact the manufacturer or professionals for repair in case of malfunction.
  • Do not install or use the air conditioning in bathrooms or other humid environments.
  • Do not pull the plug to turn off the machine.
  • Do not place cups or other objects on the body to prevent water or other liquids from spilling into the air conditioning.
  • Do not use insecticide sprays or other flammable substances near the air conditioning.
  • To clean the air conditioning, disconnect the power supply and wipe with a half-wet soft cloth. Use mild detergent for stubborn dirt.
  • Do not operate your air conditioner in a wet room such as a bathroom or laundry room.

2. Features and Components

2.1 Key Features

  • Modern and compact design with smooth lines.
  • 4-in-1 functionality: Cooling, Dehumidification, Air Supply (Fan), and Sleep Mode.
  • High-mounted outdoor interface for easy assembly and smooth heat pipe flow.
  • LED display control panel and high-quality, user-friendly remote control.
  • Integrated air filtration capability.
  • Programmable 24-hour timer function.
  • Automatic compressor restart protection (3-minute delay) and other safety protection functions.
  • Maximum operation temperature for cooling: 35/24°C. Operation temperature range: 7-35°C.

2.2 Components Overview

The unit consists of the main air conditioner body and several accessories for installation and operation. Refer to the diagram below for a visual guide to the components.

Portable Air Conditioner with all accessories
Figure 2.2.1: Portable Air Conditioner unit and its accessories, including the exhaust pipe, window sealing plate, remote control, and drainage hose.
  • Top Cover
  • Control Panel
  • Air Outlet Louvers
  • Left Side Panel
  • Base
  • Casters (wheels)
  • Front Housing
  • Right Side Panel
  • Rear Housing
  • Winding Column (for power cord storage)
  • Air Vent
  • EVA Filter
  • CON Filter
  • Drainage Hole

For detailed diagrams of the exhaust pipe assembly and window sealing plate assembly, please refer to Figures 1, 2, and 3 in the official PDF user manual.

3. Setup and Installation

WARNING: Before using the mobile air conditioning unit, keep it upright for at least two hours to allow the refrigerant to settle.

The air conditioning unit can be easily moved within a room. When moving, ensure it remains in an upright position and is placed on a flat surface. Do not install or use the unit in bathrooms or other humid environments.

3.1 Installing the Heat Pipe Assembly

  1. Take out the outer connector assembly and the exhaust pipe assembly from the packaging.
  2. Insert the heat pipe assembly (the end with the exhaust joint) into the back panel vent slot. Push it to the left until it is securely in place. (Refer to Figure 1 in the official PDF manual for a visual guide).

3.2 Installing the Window Sealing Plate Components

  1. Open the window halfway and mount the window sealing plate assembly to the window frame. Components can be placed horizontally or vertically. (Refer to Figures 2 and 3 in the official PDF manual for visual examples).
  2. Pull the various components of the window sealing plate assembly open and adjust their opening distance so that both ends contact the window frame. Fix the components in place.

Notes for Window Sealing Plate:

  • The flat end of the exhaust pipe joints must be snapped into place.
  • The pipe must not be distorted or have substantial turning (greater than 45°). Ensure the ventilation of the exhaust pipe is not blocked.

3.3 Positioning the Unit

  1. Move the machine with the installed heat pipe and fittings in front of the window. Ensure a minimum distance of 50 cm between the unit body and walls or other objects. (Refer to Figure 4 in the official PDF manual for a visual guide).
  2. Elongate the exhaust pipe and snap its flat end into the hole of the window sealing plate assembly. (Refer to Figures 5 and 6 in the official PDF manual for visual examples).

Important Notice for Exhaust Hose:

The length of the exhaust hose should be between 280mm and 1500mm, based on the air conditioner's specifications. Do not use extension tubes or replace it with different hoses, as this may cause malfunction or overheating due to blocked exhaust.

Portable Air Conditioner in a room with exhaust hose
Figure 3.3.1: Proper placement of the portable air conditioner with the exhaust hose connected to a window kit.

4. Operation

4.1 Control Panel Operation

The control panel features several buttons and a display for easy operation.

KeyFunction
Power KeyPress to turn the machine on or off.
Mode KeyPress to switch between Cooling, Fan, and Dehumidifying modes.
Sleep KeyIn Cooling Mode, press to activate Sleep Mode for energy-saving and quiet operation.
Up/Down KeysPress to change the setting temperature (not available in Fan or Dehumidifying mode) or setting time.
Speed KeyIn Cooling and Fan modes, press to select High or Low wind speed. (Note: May not run as set due to anti-cold conditions). Invalid in Dehumidifying mode (fan operates at low speed).
Timer KeyPress to set the timer. When the timing symbol flashes, use Up/Down keys to select the desired timing value (1-24 hours, adjustable by one hour).
DisplayShows current settings and status.

When the machine is first powered on, it will sound and enter standby status.

4.2 Remote Control Operation

The remote control provides convenient access to all functions.

KeyFunction
PowerTurn the machine on or off.
TimerSet timing.
DownReduce temperature and timing set value.
ModeSwitch between Cooling, Fan, Dehumidifying modes.
UpIncrease temperature and timing set value.
FanSelect High or Low wind speed.
Sleep ModeTurn on Sleep Mode.

4.3 Protection Functions

  • Frost Protection: In cooling, dehumidifying, or economic power-saving mode, if the exhaust pipe temperature is too low, the machine automatically enters protection status. It will revert to normal operation when the temperature rises.
  • Overflow Protection: If water in the water pan exceeds the warning level, the machine will alarm and the "FULL" indicator light will flash. You must drain the water (refer to Section 5.1 Drainage Instructions). The machine will return to its original state after drainage.
  • Compressor Protection: To extend the compressor's service life, there is a 3-minute delay booting protection function after the compressor is turned off.

5. Drainage Instructions

This machine offers two drainage methods: manual drainage and continuous drainage.

5.1 Manual Drainage

  1. When the machine stops due to a full water tank, turn off the power and unplug the power plug.
  2. Carefully move the machine to avoid spilling water from the water pan at the bottom.
  3. Place a water container below the side water outlet located at the rear of the unit.
  4. Unscrew the drainage cover and unplug the water plug. The water will automatically flow into the container.

Notes for Manual Drainage:

  • Keep the drainage cover and water plug properly.
  • During drainage, the body can be tilted slightly backward.
  • If the water container cannot hold all the water, plug the water outlet as soon as possible before it overflows to prevent water from flowing onto the floor or carpet.
  • After the water is discharged, re-insert the water plug and tighten the drainage cover.

5.2 Continuous Drainage (Optional - Dehumidifying Mode Only)

  1. Unscrew the drainage cover and unplug the water plug.
  2. Set the drainage pipe into the water outlet.
  3. Connect the drainage pipe to a bucket or suitable drainage area.

6. Maintenance

Before cleaning and maintenance, always turn off the machine and unplug it.

6.1 Cleaning the Surface

Clean the surface of the machine with a wet soft cloth. Do not use chemical solvents such as benzene, alcohol, or gasoline, as these can damage the air conditioner's surface or even the entire machine.

6.2 Cleaning the Filter Screen

If the filter screen is clogged with dust, the effectiveness of the air conditioning will be reduced. Be sure to clean the filter screen once every two weeks.

Filter frame and filter components diagram
Figure 6.2.1: Diagram showing the filter frame and filter components (for illustrative purposes, actual appearance may vary).

6.3 Cleaning the Upper Filter Screen Frame

  1. Unscrew the screw fixing the EVA filter net and back shell with a screwdriver, then remove the EVA filter net.
  2. Wash the EVA filter screen in warm water with neutral detergent (approximately 40°C / 104°F). Rinse it clean and dry it in the shade.

7. Unit Storage

  1. Unscrew the drainage cover, unplug the water plug, and discharge the water from the water pan into other containers or directly tilt the body to drain the water.
  2. Turn on the machine and adjust it to low-wind ventilation mode. Maintain this state until the drainage pipe becomes dry, ensuring the inside of the body is dry to prevent mildew.
  3. Turn off the machine, unplug the power plug, and wrap the power cord around the winding column. Install the water plug and the drainage cover.
  4. Remove the exhaust pipe and store it properly.
  5. Cover the air conditioning unit with a plastic bag. Store it in a dry place, out of reach of children, and take dust control measures.
  6. Remove batteries from the remote control and store them properly.

Note: Ensure the unit body is placed in a dry place and all machine components are stored properly.

8. Troubleshooting

Do not attempt to repair or disassemble the air conditioning unit yourself. Unqualified repairs can cause damage to users or property. If problems persist after following these steps, contact professional service.

ProblemReasonSolution
Air conditioning does not work.No electricity.Turn on after connecting to a socket with electricity.
The overflow indicator displays "FL".Discharge the water inside.
Ambient temperature is too low or too high.Recommended operation temperature: 7-35 °C (44-95 °F).
Cooling effect is not good.In cooling mode, room temperature is lower than set temperature.Change the set temperature.
In dehumidification mode, ambient temperature is low.The machine is placed in a room with an ambient temperature greater than 17 °C (62 °F).
Direct sunlight.Pull the curtain.
Doors or windows are open; many people present; other heat sources in cooling mode.Close doors and windows, and add new air conditioning.
Filter screen is dirty.Clean or replace the filter screen.
Air inlet or outlet is blocked.Clear obstructions.
Big Noise.Air conditioning is not placed on a flat surface.Put the air conditioning on a flat and hard place (to reduce noise).
Compressor does not work.Overheat protection starts.Wait for 3 minutes until the temperature is lowered, then restart the machine.
Remote control does not work.Distance between machine and remote control is too far.Let the remote control get close to the air conditioning.
Remote control not aligned with receiver.Ensure remote control directly faces the receiver.
Batteries are dead.Replace batteries.
Displays 'E1'.Pipe temperature sensor is abnormal.Check the pipe temperature sensor and related circuitry.
Displays 'E2'.Room temperature sensor is abnormal.Check the room temperature sensor and related circuitry.

9. Specifications

The specific technical parameters of the machine are subject to the nameplate on the product.

AttributeValue
Model823-074V90, 823-074V91
BrandHOMCOM
Dimensions (L x W x H)29.7L x 28.8P x 69.7A cm
Recommended Area20-30 m²
Max Cooling Capacity7000 BTU/H (2kW)
Dehumidification Capacity36 L/day
Air Circulation300 m³/H
Temperature Range16-31 °C (Operation range: 7-35°C)
Rated Power780W
VoltageAC 220-240V 50/60Hz
RefrigerantR290 (150 grams max dosage)
Noise Level (Night Mode)55dB
Suitable Window Length65-120cm
Power Cable Length1.8 m
Exhaust Tube Length1.5 m
Drainage Tube Length1 m
Fuse ParametersType: 5H, 5N, 5ET or 932; Voltage: 250V; Current: 3.15 A

9.1 Refrigeration Cycle Schematic Diagram

The air conditioner operates on a refrigeration cycle involving a Compressor, Condenser, Capillary, and Evaporator. For a detailed schematic diagram, please refer to Section X. Addendum in the official PDF user manual.

Portable Air Conditioner dimensions and components
Figure 9.1.1: Dimensions of the Portable Air Conditioner and its accessories.

10. User Tips

  • For optimal cooling, ensure all windows and doors are closed in the room where the unit is operating.
  • Regularly check and clean the air filter (every two weeks) to maintain efficiency and air quality.
  • When using the dehumidification mode, consider setting up continuous drainage for convenience.
  • Utilize the 24-hour timer to pre-cool your room before you arrive home or to turn off the unit automatically after you fall asleep.
  • The Sleep Mode is designed for quieter operation and energy saving, making it ideal for nighttime use.

11. Warranty and Support

For any questions or support regarding your HOMCOM Portable Air Conditioner, please contact our customer care center.

11.1 Customer Service Contact (UK)

  • Phone: 0044-800-240-4004
  • Email: enquiries@mhstar.co.uk

For other regions, please refer to the contact information provided in the multi-language section of the official PDF user manual (Page 99).

An official user manual in PDF format is available for download and detailed reference: Download User Manual (PDF)

Disposal: Do not dispose of the abandoned machine with other unsorted waste. Such waste should be placed separately for special use, following local regulations.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.