1. Introduction
The NJTY S-M8 infrared thermal imager is a portable, basic thermal radiation test and measurement equipment designed for power inspection, maintenance, industrial applications, firefighting, scientific research, and other scenarios. It features high-definition infrared thermal imaging, dual-light fusion, and data storage capabilities, allowing users to quickly capture surface temperature changes, identify hot/cold spots, and pinpoint target areas.
To ensure optimal performance and safety, it is recommended to fully charge the battery before first use and to read this manual carefully to understand the operation process and safety precautions.
2. Key Features
- Infrared Thermal Imaging: Captures real-time infrared signals, displaying hot spots (high temperature areas) and cold spots (low temperature areas on the screen, providing a visual representation of temperature distribution.
- Dual-Light Fusion: Supports the fusion of visible light and infrared thermal images, with adjustable transparency, for detailed observation and temperature monitoring.
- Data Storage: Equipped with an 8GB TF memory card, supporting BMP image format for storing numerous snapshots and temperature data (including central, highest, and minimum temperatures).
- Wide Temperature Range: Measures from -20°C to 800°C (-4°F to 1472°F) with a basic accuracy of ±2°C (or ±3% of the measured value), and a display resolution of 0.1°C/32.18°F.
- High/Low Temperature Alarm: Customizable alarm values for high and low temperatures.
- Adjustable Emissivity: Emissivity can be adjusted from 0.01 to 1.00 for accurate readings across various materials.
- 2.8-inch LCD Screen: Provides a clear display with adjustable backlight brightness (0%~100%).
3. Package Contents
The following items are included in your package:
- 1x NJTY SM8 Thermal Imager
- 1x Lanyard
- 1x 8GB TF Card
- 1x Type-C Cable
- 1x Portable Bag
- 1x User Manual



4. Product Overview and Parts Identification
Familiarize yourself with the components of your thermal imager:

| No. | Part Name | Function |
|---|---|---|
| 1 | Infrared Sensor | Senses ambient temperature and assists in calibrating thermal imaging data. |
| 2 | Visible Light Camera | Collects visible light images to generate thermal images. |
| 3 | Make-up Light (LED) | Supplements light in low-light environments to improve clarity of visible light pictures. |
| 4 | Trigger Button | Short press: take photos. Long press for 3 seconds: turn on/off supplementary light. |
| 5 | Lanyard | For portable storage, anti-lost, anti-slip, and decorative purposes. |
| 6 | Screen (2.8-inch LCD) | Displays thermal imaging screen, operation menu, and temperature data. |
| 7 | Key Area | Includes power on/off key, up/down keys, OK key, and menu key. |
| 8 | Charging Port (Type-C) | Connects Type-C charging cable for device charging and picture data transmission. |
| 9 | SD Card Slot | Insert TF memory card to store snapshots and data. |
5. Setup and Basic Operation
5.1 Initial Setup
- Screen Film: Gently peel off the tearable screen film from the display.
- Insert TF Card: Insert the provided 8GB TF card into the SD card slot.
- Charge Device: Connect the Type-C cable to the charging port and a power source to charge the device. The battery icon on the screen will indicate charging status.
5.2 Power On/Off
- Power On: Long press the [On/Off key] for 3 seconds. The device will automatically enter the main measurement interface.
- Power Off: Long press the [On/Off key] for 3 seconds on any interface. The screen will prompt "confirm shutdown". Press the [OK key] to confirm, or press the [On/Off key] to cancel.
5.3 Basic Interface Operation
- Switch Thermal Imaging Color Palette: Press the [OK key] to cycle through available color palettes.
- Adjust Dual-Light Fusion Transparency: Press the [Up key] to increase transparency (visible light becomes clearer) or the [Down key] to reduce transparency (thermal imaging becomes more prominent).
- Take Photos and Save: Short press the [Trigger button]. The screen will display "Save Successfully" (approx. 2 seconds), and photos will be stored in the SD card's root directory.
- Turn On/Off Supplementary Light: Press and hold the [Trigger button] for 3 seconds. The supplementary light will turn on/off. It automatically turns off after power-off and defaults to off on the next power-on.
6. Settings Menu
To access the settings menu, press the [MENU key] from the main interface. Use the [Up key]/[Down key] to navigate, [OK key] to enter submenus, and the [On/Off key] to return to the previous menu.
6.1 Image Settings
- Color Palette: Select the color scheme for thermal imaging. Options include "32 colors, Rainbow, Iron Red, Rock Red, White Hot, Black Hot". Navigate to 'Color Palette' in the menu, select your preference, and press [OK key] to save.

Figure 6.1: Available color palettes for thermal imaging. - Fusion Transparency: Adjust the transparency of dual-light fusion (0%~100%). Navigate to 'Merge Opa' in the menu, use [Up key] to increase transparency (+20%/time) or [Down key] to reduce transparency (-20%/time), and press [OK key] to save.

Figure 6.2: Adjusting fusion transparency.
6.2 Storage Management
- Browse Snapshots: View saved BMP format snapshots. Enter 'Browse Snapshots' to see the last saved photo. Use [Up key]/[Down key] to switch photos. Press [OK key] to open the snapshot menu, where you can select 'View Snapshot Information' or 'Delete Current Snapshot'. Press [On/Off button] to exit browsing.
- Snapshot Information: Displays file name, file size, shooting time, resolution, emissivity, central temperature, maximum temperature, and minimum temperature.
- Delete Snapshots: In the snapshot browsing interface, select 'Delete Snapshot' and confirm with [OK key].
- Format SD Card: Clears all contents of the SD card. Navigate to 'Format SD Card' in the menu, confirm with 'Yes' using [OK key]. Warning: Back up important data before formatting as it cannot be recovered.
6.3 System Settings
- Language Setting: Supports 6 languages. Navigate to 'Language Set' in the menu, select your language, and press [OK key] to save.
- Date and Time Setting: Set the year, month, day, hour, and minute. Navigate to 'Datetime Set', adjust values using [Up key]/[Down key] and [Left key] to switch fields, then press [OK key] to save.
- Automatic Shutdown: Set the device to automatically shut down after a period of inactivity (Off, 1, 3, 5, 10, 30, 60 minutes). Navigate to 'Timeoff Set', select duration, and press [OK key] to save.

Figure 6.3: Automatic shutdown settings. - Restore Factory Settings: Resets all menu settings to default values. Navigate to 'Factory Reset', confirm with 'Yes' using [OK key]. Note: This only restores menu settings and does not affect thermal imaging probe calibration data or SD card snapshots.
6.4 Temperature-Related Settings
- Emissivity Setting: Adjust the device's reception efficiency for infrared signals. Options include preset values (e.g., water 0.96, stainless steel 0.14, aluminum plate 0.09) or custom adjustment (0.10~0.99). Navigate to 'Emissivity Set', select mode or adjust value, and press [OK key] to save.

Figure 6.4: Emissivity settings and common material values. - Temperature Unit Setting: Select between Celsius (°C) and Fahrenheit (°F). Navigate to 'TEMP Unit Set', select unit, and press [OK key] to save. The main interface temperature data will update synchronously.
- Temperature Alarm: Set high and low temperature alarm values. Navigate to 'TEMP Alarm', select HTW (High Temperature Warning) or TAL (Low Temperature Warning), adjust the value using [Up key]/[Down key], and press [OK key] to save.

Figure 6.5: Temperature alarm settings.
6.5 Display Settings
- Home Page Settings: Customize displayed items on the main interface (e.g., highest temperature, lowest temperature, emissivity, color palette status, LED supplementary light status). Navigate to 'Main Page Set', select items, and press [OK key] to toggle on/off.
- Screen Backlight Settings: Adjust screen brightness from 0% to 100%. Navigate to 'Screen Backlight', use [Up key]/[Down key] to adjust brightness, and press [OK key] to save.

Figure 6.6: Screen backlight adjustment feature.
6.6 USB Mode
When the SD card is recognized, connect the device to a computer via the Type-C cable. The device will function as a mobile storage device, allowing you to view, copy, and delete snapshot files on the SD card.
Important Note:
- Temperature measurement, photo taking, and other operations are not possible in USB mode.
- After disconnecting from the computer, the device will return to normal operation.
- Always "eject the USB flash drive" from your computer before unplugging the cable to prevent data damage.

7. Specifications
| Parameter | Specification | Notes |
|---|---|---|
| Model | S-M8 | Unique model identification |
| Display Screen | 2.8-inch LCD, 320*240 resolution | Supports backlight brightness adjustment (0%~100%) |
| Camera Pixels | 300,000 pixels | Visible light imaging resolution 480*640 |
| Infrared Thermal Imaging Resolution | 1024 pixels (32*32) | Thermal sensitivity 150mK (detects minimum temperature difference) |
| Field of View Angle | 33° horizontal | Observable angle range in horizontal direction |
| Temperature Measurement Range | -20°C to 800°C (-4°F to 1472°F) | Basic accuracy ±3°C, display resolution 0.1°C/°F |
| Emissivity | 0.10~0.99 (custom adjustment) + preset material values | Preset values include water, stainless steel, aluminum plate, etc. |
| Wavelength Range | 8~14µm | Infrared detection suitable for most non-transparent objects |
| Image Mode | Thermal imaging, visible light, dual-light fusion | Dual light fusion supports transparency adjustment (0%~100%) |
| Color Palette | 32 colors, rainbow, iron red, rock red, white hot, black hot | Quickly switch on the main interface with the OK key |
| Storage Space | 8GB TF card (supports expansion, compatible devices required) | Save format is BMP, single photo approx. 2MB |
| Interface Type | Type-C USB | For charging and data transmission (USB mode) |
| Automatic Shutdown Time | Off, 1, 3, 5, 10, 30, 60 minutes | Automatically shuts down when idle to save power (default is 10 minutes) |
| Working Temperature | -10°C to 45°C (14°F to 113°F) | Measurement may be impossible beyond this range |
| Battery Capacity | 2000mAh | Continuous use for approx. 4 hours when fully charged (50% backlight) |
| Product Size | 200 * 80mm | Excluding prominent parts (buttons, interfaces) |
| Weight | 260g (excluding packaging and batteries) | Portable design, suitable for handheld use |
8. Troubleshooting
- Issue: Photos are not saving, or "Save Successfully" prompt does not appear.
Solution: Check if the SD card is correctly inserted (the SD card icon should not be red) and ensure the SD card is not full. - Issue: Device functions are limited or unresponsive when connected to a computer.
Solution: In USB mode, temperature measurement, photo taking, and other operations are disabled. Disconnect the device from the computer to restore normal functionality. Always safely eject the USB drive from your computer before unplugging the cable to prevent data corruption.
9. User Tips
- Customizing Display: You can customize the items displayed on the main interface. If certain data (e.g., lowest temperature) is not shown, enable it in the 'Main Page Settings' menu.
- Battery Life Management: For frequent use, set the automatic shutdown to '30 minutes' or '60 minutes' to avoid repeated power-on operations. For long periods of inactivity, setting it to '1 minute' can help save power.
- Optimal Screen Brightness: For outdoor use, adjust the screen backlight to 80%~100%. For indoor use, 40%~60% is recommended to balance clarity and power consumption.
10. Maintenance
To ensure the longevity and optimal performance of your NJTY SM8 Thermal Imager, follow these maintenance guidelines:
- Cleaning: Use a soft, dry cloth to clean the device. Do not use abrasive cleaners or solvents.
- Storage: Store the device in its portable bag in a cool, dry place when not in use. Avoid extreme temperatures and humidity.
- Battery Care: Recharge the battery regularly, even if the device is not used frequently, to maintain battery health.
- Software Updates: Check the manufacturer's website periodically for any firmware updates to ensure your device has the latest features and bug fixes.
11. Warranty and Support
Specific warranty information for this product is not provided in this manual. Please refer to the seller's terms and conditions or contact the point of purchase for warranty details and support.
For further assistance or technical inquiries, please contact NJTY Official Store customer service.